首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AimTo evaluate the performance of volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.BackgroundRapidArc is a novel technique that has recently been made available for clinical use. Planning study was done for volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.Materials and methodsTen patients with advanced tumors of the nasopharynx, oropharynx, and hypopharynx were selected for the planning comparison study. PTV was delineated for two different dose levels and planning was done by means of simultaneously integrated boost technique. A total dose of 70 Gy was delivered to the boost volume (PTV boost) and 57.7 Gy to the elective PTV (PTV elective) in 35 equal treatment fractions. PTV boost consisted of the gross tumor volume and lymph nodes containing visible macroscopic tumor or biopsy-proven positive lymph nodes, whereas the PTV elective consisted of elective nodal regions. Planning was done for IMRT using 9 fields and RapidArc with single arc, double arc. Beam was equally placed for IMRT plans. Single arc RapidArc plan utilizes full 360° gantry rotation and double arc consists of 2 co-planar arcs of 360° in clockwise and counter clockwise direction. Collimator was rotated from 35 to 45° to cover the entire tumor, which reduced the tongue and groove effect during gantry rotation. All plans were generated with 6 MV X-rays for CLINAC 2100 Linear Accelerator. Calculations were done in the Eclipse treatment planning system (version 8.6) using the AAA algorithm.ResultsDouble arc plans show superior dose homogeneity in PTV compared to a single arc and IMRT 9 field technique. Target coverage was almost similar in all the techniques. The sparing of spinal cord in terms of the maximum dose was better in the double arc technique by 4.5% when compared to the IMRT 9 field and single arc techniques. For healthy tissue, no significant changes were observed between the plans in terms of the mean dose and integral dose. But RapidArc plans showed a reduction in the volume of the healthy tissue irradiated at V15 Gy (5.81% for single arc and 4.69% for double arc) and V20 Gy (7.55% for single arc and 5.89% for double arc) dose levels when compared to the 9-Field IMRT technique. For brain stem, maximum dose was similar in all the techniques. The average MU (±SD) needed to deliver the dose of 200 cGy per fraction was 474 ± 80 MU and 447 ± 45 MU for double arc and single arc as against 948 ± 162 MU for the 9-Field IMRT plan. A considerable reduction in maximum dose to the mandible by 6.05% was observed with double arc plan. Double arc shows a reduction in the parotid mean dose when compared with single arc and IMRT plans.ConclusionRapidArc using double arc provided a significant sparing of OARs and healthy tissue without compromising target coverage compared to IMRT. The main disadvantage with IMRT observed was higher monitor units and longer treatment time.  相似文献   

2.
3.
ObjectiveTo determine the optimum energy and beam arrangement for prostate intensity-modulated radiation therapy (IMRT) delivery using an Elekta Beam Modulator? linear accelerator, in order to inform decisions when commissioning IMRT for prostate cancer.MethodsCMS XiO was used to create IMRT plans for a prostate patient. Arrangements with 3, 5, 7, 9 and 11 equally spaced fields, containing both a direct anterior and a direct posterior beam were used, with both 6 MV and 10 MV photons. The effects of varying the maximum number of iterations, leaf increment, number of intensity levels and minimum segment size were investigated. Treatment plans were compared using isodose distributions, conformity indices for targets and critical structures, target dose homogeneity, body dose and plan complexity.ResultsTarget dose conformity and homogeneity and sparing of critical structures improved with an increasing number of beams, although any improvements were small for plans containing more than five fields. Set-ups containing a direct posterior field provided superior conformality around the rectum to anterior beam arrangements. Mean non-target dose and total number of monitor units were higher with 6 MV for all beam arrangements. The dose distribution resulting from seven 6 MV beams was considered clinically equivalent to that with five 10 MV beams.ConclusionMethods have been developed to plan IMRT treatments using XiO for delivery with a Beam Modulator? that fulfil demanding dose criteria, using many different set-ups. This study suggests that 6 MV photons can produce prostate IMRT plans that are comparable to those using 10 MV. Work is ongoing to develop a complete class solution.  相似文献   

4.
PurposeFlattening filter free (FFF) beams are frequently used for stereotactic body radiation therapy with various treatment modalities: conventional static fields, dynamic conformal arc (DCA) or Rapid Arc (RA). The goal of this study was to obtain some criteria to enable a conscious choice of the employment of FFF beams and of the DCA or RA technique, depending on the PTV size.Methods and materials24 PTVs from 1.52 cm3 to 445.24 cm3 were studied in various sites: virtual phantom, lung and liver. For each PTV, DCA and RA plans were prepared using two flattened (FF) and two unflattened photon beams. Parameters such as conformity index, gradient index, healthy-tissue and organs at risk mean doses, number of monitor units (MU), beam on time (BOT) were used to quantify obtained dose distributions. Friedman tests and Spearman’s rank correlation coefficients were also performed.ResultsNo significant differences were found between FF and FFF beams for RA regarding conformity and gradient indices. For DCA, 10FFF is less suitable and forward planning becomes more challenging as PTV volume increases. FFF beams provided a better sparing of healthy-tissues except for 10FFF used with DCA. 6FFF was slightly better than 10FFF in terms of healthy-tissue mean doses. FFF beams generated significantly reduced BOTs and increased MUs. These effects were more pronounced for larger volumes and especially for RA plans.ConclusionsFFF showed better results than FF beams for the considered plans. 10FFF used with DCA should be used with caution for medium and large volumes.  相似文献   

5.
Background and purposeTomoDirect (TD) can only operate in free-breathing. The purpose of this study is to compare TD with breath-hold 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) techniques for left breast treatments, and to determine if the lack of respiratory gating is a handicap for cardiac sparing.Materials and methods15 patients treated for left breast had two computed tomography simulation, in free breathing (FB) and in deep-inspiration breath-hold (DIBH). Four treatments were planned: TD-FB, 3DCRT-FB, 3DCRT-DIBH and IMRT-DIBH. Dose to PTV, heart, lungs, right breast and patient were compared.ResultsA slightly lower cardiac mean dose is found for 3DCRT-DIBH than for TD-FB group (1.99 Gy Vs 2.89 Gy, p = 0.0462), while no statistical difference is found for heart V20. TD-FB plans show the best PTV dose homogeneity (0.053, p < 0.001) and the lowest left lung mean dose (5.16 Gy, p < 0.001). No major differences are found for the other organs.ConclusionsTomoDirect and breath-hold 3DCRT are complementary techniques for left breast treatments: for a minority of patients, respiratory gating is mandatory to lower cardiac dose; for the remaining majority of patients, TomoDirect achieves better PTV homogeneity and reduced left lung dose, with cardiac dose equivalent to 3DCRT-DIBH.  相似文献   

6.
PurposeThis treatment planning study was conducted to determine whether spot scanning proton beam therapy (SSPT) reduces the risk of grade ⩾3 hematologic toxicity (HT3+) compared with intensity modulated radiation therapy (IMRT) for postoperative whole pelvic radiation therapy (WPRT).Methods and materialsThe normal tissue complication probability (NTCP) of the risk of HT3+ was used as an in silico surrogate marker in this analysis. IMRT and SSPT plans were created for 13 gynecologic malignancy patients who had received hysterectomies. The IMRT plans were generated using the 7-fields step and shoot technique. The SSPT plans were generated using anterior-posterior field with single field optimization. Using the relative biological effectives (RBE) value of 1.0 for IMRT and 1.1 for SSPT, the prescribed dose was 45 Gy(RBE) in 1.8 Gy(RBE) per fractions for 95% of the planning target volume (PTV). The homogeneity index (HI) and the conformity index (CI) of the PTV were also compared.ResultsThe bone marrow (BM) and femoral head doses using SSPT were significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of HT3+ using SSPT was significantly lower than with IMRT (NTCP = 0.04 ± 0.01 and 0.19 ± 0.03, p = 0.0002, respectively). There were no significant differences in the CI and HI of the PTV between IMRT and SSPT (CI = 0.97 ± 0.01 and 0.96 ± 0.02, p = 0.3177, and HI = 1.24 ± 0.11 and 1.27 ± 0.05, p = 0.8473, respectively).ConclusionThe SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT.  相似文献   

7.
PurposeStudies using split field IMRT to spare dysphagia/aspiration related structures (DARS) have raised concern regarding dose uncertainty at matchline. This study explores the utility of hybrid VMAT in sparing the DARS and assesses matchline dose uncertainty in postoperative oral cavity cancer patients and compares it with VMAT.Methods & materialsTen postoperative oral cavity cancer patients were planned with h-VMAT and VMAT using the same planning CT dataset. PTV and DARS were contoured using standard delineation guidelines. In h-VMAT 80% of the neck dose was planned using AP/PA technique and then VMAT optimization was done for the total PTV by keeping the corresponding AP/PA plan as the base dose. Planning goal for PTV was V95%  95% and for DARS, adequate sparing. Plans and dose volume histograms were analyzed using dosimetric indices. Absolute point and portal dose measurements were done for h-VMAT plans to verify dose at the matchline.ResultsCoverage in both the techniques was comparable. Significant differences were observed in mean doses to DARS (Larynx: 24.36 ± 2.51 versus 16.88 ± 2.41 Gy; p < 0.0006, Pharyngeal constrictors: 25.16 ± 2.41 versus 21.2 ± 2.1 Gy; p < 0.005, Esophageal inlet: 18.71 ± 2 versus 12.06 ± 0.79 Gy; p < 0.0002) favoring h-VMAT. Total MU in both the techniques was comparable. Average percentage variations in point dose measurements in h-VMAT done at +3.5 and −3.5 positions were (1.47 ± 1.48 and 2.28 ± 1.35%) respectively. Average gamma agreement for portal dose measured was 97.07%.Conclusionh-VMAT achieves better sparing of DARS with no matchline dose uncertainty. Since these patients have swallowing dysfunction post-operatively, attempts should be made to spare these critical structures as much as possible.  相似文献   

8.
PurposeTo assess the dosimetric impact of a patient positioning device for prone breast radiotherapy and assess the accuracy of a treatment planning system (TPS) in predicting this impact.MethodsBeam attenuation and build-up dose perturbations, quantified by ionization chamber and radiochromic film dosimetry, were evaluated for 3 components of the patient positioning device: the carbon fiber baseplate, the support cushions and the support wedge for the contralateral breast. Dose calculations were performed using the XVMC dose engine implemented in the Monaco TPS. All components were included during planning CT acquisition.ResultsBeam attenuation amounted to 7.57% (6 MV) and 5.33% (15 MV) for beams obliquely intersecting the couchtop–baseplate combination. Beams traversing large sections of the support wedge were attenuated by 12.28% (6 MV) and 9.37% (15 MV). For the support cushion foam, beam attenuation remained limited to 0.11% (6 MV) and 0.08% (15 MV) per centimeter thickness. A substantial loss of dose build-up was detected when irradiating through any of the investigated components. TPS dose calculations accurately predicted beam attenuation by the baseplate and support wedge. A manual density overwrite was needed to model attenuation by the support cushion foam. TPS dose calculations in build-up regions differed considerably from measurements for both open beams and beams traversing the device components.ConclusionsIrradiating through the components of the positioning device resulted in a considerable degradation of skin sparing. Inclusion of the device components in the treatment planning CT allowed to accurately model the most important attenuation effect, but failed to accurately predict build-up doses.  相似文献   

9.
PurposeA retrospective planning study was undertaken to evaluate the dosimetric advantages of the irregular surface compensator (ISC) technique, a forward planning technique with electronic compensation algorithm available on Varian Eclipse treatment planning system. This was extensively compared to the conventional four-field box (4FB) and intensity modulated radiation therapy using 5 fields (IMRT5F) on gynecologic cancer patients.MethodsTwenty-two patients were enrolled. The prescribed dose was 50.4 Gy in 28 fractions to the primary target including pelvic lymph nodes. 4FB treatment plans were generated, then fluence of anterior and posterior fields were modified to generate ISC plans. IMRT5F were inversely optimized with equally spaced five coplanar fields. Dose-volume parameters were evaluated for the comparison of three planning techniques. The MU and delivery time were also estimated.ResultsIn terms of target coverage, the conformity and homogeneity index of ISC (1.67 and 1.03, respectively) were superior to those of 4FB (2.43 and 1.06, respectively) but slightly inferior to those of IMRT5F (1.10 and 1.02, respectively). ISC also illustrated an overall improvement in normal organ saving. Compared to 4FB, the mean dose of the rectum was reduced by about 4.0–5.0 Gy with ISC and IMRT5F. The volume receiving large doses was reduced for bladder with statistical significance with ISC and more with IMRT5F relative to 4FB. The mean number of MU per fraction were 200.86 (4FB), 446.09 (ISC) and 895.59 (IMRT5F).ConclusionThe ISC technique has the superior target coverage and healthy tissue sparing in comparison with conventional 4FB and comparable normal organ saving compared to IMRT5F. The ISC can be an available option for gynecologic radiotherapy.  相似文献   

10.
AimTo report a single-institution experience using postoperative pelvic Intensity Modulation Radiation Therapy (IMRT) using tomotherapy accelerators (TA) in postoperative endometrial cancer (EC) regarding ICRU 83 recommendations.BackgroundIMRT in gynecological malignancies provides excellent dosimetric data, lower rates of adverse events and clinical data similar to historical series.Material and methodsSeventy-six patients with EC were postoperatively treated with adjuvant IMRT using TA. The IMRT dose was 45 Gy for patients without positive lymph nodes and Type I histology and 50.4 Gy for patients with positive lymph nodes and/or type II histology.ResultsWith a median follow-up of 29 months, the 12- and 24-month Overall Survival (OS) and Disease-Free Survival (DFS) were 96%, 93%, 87%, and 74%, respectively. Age of less than 60 years was associated with better OS (HR: 8.9; CI: 1.1–68) and DFS (HR: 3.5; CI: 1.2–10.2). Patients with Type II and Type I Grade III histology had a worse OS (HR: 3.3; CI: 1.1–11). Five women (6.6%) presented in-field local vaginal recurrence, 2 (2.6%) presented non-in-field vaginal recurrence, 4 (5.2%) presented pelvic node and distant recurrence and 11 (14.4%) presented only distant metastases. One patient stopped radiation treatment due to Grade III acute diarrhea. No Grade III late toxicity was observed. Planning Target Volume (PTV) coverage showed mean D2, D50, D95, and D98 of 51.64–46.23 Gy, 49.49–44.97 Gy, 48.62–43.96 Gy, and 48.47–43.58 Gy for patients who received 45 and 50.4 Gy, respectively.ConclusionsIMRT with TA in postoperative EC shows excellent conformity and homogeneity of PTV dose. Without Grade III late toxicity, data from this cohort demonstrated the utility of IMRT.  相似文献   

11.
AimThis study aimed to investigate whether IMRT using VMAT is a viable and safe solution in dose escalated RT in these patients.BackgroundAn increasing number of prostate cancer patients are elderly and have hip prostheses. These implants pose challenges in radiotherapy treatment planning. Although intensity modulated radiotherapy (IMRT) is commonly used, there is a lack of clinical studies documenting its efficacy and toxicities in this subgroup of patients.Materials and methodsThe data from 23 patients with hip prostheses and non-metastatic prostate cancer treated with VMAT (volumetric modulated arc therapy) between 2009 and 2011, were retrospectively analyzed. Baseline characteristics, treatment details and outcome data were collected on all patients. The median follow up was 40.9 months. MRI-CT image fusion was performed and the treatment plans were created using RapidArc™ (RA) techniques utilizing 1 or 2 arcs and 10 MV photon beams.Results96% of patients were treated with a dose of 72 Gy/32 fractions over 44 days. 21/23 plans met the PTV targets. The mean homogeneity index was 1.07. 20/23 plans met all OAR constraints (rectum, bladder). Two plans deviated from rectal constraints, four from bladder constraints; all were classed as minor deviations. One patient experienced late grade 3 genitourinary toxicity. Three other patients experienced late grade 2 or lower gastrointestinal toxicity. One patient had biochemical failure and one had a non-prostate cancer related death.ConclusionsVMAT provides an elegant solution to deliver dose escalated RT in patients with unilateral and bilateral hip replacements with minimal acute and late toxicities.  相似文献   

12.
PurposeTo study the impact of setup errors on the dose to the target volume and critical structures in the treatment of cancer of nasopharynx with intensity modulated radiation therapy (IMRT).Methods and materialsTwelve patients of carcinoma of nasopharynx treated by IMRT with simultaneous integrated boost technique were enrolled. The gross tumor volume, clinical target volume and low-risk nodal region were planned for 70, 59.4 and 54 Gy, respectively, in 33 fractions. Based on the constraints, treatment plans were generated. Keeping it as the base plan, the patient setup error was simulated for 3, 5 and 10 mm by shifting the isocenter in all three directions viz. anterior, posterior, superior, inferior, right and left lateral. The plans were evaluated for mean dose, maximum dose, volume of PTV receiving >110% and <93% of the prescribed dose. For both the parotids, the mean dose and the dose received by >50% of the parotid were evaluated. The maximum dose and dose received by 2 cc of spinal cord were also analyzed.ResultsThe dose to the target volume decreases gradually with increase in setup error. The superior and inferior shifts play major role in tumor under-dosage. A setup error of 3 mm along the posterior and lateral directions significantly affects the dose to the spinal cord. Similarly, setup error along lateral and anterior directions affects the dose to both parotids.ConclusionsThe isocenter position should be verified regularly to ensure that the goal of IMRT is achieved.  相似文献   

13.
PurposeThe log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error.Methods and materialsModified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5 mm in opposite directions and systematic leaf shifts: ±1.0 mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.ResultsFor MLC leaves calibrated within ±0.5 mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32 ± 0.27% and 0.82 ± 0.17 Gy for PTV and spinal cord, respectively, and in prostate plans 1.22 ± 0.36%, 0.95 ± 0.14 Gy, and 0.45 ± 0.08 Gy for PTV, rectum, and bladder, respectively.ConclusionsIn this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.  相似文献   

14.
15.
16.
17.
18.
AimThe aim of this study was to estimate the secondary malignancy risk from the radiation in FFB prostate linac-based radiotherapy for different organs of the patient.BackgroundRadiation therapy is one of the main procedures of cancer treatment. However, the application the radiation may impose dose to organs of the patient which can be the cause of some malignancies.Materials and methodsMonte Carlo (MC) simulation was used to calculate radiation doses to patient organs in 18 MV linear accelerator (linac) based radiotherapy. A humanoid MC phantom was used to calculate the equivalent dose s for different organs and probability of secondary cancer, fatal and nonfatal risk, and other risks and parameters related to megavoltage radiation therapy. In out-of-field radiation calculation, it could be seen that neutrons imparted a higher dose to distant organs, and the dose to surrounding organs was mainly due to absorbed scattered photons and electron contamination.ResultsOur results showed that the bladder and skin with 54.89 × 10−3 mSv/Gy and 46.09 × 10−3 mSv/Gy, respectively, absorbed the highest equivalent dose s from photoneutrons, while a lower dose was absorbed by the lung at 3.42 × 10−3 mSv/Gy. The large intestine and bladder absorbed 55.00 × 10−3 mSv/Gy and 49.08 × 10−3, respectively, which were the highest equivalent dose s due to photons. The brain absorbed the lowest out-of-field dose, at 1.87 × 10−3 mSv/Gy.ConclusionsWe concluded that secondary neutron portion was higher than other radiation. Then, we recommended more attention to neutrons in the radiation protection in linac based high energy radiotherapy.  相似文献   

19.
PurposeStereotactic body image guided radiation therapy (SBRT) shows good results for lung cancer treatment. Better normal tissue sparing might be achieved with scanned carbon ion therapy (PT). Therefore an in silico trial was conducted to find potential advantages of and patients suited for PT.MethodsFor 19 patients treated with SBRT, PT plans were calculated on 4D-CTs with simulated breathing motion. Prescribed single fraction dose was 24 Gy and OAR constraints used for photon planning were respected. Motion was mitigated by rescanning and range-adapted ITVs. Doses were compared to the original SBRT plans.ResultsCTV coverage was the same in SBRT and PT. The field-specific PTV including range margins for PT was 1.5 (median, 25–75% 1.3–2.1) times larger than for SBRT. Nevertheless, maximum point dose and mean dose in OARs were higher in SBRT by 2.8 (1.6–3.7) Gy and 0.7 (0.3–1.6) Gy, respectively. Patients with a CTV >2.5 cc or with multiple lung lesions showed larger differences in OAR doses in favor of PT.ConclusionsPatients receive less dose in critical OARs such as heart, spinal cord, esophagus, trachea and aorta with PT, while maintaining the same target coverage. Patients with multiple or larger lesions are particularly suited for PT.  相似文献   

20.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号