首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Positron emission tomography (PET) is well established as an important research and clinical molecular imaging modality. Although the size differences between humans and rodents create formidable challenges for the application of PET imaging in small animals, advances in technology over the past several years have enabled the translation of this imaging modality to preclinical applications. In this article we discuss the basic principles of PET instrumentation and radiopharmaceuticals, and examine the key factors responsible for the qualitative and quantitative imaging capabilities of small animal PET systems. We describe the criteria that PET imaging agents must meet, and provide examples of small animal PET imaging to give the reader a broad perspective on the capabilities and limitations of this evolving technology. A crucial driver for future advances in PET imaging is the availability of molecular imaging probes labeled with positron-emitting radionuclides. The strong translational science potential of small animal and human PET holds great promise to dramatically advance our understanding of human disease. The assessment of molecular and functional processes using imaging agents as either direct or surrogate biomarkers will ultimately enable the characterization of disease expression in individual patients and thus facilitate tailored treatment plans that can be monitored for their effectiveness in each subject.  相似文献   

2.
Positron emission tomography (PET) neuroimaging and behavioral assays in rodents are widely used in neuroscience. PET gives insights into the molecular processes of neuronal communication, and behavioral methods analyze the actions that are associated with such processes. These methods have not been directly integrated, because PET studies in animals have until now required general anesthesia to immobilize the subject, which precludes behavioral studies. We present a method for imaging awake, behaving rats with PET that allows the simultaneous study of behavior. Key components include the 'rat conscious animal PET' or RatCAP, a miniature portable PET scanner that is mounted on the rat's head, a mobility system that allows considerable freedom of movement, radiotracer administration techniques and methods for quantifying behavior and correlating the two data sets. The simultaneity of the PET and behavioral data provides a multidimensional tool for studying the functions of different brain regions and their molecular constituents.  相似文献   

3.
Positron emission tomography (PET) is a non-invasive molecular imaging technique using positron-emitting radioisotopes to study functional processes within the body. High resolution PET scanners designed for imaging rodents and non-human primates are now commonplace in preclinical research. Brain imaging in this context, with motion compensation, can potentially enhance the usefulness of PET by avoiding confounds due to anaesthetic drugs and enabling freely moving animals to be imaged during normal and evoked behaviours. Due to the frequent and rapid motion exhibited by alert, awake animals, optimal motion correction requires frequently sampled pose information and precise synchronisation of these data with events in the PET coincidence data stream. Motion measurements should also be as accurate as possible to avoid degrading the excellent spatial resolution provided by state-of-the-art scanners. Here we describe and validate methods for optimised motion tracking suited to the correction of motion in awake rats. A hardware based synchronisation approach is used to achieve temporal alignment of tracker and scanner data to within 10 ms. We explored the impact of motion tracker synchronisation error, pose sampling rate, rate of motion, and marker size on motion correction accuracy. With accurate synchronisation (<100 ms error), a sampling rate of >20 Hz, and a small head marker suitable for awake animal studies, excellent motion correction results were obtained in phantom studies with a variety of continuous motion patterns, including realistic rat motion (<5% bias in mean concentration). Feasibility of the approach was also demonstrated in an awake rat study. We conclude that motion tracking parameters needed for effective motion correction in preclinical brain imaging of awake rats are achievable in the laboratory setting. This could broaden the scope of animal experiments currently possible with PET.  相似文献   

4.
The enormous advances in our understanding of the progression of diseases at the molecular level have been supplemented by the new field of ‘molecular imaging’, which provides for in vivo visualization of molecular events at the cellular level in living organisms. Molecular imaging is a noninvasive assessment of gene and protein function, protein–protein interaction and/or signal transduction pathways in animal models of human disease and in patients to provide insights into molecular pathogenesis. Five major imaging techniques are currently available to assess the structural and functional alterations in vivo in small animals. These are (i) optical bioluminescence and fluorescence imaging techniques, (ii) radionuclide-based positron emission tomography (PET) and single photon emitted computed tomography (SPECT), (iii) X-ray-based computed tomography (CT), (iv) magnetic resonance imaging (MRI) and (v) ultrasound imaging (US). Functional molecular imaging requires an imaging probe that is specific for a given molecular event. In preclinical imaging, involving small animal models, the imaging probe could be an element of a direct (‘direct imaging’) or an indirect (‘indirect imaging’) event. Reporter genes are essential for indirect imaging and provide a general integrated platform for many different applications. Applications of multimodality imaging using combinations of bioluminescent, fluorescent and PET reporter genes in unified fusion vectors developed by us for recording events from single live cells to whole animals with high sensitivity and accurate quantification are discussed. Such approaches have immense potential to track progression of metastasis, immune cell trafficking, stem cell therapy, transgenic animals and even molecular interactions in living subjects.  相似文献   

5.
Bergmann R  Pietzsch J 《Amino acids》2005,29(4):355-376
Summary. Positron emission tomography (PET) is a 3-dimensional imaging technique that has undergone tremendous developments during the last decade. Non-invasive tracing of molecular pathways in vivo is the key capability of PET. It has become an important tool in the diagnosis of human diseases as well as in biomedical and pharmaceutical research. In contrast to other imaging modalities, radiotracer concentrations can be determined quantitatively. By application of appropriate tracer kinetic models, the rate constants of numerous different biological processes can be determined. Rapid progress in PET radiochemistry has significantly increased the number of biologically important molecules labelled with PET nuclides to target a broader range of physiologic, metabolic, and molecular pathways. Progress in PET physics and technology strongly contributed to better scanners and image processing. In this context, dedicated high resolution scanners for dynamic PET studies in small laboratory animals are now available. These developments represent the driving force for the expansion of PET methodology into new areas of life sciences including food sciences. Small animal PET has a high potential to depict physiologic processes like absorption, distribution, metabolism, elimination and interactions of biologically significant substances, including nutrients, ‘nutriceuticals’, functional food ingredients, and foodborne toxicants. Based on present data, potential applications of small animal PET in food sciences are discussed.  相似文献   

6.
A variety of techniques have been developed to analyze protein-protein interactions in vitro and in cultured cells. However, these methods do not determine how protein interactions affect and are regulated by physiologic and pathophysiologic conditions in living animals. This article describes methodology for detecting and quantifying protein interactions in living mice, using an inducible two-hybrid system developed for positron emission tomography (PET) imaging. We discuss the methods to establish stably transfected cells with components of the imaging system, create tumor xenografts, synthesize PET radiopharmaceuticals used to visualize the imaging reporter, perform microPET imaging, and analyze data from imaging studies. Development and application of technologies for molecular imaging of protein-protein interactions in vivo should enable researchers to investigate intrinsic binding specificities of proteins during normal development and disease progression as well as aid drug development through direct interrogation of molecular targets within intact animals.  相似文献   

7.

Introduction  

The purpose of this work was to establish and validate combined small animal positron emission tomography - computed tomography (PET/CT) as a new in vivo imaging method for visualisation and quantification of joint inflammation.  相似文献   

8.
The CB1 cannabinoid receptor is expressed in the brain at levels sufficient to serve as potential target for in vivo imaging using positron emission tomography (PET) or single photon emission computed tomography methodology. To date, the most promising radioligands for the in vivo imaging of this receptor have structures based on that of the cannabinoid antagonist, SR141716A. Rodent data obtained using these in vivo radiotracers has demonstrated that both the behavioral and neurochemical effects of cannabinoids occur at very low levels of receptor occupancy. More recently, an agonist radiotracer based on the structure of aminoalkylindole cannabinoids has also been examined for in vivo labeling of CB1 receptors. Although rodent studies have indicated that in vivo imaging of CB1 receptors is feasible, at the present time this receptor has still to be successful imaged in a human PET study.  相似文献   

9.
Dedicated high-resolution small animal systems have recently emerged as important new tools for laboratory animal research. These imaging systems permit researchers to noninvasively screen animal models for mutations or pathologies and to monitor disease progression and response to therapy. The authors survey various small animal imaging modalities, including MRI, PET, SPECT, and microCT, and discuss several representative microCT mouse imaging studies.  相似文献   

10.
Non-invasive longitudinal detection and evaluation of gene expression in living animals can provide investigators with an understanding of the ontogeny of a gene's biological function(s). Currently, mouse model systems are used to optimize magnetic resonance imaging (MRI), positron emission tomography (PET), single-photon emission computed tomography (SPECT), and optical imaging modalities to detect gene expression and protein function. These molecular imaging strategies are being developed to assess tumor growth and the tumor microenvironment. In addition, pre-labeling of progenitor cells can provide invaluable information about the developmental lineage of stem cells both in organogenesis and tumorigenesis. The feasibility of this approach has been extensively tested by targeting of endogenous tumor cell receptors with labeled ligand (or ligand analog) reporters and targeting enzymes with labeled substrate (or substrate analog). We will primarily discuss MRI, PET, and SPECT imaging of cell surface receptors and the feasibility of non-invasive imaging of gene expression using the tumor microenvironment (e.g., hypoxia) as a conditional regulator of gene expression.  相似文献   

11.
Multimodality in vivo molecular-genetic imaging   总被引:7,自引:0,他引:7  
Multimodality imaging is increasingly being used in molecular-genetic studies in small animals. The coupling of nuclear and optical reporter genes represents the beginning of a far wider application of this technology. Optical imaging and optical reporter systems are cost-effective and time-efficient, they require less resources and space than PET or MRI, and they are particularly well suited for small animal imaging and for in vitro assays to validate different reporter systems. However, optical imaging techniques are limited by depth of light penetration and scatter and do not yet provide optimal quantitative or tomographic information. These issues are not limiting for PET- or MRI-based reporter systems, and PET- and MRI-based animal studies are more easily generalized to human applications. Many of the shortcomings of each modality alone can be overcome by the use of dual- or triple-modality reporter constructs that incorporate the opportunity for PET, fluorescence and bioluminescence imaging. We optimistically expect that some form of tomographic, small animal optical imaging capability will be developed soon, and that this will provide the opportunity for the colocalization of optical signals to anatomical structures provided by tomographic CT and MR imaging.  相似文献   

12.
13.
Three-dimensional micro computed tomography (microCT) offers the opportunity to capture images liver structures and lesions in mice with a high spatial resolution. Non-invasive microCT allows for accurate calculation of vessel tortuosity and density, as well as liver lesion volume and distribution. Longitudinal monitoring of liver lesions is also possible. However, distinguishing liver lesions from variations within a normal liver is impossible by microCT without the use of liver- or tumor-specific contrast-enhancing agents. The combination of microCT for morphologic imaging with functional imaging, such as positron emission tomography (PET) or single photon emission tomography (SPECT), offers the opportunity for better abdominal imaging and assessment of structure discrepancies visible by functional imaging.This paper describes methods of current microCT imaging options for imaging of liver lesions compared to other imaging techniques in small animals.  相似文献   

14.
Liver cancer is the fifth most common cause of cancer deaths worldwide. Noninvasive diagnosis is difficult and the disease heterogeneity reduces the accuracy of pathological assays. Improvement in diagnostic imaging of specific molecular disease markers has provided hope for accurate and early noninvasive detection of liver cancer. However, all current imaging technologies, including ultrasonography, computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging, are not specific targets for detection of liver cancer. The aim of this study was to test the feasibility of injecting a cocktail of specific molecular imaging agents to noninvasively image liver cancer. The target-specific cocktail contained agents for imaging the neovasculature (RGD peptide), matrix metalloproteinase (MMP), and glucose transport (18F-fluorodeoxyglucose [18F-FDG]). Imaging studies were performed in liver cancer cells and xenograft models. The distribution of MMP at the intracellular level was imaged by confocal microscopy. RGD, MMP, and 18F-FDG were imaged on tumor-bearing mice using PET, CT, X-ray, and multi-wavelength optical imaging modalities. Image data demonstrated that each agent bound to a specific disease target component. The same liver cancer xenograft contained multiple disease markers. Those disease markers were heterogenetically distributed in the same tumor nodule. The molecular imaging agents had different distributions in the whole body and inside the tumor nodule. All target-specific agents yielded high tumor-to-background ratios after injection. In conclusion, target-specific molecular imaging agents can be used to study liver cancer in vitro and in vivo. Noninvasive multimodal/multi-target-specific molecular imaging agents could provide tools to simultaneously study multiple liver cancer components.  相似文献   

15.
OBJECTIVE--To compare computed tomography and magnetic resonance imaging in investigating patients suspected of having a lesion in the posterior cranial fossa. DESIGN--Randomised allocation of newly referred patients to undergo either computed tomography or magnetic resonance imaging; the alternative investigation was performed subsequently only in response to a request from the referring doctor. SETTING--A regional neuroscience centre serving 2.7 million. PATIENTS--1020 Patients recruited between April 1986 and December 1987, all suspected by neurologists, neurosurgeons, or other specialists of having a lesion in the posterior fossa and referred for neuroradiology. The groups allocated to undergo computed tomography or magnetic resonance imaging were well matched in distributions of age, sex, specialty of referring doctor, investigation as an inpatient or an outpatient, suspected site of lesion, and presumed disease process; the referring doctor''s confidence in the initial clinical diagnosis was also similar. INTERVENTIONS--After the patients had been imaged by either computed tomography or magnetic resonance (using a resistive magnet of 0.15 T) doctors were given the radiologist''s report and a form asking if they considered that imaging with the alternative technique was necessary and, if so, why; it also asked for their current diagnoses and their confidence in them. MAIN OUTCOME MEASURES--Number of requests for the alternative method of investigation. Assessment of characteristics of patients for whom further imaging was requested and lesions that were suspected initially and how the results of the second imaging affected clinicians'' and radiologists'' opinions. RESULTS--Ninety three of the 501 patients who initially underwent computed tomography were referred subsequently for magnetic resonance imaging whereas only 28 of the 493 patients who initially underwent magnetic resonance imaging were referred subsequently for computed tomography. Over the study the number of patients referred for magnetic resonance imaging after computed tomography increased but requests for computed tomography after magnetic resonance imaging decreased. The reason that clinicians gave most commonly for requesting further imaging by magnetic resonance was that the results of the initial computed tomography failed to exclude their suspected diagnosis (64 patients). This was less common in patients investigated initially by magnetic resonance imaging (eight patients). Management of 28 patients (6%) imaged initially with computed tomography and 12 patients (2%) imaged initially with magnetic resonance was changed on the basis of the results of the alternative imaging. CONCLUSIONS--Magnetic resonance imaging provided doctors with the information required to manage patients suspected of having a lesion in the posterior fossa more commonly than computed tomography, but computed tomography alone was satisfactory in 80% of cases...  相似文献   

16.
The ability to successfully intubate the trachea of mice and control their ventilation is important for longitudinal studies requiring recovery from anesthesia and repeated pulmonary function measurements or other evaluations, such as the use of radiological imaging (e.g., computed tomography or magnetic resonance imaging). We describe a method for rapid and repeated intubation of mice, with subsequent pulmonary function measurements at baseline and after an agonist challenge. We describe a simply constructed metal blade used as a laryngoscope to facilitate oropharyngeal exposure, transillumination of the neck to facilitate visualization of the trachea through the oropharynx, readily available polyethylene tubing to intubate the trachea, and a simple solenoid ventilator to maintain physiological ventilation and assess respiratory resistance and compliance. Brief infusions of acetylcholine through a needle into the jugular vein are used to assess the responsiveness of the airway smooth muscle.  相似文献   

17.
The underlying principles of nuclear medicine imaging involve the use of unsealed sources of radioactivity in the form of radiopharmaceuticals. The ionizing radiations that accompany the decay of the administered radioactivity can be quantitatively detected, measured, and imaged in vivo with instruments such as gamma cameras. This paper reviews the design and operating principles, as well as the capabilities and limitations, of instruments used clinically and preclinically for in vivo radionuclide imaging. These include gamma cameras, single-photon emission computed tomography (SPECT) scanners, and positron emission tomography (PET) scanners. The technical basis of autoradiography is reviewed as well.  相似文献   

18.
We hypothesized that imaging-based assessment of cellular proliferation in prostate cancer may improve tumor characterization. We therefore evaluated the biodistribution and effect of androgen on tumor uptake of the cellular proliferation imaging marker [(18)F]-2'-fluoro-5-methyl-1-beta-D-arabinofuranosyluracil ((18)F-FMAU) in xenograft mouse models of human prostate cancer. Castrated and noncastrated athymic male mice were implanted with androgen-independent PC3 and androgen-sensitive CWR22 human prostate cancer cells. Dynamic micro-positron emission tomography (PET)/computed tomography was performed for 1 hour followed by 10-minute static scans at 2 and 3 hours. Animals were sacrificed after imaging for biodistribution studies and immunohistochemical staining of tumors for androgen receptor and Ki-67/MIB expression. (18)F-FMAU uptake was significantly higher in all major organs of the castrated animals in comparison with noncastrated mice, with the highest uptake in liver and the lowest uptake in muscle and bone. When compared to PC3 tumors, CWR22 xenografts showed significantly higher tumor to muscle (2.56 ± 0.30 vs 1.99 ± 0.30, p = .008) and tumor to liver (1.72 ± 0.12 vs 1.26 ± 0.17, p = .0003) uptake ratios in the noncastrated animal at the 3-hour time point. Androgen receptor and Ki-67/MIB expressions were higher in CWR22 than in PC3 xenografts. Our initial preclinical observations suggest that there may be an association between androgen signaling and thymidine metabolism and that (18)F-FMAU PET may be useful in prostate tumor characterization.  相似文献   

19.
The introduction of neural stem cells into the brain has promising therapeutic potential for the treatment of neurodegenerative diseases. To monitor the cellular replacement therapy, that is, to determine stem cell migration, survival, and differentiation, in vivo tracking methods are needed. Ideally, these tracking methods are noninvasive. Noninvasive tracking methods that have been successfully used for the visualization of blood-derived progenitor cells include magnetic resonance imaging and radionuclide imaging using single-photon emission computed tomography (SPECT) and positron emission tomography (PET). The SPECT tracer In-111-oxine is suitable for stem cell labeling, but for studies in small animals, the higher sensitivity and facile quantification that can be obtained with PET are preferred. Here the potential of 2'-[18F]fluoro-2'-deoxy-D-glucose ([18F]-FDG), a PET tracer, for tracking of neural stem cell (NSCs) trafficking toward an inflammation site was investigated. [18F]-FDG turns out to be a poor radiopharmaceutical to label NSCs owing to the low labeling efficiency and substantial release of radioactivity from these cells. Efflux of [18F]-FDG from NSCs can be effectively reduced by phloretin in vitro, but inhibition of tracer release is insufficient in vivo for accurate monitoring of stem cell trafficking.  相似文献   

20.
The biological events associated with mammalian reproductive processes are highly dynamic and tightly regulated by molecular, genetic, and biomechanical factors. Implementation of live imaging in reproductive research is vital for the advancement of our understanding of normal reproductive physiology and for improving the management of reproductive disorders. Optical coherence tomography (OCT) is emerging as a promising tool for dynamic volumetric imaging of various reproductive processes in mice and other animal models. In this review, we summarize recent studies employing OCT-based approaches toward the investigation of reproductive processes in both, males and females. We describe how OCT can be applied to study structural features of the male reproductive system and sperm transport through the male reproductive tract. We review OCT applications for in vitro and dynamic in vivo imaging of the female reproductive system, staging and tracking of oocytes and embryos, and investigations of the oocyte/embryo transport through the oviduct. We describe how the functional OCT approach can be applied to the analysis of cilia dynamics within the male and female reproductive systems. We also discuss the areas of research, where OCT could find potential applications to progress our understanding of normal reproductive physiology and reproductive disorders.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号