共查询到20条相似文献,搜索用时 31 毫秒
1.
Preeti Gupta Elizabeth Sidhartha Michael J. A. Girard Jean Martial Mari Tien-Yin Wong Ching-Yu Cheng 《PloS one》2014,9(5)
Purpose
To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT).Methods
We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses.Results
Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively.Conclusions
The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement. 相似文献2.
Florian Alten Jeremias Motte Carina Ewering Nani Osada Christoph R. Clemens Ella M. Kadas Nicole Eter Friedemann Paul Martin Marziniak 《PloS one》2014,9(11)
Purpose
To further elucidate retinal findings and retinal vessel changes in Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) patients by means of high resolution retinal imaging.Methods
28 eyes of fourteen CADASIL patients and an equal number of control subjects underwent confocal scanning laser ophthalmoscopy (cSLO), spectral-domain optical coherence tomography (SD-OCT), retinal nerve fibre layer (RNFL) measurements, fluorescein and indocyanine angiography. Three vessel measurement techniques were applied: RNFL thickness, a semiautomatic software tool based on cSLO images and manual vessel outlining based on SD-OCT.Results
Mean age of patients was 56.2±11.6 years. Arteriovenous nicking was present in 22 (78.6%) eyes and venous dilation in 24 (85.7%) eyes. Retinal volume and choroidal volume were 8.77±0.46 mm3 and 8.83±2.24 mm3. RNFL measurements showed a global increase of 105.2 µm (Control group: 98.4 µm; p = 0.015). Based on semi-automatic cSLO measurements, maximum diameters of arteries and veins were 102.5 µm (106.0 µm; p = 0.21) and 128.6 µm (124.4 µm; p = 0.27) respectively. Manual SD-OCT measurements revealed significantly increased mean arterial 138.7 µm (125.4 µm; p<0.001) and venous 160.0 µm (146.9; p = 0.003) outer diameters as well as mean arterial 27.4 µm (19.2 µm; p<0.001) and venous 18.3 µm (15.7 µm; p<0.001) wall thicknesses in CADASIL patients.Conclusions
The findings reflect current knowledge on pathophysiologic changes in vessel morphology in CADASIL patients. SD-OCT may serve as a complementary tool to diagnose and follow-up patients suffering from cerebral small-vessel diseases. 相似文献3.
Robert M. Kwee Alexander K. Dik Meindert N. Sosef Ralph C. M. Berendsen Sander Sassen Guido Lammering Ruud Clarijs Liekele E. Oostenbrug Rachel L. G. M. Blom Roy F. A. Vliegen 《PloS one》2014,9(4)
Objective
To investigate the reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) in assessing tumor response early in the course of neoadjuvant chemoradiotherapy in patients with operable esophageal cancer.Methods
Eleven male patients (mean age 54.8 years) with newly diagnosed esophageal cancer underwent DW-MRI before and 10 days after start of chemoradiotherapy. Reproducibility of apparent diffusion coefficient (ADC) measurements by manual (freehand) and semi-automated volumetric methods was assessed.Results
Interobserver reproducibility for the assessment of mean tumor ADC by the manual measurement method was good, with an ICC of 0.69 (95% CI, 0.36 to 0.85; P = 0.001). Interobserver reproducibility for the assessment of mean tumor ADC by the semi-automated volumetric measurement method was very good, with an ICC of 0.96 (95% CI, 0.91 to 0.98; P<0.001).Conclusion
Semi-automated volumetric ADC measurements have higher reproducibility than manual ADC measurements in assessing tumor response to chemoradiotherapy in patients with esophageal adenocarcinoma. 相似文献4.
Purpose
To study the factors that may affect reading speed in patients with diabetic macular edema previously treated with laser photocoagulation.Methods
Consecutive patients with type II diabetes treated with laser photocoagulation for diabetic macular edema (DME) at least twelve months previously, with best corrected visual acuity of better than 65 letters (approximately 20/40) measured with Early Treatment Diabetic Retinopathy Study (ETDRS) charts were included in this study. Patients previously treated with pan-retinal photocoagulation, vitrectomy, intravitreal steroid or anti-VEGF therapy were excluded. Any other ocular co-morbidities that may influence reading ability such as cataract, glaucoma or macular degeneration were also excluded. All patients were refracted by a certified examiner, the following measurements were collected: best corrected visual acuity (BCVA), contrast sensitivity with Pelli-Robson chart, reading speed with MNREAD chart, microperimetry with Nidek MP1, and central subfield thickness with Zeiss spectral domain optical coherent topography.Results
The slow reading group had poorer contrast sensitivity (p = 0.001), reduced retinal sensitivity (p = 0.027) and less stable fixation (p = 0.013). Most interestingly the reduced retinal sensitivity findings were driven by the microperimetry value on the right subfield (p = 0.033), (nasal to the fovea in the right eye and temporal to the fovea in the left eye). Multiple linear regression analysis showed that contrast sensitivity is probably the most important factor that affects reading speed (p = 0.001).Conclusion
Reduced retinal sensitivity after laser treatment is associated with reduced reading speed in patients with diabetic macular edema. 相似文献5.
Prema Sriram Chenyu Wang Con Yiannikas Raymond Garrick Michael Barnett John Parratt Stuart L. Graham Hemamalini Arvind Alexander Klistorner 《PloS one》2014,9(8)
Purpose
Loss of retinal ganglion cells in in non-optic neuritis eyes of Multiple Sclerosis patients (MS-NON) has recently been demonstrated. However, the pathological basis of this loss at present is not clear. Therefore, the aim of the current study was to investigate associations of clinical (high and low contrast visual acuity) and electrophysiological (electroretinogram and multifocal Visual Evoked Potentials) measures of the visual pathway with neuronal and axonal loss of RGC in order to better understand the nature of this loss.Methods
Sixty-two patients with relapsing remitting multiple sclerosis with no previous history of optic neuritis in at least one eye were enrolled. All patients underwent a detailed ophthalmological examination in addition to low contrast visual acuity, Optical Coherence Tomography, full field electroretinogram (ERG) and multifocal visual evoked potentials (mfVEP).Results
There was significant reduction of ganglion cell layer thickness, and total and temporal retinal nerve fibre layer (RNFL) thickness (p<0.0001, 0.002 and 0.0002 respectively). Multifocal VEP also demonstrated significant amplitude reduction and latency delay (p<0.0001 for both). Ganglion cell layer thickness, total and temporal RNFL thickness inversely correlated with mfVEP latency (r = −0.48, p<0.0001 respectively; r = −0.53, p<0.0001 and r = −0.59, p<0.0001 respectively). Ganglion cell layer thickness, total and temporal RNFL thickness also inversely correlated with the photopic b-wave latency (r = −0.35, p = 0.01; r = −0.33, p = 0.025; r = −0.36, p = 0.008 respectively). Multivariate linear regression model demonstrated that while both factors were significantly associated with RGC axonal and neuronal loss, the estimated predictive power of the posterior visual pathway damage was considerably larger compare to retinal dysfunction.Conclusion
The results of our study demonstrated significant association of RGC axonal and neuronal loss in NON-eyes of MS patients with both retinal dysfunction and post-chiasmal damage of the visual pathway. 相似文献6.
Seung Chai Jung Seung Hong Choi Jeong A. Yeom Ji-Hoon Kim Inseon Ryoo Soo Chin Kim Hwaseon Shin A. Leum Lee Tae Jin Yun Chul-Kee Park Chul-Ho Sohn Sung-Hye Park 《PloS one》2013,8(8)
Purpose
To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.Materials and Methods
Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.Results
Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.Conclusion
The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas. 相似文献7.
Vincent Daien Isabelle Carriere Ryo Kawasaki Jean-Paul Cristol Max Villain Pierre Fesler Karen Ritchie Cecile Delcourt 《PloS one》2013,8(7)
Purpose
Retinal vascular caliber has been linked with increased cardiovascular risk and is predictive of cardiovascular pathology, including stroke and coronary heart disease. Oxidative stress, as well as inflammatory mechanisms, plays a major role in the pathogenesis and progression of atherosclerosis, plaque rupture and vascular thrombotic propensity. The purpose of this study is to explore the relationship between retinal vascular calibers and biomarkers of oxidative stress and inflammation, in subjects free of cardiovascular pathology.Patients and Methods
Cross-sectional analysis from a community-dwelling cohort comprising 1224 individuals aged 60 years and over, without a history of coronary or peripheral artery disease or stroke. Retinal vascular caliber was measured from fundus photographs using semi-automated standardized imaging software. Oxidative stress was evaluated using plasma superoxide dismutase 2 and glutathione peroxidase (GPx-3) activities, and inflammatory state was assessed using plasma high sensitivity C-reactive protein (hsCRP) and orosomucoid.Results
In a multivariate model controlling for cardiovascular risk factors, larger retinal arteriolar caliber was independently related to higher level of GPx-3 activity (p = 0.003) whereas larger venular caliber was associated with higher levels of hsCRP (p = 0.0001) and orosomucoid (p = 0.01).Conclusion
In the present study, biomarkers of oxidative stress regulation and inflammation were independently associated with retinal vascular calibers. This suggests that an assessment of retinal vessels may offer early and non-invasive detection of subclinical vascular pathology. 相似文献8.
Sophia Pathai Helen A. Weiss Stephen D. Lawn Tunde Peto Leris M. D’Costa Colin Cook Tien Y. Wong Clare E. Gilbert 《PloS one》2012,7(12)
Objectives
HIV infection is associated with an increased risk of age-related morbidity mediated by immune dysfunction, atherosclerosis and inflammation. Changes in retinal vessel calibre may reflect cumulative structural damage arising from these mechanisms. The relationship of retinal vessel calibre with clinical and demographic characteristics was investigated in a population of HIV-infected individuals in South Africa.Methods
Case-control study of 491 adults ≥30 years, composed of 242 HIV-infected adults and 249 age- and gender-matched HIV-negative controls. Retinal vessel calibre was measured using computer-assisted techniques to determine mean arteriolar and venular diameters of each eye.Results
The median age was 40 years (IQR: 35–48 years). Among HIV-infected adults, 87.1% were receiving highly active antiretroviral therapy (HAART) (median duration, 58 months), their median CD4 count was 468 cells/µL, and 84.3% had undetectable plasma viral load. Unadjusted mean retinal arteriolar diameters were 163.67±17.69 µm in cases and 161.34±17.38 µm in controls (p = 0.15). Unadjusted mean venular diameters were 267.77±18.21 µm in cases and 270.81±18.98 µm in controls (p = 0.07). Age modified the effect of retinal arteriolar and venular diameters in relation to HIV status, with a tendency towards narrower retinal diameters in HIV cases but not in controls. Among cases, retinal arteriolar diameters narrowed with increasing duration of HAART, independently of age (167.83 µm <3 years of HAART vs. 158.89 µm >6 years, p-trend = 0.02), and with a HIV viral load >10,000 copies/mL while on HAART (p = 0.05). HIV-related venular changes were not detected.Conclusions
Narrowing of retinal arteriolar diameters is associated with HAART duration and viral load, and may reflect heightened inflammatory and pro-atherogenic states of the systemic vasculature. Measurement of retinal vascular calibre could be an innovative non-invasive method of estimating vascular risk in HIV-infected individuals. 相似文献9.
Hogne Soennesyn Dennis W. Nilsen Ketil Oppedal Ole Jacob Greve Mona K. Beyer Dag Aarsland 《PloS one》2012,7(12)
Background/Objectives
White matter hyperintensities (WMH) in magnetic resonance imaging (MRI) scans of the brain, and orthostatic hypotension (OH) are both common in older people. We tested the hypothesis that OH is associated with WMH.Design
Cross-sectional study.Setting
Secondary care outpatient clinics in geriatric medicine and old age psychiatry in western Norway.Participants
160 older patients with mild dementia, diagnosed according to standardised criteria.Measurements
OH was diagnosed according to the consensus definition, measuring blood pressure (BP) in the supine position and within 3 minutes in the standing position. MRI scans were performed according to a common protocol at three centres, and the volumes of WMH were quantified using an automated method (n = 82), followed by manual editing. WMH were also quantified using the visual Scheltens scale (n = 139). Multiple logistic regression analyses were applied, with highest vs. lowest WMH quartile as response.Results
There were no significant correlations between WMH volumes and systolic or diastolic orthostatic BP drops, and no significant correlations between Scheltens scores of WMH and systolic or diastolic BP drops. In the multivariate analyses, only APOEε4 status remained a significant predictor for WMH using the automated method (p = 0.037, OR 0.075 (0.007–0.851)), whereas only age remained a significant predictor for WMH scores (p = 0.019, OR 1.119 (1.018–1.230)).Conclusion
We found no association between OH and WMH load in a sample of older patients with mild dementia. 相似文献10.
Niko Braun Peter Fritz Christoph Ulmer Joerg Latus Martin Kimmel Dagmar Biegger German Ott Fabian Reimold Klaus-Peter Thon Juergen Dippon Stephan Segerer M. Dominik Alscher 《PloS one》2012,7(11)
Background
The two most relevant pathologies of long-term peritoneal dialysis (PD) are simple sclerosis and encapsulating peritoneal sclerosis (EPS). The histological differentiation of those two entities is difficult. The Aim of the study was to establish a method to standardize and facilitate the differentiation between simple sclerosis and EPSMethods
We investigated 58 peritoneal biopsies - 31 EPS patients and 27 PD patients. Two blinded investigators analyzed 20 histological characteristics in EPS and PD patients.Results
The following findings were significantly more common in EPS than in patients on PD without EPS: fibroblast like cells (FLC) (p<0.0001), mesothelial denudation (p<0.0001), decreased cellularity (p = 0.008), fibrin deposits (p<0.03), Fe deposits (p = 0.05), podoplanin vascular (p<0.0001), podoplanin avascular (p<0.0001). Using all predictor variables we trained the classification method Random Forest to categorize future cases. Podoplanin vascular and avascular were taken together (p<0.0001), FLC (p<0.0001), mesothelial denudation (p = 0.0005), calcification (p = 0.0026), acellular areas (p = 0.0094), and fibrin deposits (p = 0.0336) showed up as significantly important predictor variables. Estimated misclassification error rate when classifying new cases turned out to be 14%.Conclusion
The introduced statistical method allows discriminating between simple sclerosis and EPS. The misclassification error will likely improve with every new case added to the database. 相似文献11.
Ok M?lfrid Mangrud Rune Waalen Einar Gudlaugsson Ingvild Dalen Ilker Tasdemir Emiel A. M. Janssen Jan P. A. Baak 《PloS one》2014,9(1)
Background
European treatment guidelines of TaT1 urinary bladder urothelial carcinomas depend highly on stage and WHO1973-grade but grading reproducibility is wanting. The newer WHO2004 grading system is still debated and both systems are currently used.Aims
To compare reproducibility and prognostic value (of stage progression) of the WHO1973 and WHO2004.Methods
One hundred and ninety-three primary urothelial carcinomas were reviewed. Follow-up data were retrieved from the patient records. Kappa statistics and Harrell''s C-index were used.Results
Median follow-up was 75 months (range 1–127). 17 patients (9%) progressed, 82% of these within and 18% after 60 months. The distribution of WHO73-grades 1, 2 and 3 was 23%, 51% and 26%, interobserver agreement for each individual grade was 66% (kappa = 0.68), while for grades 1&2 versus 3 89% (kappa = 0.68). Intraobserver reproducibility was 68–63% for WHO73 and 88–89% for WHO73 as 1&2 vs.3. Progression free survival rates at 5 years were 95% (grade 1), 98% (grade 2) and 82% (grade 3) and 96% and 82% for grades 1&2 versus 3 (Hazard Ratio, HR, 5.4, p = 0.003). Using WHO2004, 62% were low grade and 38% high grade, inter-observer agreement 87% (kappa = 0.70), intraobserver reproducibility 93%, and progression free 5-year survival rates 97% and 85% (HR 6.6, p = 0.004). Positive and negative predictive values for stage progression within 5 years for the WHO73 (1&2 vs. 3) were 18% and 96%, and 15% and 97% for the WHO04. Using Harrell''s C-index, none of the grading systems was prognostically superior.Conclusion
None of the grading systems is prognostically stronger than the others. Most importantly, inter-observer reproducibility and sensitivities for stage progression of both systems are low and need improvement for optimal treatment. 相似文献12.
Purpose
To quantify short-term reproducibility (in fasting conditions) and postprandial changes after a meal in portal vein (PV) flow parameters measured with phase contrast (PC) imaging, liver diffusion parameters measured with multiple b value diffusion-weighted imaging (DWI) and liver stiffness (LS) measured with MR elastography (MRE) in healthy volunteers and patients with liver disease at 3.0 T.Materials and Methods
In this IRB–approved prospective study, 30 subjects (11 healthy volunteers and 19 liver disease patients; 23 males, 7 females; mean age 46.5 y) were enrolled. Imaging included 2D PC imaging, multiple b value DWI and MRE. Subjects were initially scanned twice in fasting state to assess short-term parameter reproducibility, and then scanned 20 min. after a liquid meal. PV flow/velocity, LS, liver true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were measured in fasting and postprandial conditions. Short-term reproducibility was assessed in fasting conditions by measuring coefficients of variation (CV) and Bland-Altman limits of agreement. Differences in MR metrics before and after caloric intake and between healthy volunteers and liver disease patients were assessed.Results
PV flow parameters, D, ADC and LS showed good to excellent short-term reproducibility in fasting state (CV <16%), while PF and D* showed acceptable and poor reproducibility (CV = 20.4% and 51.6%, respectively). PV flow parameters and LS were significantly higher (p<0.04) in postprandial state while liver diffusion parameters showed no significant change (p>0.2). LS was significantly higher in liver disease patients compared to healthy volunteers both in fasting and postprandial conditions (p<0.001). Changes in LS were significantly correlated with changes in PV flow (Spearman rho = 0.48, p = 0.013).Conclusions
Caloric intake had no/minimal/large impact on diffusion/stiffness/portal vein flow, respectively. PC MRI and MRE but not DWI should be performed in controlled fasting state. 相似文献13.
Pawel P. Wolkow Wladyslaw Kosiniak-Kamysz Grzegorz Osmenda Grzegorz Wilk Beata Bujak-Gizycka Adam Ignacak Mihir Kanitkar Malgorzata Walus-Miarka David G. Harrison Ryszard Korbut Maciej T. Malecki Tomasz J. Guzik 《PloS one》2014,9(11)
Background
The genetic background of atherosclerosis in type 2 diabetes mellitus (T2DM) is complex and poorly understood. Studying genetic components of intermediate phenotypes, such as endothelial dysfunction and oxidative stress, may aid in identifying novel genetic components for atherosclerosis in diabetic patients.Methods
Five polymorphisms forming two haplotype blocks within the GTP cyclohydrolase 1 gene, encoding a rate limiting enzyme in tetrahydrobiopterin synthesis, were studied in the context of flow and nitroglycerin mediated dilation (FMD and NMD), intima-media thickness (IMT), and plasma concentrations of von Willebrand factor (vWF) and malondialdehyde (MDA).Results
Rs841 was associated with FMD (p = 0.01), while polymorphisms Rs10483639, Rs841, Rs3783641 (which form a single haplotype) were associated with both MDA (p = 0.012, p = 0.0015 and p = 0.003, respectively) and vWF concentrations (p = 0.016, p = 0.03 and p = 0.045, respectively). In addition, polymorphism Rs8007267 was also associated with MDA (p = 0.006). Haplotype analysis confirmed the association of both haplotypes with studied variables.Conclusions
Genetic variation of the GCH1 gene is associated with endothelial dysfunction and oxidative stress in T2DM patients. 相似文献14.
Purpose
To determine the relationship between longitudinal in vivo measurements of retinal nerve fiber layer thickness (RNFLT) and retinal ganglion cell (RGC) density after unilateral optic nerve transection (ONT).Methods
Nineteen adult Brown-Norway rats were studied; N = 10 ONT plus RGC label, N = 3 ONT plus vehicle only (sans label), N = 6 sham ONT plus RGC label. RNFLT was measured by spectral domain optical coherence tomography (SD-OCT) at baseline then weekly for 1 month. RGCs were labeled by retrograde transport of fluorescently conjugated cholera toxin B (CTB) from the superior colliculus 48 hours prior to ONT or sham surgery. RGC density measurements were obtained by confocal scanning laser ophthalmoscopy (CSLO) at baseline and weekly for 1 month. RGC density and reactivity of microglia (anti-Iba1) and astrocytes (anti-GFAP) were determined from post mortem fluorescence microscopy of whole-mount retinae.Results
RNFLT decreased after ONT by 17% (p<0.05), 30% (p<0.0001) and 36% (p<0.0001) at weeks 2, 3 and 4. RGC density decreased after ONT by 18%, 69%, 85% and 92% at weeks 1, 2, 3 and 4 (p<0.0001 each). RGC density measured in vivo at week 4 and post mortem by microscopy were strongly correlated (R = 0.91, p<0.0001). In vivo measures of RNFLT and RGC density were strongly correlated (R = 0.81, p<0.0001). In ONT- CTB labeled fellow eyes, RNFLT increased by 18%, 52% and 36% at weeks 2, 3 and 4 (p<0.0001), but did not change in fellow ONT-eyes sans CTB. Microgliosis was evident in the RNFL of the ONT-CTB fellow eyes, exceeding that observed in other fellow eyes.Conclusions
In vivo measurements of RNFLT and RGC density are strongly correlated and can be used to monitor longitudinal changes after optic nerve injury. The strong fellow eye effect observed in eyes contralateral to ONT, only in the presence of CTB label, consisted of a dramatic increase in RNFLT associated with retinal microgliosis. 相似文献15.
16.
Wen Liang Aswin L. Menke Ann Driessen Ger H. Koek Jan H. Lindeman Reinout Stoop Louis M. Havekes Robert Kleemann Anita M. van den Hoek 《PloS one》2014,9(12)
Background and aims
The recently developed histological scoring system for non-alcoholic fatty liver disease (NAFLD) by the NASH Clinical Research Network (NASH-CRN) has been widely used in clinical settings, but is increasingly employed in preclinical research as well. However, it has not been systematically analyzed whether the human scoring system can directly be converted to preclinical rodent models. To analyze this, we systematically compared human NAFLD liver pathology, using human liver biopsies, with liver pathology of several NAFLD mouse models. Based upon the features pertaining to mouse NAFLD, we aimed at establishing a modified generic scoring system that is applicable to broad spectrum of rodent models.Methods
The histopathology of NAFLD was analyzed in several different mouse models of NAFLD to define generic criteria for histological assessment (preclinical scoring system). For validation of this scoring system, 36 slides of mouse livers, covering the whole spectrum of NAFLD, were blindly analyzed by ten observers. Additionally, the livers were blindly scored by one observer during two separate assessments longer than 3 months apart.Results
The criteria macrovesicular steatosis, microvesicular steatosis, hepatocellular hypertrophy, inflammation and fibrosis were generally applicable to rodent NAFLD. The inter-observer reproducibility (evaluated using the Intraclass Correlation Coefficient) between the ten observers was high for the analysis of macrovesicular steatosis and microvesicular steatosis (ICC = 0.784 and 0.776, all p<0.001, respectively) and moderate for the analysis of hypertrophy and inflammation (ICC = 0.685 and 0.650, all p<0.001, respectively). The intra-observer reproducibility between the different observations of one observer was high for the analysis of macrovesicular steatosis, microvesicular steatosis and hypertrophy (ICC = 0.871, 0.871 and 0.896, all p<0.001, respectively) and very high for the analysis of inflammation (ICC = 0.931, p<0.001).Conclusions
We established a simple NAFLD scoring system with high reproducibility that is applicable for different rodent models and for all stages of NAFLD etiology. 相似文献17.
Purpose
To present a method for image segmentation and generation of enface thickness maps and reflectance images of retinal layers in healthy and diabetic retinopathy (DR) subjects.Methods
High density spectral domain optical coherence tomography (SDOCT) images were acquired in 10 healthy and 4 DR subjects. Customized image analysis software identified 5 retinal cell layer interfaces and generated thickness maps and reflectance images of the total retina (TR), inner retina (IR), outer retina (OR), and the inner segment ellipsoid (ISe) band. Thickness maps in DR subjects were compared to those of healthy subjects by generating deviation maps which displayed retinal locations with thickness below, within, and above the normal 95% confidence interval.Results
In healthy subjects, TR and IR thickness maps displayed the foveal depression and increased thickness in the parafoveal region. OR and ISe thickness maps showed increased thickness at the fovea, consistent with normal retinal anatomy. In DR subjects, thickening and thinning in localized regions were demonstrated on TR, IR, OR, and ISe thickness maps, corresponding to retinal edema and atrophy, respectively. TR and OR reflectance images showed reduced reflectivity in regions of increased thickness. Hard exudates appeared as hyper-reflective spots in IR reflectance images and casted shadows on the deeper OR and ISe reflectance images. The ISe reflectance image clearly showed the presence of focal laser scars.Conclusions
Enface thickness mapping and reflectance imaging of retinal layers is a potentially useful method for quantifying the spatial and axial extent of pathologies due to DR. 相似文献18.
Background
Many scoring systems exist for clock drawing task variants. However, none of them are reliable in evaluating longitudinal changes of cognitive function. The purpose of this study is to create a simple yet optimal scoring procedure to evaluate cognitive decline using a clinic-based sample.Methods
Clock-drawings from 121 participants (76 individuals with no dementia and later did not develop dementia after a mean 41.2-month follow-up, 45 individuals with no dementia became demented after a mean 42.3-month follow-up) were analyzed using t-test to determine a new and simplified CDT scoring system. The new scoring method was then compared with other commonly used systems.Results
In the converters, there were only 7 items that are significantly different between the initial visits and the second visits. We propose a new scoring system that includes the seven critical items: numbers are equally spaced (12–3–6–9) (p = 0.031), the other eight numbers are marked (p = 0.022), numbers are clockwise (p = 0.002), all numbers are correct (p = 0.030), distance between numbers is constant (p = 0.016), clock has two hands (p = 0.000), arrows are drawn (p = 0.003). Compared with other traditionally used scoring methods, this based change clock drawing test (BCCDT) has one of the most balanced sensitivities/specificities with a clinic-based sample.Conclusions
The new CDT scoring system provides further evidence in support of a simple and reliable clock-drawing scoring system in follow-up studies to evaluate cognitive decline, which can be used in assessing the efficacy of medicine. 相似文献19.
20.