1.
A bioanalytical method for the determination of piperaquine in 100 microL blood applied onto sampling paper, by solid-phase extraction and liquid chromatography, has been developed and validated. Blood spots were cut into small pieces prior to addition of 0.3M perchloric acid, acetonitrile and phosphate buffer containing an internal standard. The liquid phase was loaded onto a mixed phase cation-exchange (MPC) solid-phase extraction column. Piperaquine and the internal standard were analysed by liquid chromatography and separated on a Chromolith Performance (100 mm x 4.6 mm) column with acetonitrile:phosphate buffer pH 2.5, I = 0.1 (8:92, v/v) at the flow of 3.5 mL/min. The UV detection was performed at 345 nm. The intra-assay precision was 12.0% at 0.150 microM, 7.3% at 1.25 microM and 7.3% at 2.25 microM. The inter-assay precision was 1.8% at 0.150 microM, 5.2% at 1.25 microM and 2.8% at 2.25 microM. The lower limit of quantification (LLOQ) was determined to 0.050 microM where the precision was 14.7%.  相似文献   

2.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

3.
A nonradioactive, sensitive, rapid, and specific method for the determination of methionine adenosyltransferase activity has been established. In this method, the methyl group of S-adenosyl-L-methionine was enzymatically transferred to esculetin with the aid of catechol-O-methyltransferase and then the resulting scopoletin was extracted with n-hexane:ethyl acetate (7:3, v/v) and measured by high-performance liquid chromatography with Si 60 column and fluorometric detection with excitation and emission wavelengths at 347 and 415 nm, respectively. The detection limit for scopoletin was about 100 fmol. Using this method to determine MAT activity in HL-60 cells required only about 2.5 microg of protein and the incubation time needed for enzymatic reaction is less than 30 min. The HPLC analysis procedure took only 5 min per sample. The kinetic study showed that MAT in HL-60 cells exhibited negative cooperativity with a Hill coefficient of 0.5. The values of K(m) and V(max) were 6.1+/-0.3 microM and 135.4+/-1.5 nmol AdoMet formed/mg protein/h, respectively.  相似文献   

4.
The biodistribution of 11C-labeled 4-(3-bromoanilino)-6,7-dimethoxyquinazoline, an inhibitor of the epidermal growth factor (EGF) receptor tyrosine kinase, has been evaluated in vivo in rats using positron emission tomography (PET). Time-activity data obtained after i.v. administration in one rat revealed that the radiotracer rapidly cleared from plasma with subsequent uptake in major organs of the body (brain, heart, liver, gastrointestinal tract and bladder). Uptake in proliferating tissue in rats with human neuroblastoma xenografts indicate that [O-11C-methyl]PD153035 shows promise as a new agent for in vivo imaging of tumors with PET.  相似文献   

5.
A simple and sensitive high-performance liquid chromatographic (HPLC) method using ultraviolet detection was developed for the determination of testosterone in human plasma. Testosterone and the internal standard, griseofulvin, were extracted from 0.50 ml plasma sample using a mixture of dichloromethane-2,2,4-trimethylpentane (3:2, v/v). The mobile phase, consisted of 0.02 M sodium dihydrogenphosphate-acetonitrile-methanol (51:47:2, v/v) adjusted to pH 3.1 and delivered to a C(18) analytical column (150 x 4.6 mm I.D., 4 microm particles) at a flow-rate of 1 ml/min while the detection wavelength was set at 240 nm with a sensitivity range of 0.005 a.u.f.s. The method has a quantification limit of 1.6 ng/ml. Recoveries of testosterone were all greater than 92% over the linear concentration range of 1.6-400 ng/ml while that of griseofulvin was approximately 95%. The within- and between-day RSD values were all less than 8% while the accuracy values ranged from 96.0 to 106.0% over the concentration range studied. The method was applied to the analysis of early morning plasma testosterone levels of 12 healthy human male volunteers. The levels were found to range from 3.1 to 8.4 ng/ml, within the normal range reported in the literature.  相似文献   

6.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

7.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

8.
A highly sensitive and specific LC-MS/MS method has been developed for simultaneous estimation of itraconazole (ITZ) and hydroxyitraconazole (OH-ITZ) with 500 microL of human plasma using fluconazole as an internal standard (IS). The API-4000 LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Solid phase extraction process was used to extract ITZ, OH-ITZ and IS from human plasma. The total run time was 3.0 min and the elution of ITZ, OH-ITZ and IS occurred at 2.08 min, 1.85 min and 1.29 min, respectively; this was achieved with a mobile phase consisting of 0.2% (v/v) ammonia solution:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a HyPurity C(18) (50 mm x 4.6 mm, 5 microm) column. The developed method was validated in human plasma with a lower limit of quantitation of 0.50 ng/mL for both ITZ and OH-ITZ. A linear response function was established for the range of concentrations 0.5-263 ng/mL (r>0.998) for both ITZ and OH-ITZ. The intra- and inter-day precision values for ITZ and OH-ITZ met the acceptance as per FDA guidelines. ITZ and OH-ITZ were stable in the battery of stability studies, viz., bench-top, auto-sampler, dry extract and freeze/thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans.  相似文献   

9.
A sensitive and selective LC-MS-MS method for the determination of DPC 423 (I), an antithrombotic agent, is described. This method used a solid-phase extraction from 0.1 ml plasma with an Isolute C(2) cartridge. HPLC separation was carried out on a YMC ODS-AQ C(18) column (50x2 mm) at a flow-rate of 300 microliter/min with an analysis time of 5 min. Compounds were eluted using a mobile phase of H(2)O/CH(3)CN/HCOOH: 66:34:0.1 (v/v/v), pH 4.0. A structural analogue of I was used as the internal standard to account for variations in recovery and instrument response. Mass spectrometric detection was carried out with a PE Sciex API III(+) triple quadrupole mass spectrometer equipped with a Turbo IonSpray source as the LC-MS interface. Good intra-day and inter-day assay precision (<10% CV) and accuracy (<10% difference) were observed over a concentration range of 0.005-2.5 microM in plasma. The extraction recoveries were approximately 90% and the method was found to be linear for the assay (r(2)>0.999). The method has been successfully applied to discovery and preclinical pharmacokinetic studies, including a dose range-finding study and toxicokinetic exposure studies in rat and dog.  相似文献   

10.
A sensitive assay for the determination of SYUIQ-5, a novel telomerase inhibitor and anti-tumor drug, in rat liver microsomes was developed by using high-performance liquid chromatography with ultraviolet detection. SYUIQ-5 was incubated in vitro with liver microsomes from rats pre-treated with control vehicle, beta-naphthofIavone, phenobarbital, 20% ethanol or dexamethasone. The analytes were extracted with diethyl ether and separated a C(18) 5-microm analytical column. Elution was conducted with 30 mM dipotassium hydrogen phosphate (pH 8.0)-methanol-triethylamine (30:70:0.05, v/v/v) at a flow-rate of 1.0 ml/min and the detection of UV absorbance was conducted at 278 nm. Intra-day and inter-day precision and accuracy of the method were within 10%. The mean analytical recoveries of SYUIQ-5 ranged from 78.8 to 95.3%. The linearity of the calibration curve was in the range of 1.0-80.0 microM. The lower limit of quantification (LOQ) was 1.0 microM. Kinetic analysis showed that beta-naphthofIavone and dexamethasone significantly induced SYUIQ-5 metabolism, suggesting that cytochrome P450 1A and 3A are the major contributor to SYUIQ-5 metabolism in rat liver microsomes.  相似文献   

11.
A miniaturized temperature-programmed packed capillary liquid chromatographic method with on-column large volume injection and UV detection for the simultaneous determination of the three selective serotonin reuptake inhibitors citalopram, fluoxetine, paroxetine and their metabolites in plasma is presented. An established reversed-phase C8 solid-phase extraction method was employed, and the separation was carried out on a 3.5-microm Kromasil C18 0.32x300 mm column with temperature-programming from 35 (3 min) to 100 degrees C (10 min) at 1.3 degrees C/min. The mobile phase consisted of acetonitrile-45 mM ammonium formate (pH 4.00) (25:75, v/v). The non-eluting sample focusing solvent composition acetonitrile-45 mM ammonium formate (pH 4.00) (3:97, v/v) allowed injection of 10 microl or more of the plasma extracts. The method was validated for the concentration range 0.05-5.0 microM, and the calibration curves were linear with coefficients of correlation >0.993. The limits of quantification for the antidepressants and their metabolites ranged from 0.05 to 0.26 microM. The within and between assay precision of relative peak height were in the range 2-22 and 2-15% relative standard deviation, respectively. The within and between assay recoveries were in the 61-99 and 54-92% range for the antidepressants, respectively, and between 52-102 and 51-102% for the metabolites.  相似文献   

12.
A simple method for determining the concentration of astilbin, a flavanone, in rabbit plasma has been developed. After liquid-liquid extraction, the flavanone was detected by HPLC on a 4.6-microm octadecylsilica column (Nova-Pak C-18) at 291 nm. Linear calibration graphs for astilbin were constructed from 0.44 to 22.17 microM. The limit of quantitation was 0.44 microM in plasma. The method has been applied to pharmacokinetic studies after a single i.v. and an oral administration of the compound to rabbits.  相似文献   

13.
A sensitive, rapid, selective and reproducible method has been developed to measure plasma levels of sulfadoxine, 4-Amino-N-(5, 6-dimethoxy-4-pyrimidinyl) benzensulfonamide; in healthy, human volunteers using packed-column supercritical fluid chromatography. Omeprazole, 5-methoxy-2-[[(4-methoxy-3, 5-di-methyl-2-pyridinyl)methyl]sulfinyl]-1H-benzimidazole; was used as the internal standard (i.s.) at 15.0 μg/ml. The drug and the i.s. were extracted from plasma using dichloromethane. Separation of sulfadoxine and i.s. was done on a Nucleosil (250×4.6 mm) 10 μm, RP-C18 column with 7.4% (v/v) methanol-modified supercritical fluid carbon dioxide (2.5 ml/min) as the mobile phase. The column temperature was 40°C and the outlet pressure was set at 8.83 MPa. The detection was done using a UV–Vis detector set at 265 nm. The limit of quantification was 0.50 μg/ml using 1 ml plasma specimen. The mean extraction recovery of the drug from plasma was found to be 94.9%. The SFC method was directly compared to a published HPLC/UV method. With respect to speed and use of organic solvents SFC was found to be superior; while in all other aspects the results were similar to the published technique. The method has been successfully used to estimate the sulfadoxine levels in healthy human volunteers from 0 to 240 h following an oral dose of 500 mg of sulfadoxine in combination with 25 mg of pyrimethamine.  相似文献   

14.
A reversed-phase high-performance liquid chromatographic method for oxazepam in human urine samples has been developed. The sample preparation consists of an enzymatic hydrolysis with β-glucuronidase, followed by a solid-phase extraction process using Bond-Elut C2 cartridges. The mobile phase used was a methanol—water (60:40, v/v) mixture at a flow-rate of 0.50 ml/min. The column was a 3.5 cm × 4.6 mm I.D. C18 reversed-phase column. The detection system was based on a fluorescence post-column derivatization of oxazepam in mixtures of methanol and acetic acid. A linear range from 0.01 to 1 μg/ml of urine and a limit of detection of 4 ng/ml of urine were attained. Within-day recoveries and reproducibilities from urine samples spiked with 0.2 and 0.02 μg/ml oxazepam were 97.9 and 95.0 and 2.1 and 9.4%, respectively.  相似文献   

15.
16.
17.
An isocratic HPLC charged aerosol detector (CAD) method was developed, validated, and applied for the determination of individual bile acids in human gastric and duodenal aspirates. The method requires a low volume of aspirates (50-100 microl) and minimal sample pretreatment. A Hypersil BDS RP-C(18) column (250 x 4.6 mm, 5 microm particle size) was equilibrated with a mobile phase composed of methanol-[ammoniun formate 20 mM, formic acid 0.5%, triethylamine 0.2% (pH 3)] 67:33 v/v. Its flow rate was 1 ml/min. The elution times for taurocholate, glycocholate, taurochenodeoxycholate, ursodeoxycholate, glycochenodeoxycholate, cholate, and glycodeoxycholate were approximately 9.9, 16.2, 18.2, 21.3, 31.6, 34.5, and 38.5 min, respectively. Calibration curves in the mobile phase were constructed in the concentration range of 0.5-500 microM. Limits of detection and quantification were in the range of 0.07-0.60 microM and 0.20-1.80 microM, respectively. This method was applied first, in gastric aspirates collected in the fasted state, in which bile acid presence is minimal and, second, in duodenal aspirates collected in the fed state, in which a large number of potentially interfering compounds exists. Intra-day relative standard deviation in fasted gastric aspirates and in fed duodenal aspirates was less than 2.2% and 6.0%, respectively.  相似文献   

18.
This study describes successful method development and separation of two stereo isomers of 2-[4-(methylsulfonyl)phenyl]-3-(3(R)-oxocyclopentyl)propanoic acid by reverse phase high-performance liquid chromatography. Baseline resolution was achieved on a J'sphere-ODS-H80 (150 mm × 4.6 mm, 4 μm) column using mobile phase consisting of 0.05% triflouroacetic acid in water-acetonitrile (85:15, v/v) at a flow rate of 1.0 ml/min. The detection was carried out at 228 nm. The title compound, in turn, can be obtained by C-alkylation of methyl 2-[4-(methylthio)phenyl]acetate with 2(S)-iodomethyl-8,8-dimethyl-6,10-dioxaspiro[4.5]decane followed by consecutive hydrolysis and oxidation. The partially validated analytical method (system suitability, peak homogeneity, linearity, precision, robustness, and solution stability) has limit of detection and limit of quantification, 0.15 and 0.50 μg/ml respectively. Alternatively, the new method is being routinely utilized to monitor epimerization of α-carbon of the propanoic acid in the title compound by crystallization-induced dynamic resolution.  相似文献   

19.
A fast, simple and sensitive column-switching high-performance liquid chromatography (HPLC)-fluorescence detection method was developed on a monolithic silica column for the determination of N(G),N(G)-dimethyl-L-arginine (ADMA), which is an endogenous nitric oxide synthase inhibitor. After fluorescence derivatization of plasma samples or homogenized tissues with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), the samples were injected into the HPLC system. The NBD-derivatized ADMA was trapped on a cation-exchange column and separated within 15 min on a monolithic silica column. The detection limit for ADMA was 36 nM (250 fmol per injection) when the signal-to-noise ratio was 3. A good linearity for calibration curve for ADMA was observed within the range of 140 nM (1.0 pmol per injection) - 140 microM (1.0 nmol per injection) using N(G)-monomethyl-L-arginine (L-NMMA) as an internal standard. The proposed method was used for the quantitative determination of ADMA in rat plasma. The concentrations of ADMA in rat plasma were 0.82+/-0.05 microM (n=4). Furthermore, the method developed was applied to determine dimethylarginine dimethylaminohydrolase (DDAH) enzyme activity in rat kidney, which was assayed by measuring the amount of ADMA metabolized by the enzyme.  相似文献   

20.
A HPLC method with UV detection (210 nm) was developed and validated for the quantification of atomoxetine, a new medication for the treatment of attention deficit/hyperactivity disorder, in human plasma. Following a two-step liquid-liquid extraction with diethyl ether, the analyte and internal standard (maprotiline) were separated using an isocratic mobile phase of acetonitrile/phosphate buffer (39/61, v/v, pH 6.6) on a reverse phase Inertsil C(18) column. Linearity was verified over the range of 3.12-200 ng/mL atomoxetine in plasma. The lowest limit of detection is 2.5 ng/mL (S/N=10). This HPLC method was validated with within- and between-batch precisions of 4.9-14.4% and 4.7-13.1%, respectively. The within- and between-batch biases were -1.9 to 1.4% and 0.1-13.8%, respectively. Commonly used psychotropic drugs and frequently coadministered drugs did not interfere with the drug and internal standard. This method is simple, economical and specific, and has been used successfully in a pharmacokinetic study of atomoxetine.  相似文献   