首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 677 毫秒
1.
A simple NaOH treatment method was developed for fabricating nonwoven fibrous matrices of polyethylene terephthalate (PET) with predictable porosity, pore size, and fiber diameter. Matrices with various porosities (90–97%), fiber diameters (13.5–25 μm), and pore sizes (54–65 μm) were prepared by treating with 1N NaOH at 70 °C for up to 120 h, resulting in up to 70% hydrolysis of the PET polymer. The hydrolysis of PET polymer by NaOH was found to follow a second-order kinetics with respect to the fiber surface area. Accordingly, mathematical models were developed to predict matrix porosity, fiber diameter, and apparent pore size of the PET matrices. The exponential decay coefficient of PET polymer was found to be 0.0147 h−1. The matrices were used to study the effects of pore size and fiber diameter on cell seeding and proliferation. The seeding study demonstrated that cell adhesion on PET fibers can be enhanced, largely due to the increased surface roughness of the PET fibers. Decreasing the fiber diameter increases the surface curvature of the fibers and decreases available surface area for cell attachment, which, however, only resulted in a small decrease in the cell growth rate.  相似文献   

2.
Uniform, large surface area substrates for surface-enhanced Raman spectroscopy (SERS) are fabricated by oblique angle deposition. The SERS-active substrates are patterned by a polymer-molding technique to provide a uniform array for high throughput biosensing and multiplexing. Using a conventional SERS-active molecule, 1,2-di(4-pyridyl)ethylene (BPE) ≥98%, we show that this device provides a uniform Raman signal enhancement from well to well with a detection limit of at least 10−8 M of the BPE solution or 10−18 mol of BPE. The SERS intensity is also demonstrated to vary logarithmically with the log of BPE concentration and the apparent sensitivity of the patterned substrate is compared to previous reports from our group on non-patterned substrates. Avian influenza is analyzed to demonstrate the utility of SERS multiwell patterned substrates for biosensing. The spectra acquired from patterned substrates show better reproducibility and less variation compared to the unpatterned substrates according to multivariate analysis. Our results highlight potential advantages of the patterned substrate.  相似文献   

3.
Surface imprinting is an effective approach to improve the template transfer efficiency in applications of molecularly imprinted polymers as biosensors and separation materials. In this paper, we tried to fabricate a surface imprinted hydrogel over silica microspheres for selective recognition of bovine serum albumin by covalent immobilization of a water-soluble UV sensitive initiator onto the surface of silica beads. The polymerization was initiated by UV radiation with N-[3-(dimethylamino)propyl]methacrylamide and N-isopropylacrylamide as the functional monomer and assistant monomer, respectively, and a thin coat of stimuli-responsive hydrogel yielded over the silica gels. The surface imprinted hydrogels exhibited specific affinity toward the template protein with an association constant (Ka) of 2.2 × 105 L mol−1 and a maximum binding capacity (Qmax) of 27.3 mg g−1 in Tris–HCl buffer (pH 7.0). The rebinding and desorption kinetics of the surface imprinted hydrogels were determined and proven to be extremely fast (about 1 min compared to 3 h for the previously prepared bulk imprinted hydrogel). Besides, the hydrogel-silica core-shell particles inherit both the stimuli-responsive property of the hydrogel and the good mechanical strength of the silica beads based on the on-line evaluation with high-performance liquid chromatography. The above comprehensive merits of the obtained surface imprinted hydrogel suggest the presented approach an attractive and broadly applicable way of developing biosensors and high-performance protein separation materials.  相似文献   

4.
A high-performance surface plasmon resonance (SPR) sensor based on a novel approach to spectroscopy of surface plasmons is reported. This approach employs a special diffraction grating structure (referred to as surface plasmon resonance coupler and disperser, SPRCD) which simultaneously couples light into a surface plasmon and disperses the diffracted light for spectral readout of SPR signal. The developed SPRCD sensor consists of a miniature cartridge integrating the diffraction grating and microfluidics and a compact optical system which simultaneously acquires data from four independent sensing channels in the cartridge. It is demonstrated that the SPRCD sensor is able to measure bulk refractive index changes as small as 3 × 10−7 RIU (refractive index units) and to detect short oligonucleotides in concentrations down to 200 pM.  相似文献   

5.
A novel glucose biosensor was developed, based on the immobilization of glucose oxidase (GOD) with cross-linking in the matrix of bovine serum albumin (BSA) on a Pt electrode, which was modified with gold nanoparticles decorated Pb nanowires (GNPs-Pb NWs). Pb nanowires (Pb NWs) were synthesized by an l-cysteine-assisted self-assembly route, and then gold nanoparticles (GNPs) were attached onto the nanowire surface through –SH–Au specific interaction. The morphological characterization of GNPs-Pb NWs was examined by transmission electron microscopy (TEM). Cyclic voltammetry and chronoamperometry were used to study and to optimize the electrochemical performance of the resulting biosensor. The synergistic effect of Pb NWs and GNPs made the biosensor exhibit excellent electrocatalytic activity and good response performance to glucose. The effects of pH and applied potential on the amperometric response of the biosensor have been systemically studied. In pH 7.0, the biosensor showed the sensitivity of 135.5 μA mM−1 cm−2, the detection limit of 2 μM (S/N = 3), and the response time <5 s with a linear range of 5–2200 μM. Furthermore, the biosensor exhibits good reproducibility, long-term stability and relative good anti-interference.  相似文献   

6.
An attractive biocomposite based on polycrystalline bismuth oxide (BiOx) film and polyphenol oxidase (PPO) was proposed for the construction of a mediator-free amperometric biosensor for phenolic compounds in environmental water samples. The phenolic biosensor could be easily achieved by casting the biocomposite on the surface of glassy carbon electrode (GCE) via the cross-linking step by glutaraldehyde. The laboratory-prepared bismuth oxide semiconductor was polymorphism. Its hydrophilicity provided a favorable microenvironment for retaining the biological activity of the immobilized protein. The parameters of the fabrication process and the various experimental variables for the enzyme electrode were optimized. The proposed PPO/BiOx biosensor provided a linear response to catechol over a concentration range of 4 × 10−9 M to 1.5 × 10−5 M with a dramatically developed sensitivity of 11.3 A M−1 cm−2 and a detection limit of 1 × 10−9 M based on S/N = 3. In addition, the PPO/BiOx biocomposite was characterized by scanning electron microscope (SEM), Fourier transform infrared spectra (FTIR) and rotating disk electrode voltammetry.  相似文献   

7.
The submerged aquatic plant Myriophyllum spicatum L. (Eurasian water milfoil) has been suggested as an efficient plant species for the treatment of metal-contaminated industrial wastewater. The process of metal removal by plants involves a combination of rapid sorption on the surface and slow accumulation and translocation in the biomass. This study focussed on the sorption/desorption characteristics of the surface of M. spicatum for Co, Cu, Ni and Zn. Batch sorption tests with mixed metal solutions covering a range of 0, 1, 5, 10, 50 and 100 mg l−1 of each metal, were performed. For Co, Ni and Zn, the sorption process was well described by the Langmuir model, whereas sorption of Cu was better described by the Freundlich model. The biomass showed the highest affinity for Cu and Zn. Langmuir sorption maxima of Co, Ni and Zn were 2.3, 3.0 and 6.8 mg g−1 DM, respectively. At the highest initial concentration of 100 mg l−1, a maximum of 29 mg g−1 DM of Cu was sorbed onto the surface of the biomass. Desorption by 0.1 M HCl did not fully recover the metals sorbed onto the surface and there was evidence of leaching from within the biomass. Recovery of heavy metals and regeneration of the biomass by washing with 0.1 M HCl was therefore not suggested as a viable strategy.  相似文献   

8.
Du  Bobo  Yang  Yuan  Zhang  Yang  Yang  Dexing 《Plasmonics (Norwell, Mass.)》2019,14(2):457-463

In this article, a surface plasmon resonance (SPR) biosensor based on D-typed optical fiber coated by Al2O3/Ag/Al2O3 film is investigated numerically. Resonance in near infrared with an optimized architecture is achieved. Refractive index sensitivity of 6558 nm/RIU (refractive index unit) and detection limit of 1.5 × 10−6 RIU, corresponding to 0.4357 nm/μM and detection limit of 23 nM in BSA (bovine serum albumin) concentration sensing, are obtained. The analysis of the performance of the sensor in gaseous sensing indicates that this proposed SPR sensor is much suitable for label-free biosensing in aqueous media.

  相似文献   

9.
The adsorption of dissolved domoic acid (DA) and its geometrical isomers was assessed in aqueous solutions containing various types of particles. In one series of experiments carried out in coastal seawater, detectable net adsorption of 100 nM DA occurred only onto natural seawater particles (unfiltered seawater) and 0.5 g L−1 chromatographic silica (18%) in 0.2 μm-filtered seawater. Some net adsorption (<5%) also occurred in the 0.5 g L−1 suspension of estuarine sediment and 0.5 g L−1 solution of humic acid in filtered seawater. No losses were seen in 0.5 g L−1 suspensions of illite, kaolinite, montmorillonite, and silica sand. Biological degradation accounted for small losses (8–10%) in filtered seawater without particles. A second series of experiments using organic-free, <5 μm fractions of kaolinite and montmorillonite in deionized water (DIW) demonstrated that 70% of DA adsorbed onto kaolinite, but only 5% onto montmorillonite. Geometrical isomers of DA (iso-DA D, E, and F) showed negligible adsorption (0–8%) onto a variety of particles in filtered seawater, suggesting that major ions in seawater neutralize electrostatic attractions between particles and DA isomers. These results suggest that DA and its isomers are relatively hydrophilic and not particle reactive. Our data suggest that photochemical and biological degradation of dissolved DA and its isomers appears to occur in bulk surface seawater and its transport to bottom sediments must be mainly biologically driven.  相似文献   

10.
Electrochemical oxidation of serotonin (SN) onto zinc oxide (ZnO)-coated glassy carbon electrode (GCE) results in the generation of redox mediators (RMs) that are strongly adsorbed on electrode surface. The electrochemical properties of zinc oxide-electrogenerated redox mediator (ZnO/RM) (inorganic/organic) hybrid film-coated electrode has been studied using cyclic voltammetry (CV). The scanning electron microscope (SEM), atomic force microscope (AFM), and electrochemical techniques proved the immobilization of ZnO/RM core/shell microparticles on the electrode surface. The GCE modified with ZnO/RM hybrid film showed two reversible redox peaks in acidic solution, and the redox peaks were found to be pH dependent with slopes of −62 and −60 mV/pH, which are very close to the Nernst behavior. The GCE/ZnO/RM-modified electrode exhibited excellent electrocatalytic activity toward the oxidations of ascorbic acid (AA), dopamine (DA), and uric acid (UA) in 0.1 M phosphate buffer solution (PBS, pH 7.0). Indeed, ZnO/RM-coated GCE separated the anodic oxidation waves of DA, AA, and UA with well-defined peak separations in their mixture solution. Consequently, the GCE/ZnO/RMs were used for simultaneous detection of DA, AA, and UA in their mixture solution. Using CV, calibration curves for DA, AA, and UA were obtained over the range of 6.0 × 10−6 to 9.6 × 10−4 M, 1.5 × 10−5 to 2.4 × 10−4 M, and 5.0 × 10−5 to 8 × 10−4 M with correlation coefficients of 0.992, 0.991, and 0.989, respectively. Moreover, ZnO/RM-modified GCE had good stability and antifouling properties.  相似文献   

11.
A novel graphitized ordered macroporous carbon (GMC, pore size 380 nm) with hierarchical mesopores (2–30 nm) and high graphitization degree was prepared by nickel-catalyzed graphitization of polystyrene arrays. The obtained GMC possessed high specific surface area, large pore volume, and good electrical conductivity, which was explored for the enzyme entrapment and biosensor fabrication by a facile method. With advantages of novel nanostructure and good electrical conductivity, direct electrochemistry of hemoglobin (a model protein) was observed on the GMC-based biocomposite with a formal potential of −0.36 V (vs. Ag/AgCl) and an apparent heterogeneous electron transfer rate constant (ks) of 1.2 s−1 in pH 7.0 buffer. Comparative studies revealed that GMC offered significant advantages over carbon nanotubes (CNTs) in facilitating direct electron transfer of entrapped Hb. The fabricated biosensor exhibited good sensitivity (101.6 mA cm−2 M−1) and reproducibility, wide linear range (1–267 μM), low detection limit (0.1 μM), and good long-term stability for H2O2 detection. GMC proved to be a promising matrix for enzyme entrapment and biosensor fabrication, and may find wide potential applications in biomedical detection and environmental analyses.  相似文献   

12.
The present paper reports the graft copolymerization of N-vinylformamide onto sodium carboxymethylcellulose by free radical polymerization using potassium peroxymonosulphate/thiourea redox system in an inert atmosphere. The reaction conditions for maximum grafting have been optimized by varying the reaction variables, including the concentration of N-vinylformamide (12.0 × 10−2–28.0 × 10−2 mol dm−3), potassium peroxymonosulphate (4.0 × 10−3–12.0 × 10−3 mol dm−3), thiourea (1.2 × 10−3–4.4 × 10−3 mol dm−3), sulphuric acid (2.0 × 10−3–10.0 × 10−3 mol dm−3), sodium carboxymethylcellulose (0.2–1.8 g dm−3) along with time duration (60–180 min) and temperature (25–45° C). Water swelling capacity, metal ion sorption and flocculation studies of synthesized graft copolymer have been performed with respect to the parent polymer. The graft copolymer has been characterized by FTIR spectroscopy and thermogravimetric analysis.  相似文献   

13.
A novel direct readout colorimetric optical glucose sensor strip was constructed based on a three-layer film, including a green-emitted CdTe/CdS quantum dots (QDs) layer as a stable color background, a red-fluorescent platinum-porphyrin oxygen-sensing layer and a glucose oxidase layer. The sensor achieved high resolution (up to 0.2 mmol L−1) glucose determination with a detection range from 0 to 3.0 mmol L−1. A “glucose ruler” which acts as a glucose standard colorimetric card was obtained. Glucose concentration could easily be directly readout using the “glucose ruler”, which made the glucose determination rapid, convenient and easy. The effects of pH, salinity and temperature were systematically investigated. The prepared sensor was finally applied for glucose sample analysis, compared with the “glucose ruler”, accurate results could be directly readout.  相似文献   

14.
N-Acyl homoserine lactone (AHL) is a widely conserved quorum sensing (QS) signal of Gram-negative bacteria and has received attention in fighting against human diseases and environmental pollution. However, a method for quantifying AHL is lacking although it is urgently required for diagnosis and bioprocess manipulation. This work screened out an aromatics degrader Pseudomonas aeruginosa for biosensing system development, which produced a blue–green pigment regulated by the RhlI–RhlR QS system. By taking advantage of the recognition of N-butyryl homoserine lactone (BHL, the signal molecule of RhlI–RhlR QS system and an AHL) by the product of rhlR, a new whole-cell biosensor P. aeruginosa ΔrhlIR/pYC-rhlR (rhlIrhlR++) was developed. It was constructed through abolishing its BHL production by in-frame deletion of rhlIR and over-expressing rhlR by introducing a multi-copy plasmid pYC-rhlR into ΔrhlIR. By using the pigment production which responded to exogenous BHL as biosensor output, BHL quantification in samples was simply done spectrophotometrically. Under optimum conditions, the calibration curve had the limit of detection (LOD), the 50% activation/effect concentration, the limit of quantification (LOQ), and the quantitative detection range of 1.3 nM, 2.77 ± 0.45 μM, 5.7 nM and 0.11–49.7 μM, respectively. The biosensor output was stable, culture samples could be stored 10 days under −20 °C, and this sensing system was resistant to interferences by toxic aromatic pollutants. It was successfully applied to environmental samples even without extraction. The new whole-cell biosensing system provided a simple, stable, toxic pollutants-tolerant, and cost-effective tool for quantitative investigation of the QS signals’ role in environmental processes.  相似文献   

15.
Highly ordered Ni nanowire arrays (NiNWAs) were synthesized for the first time using a template-directed electropolymerization strategy with a nanopore polycarbonate (PC) membrane template, and their morphological characterization were examined by scanning electron microscopy (SEM) and transmission electron microscope (TEM). A NiNWAs based electrode shows very high electrochemical activity for electrocatalytic oxidation of glucose in alkaline medium, which has been utilized as the basis of the fabrication of a nonenzymatic biosensor for electrochemical detection of glucose. The biosensor can be applied to the quantification of glucose with a linear range covering from 5.0 × 10−7 to 7.0 × 10−3 M, a high sensitivity of 1043 μA mM−1 cm−2, and a low detection limit of 1 × 10−7 M. The experiment results also showed that the sensor exhibits good reproducibility and long-term stability, as well as high selectivity with no interference from other oxidable species.  相似文献   

16.
The effects of porphyritic andesite on the hydrolysis and acidogenesis of solid organic wastes were investigated by batch and continuous experiments using a rotational drum fermentation system. The results of the batch experiment show that if porphyritic andesite (1%, 3%, and 5% reactants) is added initially, the pH level increases and hydrolysis and acidogenesis are accelerated. The highest surface based hydrolysis constant (26.4 × 10−3 kg m−2 d−1) and volatile solid degradation ratio (43.3%) were obtained at a 1% porphyritic andesite addition. In the continuous experiment, porphyritic andesite elevated the first order hydrolysis constant from 13.10 × 10−3 d−1 to 18.82 × 10−3 d−1. A particle mean diameter reduction rate of 33.05 μm/d and a volatile solid degradation rate of 3.53 g/L d−1 were obtained under the hydraulic retention time of 4, 8, 12 and 16 d.  相似文献   

17.
A convenient and effective strategy for fabrication of hydrogen peroxide biosensor based on sodium alginate (SA) and polyvinyl butyral (PVB) as matrices was reported in this paper. The horseradish peroxidase (HRP) and SA were electro-co-deposited onto the surface of gold electrode, and the HRP–SA/Au electrode was further coated with PVB. The interaction between HRP and SA was characterized by UV–vis absorption spectroscopy, and the fabricating process of biosensor was characterized by electrochemical impedance spectroscopy (EIS). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. Experimental conditions were investigated which influence the performance of the biosensor, such as pH, and applied potential. The biosensor showed a linear response to H2O2 over a concentration range from 7.0 × 10−6 to 4.1 × 10−3 M with a detection limit of 1.8 × 10−6 M based on a signal-to-noise ratio of 3 under optimum conditions. The value of HRP in the composite was evaluated to be 1.38 mM. The biosensor obtained from this study possesses high sensitivity, good reproducibility, and long-term stability.  相似文献   

18.
One of the main challenges for scaling up microbial fuel cell (MFC) technologies is developing low-cost cathode architectures that can generate high power output. This study developed a simple method to convert non-conductive material (canvas cloth) into an electrically conductive and catalytically active cloth cathode assembly (CCA) in one step. The membrane-less CCA was simply constructed by coating the cloth with conductive paint (nickel-based or graphite-based) and non-precious metal catalyst (MnO2). Under the fed-batch mode, the tubular air-chamber MFCs equipped with Ni-CCA and graphite-CCA generated the maximum power densities of 86.03 and 24.67 mW m−2 (normalized to the projected cathode surface area), or 9.87 and 2.83 W m−3 (normalized to the reactor liquid volume), respectively. The higher power output of Ni-CCA-MFC was associated with the lower volume resistivity of Ni-CCA (1.35 × 10−2 Ω cm) than that of graphite-CCA (225 × 10−2 Ω cm). At an external resistance of 100 Ω, Ni-CCA-MFC and graphite-CCA-MFC removed approximately 95% COD in brewery wastewater within 13 and 18 d, and achieved coulombic efficiencies of 30.2% and 19.5%, respectively. The accumulated net water loss through the cloth by electro-osmotic drag exhibited a linear correlation (R2 = 0.999) with produced coulombs. With a comparable power production, such CCAs only cost less than 5% of the previously reported membrane cathode assembly. The new cathode configuration here is a mechanically durable, economical system for MFC scalability.  相似文献   

19.
A biotinylated mannotriose (Man3-bio) was dispersively immobilized in the matrix of biotinylated lactose (Gal-Glc-bio) on a streptavidin-covered, 27-MHz quartz crystal microbalance (QCM), and binding kinetics of concanavalin A (Con A) to Man3-bio in the Gal-Glc-bio matrix could be obtained from frequency decreases (mass increases) of the QCM. Association constants (Ka) and binding and dissociation rate constants (kon and koff) could be determined separately as the 1:1 and 1:2 bindings of Con A to Man3-bio on the surface. When Man3-bio was immobilized with content of 1 to 5 mol% in the matrix, the 1:1 binding of Con A to Man3-bio was obtained as Ka = (4 ± 1) × 106 M−1, kon = (4 ± 1) × 104 M−1 s−1, and koff = (12 ± 2) × 10–3 s−1. On the contrary, when Man3-bio was immobilized with content of 20 to 100 mol% in the matrix, the 1:2 binding of Con A to Man3-bio was obtained as Ka = (14 ± 2) × 106 M−1, kon = (14 ± 2) × 104 M−1 s−1, and koff = (7 ± 2) × 10–3 s−1. Thus, Ka for the 1:2 binding was 10 times larger than that for the 1:1 binding, with a three times larger binding rate constant (kon) and a three times smaller dissociation rate constant (koff). This is the first example to obtain separate kinetic parameters for the 1:1 and 1:2 bindings of lectins to carbohydrates on the surface.  相似文献   

20.
Using shipboard data collected from the central west Florida shelf (WFS) between 2000 and 2001, an optical classification algorithm was developed to differentiate toxic Karenia brevis blooms (>104 cells l−1) from other waters (including non-blooms and blooms of other phytoplankton species). The identification of K. brevis blooms is based on two criteria: (1) chlorophyll a concentration ≥1.5 mg m−3 and (2) chlorophyll-specific particulate backscattering at 550 nm ≤ 0.0045 m2 mg−1. The classification criteria yielded an overall accuracy of 99% in identifying both K. brevis blooms and other waters from 194 cruise stations. The algorithm was validated using an independent dataset collected from both the central and south WFS between 2005 and 2006. After excluding data from estuarine and post-hurricane turbid waters, an overall accuracy of 94% was achieved with 86% of all K. brevis bloom data points identified successfully. Satisfactory algorithm performance (88% overall accuracy) was also achieved when using underway chlorophyll fluorescence and backscattering data collected during a repeated alongshore transect between Tampa Bay and Florida Bay in 2005 and 2006. These results suggest that it may be possible to use presently available, commercial optical backscattering instrumentation on autonomous platforms (e.g. moorings, gliders, and AUVs) for rapid and timely detection and monitoring of K. brevis blooms on the WFS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号