首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
The aim of this study was to measure running times to exhaustion (Tlim) on a treadmill at 100% of the minimum velocity which elicits max max in 38 elite male long - distance runners max = 71.4 ± 5.5 ml.kg–1.min–1 and max = 21.8 ± 1.2 km.h–1). The lactate threshold (LT) was defined as a starting point of accelerated lactate accumulation around 4 mM and was expressed in max. Tlim value was negatively correlated with max (r = -0.362, p< 0.05) and max (r = –0.347, p< 0.05) but positively with LT (%v max) (r = 0.378, p < 0.05). These data demonstrate that running time to exhaustion at max in a homogeneous group of elite male long-distance runners was inversely related to max and experimentally illustrates the model of Monod and Scherrer regarding the time limit-velocity relationship adapted from local exercise for running by Hughson et al. (1984) .  相似文献   

2.
To assess the rate-limiting factor of oxygen uptake ( ) kinetics at the onset of exercise, six healthy male sedentary subjects performed repeated one-legged constant-load cycle exercise. The one-legged constant-load exercise test consisted of two 5-min periods of pedalling at an exercise intensity of 50 W, with a 5-min rest between periods (these exercise periods, i.e. first and second exercises, were performed by the same leg). The exercise was then repeated using the other leg. In addition, two-legged incremental exercise was investigated to establish whether kinetics were affected by slower heart rate kinetics. The incremental exercise test consisted of two-legged pedalling first with the cycle unloaded as a warm-up for 5 min followed by 50-W exercise for 5 min. The exercise intensity was then increased to 100 W for 5 min. During exercise, gas exchange parameters were determined by the breath-by-breath method and cardiac output ( ) was determined continuously by an impedance technique with a computer-based automated system. To determine the kinetics of heart rate (HR), and , a best fit procedure was employed using least-squares criteria with a time delay, except during the initial increase. During the one-legged constant-load exercise test, kinetics were significantly accelerated by repeated exercise using the same leg. On the other hand, when the exercise was changed to the other leg, kinetics were significantly slower, although kinetics continued to be faster. During the incremental exercise test, although the HR response was slower at the transition from 50-W to 100-W exercise than at the transition from warm-up to 50-W exercise, there were no significant changes in kinetics. These findings suggest that kinetics may be affected by metabolic conditions in the muscle, but not by blood flow ( and/or HR) kinetics.  相似文献   

3.
Summary Six Standardbred horses were used to evaluate the time course of pulmonary gas exchange, ventilation, heart rate (HR) and acid base balance during different intensities of constant-load treadmill exercise. Horses were exercised at approximately 50%, 75% and 100% maximum oxygen uptake ( max) for 5 min and measurements taken every 30 s throughout exercise. At all work rates, the minute ventilation, respiratory frequency and tidal volume reached steady state values by 60 s of exercise. At 100% max, the oxygen consumption ( ) increased to mean values of approximately 130 ml/kg·min, which represents a 40-fold increase above resting . At the low and moderate work rates, showed no significant change from 30 s to 300 s of exercise. At the high work rate, the mean at 30 s was 80% of the value at 300 s. The HR showed no significant change over time at the moderate work rate but differing responses at the low and high work rates. At the low work rate, the mean HR decreased from 188 beats/min at 30 s to 172 beats/min at 300 s exercise, whereas at the high work rate the mean HR increased from 204 beats/min at 30 s to 221 beats/min at 300 s exercise. No changes in acid base status occurred during exercise at the low work rate. At the moderate work rate, a mild metabolic acidosis occurred which was nonprogressive with time, whereas the high work rate resulted in a progressive metabolic acidosis with a base deficit of 16 mmol/l by 300 s exercise. It is concluded that the kinetics of gas exchange during exercise are more rapid in the horse than in man, despite the relatively greater change in in the horse when going from rest to high intensity exercise.Symbols and abbreviations E minute ventilation - V T tidal volume - oxygen uptake - carbon dioxide output - oxygen pulse - ventilatory equivalent for oxygen - ventilatory equivalent for carbon dioxide - R respiratory exchange ratio - HR heart rate - SBC standard bicarbonate - STPD standard temperature and pressure dry - BTPS body temperature and pressure saturated - arterial oxygen content - arteriovenous oxygen content difference - Rf respiratory frequency  相似文献   

4.
The aim of this study was to estimate the characteristic exercise intensity CL which produces the maximal steady state of blood lactate concentration (MLSS) from submaximal intensities of 20 min carried out on the same day and separated by 40 min. Ten fit male adults [maximal oxygen uptake max 62 (SD 7) ml · min–1 · kg–1] exercisOed for two 30-min periods on a cycle ergometer at 67% (test 1.1) and 82% of max (test 1.2) separated by 40 min. They exercised 4 days later for 30 min at 82% of max without prior exercise (test 2). Blood lactate was collected for determination of lactic acid concentration every 5 min and heart rate and O2 uptake were measured every 30 s. There were no significant differences at the 5th, 10th, 15th, 20th, 25th, or 30th min between , lactacidaemia, and heart rate during tests 1.2 and 2. Moreover, we compared the exercise intensities CL which produced the MLSS obtained during tests 1.1 and 1.2 or during tests 1.1 and 2 calculated from differential values of lactic acid blood concentration ([1a]b) between the 30th and the 5th min or between the 20th and the 5th min. There was no significant difference between the different values of CL [68 (SD 9), 71 (SD 7), 73 (SD 6),71 (SD 11) % of max (ANOVA test,P<0.05). Four subjects ran for 60 min at their CL determined from periods performed on the same day (test 1.1 and 1.2) and the difference between the [la]b at 5 min and at 20 min ( ([la]b)) was computed. The [la]b remained constant during exercise and ranged from 2.2 to 6.7 mmol · l–1 [mean value equal to 3.9 (SD 1) mmol · l–1]. These data suggest that the CL protocol did not overestimate the exercise intensity corresponding to the maximal fractional utilization of max at MLSS. For half of the subjects the CL was very close to the higher stage (82% of max where an accumulation of lactate in the blood with time was observed. It can be hypothesized that CL was very close to the real MLSS considering the level of accuracy of [la]b measurement. This study showed that exercise at only two intensities, performed at 65% and 80% of max and separated by 40 min of complete rest, can be used to determine the intensity yielding a steady state of [la–1]b near the real MLSS workload value.  相似文献   

5.
The effect of exercise training on heart rate variability (HRV) and improvements in peak oxygen consumption ( peak) was examined in sedentary middle-aged men. The HRV and absolute and relative peak of training (n = 19) and control (n = 15) subjects were assessed before and after a 24-session moderate intensity exercise training programme. Results indicated that with exercise training there was a significantly increased absolute and relative peak (P < 0.005) for the training group (12% and 11% respectively) with no increase for the control group. The training group also displayed a significant reduction in resting heart rate; however, HRV remained unchanged. The trained subjects were further categorized into high (n = 5) and low (n = 5) HRV groups and changes in peak were compared. Improvements in both absolute and relative peak were significantly greater (P > 0.005) in the high HRV group (17% and 20% respectively) compared to the low HRV group (6% and 1% respectively). The groups did not differ in mean age, pretraining oxygen consumption, or resting heart rate. These results would seem to suggest that a short aerobic training programme does not alter HRV in middle-aged men. Individual differences in HRV, however, may be associated with peak response to aerobic training.  相似文献   

6.
To determine the change in muscle oxygenation in response to progressively increasing work rate exercise, muscle oxyhemoglobin + oxymyoglobin saturation was measured transcutaneously with near infrared spectroscopy in the vastus lateralis muscle during cycle ergometry. Studies were done in 11 subjects while gas exchange was measured breath-by-breath. As work rate was increased, tissue oxygenation initially either remained constant near resting levels or, more usually, decreased. Near the work rate and metabolic rate where significant lactic acidosis was detected by excess CO2 production (lactic acidosis threshold, LAT), muscle oxygenation decreased more steeply. As maximum oxygen uptake ( ) was approached, the rate of desaturation slowed. In 8 of the 11 subjects, tissue O2 saturation reached a minimum which was sustained for 1–3 min before was reached. The LAT correlated with both the (r = 0.95,P < 0.0001) and the work rate (r = 0.94,P < 0.0001) at which the rate of tissue O2 desaturation accelerated. These results describe a consistent pattern in the rate of decrease in muscle oxygenation, slowly decreasing over the lower work rate range, decreasing more rapidly in the work rate range of the LAT and then slowing at about 80% of , approaching or reaching a minimum saturation at .  相似文献   

7.
The liver is central to the metabolic response to exercise but measurements of effects of reduced liver function on the physiological adaptation to exercise are scarce. We investigated metabolic, endocrine, pulmonary and haemodynamic responses to exercise in 15 healthy untrained controls (Co) and in 30 subjects with reduced liver function (i.e. liver cirrhosis, Ci). The following protocols were used: protocol 1 maximal oxygen uptake and anaerobic threshold (AT), protocol 2 stepwise increases in exercise intensity from 0 to 40% giving steady-stage conditions, protocol 3 1 h exercise at 20% . Muscle glycogen content was determined in 15 Ci. Spirometry was essentially normal in Ci. Result: protocol 1 Ci had impaired and reduced AT (P < 0.05). Basal plasma concentrations of insulin, glucagon, growth hormone and adrenaline were increased in Ci (P < 0.05); cortisol was normal. During exercise, only glucagon remained different between groups. In protocol 2 Ci had decreased resting respiratory exchange ratio (RQ: p < 0.05) associated with increased plasma concentrations of free fatty acids and glycerol. They had disproportionately enhanced lipolysis and RQ. heart rate (+ 24%), ventilation (+ 28%), thermal effects of exercise (+ 31%) and intrapulmonary shunt volume (+ 76%), which accounted for 11.7 (SD 3.0) or 7.4 (SD 0.9%) of cardiac output during exercise in Ci and Co, respectively (P < 0.05 for all the differences reported). The metabolic effects of Ci were independent of the clinical and nutritional state of the patients. In protocol 3 muscle glycogen content was highly variable in Ci, but mean values were normal [16.9 (SD 8.9) mol·g–1 wet mass]. Glycogen content positively correlated with resting and exercise-induced RQ, but negatively correlated with the exercise-induced alterations in plasma glucose concentration. From these results we concluded that with reduced liver function , and AT are reduced, but metabolic, pulmonary and haemodynamic reponses per unit power output are enhanced. Muscle glycogen content would seem to contribute to the metabolic response, but its mobilization to be limited in individuals with reduced liver function.Dedicated to Professor D.F.W. Schmidt on the occasion of his 70th birthday  相似文献   

8.
Summary Nest humidity ( ) under an incubating bantam hen was measured at ambient ranging from 1.3 to 25.0 mmHg. Weight loss of eggs was recorded in clutches of varying size. Nest and ambient were also measured in wild incubating willow ptarmigan nests in dry and wet habitats.Nest increased linearly with ambient in a way predictable on the assumption that the water vapour conductance ( ) of brood patch skin, plumage and eggs were constant and independent of ambient . Nest was also dependent of clutch size. Egg dehydration was quantitatively predicted from measured values and the laws of diffusion.Our findings confirm earlier conclusions that the adult bird does not actively regulate nest at varying ambient . Birds can presumably achieve appropriate egg dehydration by a strategy combining nest site, nest construction, egg shell conductance and incubation behaviour which meets the requirements of their breeding climate.Abbreviations water vapur pressure - water vapur conductance - water flux  相似文献   

9.
Summary The energy requirements of Adélie penguin (Pygoscelis adeliae) chicks were analysed with respect to body mass (W, 0.145–3.35 kg, n=36) and various forms of activity (lying, standing, minor activity, locomotion, walking on a treadmill). Direct respirometry was used to measure O2 consumption ( ) and CO2 production. Heart rate (HR, bpm) was recorded from the ECG obtained by both externally attached electrodes and implantable HR-transmitters. The parameters measured were not affected by hand-rearing of the chicks or by implanting transmitters. HR measured in the laboratory and in the field were comparable. Oxygen uptake ranged from in lying chicks to at maximal activity, RQ=0.76. Metabolic rate in small wild chicks (0.14–0.38 kg) was not affected by time of day, nor was their feeding frequency in the colony (Dec 20–21). Regressions of HR on were highly significant (p< 0.0001) in transmitter implanted chicks (n=4), and two relationships are proposed for the pooled data, one for minor activities ( ), and one for walking ( ). Oxygen consumption, mass of the chick (2–3 kg), and duration of walking (T, s) were related as , whereas mass-specific O2 consumption was related to walking speed (S, m·s-1) as .Abbreviations bpm beats per minute - D distance walked (m) - ECG electrocardiogram - HR heart rate (bpm) - ns number of steps - RQ respiratory quotient - S walking speed (m·s-1) - T time walked (s) - W body mass (kg)  相似文献   

10.
The position of the body and use of the respiratory muscles in the act of rowing may limit ventilation and thereby reduce maximal aerobic power relative to that achieved in cycling or running, in spite of the greater muscle mass involved in rowing. This hypothesis was investigated for three groups of male subjects: nine elite senior oarsmen, eight former senior oarsmen and eight highly trained athletes unskilled in rowing. The subjects performed graded exercise to maximal effort on a rowing ergometer, cycle ergometer and treadmill while respiratory minute volume and oxygen consumption were monitored continuously. The VE at a given during intense submaximal exercise (greater than 75% of maximal ) was not significantly lower in rowing compared with that in cycling and treadmill running for any group, which would suggest that submaximal rowing does not restrict ventilation. At maximal effort, and for rowing were less than those for the other types of exercise in all the groups, although the differences were not statistically significant in the elite oarsmen. These data are consistent with a ventilatory limitation to maximal performance in rowing that may have been partly overcome by training in the elite oarsmen. Alternatively, a lower maximal VE in rowing might have been an effect rather than a cause of a lower maximal if maximal was limited by the lower rate of muscle activation in rowing.  相似文献   

11.
Summary In a data base consisting of 1665 pairs of loci linkage between Inv and Jk is significant . Recombination is nearly the same in the two sexes . The reason why this linkage was not noticed earlier is discussed.  相似文献   

12.
Summary Adelie penguins (Pygoscelis adeliae) experience a wide range of ambient temperatures (T a) in their natural habitat. We examined body temperature (T b), oxygen consumption ( ), carbon dioxide production ( ), evaporative water loss ( ), and ventilation atT a from –20 to 30 °C. Body temperature did not change significantly between –20 and 20°C (meanT b=39.3°C).T b increased slightly to 40.1 °C atT a=30°C. Both and were constant and minimal atT a between –10 and 20°C, with only minor increases at –20 and 30°C. The minimal of adult penguins (mean mass 4.007 kg) was 0.0112 ml/[g·min], equivalent to a metabolic heat production (MHP) of 14.9 Watt. The respiratory exchange ratio was approximately 0.7 at allT a. Values of were low at lowT a, but increased to 0.21 g/min at 30°C, equivalent to 0.3% of body mass/h. Dry conductance increased 3.5-fold between –20 and 30°C. Evaporative heat loss (EHL) comprised about 5% of MHP at lowT a, rising to 47% of MHP atT a=30°C. The means of ventilation parameters (tidal volume [VT], respiration frequency [f], minute volume [I], and oxygen extraction [ ]) were fairly stable between –20 and 10°C (VT did not change significantly over the entireT a range). However, there was considerable inter- and intra-individual variation in ventilation patterns. AtT a=20–30°C,f increased 7-fold over the minimal value of 7.6 breaths/min, and I showed a similar change. fell from 28–35% at lowT a to 6% atT a=30°C.Abbreviations C thermal conductance - EHL evaporative heat loss - oxygen extraction - f respiratory frequency - MHP metabolic heat production - evaporative water loss - LCT lower critical temperature - RE respiratory exchange ratio - T a ambient temperature - T b body temperature - rate of oxygen consumption - rate of carbon dioxide production - I inspiratory minute volume - VT tidal volume  相似文献   

13.
Summary Rainbow trout (Salmo gairdneri) were exposed to acidic soft water (pHin4.2–6.3) in the presence (93 g·l–1) or absence of Al. Fish were fitted with latex masks and opercular catheters to measure ventilation , pH changes at the gills, O2 consumption , ammonia excretion , and Al extraction. During 2–3-h exposures, was generally higher in Al-exposed fish over the pHin range 4.7–6.3. Alkalinization of expired water was about 0.3 pH units less in Al-exposed fish than in acid-only exposed fish at pHin 4.5–5.2, an effect attributable to both increased and to buffering by Al. During 44-h exposures to pHin 5.2 and 4.8 plus Al, increased greatly and expired water pH (pHex) decreased with time. There was a small increase in over 44 h at pH 4.4 plus Al, and no changes in pHex. In contrast, during 44-h exposures to pH 5.2, 4.8, and 4.4 in the absence of Al, such changes were much smaller or absent. During both short- and longerterm exposures, measured Al accumulation on the gills was only 5–18% of that calculated from cumulative Al extraction from the water, suggesting considerable sloughing of Al. In free-swimming trout, gill Al accumulation was greatest during exposure (2h) to Al at pH 5.2, lower at pH 4.8, and least at pH 4.4 and 4.0. Our results suggest that Al deposition occurs at the gills, causing respiratory and ionoregulatory toxicity, because the pH in the branchial micro-environment is raised above that in the acidic inspired soft water. Higher pH at fish gills may result in Al precipitation due to loss of solubility, or Al accumulation because of shifts in Al species to Al-hydroxide forms which more readily adsorb to the gills.Abbreviations pH ex expired pH - pH in inspired pH  相似文献   

14.
We investigated the aerobic and anaerobic contributions to performance during the Wingate test in sprint and middle-distance runners and whether they were related to the peak aerobic and anaerobic performances determined by two commonly used tests: the force-velocity test and an incremental aerobic exercise test. A group of 14 male competitive runners participated: 7 sprinters, aged 20.7 (SEM 1.3) years, competing in 50, 100 and 200-m events and 7 middle-distance runners, aged 20.0 (SEM 1.0) years, competing in 800, 1,000 and 1,500 m-events. The oxygen uptake ( ) was recorded breath-by-breath during the test (30 s) and during the first 20 s of recovery. Blood samples for venous plasma lactate concentrations were drawn at rest before the start of the test and during the 20-min recovery period. During the Wingate test mean power ( ) was determined and three values of mechanical efficiency, one individual and two arbitrary, 16% and 25%, were used to calculate the contributions of work by aerobic ( aer,ind,16%,25%) and anaerobic ( an,ind,16%,25%) processes. Peak anaerobic power ( an,peak) was estimated by the force-velocity test and maximal aerobic energy expenditure ( aer,peak) was determined during an incremental aerobic exercise test. During the Wingate test, the middle-distance runners had a significantly greater than the sprinters (P < 0.001), who had significantly greater venous plasma lactate concentrations (P < 0.001). Moreover, aer,ind,16%,25% were also significantly higher (P < 0.05) in the middle-distance runners [ aer,ind 45 (SEM 4) % vs 28 (SEM 2) %; aer,16% 30 (SEM 3) % vs 19 (SEM 2) %; aer,25% 46 (SEM 3) % vs 29 (SEM 2)%]; an,ind,16%,25% in the sprint runners (P < 0.05) [ an,ind 72 (SEM 3) % vs 55 (SEM 4) %; an,16% 81 (SEM 2) % vs 70 (SEM 3) %; an,25% 71 (SEM 2) % vs 54 (SEM 3) %]. The aer,ind/ aer,peak and × an,ind/ an,peak ratios, however, were not significantly different between the two groups of athletes. These results would indicate that the sprinters and middle-distance runners used preferentially a metabolic system according to their speciality. Nevertheless, under the conditions of its experiment, they seemed to rely on the same percentage of both peak anaerobic and peak aerobic performance for a given exercise task.  相似文献   

15.
Summary The effects of different ambient temperatures (T a) on gas exchange and ventilation in deer mice (Peromyscus maniculatus) were determined after acclimation to low and high altitude (340 and 3,800 m).At both low and high altitude, oxygen consumption ( ) decreased with increasingT a atT a from –10 to 30 °C. The was 15–20% smaller at high altitude than at low altitude atT a below 30 °C.Increased atT a below thermoneutrality was supported by increased minute volume ( ) at both low and high altitude. At mostT a, the change in was primarily a function of changing respiration frequency (f); relatively little change occurred in tidal volume (V T) or oxygen extraction efficiency (O2EE). AtT a=0 °C and below at high altitude, was constant due to decliningV T and O2EE increased in order to maintain high .At high altitude, (BTP) was 30–40% higher at a givenT a than at low altitude, except atT a below 10 °C. The increased at high altitude was due primarily to a proportional increase inf, which attained mean values of 450–500 breaths/min atT a below 0 °C. The (STP) was equivalent at high and low altitude atT a of 10 °C and above. At lowerT a, (STPD) was larger at low altitude.At both altitudes, respiratory heat loss was a small fraction (<10%) of metabolic heat production, except at highT a (20–30 °C).Abbreviations EHL evaporative heat loss - f respiration frequency - HL a heat loss from warming tidal air - HL e evaporative heat loss in tidal air - HL total respiratory heat loss - MHP metabolic heat production - O 2 EE oxygen extraction efficiency - RQ respiratory quotient - T a ambient temperature - T b body temperatureT lc lower critical temperature - carbon dioxide production - evaporative water loss - oxygen consumption - minute volume - V T tidal volume  相似文献   

16.
Summary The Lipari-Szabo dynamical formalism is extended by setting the time constants of the Lorentzian terms to and . This analysis is compared to the earlier proposed three-parameter extended model free formalism with regard to the range of equivalence and the advantages of the simplified two-parameter (S inff sup2 ,S infH sup2 ) and (S inff sup2 ,S infN sup2 ) representations. Spectral density components are calculated and compared to those obtained from the spectral density analysis formalism. Protein relaxation data, commonly analyzed in terms of the two-parameter representation, may correspond to a dynamically heterogeneous behaviour that is more appropriately represented in terms of a fast limit order parameter and a second, lower frequency order parameter.  相似文献   

17.
Gill function in an elasmobranch   总被引:1,自引:0,他引:1  
Summary Highly efficient oxygen uptake in elasmobranchs, as indicated by frequent excess of over has previously been ascribed to the operation of multicapillary rather than counter-current gas exchange by the gills. Analysis of models shows that, at maximum efficiency, a multicapillary system cannot account for values of greater than . In Port Jackson sharks Heterodontus portusjacksoni) commonly exceeds , which indicates the operation of a functional counter-current at the respiratory surface. The anatomical basis of this counter-current is provided by the demonstration that a continuous flow of water passes between the secondary lamellae into septal canals and thence via the parabranchial cavities to the exterior.Queen Elizabeth II Fellow.  相似文献   

18.
We investigated whether the spontaneous transition between walking and running during moving with increasing speed corresponds to the speed at which walking becomes less economical than running. Seven active male subjects [mean age, 23.7 (SEM 0.7) years, mean maximal oxygen uptake ( ), 57.5 (SEM 3.3) ml·kg –1·min –1, mean ventilatory threshold (VTh), 37.5 (SEM 3) ml·kg –1 ·min –1] participated in this study. Each subject performed four exercise tests separated by 1-week intervals: test 1, and VTh were determined; test 2, the speed at which the transition between walking and running spontaneously occurs (ST) during increasing speed (increases of 0.5 km·h –1 every 4 min from 5 km·h –1) was determined; test 3, the subjects were constrained to walk for 4 min at ST, at ST ± 0.5 km·h –1 and at ST ± 1 km·h –1; and test 4, the subjects were constrained to run for 4 min at ST, at ST±0.5 km·-h –1 and at ST±1 km·h –1. During exercise, oxygen uptake ( ), heart rate (HR), ventilation ( ), ventilatory equivalents for oxygen and carbon dioxide (% MathType!MTEF!2!1!+-% feaafiart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGabmOvayaaca% WaaSbaaSqaaiaabweaaeqaaOGaai4laiqadAfagaGaamaaBaaaleaa% caqGYaaabeaakiaacYcacaqGGaGaaeiiaiqadAfagaGaamaaBaaale% aacaqGfbaabeaakiaac+caceWGwbGbaiaacaqGdbGaae4tamaaBaaa% leaacaaIYaaabeaaaaa!4240!\[\dot V_{\text{E}} /\dot V_{\text{2}} ,{\text{ }}\dot V_{\text{E}} /\dot V{\text{CO}}_2 \]), respiratory exchange ratio (R), stride length (SL), and stride frequency (SF) were measured. The results showed that: ST occurred at 2.16 (SEM 0.04) m·s –1; , HR and speed at ST were significantly lower than the values measured at VTh (P< 0.001, P< 0.001 and P< 0.05, respectively); changed significantly with speed (P< 0.001) but was greater during running than walking below ST (ST minus 1 km·h –1, P< 0.001; ST minus 0.5 km·h –1, P< 0.05) with the converse above ST (ST.plus 1 km·h –1, P<0.05), whereas at ST the values of were very close [23.9 (SEM 1.1) vs 23.7 (SEM 0.8) ml·kg –1 · min –1 not significant, respectively, for walking and running]; SL was significantly greater during walking than running (P<0.001) and SF lower (P<0.001); and HR and were significantly greater during running than walking below ST (ST minus 1 km·h –1, P<0.01; ST minus 0.5 km·h –1, P{<0.05) with the converse above ST (ST plus 1 km·h –1, P·< 0.05), whereas no difference appeared for and R between the two types of locomotion. We concluded from this study that ST corresponded to the speed at which the energy expenditure of running became lower than the energy expenditure of walking but that the mechanism of the link needed further investigation.  相似文献   

19.
The purpose of the present study was to assess the relationship between the rapidity of increased gas exchange (i.e. oxygen uptake ) and increased cardiac output ( ) during the transient phase following the onset of exercise. Five healthy male subjects performed multiple rest-exercise or light exercise (25 W)-exercise transitions on an electrically braked ergometer at exercise intensities of 50, 75, or 100 W for 6 min, respectively. Each transition was performed at least eight times for each load in random order. The was obtained by a breath-by-breath method, and was measured by an impedance method during normal breathing, using an ensemble average. On transitions from rest to exercise, rapidly increased during phase I with time constants of 6.8–7.3 s. The also showed a similar rapid increment with time constants of 6.0–6.8 s with an apparent increase in stroke volume (SV). In this phase I, increased to about 29.7%–34.1% of the steady-state value and increased to about 58.3%–87.0%. Thereafter, some 20 s after the onset of exercise a mono-exponential increase to steady-state occurred both in and with time constants of 26.7–32.3 and 23.7–34.4 s, respectively. The insignificant difference between and time constants in phase I and the abrupt increase in both and SV at the onset of exercise from rest provided further evidence for a cardiodynamic contribution to following the onset of exercise from rest.  相似文献   

20.
Summary The resting oxygen consumption and breathing pattern of nine newborn and adult species (ranging in body size from mouse to human) have been compared on the basis of data collected from the literature. Minute ventilation is similarly linked to at both ages, the percent of extracted as O2 about 2.2. Tidal volume/kg is an interspecies constant in newborns and adults, approximately 8 ml/kg. Breathing frequency decreases with the increase in size in a different way at the two ages: large species have newborns breathing at rates 2–3 times above the corresponding adults' values, while in the small species newborns and adults breathe at almost the same rate. Therefore the newborns of the smallest species have both and below the expected values, implying a greater inability to cope with the external demands than newborns of larger species. Several considerations indicate that in the smallest newborns the mechanical properties of the respiratory system could be a constraint to resting ventilations larger than observed. It is therefore possible that their low is the cause, and not the effect, of the relatively small .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号