首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
For the first time, an LC–MS–MS method has been developed for the simultaneous analysis of buprenorphine (BUP), norbuprenorphine (NBUP), and buprenorphine–glucuronide (BUPG) in plasma. Analytes were isolated from plasma by C18 SPE and separated by gradient RP-LC. Electrospray ionization and MS–MS analyses were carried out using a PE-Sciex API-3000 tandem mass spectrometer. The m/z 644→m/z 468 transition was monitored for BUPG, whereas for BUP, BUP-d4, NBUP, and NBUP-d3 it was necessary to monitor the surviving parent ions in order to achieve the required sensitivity. The method exhibited good linearity from 0.1 to 50 ng/ml (r2≥0.998). Extraction recovery was higher than 77% for BUPG and higher than 88% for both BUP and NBUP. The LOQ was established at 0.1 ng/ml for the three analytes. The method was validated on plasma samples collected in a controlled intravenous and sublingual buprenorphine administration study. Norbuprenorphine–glucuronide was also tentatively detected in plasma by monitoring the m/z 590→m/z 414 transition.  相似文献   

2.
An LCMSMS method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-glucuronide (BUP-Gluc), and norbuprenorphine-glucuronide (NBUP-Gluc) in 0.5 mL plasma, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. Transitions monitored were 468.3 > 396.2 and 468.3 > 414.3 for BUP, 414.3 > 340.1 and 414.3 > 326.0 for NBUP, 644.3 > 468.1 and 644.3 > 396.3 for BUP-Gluc, and 590.3 > 414.3 and 590.3 > 396.2 for NBUP-Gluc. Linearity was 0.1–50 ng/mL for BUP and BUP-Gluc, and 0.5–50 ng/mL for NBUP and NBUP-Gluc. Intra-day, inter-day, and total assay imprecision (%RSD) were <16.8%, and analytical recoveries were 88.6–108.7%. Extraction efficiencies ranged from 71.1 to 87.1%, and process efficiencies 48.7 to 127.7%. All compounds showed ion enhancement, except BUP-Gluc that demonstrated ion suppression: variation between 10 different blank plasma specimens was <9.1%. In six umbilical cord plasma specimens from opioid-dependent pregnant women receiving 14–24 mg/day BUP, NBUP-Gluc was the predominant metabolite (29.8 ± 7.6 ng/mL), with BUP-Gluc (4.6 ± 4.8 ng/mL), NBUP (1.5 ± 0.8 ng/mL) and BUP (0.4 ± 0.2 ng/mL). Although BUP biomarkers can be quantified in umbilical cord plasma in low ng/mL concentrations, the significance of these data as predictors of neonatal outcomes is currently unknown.  相似文献   

3.
A rapid and inexpensive micro-assay for determining cholesterol in plasma and isolated lipoprotein fractions has been established which utilizes a commercially available enzymatic reagent with semi-automated instruments and microtiter plates. The assay is sensitive, precise, and easy to perform. The color development is linear from 0.4 to 20 micrograms cholesterol/well, with sample volumes of 2 to 100 microliters. Inter- and intra-assay variability yielded coefficients of variation (CV) of 2.75% (n = 51) and 1.09% (n = 32), respectively. The concentrations of total plasma and lipoprotein cholesterol (d greater than 1.006 g/ml) obtained with this method were compared with those analyzed in a lipid laboratory standardized to the Centers for Disease Control. The correlation coefficients between the two methods were 0.976 and 0.964, respectively. For total high density lipoprotein (HDL) and the HDL3 subfraction, inter-assay variability was 4.12% and 6.33% (n = 27), respectively; the intra-assay variability was 2.79% and 4.19% (n = 12).  相似文献   

4.
A simple and rapid high performance liquid chromatographic method for the determination of plasma amino acids was developed. The method uses minimal sample volume and automated online precolumn derivitization of amino acids with o-phthalaldehyde and fluorescent detection. Amino acids are separated by a simplified gradient without column heating. The assay is linear from 5 to 1000 micromol/L for all amino acids. Recovery of amino acids was between 91 and 108%, intra-assay coefficient of variation (CV) was 1-7%, and inter-assay CV was 2-12%. The simple sample preparation and minimal sample volume make the method useful for the quantitation of amino acids in both patient and experimental animal samples.  相似文献   

5.
We have developed a sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantification of midazolam (MDZ) and its major metabolite, 1'-hydroxymidazolam (1'-OHM) in a small volume (200 microl) of human plasma. Midazolam, 1'-OHM and 1'-chlordiazepoxide (internal standard) were extracted from alkalinised (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with 1-chlorobutane. The chromatographic separation was performed on a reversed-phase HyPURITY Elite C18 (5 microm particle size; 100 mm x 2.1mm i.d.) analytical column using an acidic (pH 2.8) mobile phase (water-acetonitrile; 75:25% (v/v) containing formic acid (0.1%, v/v)) delivered at a flow-rate of 200 microl/min. The mass spectrometer was operated in the positive ion mode at the protonated-molecular ions [M+l]+ of parent drug and metabolite. Calibration curves in spiked plasma were linear (r2 > or = 0.99) from 15 to 600 ng/ml (MDZ) and 5-200 ng/ml (1'-OHM). The limits of detection and quantification were 2 and 5 ng/ml, respectively, for both MDZ and 1'-OHM. The mean relative recoveries at 40 and 600 ng/ml (MDZ) were 79.4+/-3.1% (n = 6) and 84.2+/-4.7% (n = 8), respectively; for 1'-OHM at 30 and 200 ng/ml the values were 89.9+/-7.2% (n = 6) and 86.9+/-5.6% (n = 8), respectively. The intra-assay and inter-assay coefficients of variation (CVs) for MDZ were less than 8%, and for 1'-OHM were less than 13%. There was no interference from other commonly used antimalarials, antipyretic drugs and antibiotics. The method was successfully applied to a pharmacokinetic study of MDZ and 1'-OHM in children with severe malaria and convulsions following administration of MDZ either intravenously (i.v.) or intramuscularly (i.m.).  相似文献   

6.
The evidence for direct muscle relaxant effects of benzodiazepines is controversial. We now show that a crude membrane preparation of rat diaphragm possesses binding sites for [3H]flunitrazepam (FNZ). Scatchard analysis gave a binding site density of 1689 +/- 143 fmol/mg protein (Kd = 25.6 +/- 2.6 nM). These sites are of the "peripheral" type since clonazepam fails to displace [3H]FNZ as effectively as R05-4864 (IC50 values: 7.5 x 10(-6) M and 8 x 10(-9) M, respectively). Diazepam is almost as effective as R05-4864 and potently displaces [3H]FNZ binding (IC50 = 3 x 10(-8) M). We propose that the previously described effects of diazepam on rat diaphragm are mediated through high-affinity binding sites.  相似文献   

7.
We report here a quantitative method for the analysis of ABT-578 in human whole blood samples. Sample preparation was achieved by a semi-automated 96-well format liquid-liquid extraction (LLE) method. Aluminum/polypropylene heat seal foil was used to enclose each well of the 96-well plate for the liquid-liquid extraction. A liquid chromatography combined with tandem mass spectrometry (LC-MS/MS) method with pre-column regeneration was developed for the analysis of sample extracts. Selective reaction monitoring (SRM) of the mass transitions m/z 983-935 and m/z 931-883 was employed for the detection of ABT-578 and internal standard, respectively. The ammonium adduct ions [M + NH(4)](+) generated from electrospray ionization were monitored as the precursor ions. The assay was validated for a linear dynamic range of 0.20-200.75ng/ml. The correlation coefficient (r) was between 0.9959 and 0.9971. The intra-assay CV (%) was between 1.9 and 13.5% and the inter-assay CV (%) was between 4.7 and 11.3%. The inter-assay mean accuracy was between 86.4 and 102.5% of the theoretical concentrations.  相似文献   

8.
A simple and rapid assay is described for the simultaneous analysis of levodopa (l-DOPA) and 3-O-methyldopa (3-OMD) in human plasma samples, applying an ion-pair reversed-phase liquid chromatographic method with electrochemical detection, designed for clinical trials performed to study the effect of peripheral catechol-O-methyltransferase inhibitors on the metabolism of l-DOPA. After protein precipitation of 100 microl plasma sample aliquots with perchloric acid, the analytes are directly injected, separated within 10 min and simultaneously quantified down to 20 ng/ml by an electrochemical detector equipped with a dual-electrode system operating in redox mode eliminating effectively potential endogenous and exogenous interferences. The intra-assay precision for l-DOPA and 3-OMD was 1.34-6.54 and 3.90-5.50%, whereas the inter-assay precision was 2.09-7.69 and 4.16-9.90%, respectively. The recoveries were close to 90% for l-DOPA and almost 100% for 3-OMD. Satisfactory storage stability was achieved for up to 16 weeks at -70 degrees C by stabilizing plasma samples with antioxidants.  相似文献   

9.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of piroxicam, meloxicam and tenoxicam in human plasma was developed. Piroxicam, meloxicam, tenoxicam and isoxicam (internal standard) were extracted from human plasma with ethyl acetate at acidic pH and analyzed on a Sunfire column with the mobile phase of methanol:ammonium formate (15 mM, pH 3.0) (60:40, v/v). The analytes were detected using a mass spectrometer, equipped with electrospray ion source. The instrument was set in the multiple-reaction-monitoring (MRM) mode. The standard curve was linear (r=1.000) over the concentration range of 0.50-200 ng/ml. The coefficient of variation (CV) and relative error (RE) for intra- and inter-assay statistics at three QC levels were 1.0-5.4% and -5.9 to 2.8%, respectively. The recoveries of piroxicam, meloxicam and tenoxicam ranged from 78.3 to 87.1%, with that of isoxicam being 59.7%. The lower limit of quantification for piroxicam, meloxicam and tenoxicam was 0.50 ng/ml using a 100 microl plasma sample. This method was successfully applied to a pharmacokinetic study of piroxicam after application of transdermal piroxicam patches to humans.  相似文献   

10.
A method for the analysis of [1-(4-aminophenyl)-3,5-dihydro-7,8-dimethoxy-4H-2,3-benzodiazepin-4-one] (CFM-2) and its analogues CFM-3, CFM-4 and CFM-5 in rat plasma was developed. The 2,3-benzodiazepines (2,3-BZs) were extracted by liquid–liquid extraction and analyzed using high-performance liquid chromatography (HPLC) with ultraviolet detection (UV) at 240 nm. The method exhibited a large linear range from 0.05 to 2 μg/ml with an intra-assay accuracy for all studied compounds ranging from 92 to 105.5%; whereas the intra-assay precision ranged from 0.59 to 8.16% in rat plasma. The inter-assay accuracy of CFM-2, CFM-4 and their 3-methyl derivatives, CFM-3 and CFM-5 ranged from 92.2 to 107% and the inter-assay precision ranged from 2.17 to 11.9% in rat plasma. The lower limit of detection was 5.5 ng/ml for CFM-2, 6.5 ng/ml for CFM-3, 7 ng/ml for CFM-4 and 8.5 ng/ml for CFM-5 in rat plasma. The pharmacokinetic study demonstrated that 2,3-BZs achieved a peak plasma concentration between 45 and 75 min after drug administration. Moreover, we observed that plasma chromatograms of rats treated with CFM-3, CFM-4 and CFM-5, respectively, showed a peak consistent with CFM-2. Our study suggests that CFM-4, CFM-5 and CFM-3 are prodrugs of CFM-2, in which they are biotransformed in vivo via different metabolic pathways. In particular, CFM-2 has been proven to possess anticonvulsant activity in various models of seizures, acting as α-amino-3-hydroxy-5-methyl-isoxazole-4-propionate (AMPA) receptor antagonist.  相似文献   

11.
We have developed a sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection (340 nm) for the simultaneous quantification of amodiaquine (AQ) and its major metabolite, desethylamodiaquine (AQm) in a small volume (200 microl) of whole blood spotted on filter paper. The method involves liquid-liquid extraction with diethyl ether followed by elution from a reversed-phase phenyl column with an acidic (pH 2.8) mobile phase (25 mM KH2PO4-methanol; 80:20% (v/v) +1% (v/v) triethylamine). Calibration curves in spiked whole blood were linear from 100-2500 ng/ml (r2 > or = 0.99) for AQ and 200-2500 ng/ml (r2 > or = 0.99) for AQm. The limit of detection was 5 ng for AQ and 10 ng for AQm. The relative recovery at 150 ng/ml of AQ (n = 6) was 84.0% and at 300 ng/ml of AQm the relative recovery was 74.3%. The intra-assay coefficients of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 7.7, 8.9 and 6.2% (AQ) and 10.1, 5.4 and 3.9% (AQm), respectively. The inter-assay coefficient of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 5.2, 8.1 and 6.9% (AQ) and 3.3, 2.3 and 4.6% (AQm). There was no interference from other commonly used antimalarial and antipyretic drugs (chloroquine, quinine, sulfadoxine, pyrimethamine, artesunate, acetaminophen and salicylate). The method is particularly suitable for pharmacokinetic studies in settings where facilities for storing blood/plasma samples are not available.  相似文献   

12.
Adrenal steroid profiling, including 17α-OH progesterone (17OHP), 11-deoxycortisol (S), Δ4-androstenedione (Δ4-A) and cortisol (F) in blood spots by tandem mass spectrometry, is used for newborn screening to detect congenital adrenal hyperplasia (CAH). Pre-analytical sample processing is critical for assay specificity and accuracy; however, it is laborious and time-consuming. This study describes the development and validation of a new Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method for the simultaneous quantification of five steroids: 17OHP, S, Δ4-A, F and cortisone (E) in blood spots from newborns. Whole blood was eluted from a 5.00 mm dried blood spot by an aqueous solution containing the deuterium-labeled internal standards d8-17OHP and d4-cortisol. The steroids extracted from blood spot into aqueous solution were subsequently purified via Extelut mini NT1 column using diethylether. The extracts were evaporated and quantified using LC-MS/MS. The detection limit was 0.25 ng/mL for 17OHP and S, 0.4 ng/mL for Δ4-A and 0.5 ng/mL for F and E. The limit of quantification was 0.5 ng/mL for 17OHP, S and Δ4-A and 1 ng/mL for F and E. Precision for 17OHP, S, Δ4-A at concentrations of 0.5, 2, and 8 ng/mL (n=5) in fortified steroid free serum samples was 1.3-3.5% (intra-assay CV) and 7-14.8% (inter-assay CV). Precision for F and E at concentrations of 5 and 20 ng/mL was 1.5-4.8% (intra-assay, CV%) and 6-15% (inter-assay, CV%). Accuracy was calculated at concentrations of 0.5, 2, and 8 ng/mL for 17OHP, S and Δ4-A and ranged from -0.3 to 0.2%, while for F and E it ranged from -3.2 to 0.2%. Relative recoveries at concentration 2 ng/mL and 8 ng/mL for 17OHP, S, Δ4-A and at 5 ng/mL and 20 ng/mL for F and E ranged from 55% to 80%. Reference intervals were estimated for all steroids in newborns (on day 3). The steroid profile assay herein described is sensitive, specific and accurate and involves a simple pre-analytical sample manipulation; it is therefore suitable for routine analysis and provides data for samples within normal range as well as those with elevated levels. For the first time to our knowledge, cortisone levels are reported in dried blood spots from newborns.  相似文献   

13.
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-μl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile–phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between- and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.  相似文献   

14.
A high-performance liquid chromatographic method coupled with tandem mass spectrometry detection has been developed for the determination of propofol and its main glucuroconjugate metabolites (propofol-glucuronide (PG), 1-quinol-glucuronide (1-QG) and 4-quinol-glucuronide (4-QG) in human plasma. All compounds were extracted with a single solid phase extraction procedure using Max Oasis cartridges. Propofol and thymol (internal standard) were analyzed using a C8 reversed-phase column with a mobile phase consisting of methanol-water (75:25, v/v) containing 0.025% NH(4)OH. Chromatography of glucuroconjugate metabolites and phenyl-beta-d-glucuronide (internal standard) was performed using a hydrophilic interaction liquid chromatography (HILIC) and a mixture of acetonitrile/water/ammonium acetate buffer (100 mM, pH 5, 87/1/12, v/v/v). Both chromatographic separations were achieved in isocratic mode allowing a rapid analysis without re-equilibration of the phase. The method is specific and sensitive with a range of 10-1500 ng mL(-1) for propofol and 1-QG, 20-3000 ng mL(-1) for PG and 25-3750 ng mL(-1) for 4-QG. The regression curves were linear for all compounds. The method is accurate and precise with intra-assay and inter-assay precision <8% and bias < or =6% for all compounds. This assay has allowed the successful measurement of propofol and its main glucuroconjugate metabolites in human plasma from 24 patients undergoing anaesthesia for elective partial hepatectomy surgery.  相似文献   

15.
A sensitive and specific method using reversed-phase liquid chromatography coupled with electrospray ionization-mass spectrometry (LC-ESI-MS) has been developed for the quantitative determination of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DMF) and 3-hydroxyflunitrazepam (3-OHF) in biological fluids. After the addition of deuterium labelled standards of F,7-AF and N-DMF, the drugs were isolated from urine or plasma by automated solid-phase extraction, then chromatographed in an isocratic elution mode with a salt-free eluent. The quantification was performed using selected ion monitoring of protonated molecular ions (M+H(+)). Experiments were carried out to improve the extraction recovery (81-100%) and the sensitivity (limit of detection 0.025 ng/ml for F and 7-AF, 0.040 ng/ml for N-DMF and 0.200 ng/ml for 3-OHF). The method was applied to the determination of F and metabolites in drug addicts including withdrawal urine samples and in one date-rape plasma and urine sample.  相似文献   

16.
A chemiluminescent assay for hepatitis-B surface antigen is described which used an isoluminol derivative as the label. The assay is precise intra-assay CV, 1.96-2.45%; inter-assay CV, 5.26-8.11% and has a lower detection limit for hepatitis-B surface antigen of 1.3U/I.  相似文献   

17.
A simple, sensitive, selective, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of lorazepam (LZP) in human plasma, using oxazepam (OZP) as internal standard. LZP and OZP were extracted from alkalinized (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with a mixture of n-hexane-dichloromethane (70:30%; v/v). Chromatographic separation was performed on a reversed-phase Synergi Max RP analytical column (150 mmx4.6 mm i.d.; 4 microm particle size), using an aqueous mobile phase (10 mM KH2PO4 buffer (pH 2.4)-acetonitrile; 65:35%, v/v) delivered at a flow-rate of 2.5 ml/min. Retention times for OZP and LZP were 10.2 and 11.9 min, respectively. Calibration curves were linear from 10 to 300 ng with correlation coefficients (r2) better than 0.99. The limits of detection (LOD) and quantification (LOQ) were 2.5 and 10 ng/ml, respectively, using 0.5 ml samples. The mean relative recoveries at 20 and 300 ng/ml were 84.1+/-5.5% (n=6) and 72.4+/-5.9% (n=7), respectively; for OZP at 200 ng the value was 68.2+/-6.8% (n=14). The intra-assay relative standard deviations (R.S.D.) at 20, 150 and 270 ng/ml of LZP were 7.8%, 9.8% (n=7 in all cases) and 6.6% (n=8), respectively. The inter-assay R.S.D. at the above concentrations were 15.9%, 7.7% and 8.4% (n=7 in all cases), respectively. Intra- and inter-assay accuracy data were within the acceptance interval of +/-20% of the nominal values. There was no interference from other commonly co-administered anticonvulsant, antimicrobial, antipyretic, and antimalarial drugs. The method has been successfully applied to a pharmacokinetic study of LZP in children with severe malaria and convulsions following administration of a single intravenous dose (0.1 mg/kg body weight) of LZP.  相似文献   

18.
High-performance liquid chromatography has become an important analytical tool for the quantitation of opioid drugs. Using solid-phase extraction and coulometric electrochemical detection, we have developed a chromatographic method for the simultaneous measurement of morphine and hydromorphone which is both sensitive and specific. Using 1 ml of plasma, intra-assay and inter-assay data show that the detection limit for accurate quantitation of these compounds is about 1.2 ng/ml (coefficient of variation 11.6%) for morphine and 2.5 ng/ml (coefficient of variation 10.5%) for hydromorphone. The method is simple and readily adaptable to most pharmacokinetic studies and toxic screens involving these drugs.  相似文献   

19.
A high performance liquid chromatography (HPLC) method for the estimation of pravastatin in human plasma and urine samples has been developed. The preparation of the samples was performed by automated solid phase extraction using clonazepam as internal standard. The compounds were separated by isocratic reversed-phase HPLC (C(18)) and detected at 239 nm. The method was linear up to concentrations of 200 ng/ml in plasma and 2000 ng/ml in urine. The intra-assay variability for pravastatin in plasma ranged from 0.9% to 3.5% and from 2.5% to 5.3% in urine. The inter-assay variability ranged from 9.1% to 10.2% in plasma and from 3.9% to 7.5% in urine. The validated limits of quantification were 1.9 ng/ml for plasma and 125 ng/ml for urine estimation. These method characteristics allowed the determination of the pharmacokinetic parameters of pravastatin after administration of therapeutic doses.  相似文献   

20.
As the epidemiological and physiological investigation of isoflavones and lignans expands, the need for sensitive methods for analyzing large numbers of samples intensifies. We have developed a method using high-performance liquid chromatography (HPLC) equipped with a coulometric electrode array detector for separation and sensitive detection of daidzein (Da), equol (Eq), genistein (Ge) and enterolactone (Enl) in dried blood spots (DBS). Detection limits ranged from 4.5 pg or 0.09 ng/mL (Eq) to 19 pg or 0.38 ng/mL (Ge) on column. Signal linearities ranged from detection limits to 200 ng/mL (Eq, Enl) and 600 ng/mL (Da, Ge) sample concentration. Correlations between DBS and serum concentrations were 0.66 (Enl), 0.88 (Eq), 0.98 (Ge) and 0.99 (Da). Intra-assay coefficients of variation (CVs) were less than 8% and inter-assay CVs ranged from 2.4 to 20.2% for Da, Eq and Ge for three levels of controls. Enl intra-assay CV was 13.6% for the low pooled control. Analytic recovery ranged from 87% (inter-assay Ge) to 98% (inter-assay Enl). DBS concentrations of Da, Ge and Eq were stable for at least 8 weeks at 4 and 25 degrees C, and at 37 degrees C for at least 5 weeks, with Enl showing greater variability at all temperatures but relative stability for 7 weeks. Measurement of samples from 135 perimenopausal Japanese women consuming habitual diets in Kyoto and Fukushima prefectures showed the former to have the expected lower concentrations of Da and Eq (416 and 87 nM) as well as Enl (49 nM) compared to the latter locale (566, 145 and 72 nM, respectively). This method could be useful in large epidemiological research or detailed physiological studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号