首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.

Background  

The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation.  相似文献   

2.

Introduction  

The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that the vascular geometry created by an implanted stent causes local alterations in wall shear stress (WSS) that are associated with neointimal hyperplasia (NH). Foreshortening is a potential limitation of stent design that may affect stent performance and the rate of restenosis. The angle created between axially aligned stent struts and the principal direction of blood flow varies with the degree to which the stent foreshortens after implantation.  相似文献   

3.

Background  

In-stent restenosis rates have been closely linked to the wall shear stress distribution within a stented arterial segment, which in turn is a function of stent design. Unfortunately, evaluation of hemodynamic performance can only be evaluated with long term clinical trials. In this work we introduce a set of metrics, based on statistical moments, that can be used to evaluate the hemodynamic performance of a stent in a standardized way. They are presented in the context of a 2D flow study, which analyzes the impact of different strut profiles on the wall shear stress distribution for stented coronary arteries.  相似文献   

4.

Background

The introduction of drug-eluting stents (DES) has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP) has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC), endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.

Methods

Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.

Results

Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.

Conclusion

We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.  相似文献   

5.

Background  

Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed.  相似文献   

6.

Purpose

While animal models are widely used to investigate the development of restenosis in blood vessels following an intervention, computational models offer another means for investigating this phenomenon. A computational model of the response of a treated vessel would allow investigators to assess the effects of altering certain vessel- and stent-related variables. The authors aimed to develop a novel computational model of restenosis development following an angioplasty and bare-metal stent implantation in an atherosclerotic vessel using agent-based modeling techniques. The presented model is intended to demonstrate the body’s response to the intervention and to explore how different vessel geometries or stent arrangements may affect restenosis development.

Methods

The model was created on a two-dimensional grid space. It utilizes the post-procedural vessel lumen diameter and stent information as its input parameters. The simulation starting point of the model is an atherosclerotic vessel after an angioplasty and stent implantation procedure. The model subsequently generates the final lumen diameter, percent change in lumen cross-sectional area, time to lumen diameter stabilization, and local concentrations of inflammatory cytokines upon simulation completion. Simulation results were directly compared with the results from serial imaging studies and cytokine levels studies in atherosclerotic patients from the relevant literature.

Results

The final lumen diameter results were all within one standard deviation of the mean lumen diameters reported in the comparison studies. The overlapping-stent simulations yielded results that matched published trends. The cytokine levels remained within the range of physiological levels throughout the simulations.

Conclusion

We developed a novel computational model that successfully simulated the development of restenosis in a blood vessel following an angioplasty and bare-metal stent deployment based on the characteristics of the vessel cross-section and stent. A further development of this model could ultimately be used as a predictive tool to depict patient outcomes and inform treatment options.  相似文献   

7.

Background

Percutaneous coronary intervention (PCI) stent inflation pressure correlates to angiographic lumen improvement and stent expansion but the relation to outcome is not clarified. Using comprehensive registry data our aim was to evaluate how stent inflation pressure influences restenosis, stent thrombosis and death following PCI.

Methods

We evaluated all consecutive coronary stent implantations in Sweden during 46 months from 2008 using data from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). We used logistic regression and Cox proportional hazard modeling to estimate risk of outcomes with different balloon pressures.

Results

In total, 93 697 stents were eligible for analysis and divided into five different pressure interval groups: ≤15 atm, 16–17 atm, 18–19 atm, 20–21 atm and ≥22 atm. The risks of stent thrombosis and restenosis were significantly higher in the ≤15 atm, 18–19 atm and ≥22 atm groups (but not in the 16–17 atm group) compared to the 20–21 atm group. There were no differences in mortality. Post-dilatation was associated with a higher restenosis risk ratio (RR) of 1.22 (95% confidence interval (CI) 1.14–1.32, P<0.001) but stent thrombosis did not differ statistically between procedures with or without post-dilatation. The risk of death was lower following post-dilatation (RR 0.81 (CI 0.71–0.93) P = 0.003) and the difference compared to no post-dilatation was seen immediately after PCI.

Conclusion

Our retrospective study of stent inflation pressure identified a possible biological pattern—the risks of stent thrombosis and of restenosis appeared to be higher with low and very high pressures. Post-dilatation might increase restenosis risk.  相似文献   

8.
9.

Background

Nuclear factor‐kappa B (NF‐κB) is well known for playing a pivotal role in restenosis after percutaneous coronary intervention (PCI).

Methods and Results

This is the first report to demonstrate an effect of NF‐κB decoy oligodeoxynucleotides (ODN) to prevent restenosis after PCI after a 4‐year observation using a coronary computed tomography (CT) scan. We showed that the decoy treatment suppressed neointimal formation after stent implantation compared to that in the same artery.

Conclusion

Thus, for the first time, we demonstrate the clinical usefulness of the CT scan to reveal the effects of NF‐κB decoy ODN transfer after PCI. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.

Background  

Strictly intravascular approaches for the treatment of postangioplasty restenosis are effective in the intima and the inner parts of the media but may be insufficient to control redundant pathways in the more outer parts of the media and the adventitia. An inverse situation may occur subsequently to a strictly extravascular approach, like the recently suggested pericardial approach in pigs. We hypothesized that simultaneous intra/extravascular administration of anti-restenotic agents inhibits restenosis by blocking all stimulatory pathways in the entire arterial wall.  相似文献   

11.

Background

Patients with diabetes mellitus (DM) have an increased risk for periprocedural complications and adverse cardiac events after percutaneous coronary intervention. We addressed the potential for coronary microvascular obstruction and restenosis in patients with and without DM undergoing stenting for saphenous vein bypass graft (SVG) stenosis under protection with a distal occlusion/aspiration device.

Methods

SVG plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Percent diameter stenosis was determined from quantitative coronary angiography before, immediately after and 6?months after stent implantation. Coronary aspirate was retrieved during stent implantation and divided into particulate debris and plasma. Total calcium, several vasoconstrictors, and tumor necrosis factor (TNF)α in particulate debris and coronary aspirate plasma were determined.

Results

Patients with and without DM had similar plaque volume, but larger necrotic core and greater particulate debris release in patients with than without DM (20.3±2.7 vs. 12.7±2.6% and 143.9±19.3 vs. 75.1±10.4?mg, P<0.05). The TNFα concentration in particulate debris and coronary aspirate plasma was higher in patients with than without DM (15.9±6.6 vs. 5.1±2.4 pmol/mg and 2.2±0.7 vs. 1.1±0.2 pmol/L, P<0.05), whereas total calcium and vasoconstrictors were not different. Patients with DM had a greater percent diameter stenosis 6?months after stent implantation than those without DM (22.17±5.22 vs. 6.34±1.11%, P<0.05). The increase in TNFα immediately after stent implantation correlated with restenosis 6?months later (r=0.69, P<0.05).

Conclusion

In diabetics, particulate debris and coronary aspirate plasma contained more TNFα, which might reflect the activity of the underlying atherosclerotic process.

Trial registration

URL: http://www.clinicaltrials.gov/ct2/results?term=NCT01430884; unique identifier: NCT01430884  相似文献   

12.

Background  

A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent.  相似文献   

13.
A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence the restenosis process. The present three-dimensional analysis of developing pulsatile flow in a deployed coronary stent quantifies hemodynamic parameters and illustrates the changes in local wall shear stress distributions and their impact on restenosis. The present model evaluates the effect of entrance flow, where the stent is placed at the entrance region of a branched coronary artery. Stent geometry showed a complex three-dimensional variation of wall shear stress distributions within the stented region. Higher order of magnitude of wall shear stress of 530 dyn/cm2 is observed on the surface of cross-link intersections at the entrance of the stent. A low positive wall shear stress of 10 dyn/cm2 and a negative wall shear stress of -10 dyn/cm2 are seen at the immediate upstream and downstream regions of strut intersections, respectively. Modified oscillatory shear index is calculated which showed persistent recirculation at the downstream region of each strut intersection. The portions of the vessel where there is low and negative wall shear stress may represent locations of thrombus formation and platelet accumulation. The present results indicate that the immediate downstream regions of strut intersections are areas highly susceptible to restenosis, whereas a high shear stress at the strut intersection may cause platelet activation and free emboli formation.  相似文献   

14.

Background  

Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose.  相似文献   

15.

Background

Stent length serves as a predictor of restenosis in use of bare metal stents (BMS). This has been demonstrated in a feasibility study that used a single short BMS implant (<9 mm) in a high proportion of lesions; the study observed a low rate of restenosis.

Methods

We performed a pilot prospective study to investigate in a series of consecutive patients the immediate and long-term effects of implantation of either 1) a single short BMS for all lesions with low probability of restenosis or 2) a drug-eluting stent (DES) for all other lesions.

Results

The 200 patients studied had 236 coronary artery lesions that were treated with short BMS in 168/236 patients (71.2%) and with DES in 68/236 patients (28.8%). Angiographic success was achieved in 230/236 lesions (97.5%) and procedural success in 194/200 patients (97.0%). Restenosis occurred in 15/153 lesions (9.8%) after short BMS, in 3/62 lesions (4.8%) after DES, and in 18/215 of all lesions (8.4%) angiographically controlled after six to eight months. Target vessel revascularization was performed in 16/218 lesion (7.4%).

Conclusion

Most of the coronary artery lesions in this small group of consecutive patients were treated sufficiently with a single BMS implant. This differential approach of treating suitable lesions in medium- to large-sized vessels with a single short BMS device and treating all other lesions with a DES implant resulted in a low incidence of restenosis.  相似文献   

16.

Background

Stent length serves as a predictor of restenosis in use of bare metal stents (BMS). This has been demonstrated in a feasibility study that used a single short BMS implant (<9 mm) in a high proportion of lesions; the study observed a low rate of restenosis.

Methods

We performed a pilot prospective study to investigate in a series of consecutive patients the immediate and long-term effects of implantation of either 1) a single short BMS for all lesions with low probability of restenosis or 2) a drug-eluting stent (DES) for all other lesions.

Results

The 200 patients studied had 236 coronary artery lesions that were treated with short BMS in 168/236 patients (71.2%) and with DES in 68/236 patients (28.8%). Angiographic success was achieved in 230/236 lesions (97.5%) and procedural success in 194/200 patients (97.0%). Restenosis occurred in 15/153 lesions (9.8%) after short BMS, in 3/62 lesions (4.8%) after DES, and in 18/215 of all lesions (8.4%) angiographically controlled after six to eight months. Target vessel revascularization was performed in 16/218 lesion (7.4%).

Conclusion

Most of the coronary artery lesions in this small group of consecutive patients were treated sufficiently with a single BMS implant. This differential approach of treating suitable lesions in medium- to large-sized vessels with a single short BMS device and treating all other lesions with a DES implant resulted in a low incidence of restenosis.  相似文献   

17.

Background

A stent in a false lumen is a common cause of stent occlusion after coronary percutaneous coronary artery intervention therapy, particularly in the culprit lesion of acute myocardial infarction. Here, we present an unusual case of successful recanalization of the proximal right coronary artery with implementation of another stent to crush the previous stent in the false lumen.

Case presentation

A 40-year-old Chinese man underwent coronary stent implementation in the proximal right coronary artery due to acute inferior wall myocardial infarction at another hospital. Six months later, he underwent coronary angiography re-examination for recurrent symptomatic angina at our hospital. Coronary angiography and intravascular ultrasound confirmed that the previous stent was deployed in the false lumen of the right coronary artery. Then, intravascular ultrasound was used to guide the wire to re-enter the true lumen of the proximal right coronary artery, and another stent was deployed into the true lumen to crush the previous stent.

Conclusion

Intravascular ultrasound proved to be a pivotal tool in confirming false or true lumen, as well as determining favorable proximal site entry points to avoid rewiring the mesh of the previous stent.
  相似文献   

18.
The patho-physiologic process of restenosis and tissue growth may not be completely eliminated and is the primary concern of clinicians performing angioplasty and stent implantation procedures. Recent evidence suggests that the restenosis process is influenced by several factors: (1) geometry and size of vessel; (2) stent design; and (3) it's location that alter hemodynamic parameters, including local wall shear stress (WSS) distributions. The present three-dimensional (3D) analysis of pulsatile flow in a deployed coronary stent: (1) shows complex 3D variation of hemodynamic parameters; and (2) quantifies the changes in local WSS distributions for developed flow and compares with recently published WSS data for developing flow. Higher order of magnitude of WSS of 290 dyn/cm(2) is observed on the surface of cross-link intersections at the entrance of the stent for developed flow, which is about half of that for developing flow. Low WSS of 0.8 dyn/cm(2) and negative WSS of -8 dyn/cm(2) are seen at the immediate upstream and downstream regions of strut intersections. Persistent recirculation is observed at the downstream region of each strut cross-link and the regions of low and negative WSS may lead to patho-physiologic conditions near the stented region. The key finding of this study is that the location of stent in the coronary artery determines the developing or developed nature of the flow, which in turn, results in varied level of WSS.  相似文献   

19.

Background

Metallic large Y stent placement has been used mainly for airway disease around the main carina. However, few studies have reported this treatment for bronchial disease around the primary right carina.

Methods

Twenty-eight patients were treated by small y stent. All stents were custom-designed and placed under fluoroscopic guidance. Clinical and imaging data were analyzed retrospectively.

Results

Thirty-one stents were successfully inserted in 28 patients. Twenty-five patients succeed at the first attempt (89.3%), and 3 patients needed a second attempt. Twelve complications occurred in 10 patients (35.7%). Stent restenosis and sputum retention were the most common complications. Five patients underwent successful stent removal due to complications or cure efficacy. During follow up, 17 patients died of tumors and one died of myocardial infarction. The 1-, 3-, and 5-year survival rates were 49.3, 19.6 and 19.6%, respectively.

Conclusions

Metallic small y stent placement is technically feasible, effective and safe for bronchial disease around the primary right carina.
  相似文献   

20.
The reduction in plaque volume during stent implantation is associated with the release of particulate debris and plaque-derived soluble substances. We studied the potential release of the proinflammatory cytokine TNF-alpha into the coronary circulation and whether such release is related to the reduction in plaque volume and, possibly, a predictor for restenosis. In 18 male patients (n = 24 stents) with severe stenosis in a saphenous vein aortocoronary bypass graft (SVG), we used a distal balloon occlusion-aspiration device during stent implantation. The aspirate TNF-alpha levels were determined before and after stent implantation and related to the angiographic and intravascular ultrasound-assessed severity of stenosis and restenosis. We found that TNF-alpha is, indeed, released into the aspirate of stented SVG (9 +/- 1 and 28 +/- 3 pg/ml before and after stent implantation, respectively, P < 0.0001) and that such release is related to the reduction in plaque volume (r = 0.88, P < 0.0001) and associated with restenosis after 5 mo (r = 0.71, P = 0.001). The periprocedural release of plaque-derived TNF-alpha possibly represents the amount and activity of the atherosclerotic process and might be a predictor for restenosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏