首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
A simple, rapid, sensitive and specific ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the quantification of ethosuximide in human plasma is described. Analyte was chromatographed on a Hypersil Gold C18 column (100 mm × 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow rate of 0.250 mL/min and pravastatin was used as the internal standard. The assay involves a simple solid-phase extraction procedure of 0.25 mL human plasma and the analysis was performed on a triple-quadrupole tandem mass spectrometer by MRM mode via electrospray ionization (ESI). The method was linear in the concentration range of 0.25–60.0 μg/mL. The lower limit of quantification (LLOQ) was 0.25 μg/mL. The within- and between-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 95.1% and 94.4% for ethosuximide and pravastatin, respectively. The analysis time for each sample was 1.8 min. The method was highly reproducible and gave peaks with excellent chromatography properties.  相似文献   

3.
Amphetamines are a group of sympathomimetic drugs that exhibit strong central nervous system stimulant effects. d-Amphetamine ((+)-alpha-methylphenetylamine) is the parent drug in this class to which all others are structurally related. In drug discovery, d-amphetamine is extensively used either for the exploration of novel mechanisms involving the catecholaminergic system, or for the validation of new behavioural animal models. Due to this extensive use of d-amphetamine in drug research and its interest in toxicologic–forensic investigation, a specific and high-throughput method, with minimal sample preparation, is necessary for routine analysis of d-amphetamine in biological samples. We propose here a sensitive, specific and high-throughput bioanalytical method for the quantitative determination of d-amphetamine in rat blood using MS3 scan mode on a hybrid triple quadrupole-linear ion trap mass spectrometer (LC–MS/MS/MS). Blood samples, following dilution with water, were prepared by fully automated protein precipitation with acetonitrile containing an internal standard. The chromatographic separation was achieved on a Waters XTerra C18 column (2.1 mm × 30 mm, 3.5 μm) using gradient elution at a flow rate of 1.0 mL/min over a 2 min run time. An Applied Biosystems API4000 QTRAP™ mass spectrometer equipped with turbo ion-spray ionization source was operated simultaneously in MS3 scan mode for the d-amphetamine and in multiple reaction monitoring (MRM) for the internal standard. The MS/MS/MS ion transition monitored was m/z 136.1 → 119.1 → 91.1 for the quantitation of d-amphetamine and for the internal standard (rolipram) the MS/MS ion transition monitored was m/z 276.1 → 208.2. The linear dynamic range was established over the concentration range 0.5–1000 ng/mL (r2 = 0.9991). The method was rugged and sensitive with a lower limit of quantification (LLOQ) of 0.5 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. This method was successfully applied to evaluate the pharmacokinetics of d-amphetamine in rat. On a more general extent, this work demonstrated that the selectivity of the fragmentation pathway (MS3) can be used as alternative approach to significantly improve detection capability in complex situation (e.g., small molecules in complex matrices) rather than increasing time for sample preparation and chromatographic separation.  相似文献   

4.
Interassay variation of antibody-based routine tests hampers comparability of measurement results for growth hormone (GH) between different laboratories and decision making in clinical practice. Here it is demonstrated that quantification of GH by isotope dilution mass spectrometry (IDMS) constitutes a way to obtain precise and reliable results that can be referred to in evaluation of performance of commercial test kits. With the IDMS method developed, tryptic cleavage products YSFLQNPQTSLCFSESIPTPSNR (T6) and LEDGSPR (T12) of GH are quantified by liquid chromatography tandem mass spectrometry (LC-MS/MS) using isotopically labeled forms of the peptides as internal standards. The GH cleavage fragments are obtained by whole serum tryptic proteolysis and then extracted from the resulting mixture by semipreparative reversed-phase LC followed by strong cation exchange chromatography. Analysis of blank serum spiked with recombinant 22-kDa GH at different concentration levels would result in a mean recovery of 101.6%, a standard deviation (SD) of 2.5%, a combined uncertainty (uc) of 3.0%, and a limit of quantification (LOQ) of 1.7 μg/L when quantifying T6 as a GH-derived fragment, whereas recovery = 100.7%, SD = 2.4%, uc = 2.5%, and LOQ = 2.7 μg/L were found with T12. The potential to acquisition of reference values is exemplified by application to serum materials used in a recent quality assessment exercise for routine laboratories.  相似文献   

5.

Background

Inhaled corticosteroids including fluticasone propionate (FP) are the most effective treatment for persistent-asthma. Noncompliance ranging from 20% to 80% of treated patients is associated with substantial health care costs, morbidity and fatalities. A noninvasive test to assess FP treatment compliance is needed. The major metabolite of FP is FP-17beta-carboxylic acid (FP17βCA) and is excreted in urine. This study demonstrates the development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to measure FP17βCA in urine and evaluation of FP17βCA urinary elimination.

Experimental

Fluorometholone was used as the internal standard. After acetonitrile precipitation, samples were extracted with dichloromethane, washed and dried. Reconstituted extract (60 μL) was subjected to reversed-phase chromatography and positive-ion mode LC-MS/MS analysis. Assay precision, linearity, recovery and sample stability were determined. Elimination evaluation included measurement of FP17βCA in urine collected daily from human subjects before (day 1), during treatment (days 2-5; dose FP-110 μg 2 puffs/day), and following cessation of FP therapy (days 6-14; n = 4).

Results

Linear range of the FP17βCA assay was 10.3-9510 pg/mL. Limit of quantitation (LOQ) was 10.3 pg/mL and recovery ranged from 85.8% to 111.9%. Inter-assay CVs were 7.4-12.0% for FP17βCA concentrations of 11.1-5117 pg/mL. Urine FP17βCA was absent in subjects prior to FP therapy, detectable (180-1991 ng FP17βCA/g creatinine) throughout the dosing period and reached below the LOQ at 6 days after therapy cessation.

Conclusions

Measurement of FP17βCA by LC-MS/MS has acceptable analytical performance for clinical use. These data support the clinical utility of measuring FP17βCA in urine to monitor patient compliance with FP therapy.  相似文献   

6.
This work aims to combine chromatographic retention, high mass resolution and accuracy, MS/MS spectra, and a package for automated identification and quantitation of lipid species in one platform for lipidomic analysis. The instrumental setup elaborated comprises reversed-phase HPLC coupled to a Fourier transform ion cyclotron resonance mass spectrometer (LTQ-FT), and Lipid Data Analyzer (LDA) software. Data analysis for lipid species quantification in this platform is based on retention time, mass resolution of 200,000, and mass accuracy below 2 ppm. In addition, automatically generated MS/MS spectra provide structural information at molecular level. This LC/MS technology allows analyzing complex biological samples in a quantitative manner as shown here paradigmatically for murine lipid droplets having a huge surplus of triacylglycerol species. Chromatographic preseparation of the bulk lipid class alleviates the problem of ion suppression of lipid species from other classes. Extension of 1D to 2D chromatography is possible, yet time consuming. The platform affords unambiguous detection of lipid species as low as 0.1‰ within major lipid classes. Taken together, a novel lipidomic LC/MS platform based on chromatographic retention, high mass resolution and accuracy, MS/MS analysis, and quantitation software enables analysis of complex samples as demonstrated for lipid droplets.  相似文献   

7.
A selective, rapid and sensitive hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC–MS/MS) method was developed for the first time to determine adefovir in human plasma and applied to a pharmacokinetic study. Plasma samples were prepared by protein precipitation with methanol followed by a further cleaning using dichloromethane. The chromatographic separation was carried out on an ACQUITY UPLC™ BEH HILIC column with the mobile phase of methanol–water–formic acid (85:15:0.2, v/v/v). The detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The method was rapid with a run time of 3 min per sample. The linear calibration curves were obtained in the concentration range of 1.02–102 ng/mL (r2 ≥ 0.99) with the lower limit of quantification (LLOQ) of 1.02 ng/mL. The intra- and inter-day precision (relative standard deviation, R.S.D.) values were below 12% and the accuracy (relative error, R.E.) was from 0.6% to 3.2% at all quality control (QC) levels. The method was applicable to clinical pharmacokinetic study of adefovir in healthy volunteers after oral administration of adefovir dipivoxil tablet.  相似文献   

8.
A sensitive, selective and high throughput liquid chromatography tandem mass spectrometry (LC–ESI-MS/MS) method has been developed for the determination of teriflunomide, an active metabolite of leflunomide in human plasma. Plasma samples were prepared by liquid–liquid extraction of teriflunomide and valsartan as internal standard (IS) in ethyl acetate from 200 μL human plasma. The chromatographic separation was achieved on an Inertsil ODS-3 C18 (50 mm × 4.6 mm, 3 μm) analytical column using isocratic mobile phase, consisting of 20 mM ammonium acetate–methanol (25:75, v/v), at a flow-rate of 0.8 mL/min. The precursor → product ion transition for teriflunomide (m/z 269.0 → 82.0) and IS (m/z 434.1 → 350.3) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and negative ion mode. The method was validated over a wide dynamic concentration range of 10.1–4001 ng/mL. Matrix effect was assessed by post-column infusion experiment and the mean process efficiency were 91.7% and 88.2% for teriflunomide and IS respectively. The method was rugged and rapid with a total run time of 2.0 min and is applied to a bioequivalence study of 20 mg leflunomide (test and reference) tablet formulation in 12 healthy Indian male subjects under fasting condition.  相似文献   

9.
A simple offline LC–MS/MS method for the quantification of sitagliptin in human plasma is described. Samples are prepared using protein precipitation. Filtration of the supernatants through a Hybrid-SPE-PPT plate was found to be necessary to reduce ionization suppression caused by co-elution of phospholipids with sitagliptin. The sitagliptin and its stable isotope labeled internal standard (IS) were chromatographed under hydrophilic interaction chromatography conditions on a Waters Atlantis HILIC Silica column (2.1 mm × 50 mm, 3 μm) using a mobile phase of ACN/H2O (80/20, v/v) containing 10 mM NH4Ac (pH 4.7). The sample drying after protein precipitation due to high organic content in the sample is not necessary, because HILIC column was used. The analytes were detected with a tandem mass spectrometer employing a turbo ion spray (TIS) interface in positive ionization mode. The multiple reaction monitoring (MRM) transitions were m/z 408 → 235 for sitagliptin and m/z 412 → 239 for IS. The lower limit of quantitation (LLOQ) for this method is 1 ng/mL when 100 μL of plasma is processed. The linear calibration range is 1–1000 ng/mL for sitagliptin. Intra-day precision and accuracy were assessed based on the analysis of six sets of calibration standards prepared in six lots of human control plasma. Intra-day precision (RSD%, n = 6) ranged from 1.2% to 6.1% and the intra-day accuracy ranged from 97.6% to 103% of nominal values.  相似文献   

10.
Two-dimensional liquid chromatography (2D-LC) coupled on-line with electrospray ionization tandem mass spectrometry (2D-LC-ESI-MS/MS) is a new platform for analysis and identification of proteome. Peptides are separated by 2D-LC and then performed MS/MS analysis by tandem MS/MS. The MS/MS data are searched against database for protein identification. In one 2D-LC-ESI-MS/MS run, we obtained not only the structural information of peptides directly from MS/MS, but also the retention time of peptides eluted from LC. Information on the chromatographic behavior of peptides can assist protein identification in the new platform for proteomics. The retention time of the matching peptides of the identified protein was predicted by the hydrophobic contribute of each amino acid on reversed-phase liquid chromatography (RPLC). By using this strategy proteins were identified by four types of information: peptide mass fingerprinting (PMF), sequence query, and MS/MS ions searched and the predicted retention time. This additional information obtained from LC could assist protein identification with no extra experimental cost.  相似文献   

11.
A rapid, sensitive and simple high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed for determination of cefazedone in human plasma using metronidazole as internal standard (IS). The chromatographic separation was achieved on an Ultimate XB-CN column (2.1 mm × 150 mm, 5 μm) with an isocratic mobile phase of acetonitrile and 20 mM ammonium acetate in 0.1% formic acid in water (15:85, v/v). Detection was performed using electrospray ionization in positive ion multiple reaction-monitoring mode (SRM), monitoring the transitions m/z 548.2 → 344.1 for cefazedone and m/z 172.2 → 128.1 for IS. Calibration curves were linear over a wide range of 0.20–401.12 μg/mL for cefazedone in plasma. The lower limit of quantification (LLOQ) was 0.20 μg/mL. The intra- and inter-day precisions were less than 7.2%. The average recovery of cefazedone was 90.8–91.0%. The validated method was successfully applied to the pharmacokinetic study of cefazedone in Chinese healthy volunteers following intravenous (IV) administration of 500, 1000 and 2000 mg cefazedone injection.  相似文献   

12.
A sensitive liquid chromatography–tandem mass spectrometry method for the simultaneous determination of triclabendazole, its main metabolites (triclabendazole sulphone and triclabendazole sulphoxide) and a marker residue (ketotriclabendazole) in bovine and goat muscle, liver, and kidney samples is developed and validated. Analyte extraction from samples is effectively performed using liquid–liquid extraction by acetonitrile. Chromatographic separation is performed on a C18 reversed-phase column with gradient elution. The analytes are detected by tandem quadrupole mass spectrometry after positive electrospray ionization by multiple reaction monitoring. The limits of detection for analytes are found to be 0.25–2.5 μg/kg in muscle tissues and 1–10 μg/kg in liver and kidney tissues, respectively. The recoveries of edible bovine and goat tissues range from 84.9% to 109.5% when spiked at different levels with analytes, with relative standard deviations generally below 12.8%.  相似文献   

13.
Wael A. Salameh 《Steroids》2010,75(2):169-175
Accurate measurement of testosterone concentration is of critical importance when diagnosing and treating male hypogonadism, congenital adrenal hyperplasia, premature or delayed puberty, and androgen excess in polycystic ovary syndrome or other virilizing conditions. However, some assays have inherent limitations and biases that affect measurement of low-testosterone values. Therefore, we developed a highly specific online mass spectrometry method. Sera were extracted online using high-turbulence flow liquid chromatography coupled to analytical HPLC and atmospheric pressure chemical ionization tandem mass spectrometry (HTLC-APCI-MS/MS). Analyte ions were monitored by multiple reaction monitoring (MRM). Total analysis time was 1.15 min per sample when using the multiplexing system. Testosterone concentrations were measured directly from 150 μL of serum or plasma without derivatization or liquid-liquid extraction. The lower limit of quantification was 0.3 ng/dL, and the assay was linear up to 2000 ng/dL. The method compared very well with an established RIA: y = 1.02x + 1.5, r2 = 0.994. Comparison with a platform immunoassay confirmed the previously reported ICMA positive bias at low concentrations. Male and female adult and pediatric reference ranges were developed for this very sensitive and accurate high-throughput LC-MS/MS method. This method is suitable for measuring the expected low-testosterone concentrations seen in women, children, and hypogonadal males and for monitoring testosterone suppressive therapy in prostate cancer patients.  相似文献   

14.
We performed prenatal diagnosis of organic acid disorders using two mass spectrometric methods; gas chromatography mass spectrometry (GC/MS) and tandem mass spectrometry (ESI/MS/MS). Of 28 cases whose amniotic fluid was tested, 11 cases were diagnosed as "affected". All cases whose samples were diagnosed as "unaffected" were confirmed to have no symptoms or abnormalities in urinary organic acid analysis after birth. Of the 11 "affected" cases, two cases were missed by ESI/MS/MS but not by GC/MS. When the stability of metabolites in amniotic fluid was checked, it was found that acylcarnitines degraded in one week at room temperature, whereas organic acids such as methylmalonate or methylcitrate were stable for at least 14 days. Prenatal diagnosis by analysis using simultaneous two or more methods may be more reliable, though attention should be paid to sample transportation conditions.  相似文献   

15.
Quantification of oligosaccharides is of great importance to investigate variations or changes in the glycans of glycoconjugates. Mass spectrometry (MS) has been widely applied to identification and structural analysis of complex oligosaccharides. However, quantification using MS alone is still quite challenging due to heterogeneous charge states and different ionization efficiency of various types of oligosaccharides. To overcome such shortcomings, derivatization with carboxymethyl trimethylammonium hydrazide (Girard’s reagent T [GT]) was introduced to generate a permanent cationic charge at the reducing end of neutral oligosaccharides, resulting in mainly [M]+ ion using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), so that the ambiguities caused by metal adduct peaks such as [M+K]+ and [M + Na]+ were avoided. To verify our method, the relative and absolute quantification of neutral glycans from human immunoglobulin G (IgG) and ovalbumin with internal standards of dextran ladders using MALDI-TOF MS were compared with those performed by conventional normal-phase high-performance liquid chromatography (NP-HPLC) profiling. The quantification using GT derivatization and MALDI-TOF MS agreed well with the HPLC profiling data and showed excellent reliability and reproducibility with better resolution and sensitivity. This method was further applied to quantify the enzymatically desialylated N-glycans from miniature pig kidney membrane proteins. The results showed that the low-abundance structures that could not be resolved by NP-HPLC were quantified with high sensitivity. Thus, this novel method of using modification of neutral sugars with GT is quite powerful for neutral glycan analysis, especially to quantify minute glycan samples with undetectable levels using HPLC.  相似文献   

16.
A simple and rapid method for the identification of Vinca alkaloids from a crude extract of Catharanthus roseus G. Don (Apocynaceae) by direct-injection electrospray ionisation (ESI) and tandem mass spectrometry (MS/MS) has been developed. The alkaloids vindoline, vindolidine, vincristine and vinblastine were evaluated in a commercial extract of C. roseus using this method. Catharanthine and its isomers 19S-vindolinine and vindolinine were detected in the commercial product by direct injection ESI/MS/MS and confirmed by preparation and by HPLC-ESI/MS. For the characterisation of different fragment fingerprints, ESI/MS/MS is a sensitive, rapid and convenient technique by which to identify some constituents in complex and mixed plant extracts.  相似文献   

17.
Liquid chromatography–mass spectrometry (LC–MS) is a highly sensitive tool for the analysis of polyphenolic compounds in complex food and beverage matrices. However, the high degree of isomerism among polyphenols in general often complicates this approach, especially for identification of novel compounds. Here, we explore the utility of mild acid-catalyzed deuterium (MACD) labeling via electrophilic aromatic substitution as a complementary method for informing polyphenolic compound structure elucidation. To prevent hydrolysis of acid-labile glycosidic linkages, optimal reaction conditions that maximize regioselective hydrogen/deuterium (H/D) exchange of aromatic protons while preserving compound integrity were characterized (60 °C, pH 3.0, 72 h). Under these conditions, standard compounds varying in the number and position of hydroxyl, glycosyl, and methyl groups about their aromatic core structure produced distinguishable H/D exchange patterns. The applicability of this method for the analysis of complex mixtures was demonstrated in red wine where the extent of deuterium exchange, together with accurate mass information, led to the putative identification of an unknown compound. The identification was further supported by tandem MS (MS/MS) data, which matched conclusively to the same compound in the Metlin LC–MS/MS library. With the capacity to discriminate between select isomeric forms, MACD labeling provides structural information that complements accurate mass and tandem mass spectral measurements for informing the identification of polyphenolics by MS.  相似文献   

18.
Pertussis toxoid, an acellular pertussis vaccine prepared by hydrogen peroxide treatment in the presence of Fe3+, has not been well characterized. Because the toxoid has been a part of the DTaP vaccine for infants, it is of interest and significance to have a clear understanding of its structure. The five subunits of pertussis toxin (PT) have a combined molecular weight of approximately 95,000 Da. The peroxide treatment in toxoid formation introduces additional complexity into the protein sequence. To maximize sequence coverage, a two-dimensional liquid chromatography-tandem mass spectrometry (2D LC-MS/MS) approach was used to analyze the tryptic digest of toxoid as a whole. An analytical-scale high-performance liquid chromatography (HPLC) instrument using a pentafluorophenyl (PFP) column was used as the first-dimensional LC for fraction collection. The fractions were then analyzed by nanoLC-MS/MS using a C18 column to acquire collision-activated dissociation (CAD) spectra of the tryptic peptides. It is shown that a PFP column has a different peptide retention specificity from a C18 column. A combination of a PFP column and a C18 column is a viable approach for dispersing peptides in a complex mixture. From the structures of 65 peptides that represented approximately 50% of its sequence, PT was found to have sustained heavy oxidative damages during toxoid preparation. Nearly all methionine, cysteine, and (likely) tryptophan residues were oxidized. Evidence of histidine and tyrosine oxidation was also observed. In addition, a large percentage of asparagine was found hydrolyzed to aspartic acid. These findings corrrelate well with the reduction of PT toxicity by peroxide treatment.  相似文献   

19.
Here we report a new method for oxosteroid identification utilizing “tandem mass tag hydrazine” (TMTH) carbonyl-reactive derivatisation reagent. TMTH is a reagent with a chargeable tertiary amino group attached through a linker to a carbonyl-reactive hydrazine group. Thirty oxosteroids were analysed after derivatisation with TMTH by electrospray ionization mass spectrometry (ESI-MS) and were found to give high ion-currents compared to underivatised molecules. ESI-tandem mass spectrometry (MS/MS) analysis of the derivatives yielded characteristic fragmentation patterns with specific mass reporter ions derived from the TMT group. A shotgun ESI-MS method incorporating TMTH derivatisation was applied to a urine sample.  相似文献   

20.

Background

Though mass spectrometry (MS) assays are increasingly used for routine clinical measurements of serum total testosterone (TT), information about the variability of results is limited. This study assessed the variability of TT measurement results from routine MS assays.

Methods

Twenty serum samples (12 females, 8 males) were analyzed on 2 days by seven high performance liquid chromatography (HPLC), and one gas chromatography (GC)-tandem mass spectrometry (HPLC-MS/MS, GC-MS/MS) assays. Two samples (male and female) were provided in five replicates to assess the within-run variability. Results were compared against those obtained at National Institute of Standards and Technology (NIST). The within- and between-laboratory variability was assessed for each sample. Comparisons to the NIST results were performed using bias plot and Deming regression analysis.

Results

The overall coefficient of variation of the results obtained with MS assays was <15%CV at >1.53 nmol/L and <34%CV at 0.3 nmol/L. The between-assay variability was the major contributor to the overall variability. The assay precision was the highest (<3%CV) with assays using liquid-liquid extraction for sample preparation or GC-MS/MS. The mean percent difference to the reference assay was 11%. The slopes of Deming regression analysis of the MS assays were between 0.903 and 1.138 (correlation coefficient: >0.996). TT concentrations for one assay were above the measurement range.

Conclusions

The variability of TT measurement results among MS assays is substantially smaller than that reported for immunoassays. The type of sample preparation may affect assay precision. Standardizing assays can further reduce the variability of measurement results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号