首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 205 毫秒
1.
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma.  相似文献   

2.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

3.
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.  相似文献   

4.
An HPLC/MS/MS method for determination of butenafine hydrochloride in human plasma with testosterone propionate as the internal standard (IS) was developed and validated. Plasma samples were extracted with an n-hexane/diethyl ether (1:2, v/v) mixture and separated using a C(18) column by a gradient elution with the mobile phase containing acetonitrile and 5mM ammonium acetate buffer. Quantification was performed using multiple reaction monitoring (MRM) mode with transition of m/z 318.4→141.0 for butenafine hydrochloride and m/z 345.5→97.0 for testosterone propionate (IS). This method was validated in terms of specificity, linearity, precision, accuracy, and stability. The lower limit of quantification (LLOQ) of this method was 0.0182 ng/ml and the calibration curve was linear over the 0.0182-1.82 ng/ml. The intra- and inter-run coefficient of variance was less than 11.53% and 10.07%, respectively. The samples were stable under all the tested conditions. The method was successfully applied to study the pharmacokinetics of butenafine hydrochloride in healthy Chinese volunteers following its topical administration.  相似文献   

5.
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers.  相似文献   

6.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

7.
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of memantine (I) in human plasma is presented. Sample preparation consisted of the addition of amantadine (II) as internal standard (IS), liquid-liquid extraction in basic conditions using a mixture of diethyl ether-chloroform (7:3, v/v) as extracting solvent, followed by centrifugation, solvent evaporation and sample reconstitution in methanol. Both I and II (internal standard) were analyzed using a C18 column and a mobile phase composed of methanol-water-formic acid (80:20:0.1, v/v/v). Eluted compounds were monitored using positive mode electrospray (ES) tandem mass spectrometry. The analyses were carried out by selected reaction monitoring (SRM) using the parent to daughter combinations of m/z 180>163 (memantine) and m/z 152>135 (amantadine). The peak areas from the analyte and IS were used for quantification of I. The achieved limit of quantification (LOQ) was 0.1 ng/mL; the assay exhibited a linear dynamic range of 0.1-50.0 ng/mL with a determination coefficient (r2) of at least 0.98. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of samples taken up to 320 h after oral administration of 20mg (two 10mg capsules) of I in healthy volunteers demonstrated the applicability to bioequivalence studies.  相似文献   

8.
A sensitive and specific method using a one-step liquid-liquid extraction (LLE) with ethyl acetate followed by high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed and validated for the determination of roxatidine in human plasma using famotidine as an internal standard (IS). Data acquisition was carried out in multiple reaction monitoring (MRM) mode, by monitoring the transitions m/z 307.3-->107.1 for roxatidine and m/z 338.4-->189.1 for famotidine. Chromatographic separation was performed on a reverse phase Hydrosphere C(18) column at 0.2 mL min(-1) using a mixture of methanol-ammonium formate buffer as mobile phase (20:80, v/v; adjusted to pH 3.9 with formic acid). The achieved lower limit of quantification (LLOQ) was 1.0 ng mL(-1) and the standard calibration curve for roxatidine was linear (r(2)=0.998) over the studied range (1-1000 ng mL(-1)) with acceptable accuracy and precision. Roxatidine was found to be stable in human plasma samples under short-, long-term storage and processing conditions. The developed method was validated and successfully applied to the bioequivalence study of roxatidine administrated as a single oral dose (75 mg as roxatidine acetate hydrochloride) to healthy female Korean volunteers.  相似文献   

9.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

10.
A highly sensitive, selective and evaporation free SPE extraction, ESI-LC-MS/MS method has been developed for estimation of misoprostol free acid in human plasma using misoprostol acid-d(5) as an internal standard (IS). The analyte was separated using isocratic mobile phase on reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H] anions, m/z 367-249 for misoprostol acid and m/z 372-249 for the IS. The total run time was 5.0 min and the elution of misoprostol acid and misoprostol acid-d(5) (IS) occurred at 3.6 min. The developed method was validated in human plasma with a lower limit of quantification of 2.5 pg/mL. A linear response function was established for the range of concentrations 2.5-1200 pg/mL (r>0.998) for misoprostol acid in human plasma. The intra and inter-day precision values for misoprostol acid met the acceptance as per FDA guidelines. Misoprostol acid was stable in the battery of stability studies viz., bench-top, auto-sampler and freeze/thaw cycles. The developed assay method was applied to an oral pharmacokinetic study in humans.  相似文献   

11.
Glipizide and rosiglitazone are widely used to treat Type 2 diabetes. In order to investigate drug-drug protein binding interaction between glipizide and rosiglitazone, a method was developed and validated for simultaneously determining the free (unbound) fraction of glipizide and rosiglitazone in plasma employing equilibrium dialysis for the separation of free drug and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantitation. Post-dialysis human plasma or buffer samples of 0.2 ml were extracted using a liquid-liquid extraction procedure and analyzed by a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a Zorbax SB-Phenyl column, ionized using an atmospheric pressure electrospray ionization source and analyzed in positive ion mode with multiple reaction monitoring. The ion transitions monitored were m/z 446-->321 for glipizide, m/z 358-->135 for rosiglitazone, and m/z 271-->155 for tolbutamide (internal standard, IS). The chromatographic run time was 5 min per injection, with retention times of 2.3, 3.4 and 2.3 min for glipizide, rosiglitazone and IS, respectively. The calibration curves of glipizide and rosiglitazone were over the range of 1-2000 ng/ml (r(2)>0.9969) in the combined matrix of human plasma and isotonic sodium phosphate buffer (1:1, v/v). The inter-assay precision and accuracy of the quality control samples were <10.9% of coefficient of variability and >93.5% and 94.5% of nominal concentration for glipizide and rosiglitazone, respectively. The lower limit of quantitation of both glipizide and rosiglitazone was 1.0 ng/ml. Both glipizide and rosiglitazone bound to plasma protein extensively (>99% bound). Glipizide and rosiglitazone free fraction averaged 0.678+/-0.071 and 0.389+/-0.061%, respectively, at plasma concentration of 1000 ng/ml. This developed method proves reproducible and sensitive and its application to clinical samples is also reported.  相似文献   

12.
A simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of tetrahydrobiopterin (BH4) and dopamine in rat brain using epsilon-acetamidocaproic acid (AACA) as an internal standard. Proteins in the samples were precipitated with acetonitrile and then the supernatants were separated by a Sepax Polar-Imidazole (2.1 × 100 mm, i.d., 3 μm) column using a mixture of 10mM ammonium formate in acetonitrile/water (75:25, v/v) as the mobile phase at a flow rate of 300 μl/min. Quantification was performed on a triple quadrupole mass spectrometer employing electrospray ionization with the operating conditions as multiple reaction monitoring (MRM) and positive ion mode from m/z 242.1 → 166.0 for BH4, m/z 154.1 → 90.0 for dopamine and m/z 174.1 → 114.0 for AACA (IS). The total chromatographic run time was for 5.5 min. The method was validated for the analysis of samples: the limit of detection was 10 ng/g. The calibration curve was linear between 10-2000 ng/g for BH4 (r(2)=0.995) and 10-5000 ng/g for dopamine (r(2)=0.997) in the rat brain. Thus, good correlated LC-ESI/MS/MS results were obtained and found to be a powerful tool for the quantitative analysis of BH4 and dopamine in the rat brain.  相似文献   

13.
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg.  相似文献   

14.
Here we present a sensitive and specific liquid chromatography-tandem mass spectrometric method for the quantification of dimenhydrinate (I) in human plasma. Sample preparation is conducted using citalopram (II) addition as an internal standard (IS), liquid-liquid extraction with basified plasma using a mixture hexane/acetate (1:1, v/v) as the extracting solvent, and the final extract reconstituted in the mobile phase. I and II (IS) were injected in a C8 column with the mobile phase composed of methanol:isopropanol:water:formic acid (78.00:19.92:2.00:0.08, v/v/v/v) and monitored using a positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 256.0>167.0 and m/z 325.0>109.0 for I and II, respectively. The limit of quantification (LOQ) was 0.4 ng/mL, the dynamic range being 0.4-200 ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of plasma samples taken up to 24 h after oral administration of 100 mg of dimenhydrinate in healthy volunteers demonstrated its applicability to bioavailability studies.  相似文献   

15.
Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate-formic acid buffer containing 5 mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4 min in positive mode; the calibration curve was linear in the concentration range of 1-200 ng/ml. The lowest limit of quantification (LLOQ) reached 1 ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between -7.4% and 9.1% for three QC concentration levels. The LC-MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.  相似文献   

16.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

17.
A rapid, specific and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for simultaneous quantitation of six Aconitum alkaloids, i.e. aconitine (AC), mesaconitine (MA), hypaconitine (HA), benzoylaconine (BAC), benzoylmesaconine (BMA) and benzoylhypaconine (BHA) in human plasma collected from 18 healthy volunteers after intravenous drop infusion of "SHEN-FU" injectable powder in three different dosages. Lappaconitine was selected as the internal standard (IS). LC/MS/MS system coupled with an electrospray ionization (ESI) source was performed in multiple-reaction monitoring (MRM) mode. The transitions of the Aconitum alkaloids executed as following: m/z 646.3-->586.0 for AC; m/z 632.4-->573.1 for MA; m/z 616.2-->556.1 for HA; m/z 604.2-->104.8 for BAC; m/z 590.1-->104.8 for BMA; m/z 574.1-->104.8 for BHA; m/z 585.2-->161.8 for IS. Sample preparation was performed with solid-phase extraction (SPE) on a 1 mL HLB cartridge prior to analysis. The separation was applied on a Waters C(18) column (1.7 microm, 2.1 mm x 100 mm) and a gradient elution of methanol and 0.1% formic acid-water was used as mobile phase. The retention time was less than 4.5 min. The concentrations ranged from 0.1 to 1000 ng/mL for all six Aconitum alkaloids and showed a good linearity with the correlation coefficient (r(2)) >0.995. The validated method was employed to simultaneous quantitation and successfully used for the first time for the pharmacokinetic evaluation of the six Aconitum alkaloids after intravenous drop administration of "SHEN-FU" injectable powder in phase I clinical trial.  相似文献   

18.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers.  相似文献   

19.
A highly sensitive and enantioselective method has been developed and validated for the determination of levocetirizine [(R)-cetirizine] in human plasma by normal-phase liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization (APCI) interface in the positive ion mode. Enantioselective separation was achieved on a CHIRALPAK AD-H column using an isocratic mobile phase consisting of a mixture of n-hexane, ethyl alcohol, diethylamine, and acetic acid (60:40:0.1:0.1, v/v/v/v). Levocetirizine-D(8) was used as an internal standard (IS). Levocetirizine and the IS were detected by multiple-reaction monitoring (MRM). Mass transitions of analyte and IS were m/z 389.2→201.1 and 397.2→201.1, respectively. Under optimized analytical conditions, a baseline separation of two enantiomers and IS was obtained in less than 11 min. Samples were prepared by a simple two-step extraction by protein precipitation using acetonitrile followed by liquid-liquid extraction with a n-hexane-dichloromethane mixture (50:50, v/v). The standard curve for levocetirizine was linear (r(2)>0.995) in the concentration range 0.5-300 ng/mL. Recovery was between 97.0 and 102.2% at low, medium, and high concentration. The limit of quantification (LOQ) was 0.5 ng/mL. Other method validation parameters, such as precision, accuracy, and stability, were very satisfactory. Finally, the proposed method was successfully applied to the study of enantioselective oral pharmacokinetics of levocetirizine in healthy Korean volunteers.  相似文献   

20.
Tacrolimus (FK506) is a potent immunosuppressant widely used for organ transplantation patients while diltiazem (DTZ), a calcium-channel inhibitor, is often used in renal transplantation patients to prevent post-transplant hypertension. However, DTZ has a significant pharmacokinetic interaction with FK506. In this study, a rapid and sensitive ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of FK506 and DTZ in human whole blood using ascomycin as the internal standard (IS). After extraction of the whole blood samples by ethyl acetate, FK506, DTZ and the IS were subjected to LC/MS/MS analysis using electro-spray positive-ion mode ionization (ESI(+)). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The MS/MS detection was conducted by monitoring the fragmentation of 821.7-->768.9 (m/z) for FK506, 415.5-->310.3 (m/z) for DTZ and 809.8-->757.0 (m/z) for IS. The method had a chromatographic running time of approximately 2 min and linear calibration curves over the concentrations of 0.5-200 ng/mL for FK506 and 2-250 ng/mL for DTZ. The recoveries of liquid-liquid extraction method were 58.3-62.6% for FK506 and 50.4-58.8% for DTZ. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for FK506 and 2 ng/mL for DTZ. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL for FK506 and 5, 25, and 100 ng/mL for DTZ. The validated LC/MS/MS method has been successfully used to analyze the concentrations of FK506 and DTZ in whole blood samples from pharmacokinetic studies in renal transplanted patients.  相似文献   