首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 610 毫秒
1.
Enhanced chemiluminescent assays for hydrolase enzymes have been developed using proehancer and pro-anti-enhancer substrates. Alkaline phosphatase is measured using disodium para-iodophenyl phosphate (proenhancer) which is converted to para-iodophenol and this in turn enhances the light emission from the horseradish peroxidase catalysed chemiluminescent oxidation of luminol by peroxide. An alternative strategy uses para-nitrophenyl phosphate which is converted by alkaline phosphatase to para-nitrophenol which inhibits the enhanced chemiluminescent reaction. The detection limit for the enzyme using the proenhancer and pro-anti-enhancer assays was 100 attomoles and 1 picornole, respectively. The proenhancer strategy was effective in assays for beta-D-galactosidase, beta-D -glucosidase and aryl sulfatase. A limited comparison of the proenhancer and a conventional colorimetric assay for an alkaline phosphatase label in an enzyme immunoassay for alpha-fetoprotein showed good agreement.  相似文献   

2.
A sensitive chemiluminescent sandwich-type enzyme immunoassay for hen egg lysozyme was developed. The assay was performed on polystyrene microtitre plates using immobilized specific polyclonal rabbit antibody against lysozyme, a peroxidase conjugate and the H2O2/luminol-enhanced chemiluminescence detection reagent. The chemiluminescent signal was detected using either a microplate luminometer, or photographic film in a camera luminometer. The detection limit for lysozyme was 0.3 ng/mL, and this was three times lower than that obtained using a colorimetric method with H2O2 and o-phenylendiamine as substrates. Recovery of the assay was 97–112% and the relative standard deviation ranged from 3.6% to 10.3%. The immunoassay overcame interference from the food sample matrix when lysozyme, used as a bacteriostatic agent, was measured.  相似文献   

3.
The mechanism of peroxidase-catalysed oxidation of luminol by H2O2 was studied. The stopped-flow technique was used to measure the rate constants for the reactions between the oxidized forms of peroxidase with luminol and the following substrates: p-iodophenol, p-bromophenol, p-clorophenol, o-iodophenol, m-iodophenol, luciferin, and 2-iodo-6-hydroxybenzothiazole. The correlation between kinetic parameters and the degree of enhancement was established. The effect of charged synthetic polymers and specific antibodies on the peroxidase activity in the enhanced chemiluminescent reaction. Novel homogenous methods of luminescent immunoassay (LIA) for (1) antibodies to insulin, (2) insulin and (3) antibodies to trinitrophenyl group are proposed on the basis of regulatory facilities of the enhanced chemiluminescent reaction. Based on the enhanced chemiluminescent reaction a peroxidase flow-injection assay was developed and successfuly tested in the flow-injection enzyme immunoassays for human IgG and for thyroxin (T4). The immunoassay proposed has a detection limit of 10?9M for IgG and 10?11M for T4, the overall time of the assay being 5–15 min.  相似文献   

4.
Immunoassays are often coupled to peroxidase activity for antigen detection. Sensitivity and speed of detection has been increased by the advent of hybrid methods such as immuno-PCR (polymerase chain reaction). However, a more simplified immunoassay that retains both colorimetric peroxidase detection and effective DNA amplification in a setting closer to field application conditions has been nonexistent. Here we describe a method that successfully combines a competitive immunoassay with the new isothermal quadruplex-primed amplification (QPA) to generate excess quadruplex reporter molecules with intrinsic peroxidase DNAzyme activity.  相似文献   

5.
The development of a highly sensitive analytical method for oxytocin could be useful in the diagnosis and treatment of autistic spectrum disorder. We previously developed a colorimetric enzyme immunoassay (EIA) for plasma oxytocin measurement. In this study, we developed a method to measure oxytocin concentrations using a higher sensitivity bioluminescent EIA. Biotinylated oxytocin bridged with five lysine residues was used in a competitive format. The standard curve range for oxytocin was 1.0 to 1000 pg/assay. In addition, there was good correlation between the colorimetric and bioluminescent immunoassays in terms of measured oxytocin concentration (r = 0.9665, n = 48). The bioluminescent EIA for plasma oxytocin was more rapid and provided higher sensitivity than the colorimetric immunoassay, making it suitable for clinical application.  相似文献   

6.
The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R2 = 0.94 and R2 = 0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.  相似文献   

7.
The wild-type anionic tobacco peroxidase and its Glu141Phe mutant have been expressed in Escherichia coli, and reactivated to yield active enzymes. A Glu141Phe substitution was made with the tobacco anionic peroxidase (TOP) to mimic neutral plant peroxidases, such as horseradish peroxidase (HRP). Both recombinant forms of tobacco peroxidase show extremely high activity in luminol oxidation with hydrogen peroxide, and thus, preserve the unique property of the native tobacco peroxidase, a superior chemiluminescent reagent. The chemiluminescent signal intensity for both recombinant forms of TOP is orders of magnitude higher than that for wild-type recombinant HRP. The substitution slightly increases TOP activity and stability in the reaction course, but has almost no effect on the optimal parameters of the reaction (pH, luminol and hydrogen peroxide concentrations) and calibration plot. Comparison of substrate specificity profiles for recombinant TOP and HRP demonstrates that Glu141 has no principal effect on the enzyme activity. It is not the presence of the negative charge at the haem edge, but the high redox potential of TOP Compounds I and II that provides high activity towards aromatic amines and aminophenols, and luminol in particular.  相似文献   

8.
We developed a novel chemiluminescent assay of β-D -galactosidase (β-gal) based on the chemiluminescence of indole. 5-Bromo-4-chloro-3-indolyl-β-D -galactopyranoside (X-gal) was used as a substrate for β-gal and also as a light emitter. X-gal was hydrolysed by β-gal to liberate free indoxyl, followed by oxidation to indigo dye, and simultaneously produces hydrogen peroxide (H2O2). H2O2 reacts with the residual X-gal in the presence of horseradish peroxidase (HRP) to emit light. The measurable range of β-gal obtained by this method was 6 × 10−14 mol/L to 6 × 10−11 mol/L; the detection limit was 3 amol/assay. This chemiluminescent assay could be applied to an enzyme immunoassay of thyroxine using β-gal as the enzyme label. © 1998 John Wiley & Sons, Ltd.  相似文献   

9.
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.  相似文献   

10.
《Luminescence》2003,18(2):72-78
We developed a competitive chemiluminescent (CL) enzyme immunoassay for rapid, sensitive analysis of 19‐nortestosterone (19‐NT) in bovine urine. Anti‐19‐NT polyclonal antibodies were raised in rabbits using a 19‐NT‐hemisuccinate derivative conjugated with ovalbumin; the derivative was also conjugated with horseradish peroxidase (HRP) as a label. Antibodies were immobilized on 384‐well black polystyrene microtitre plates and HRP‐labelled 19‐NT activity was measured using an efficient chemiluminescent substrate (SuperSignal® ELISA Femto) after 3 min incubation. Emitted light was recorded using a conventional, photomultiplier‐tube‐based microtitre plate reader or a sensitive back‐illuminated, cooled CCD camera. The developed method fulfils all the requirements of precision (intra‐ and inter‐assay CV < 10%) and accuracy (mean recovery 94–112%), with a detection limit of 0.03 ppb (1.1 × 10?9 mol/L) in a urine matrix. Chemiluminescence enhances detectability of the HRP‐labelled tracer (thus lowering the limit of detection with respect to colorimetry) and reduces analysis time. The 384‐well microtitre plate cuts the sample/reagent volume (20 µL), a five‐fold reduction with respect to the conventional 96‐well microtitre plate. The developed method is suitable for high‐throughput screening of 19‐NT in urine samples, with reduced costs as compared with conventional colorimetric enzyme immunoassays. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
Isoenzyme c of horseradish peroxidase (HRP‐C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP‐C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP‐C, the JcGP1‐induced reaction was enhancer independent, which made the enzyme‐linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long‐term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long‐term stable CL signal combined with enhancer‐independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
Some biochemical and catalytic properties of peroxidase from Arthromyces ramosus (EC 1.11.7.1) in chemiluminescent reaction of luminol oxidation by hydrogen peroxide were investigated. The second order rate constants were determined by the stopped-flow technique. Optimal conditions to quantity the enzyme were found, the detection limit being 5.10(-13) M. The peroxidase was used as a marker in the human IgG immunoassay.  相似文献   

13.
Bio- and chemiluminescence have proved sensitive enough to compete with chromogenic and radioisotopic tracers for in situ detection. However, they must also provide a discriminant morphological analysis of the specific signal. We have tested seven bio-or chemiluminescent reagents for tissue antigen and nucleic acid detection by immunocytochemistry (ICC) or in situ hybridization (ISH). They were based on luminescent detection of peroxidase, aikaline phosphatase, β-galactosidase or xanthine oxidase. We also explored whether high molecular weight polymers could increase the spatial definition of the photon emission. An ICCD camera was used to collect the light signal provided by immunolabelling of endothelial cells and by ISH of human papilloma virus on cell smears. Among the enzyme-luminescent substrate combinations tested, the enhanced luminol chemiluminescence (ECL) gave the best resolution of the specific signal. The other systems were mainly hampered by a high diffusion of the reaction product over the tissue section. Unfortunately, in this case, the high molecular weight polymers tested were inefficient. However, the addition of polyvinylalcohol (PVA) or polyvinylpyrrolidone (PVP) significantly improved respectively the definition and intensity of ECL photon emission. We demonstrate that chemiluminescence gives a morphological resolution allowing histological examination. The extension of this new application, now depends on physicochemical adaptation of chemiluminescent reagents to the constraints of tissue detection.  相似文献   

14.
Rapid, sensitive and point-of-care detection of foodborne pathogenic bacteria is essential for food safety. In this study, we found that hemin-concanavalin A hybrid nanoflowers (HCH nanoflowers), as solid mimic peroxidase, could catalyze oxidation of 2,2′-azino-bis (3-ethylbenzthiazoline-6-sulfonic acid) diammonium salt (ABTS) in the presence of H2O2 to a green-colored product. HCH nanoflowers, integrating the essential functions of both biological recognition and signal amplification, meet the requirements of signal labels for colorimetric immunoassay of bacteria. In view of the excellent peroxidase mimetic catalytic activity of HCH nanoflowers, a colorimetric biosensing platform was newly constructed and applied for sensitive detection of foodborne Escherichia coli O157:H7 (E. coli O157:H7). The corresponding detection limits was as low as 4.1?CFU/mL with wide linear ranges (101–106?CFU/mL).  相似文献   

15.
2-Naphthyl acetate acts as a pro-enhancer of the luminol–H2O2–horseradish peroxidase reaction. Cholinesterase hydrolyses the bound acetyl group and produces 2-naphthol, and this compound is an enhancer of the chemiluminescent reaction. We studied the kinetics of chemiluminescent emission and the influence of 2-naphthyl acetate and cholinesterase enzyme concentration. The cholinesterase concentration versus chemiluminescence intensity maximum was linear for cholinesterase between 0 and 181 μU/mL, with a detection limit of 8 μU/mL and a relative standard deviation of 9.5% (n = 3), for a sample containing 90.67 μU/mL of cholinesterase.  相似文献   

16.
Zhu Y  Xu L  Ma W  Chen W  Yan W  Kuang H  Wang L  Xu C 《Biosensors & bioelectronics》2011,26(11):4393-4398
In this paper, we demonstrate the application of versatile G-quadruplex-hemin DNAzymes in an immunoassay for detecting Microcystin-LR (MC-LR). Taking advantage of the high peroxidase activity of G-quadruplex-hemin complexes and the enhancement effect of gold nanoparticles (AuNPs), the method showed simple, high sensitive and selectivity detection of target toxin residues in water samples. The coated antigen, MC-LR-ovalbumin (OVA) coated on a plate, competed for MC-LR antibody with added target analyte to form antibody-antigen immune complexes. Subsequently, the immune complex reacted with G-quadruplex-labeled secondary antibodies for colorimetric detection of MC-LR. This assay specifically determined MC-LR in the linear range of 0.1-10 ng/ml, with a limit of detection (LOD) of 0.05 ng/mL for MC-LR. The results indicated that the novel immunoassay was an alternative to traditional plate-based immunoassay for MC-LR residue screening due to this method met the standard of World Health Organization (WHO) requirements for MC-LR content in drinking water (1 ng/mL).  相似文献   

17.
Firefly luciferin–luciferase bioluminescence is known for its high quantum yield (41.0 ± 7.4%). Given this high quantum yield, application of this bioluminescence is expected to be useful in the field of clinical diagnostics. The kinetic profile of this bioluminescence exhibits an instant rise (<1 s) and a rapid decay in light emission (decreased to 42% after 5 s). In this study, we applied four enhancers including coenzyme A, inosine5′‐triphosphate sodium salt, sodium tripolyphosphate and potassium pyrophosphate to prolong light emission. When these enhancers were used, luminescence was only decreased to 89, 83, 87 and 82% after 5 s, respectively. These materials modified the kinetic profile of bioluminescence so that the luminescence is more suitable for clinical application. It becomes more suitable because they enable highly sensitive integration and simplification of a device by separating luminescence measurements from dispensing of reagents. Using these enhancers, we then developed a bioluminescent enzyme immunoassay (BLEIA) for hepatitis B virus surface antigen (HBsAg) that employed firefly luciferase as a labeling enzyme. We compared the results obtained from the HBsAg BLEIA method with the conventional chemiluminescent enzyme immunoassay method, and found a satisfactory correlation (r = 0.984, n = 118). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
We have developed a two-site immunoassay for human prolactin using two monoclonal antibodies: one of them immobilized on the solid phase and the other labelled with biotin. The serum is incubated simultaneously with the antibody-coated bead, the biotinylated antibody and the tracer (streptavidin–isoluminol or avidin–peroxidase complex). Our experimental work has been directed towards a common set of reagents to capture the prolactin and then, with different tracers, towards obtaining on the calibration curve the same results for unknown samples. On the basis of the positive results we obtained, we have developed a kit that can be used by the customer or as an enzyme-immunoassay or as a chemiluminescent immunoassay, depending on instrumentation available, spectrophotometer or luminometer.  相似文献   

19.
The measurement of multiple antigens in a single sample poses clinical and methodological challenges. Here we describe the validation of a multiplexed sandwich enzyme-linked immunosorbent assay (ELISA) array (microELISA) of nine antigens. The antigens tested simultaneously were: alpha-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen 125 (CA 125), CA 15-3, CA 19-9, beta-human chorionic gonadotropin (beta-hCG), luteinizing hormone (LH), and follicle stimulating hormone (FSH). At least 44 clinical samples were tested for each antigen. microELISA results for the nine antigens were then compared with clinical laboratory results obtained for the same antigens in individual chemiluminescent immunoassays. The microELISA had a coefficient of variation (cv) of 7.3% within an assay and 12.6% for assays run at different times. A statistical comparison of results from the microELISA with results from the clinical laboratory showed that the assays had correlation coefficients ranging from 0.99 to 0.76, and Deming regression demonstrated that four of the nine assays were high-quality assays and not statistically different to the individual assays. To determine if the differences in the assays were due to methodology, the microELISA was also compared with conventional ELISAs using identical antibodies and reagents. Deming regression demonstrated that five of the eight assays were high-quality, indicating that a poor correlation between a microELISA and an individual immunoassay are partly due to antibody differences.  相似文献   

20.
A solid phase immunoassay for aldosterone using enhanced chemiluminescent detection has been developed. Monoclonal antibodies against aldosterone were used for the immune reaction and compared with polyclonal antibodies. Uniform Protein A coated polystyrene tubes were used as solid phase for the monoclonal antibody and second (anti-rabbit) antibody coated tubes for the polyclonal antibody. Horseradish peroxidase was covalently linked to aldosterone as enzyme label. Optimum conditions were established for the generation and measurement of the luminescent reactions using luminol, p-iodophenol as enhancer and hydrogen peroxide. The advantages of this assay are the high sensitivity with a detection limit of 100fg/tube, the prolonged luminescence signal with a simplification of the measurement (simpler detectors, external start pipetting) and the short measure time with the possibility of repeated measurement. The coefficients of variation were 4.2%–7.3% in the concentration range 140–1180 pmol/l. The assay showed a significant correlation (r = 0.91) with the ELISA. The aldosterone concentrations in plasma and saliva of patients with Conn's syndrome were significantly increased, and in patients with Addison's disease were found near the detection limit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏