 共查询到20条相似文献,搜索用时 31 毫秒
1.
The gradient fields in magnetic resonance imaging (MRI) will in some circumstances exceed the ICNIRP guidelines of occupational electromagnetic field exposure when personnel are near the scanner during MRI scanning. In this work we have shown that using commercially available modified sequences for noise reduction purposes, exposure will decrease by a factor of 1.5 with preserved image quality. This is a first step toward optimizing occupational exposure within the scanner room without affecting image quality. Bioelectromagnetics 31:85–87, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

2.

Background

Magnetic nanoparticles are gaining great roles in biomedical applications as targeted drug delivery agents or targeted imaging contrast agents. In the magnetic nanoparticle applications, quantification of the nanoparticle density deposited in a specified region is of great importance for evaluating the delivery of the drugs or the contrast agents to the targeted tissues. We introduce a method for estimating the nanoparticle density from the displacement of tissues caused by the external magnetic field.

Methods

We can exert magnetic force to the magnetic nanoparticles residing in a living subject by applying magnetic gradient field to them. The nanoparticles under the external magnetic field then exert force to the nearby tissues causing displacement of the tissues. The displacement field induced by the nanoparticles under the external magnetic field is governed by the Navier's equation. We use an approximation method to get the inverse solution of the Navier's equation which represents the magnetic nanoparticle density map when the magnetic nanoparticles are mechanically coupled with the surrounding tissues. To produce the external magnetic field inside a living subject, we propose a coil configuration, the Helmholtz and Maxwell coil pair, that is capable of generating uniform magnetic gradient field. We have estimated the coil currents that can induce measurable displacement in soft tissues through finite element method (FEM) analysis.

Results

From the displacement data obtained from FEM analysis of a soft-tissue-mimicking phantom, we have calculated nanoparticle density maps. We obtained the magnetic nanoparticle density maps by approximating the Navier's equation to the Laplacian of the displacement field. The calculated density maps match well to the original density maps, but with some halo artifacts around the high density area. To induce measurable displacement in the living tissues with the proposed coil configuration, we need to apply the coil currents as big as 104A.

Conclusions

We can obtain magnetic nanoparticle maps from the magnetically induced displacement data by approximating the Navier's equation under the assumption of uniform-gradient of the external magnetic field. However, developing a coil driving system with the capacity of up to 104A should be a great technical challenge.  相似文献   

3.
Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the cartilage in both the underformed and deformed states. The objectives of the work reported in this article were to 1) design an apparatus that could apply highly repeatable cyclic compressive loads of 400 N and operate in the bore of an MRI scanner, 2) demonstrate that the apparatus and MRI scanner can be successfully integrated to observe 3D deformations in a phantom material, 3) use the apparatus to determine the load cycle necessary to achieve a steady-state deformation response in normal bovine articular cartilage samples using a flat-surfaced and nonporous indentor in unconfined compression. Composed of electronic and pneumatic components, the apparatus regulated pressure to a double-acting pneumatic cylinder so that (1) load-controlled compression cycles were applied to cartilage samples immersed in a saline bath, (2) loading and recovery periods within a cycle varied in time duration, and (3) load magnitude varied so that the stress applied to cartilage samples was within typical physiological ranges. In addition the apparatus allowed gating for MR image acquisition, and operation within the bore of an MRI scanner without creating image artifacts. The apparatus demonstrated high repeatability in load application with a standard deviation of 1.8% of the mean 400 N load applied. When the apparatus was integrated with an MRI scanner programmed with appropriate pulse sequences, images of a phantom material in both the underformed and deformed states were constructed by assembling data acquired through multiple signal acquisitions. Additionally, the number of cycles to reach a steady-state response in normal bovine articular cartilage was 49 for a total cycle duration of 5 seconds, but decreased to 33 and 27 for increasing total cycle durations of 10 and 15 seconds, respectively. Once the steady-state response was achieved, 95% of all displacements were within +/- 7.42 microns of the mean displacement, indicating that the displacement response to the cyclic loads was highly repeatable. With this performance, the MRI-loading apparatus system meets the requirements to create images of articular cartilage from which 3D deformation can be determined.  相似文献   

4.
The ability to visualize cell infiltration in experimental auto-immune encephalomyelitis (EAE), a well-known animal model for multiple sclerosis in humans, was investigated using a clinical 1.5-T magnetic resonance imaging (MRI) scanner, a custom-built, high-strength gradient coil insert, a 3-D fast imaging employing steady-state acquisition (FIESTA) imaging sequence and a superparamagnetic iron oxide (SPIO) contrast agent. An "active labeling" approach was used with SPIO administered intravenously during inflammation in EAE. Our results show that small, discrete regions of signal void corresponding to iron accumulation in EAE brain can be detected using FIESTA at 1.5 T. This work provides early evidence that cellular abnormalities that are the basis of diseases can be probed using cellular MRI and supports our earlier work which indicates that tracking of iron-labeled cells will be possible using clinical MR scanners.  相似文献   

5.
Calculations are presented of the induced electric fields and current densities in the cartilage of the knee produced by a coil applicator developed for applying pulsed magnetic fields to osteoarthritic knees. This applicator produces a sawtooth-like magnetic field waveform composed of a series of 260-micros pulses with a peak to peak magnitude of approximately 0.12 mT in the cartilage region. The simulations were performed using a recently developed 3 dimensional finite difference frequency domain technique for solving Maxwell's equations with an equivalent circuit model. The tissue model was obtained from the anatomically segmented human body model of Gandhi. The temporal peak electric field magnitude was found to be -153 mV/m, averaged within the medial cartilage of the knee for the typical dB/dt excitation levels of this coil. The technique can be extended to analyze other excitation waveforms and applicator designs.  相似文献   

6.
Although magnetic resonance imaging (MRI) is a useful technique, only a few studies have investigated the dynamic behavior of small subjects using MRI owing to constraints such as experimental space and signal amount. In this study, to acquire high-resolution continuous three-dimensional gravitropism data of pea (Pisum sativum) sprouts, we developed a small-bore MRI signal receiver coil that can be used in a clinical MRI and adjusted the imaging sequence. It was expected that such an arrangement would improve signal sensitivity and improve the signal-to-noise ratio (SNR) of the acquired image. All MRI experiments were performed using a 3.0-T clinical MRI scanner. An SNR comparison using an agarose gel phantom to confirm the improved performance of the small-bore receiver coil and an imaging experiment of pea sprouts exhibiting gravitropism were performed. The SNRs of the images acquired with a standard 32-channel head coil and the new small-bore receiver coil were 5.23±0.90 and 57.75±12.53, respectively. The SNR of the images recorded using the new coil was approximately 11-fold higher than that of the standard coil. In addition, when the accuracy of MR imaging that captures the movement of pea sprout was verified, the difference in position information from the optical image was found to be small and could be used for measurements. These results of this study enable the application of a clinical MRI system for dynamic plant MRI. We believe that this study is a significant first step in the development of plant MRI technique.  相似文献   

7.
Computational fluid dynamics (CFD) is an increasingly used method for investigation of hemodynamic parameters and their alterations under pathological conditions, which are important indicators for diagnosis of cardiovascular disease. In hemodynamic simulation models, the employment of appropriate boundary conditions (BCs) determines the computational accuracy of the CFD simulation in comparison with pressure and velocity measurements. In this study, we have first assessed the influence of inlet boundary conditions on hemodynamic CFD simulations. We selected two typical patients suspected of carotid artery disease, with mild stenosis and severe stenosis. Both patients underwent digital subtraction angiography (DSA), magnetic resonance angiography, and the invasive pressure guide wire measured pressure profile. We have performed computational experiments to (1) study the hemodynamic simulation outcomes of distributions of wall shear stress, pressure, pressure gradient and (2) determine the differences in hemodynamic performances caused by inlet BCs derived from DSA and Womersley analytical solution. Our study has found that the difference is related to the severity of the stenosis; the greater the stenosis, the more the difference ensues. Further, in our study, the two typical subjects with invasively measured pressure profile and thirty subjects with ultrasound Doppler velocimeter (UDV) measurement served as the criteria to evaluate the hemodynamic outcomes of wall shear stress, pressure, pressure gradient and velocity due to different outlet BCs based on the Windkessel model, structured-tree model, and fully developed flow model. According to the pressure profiles, the fully developed model appeared to have more fluctuations compared with the other two models. The Windkessel model had more singularities before convergence. The three outlet BCs models also showed good correlation with the UDV measurement, while the Windkessel model appeared to be slightly better (\( R^{2} = 0.942 \)). The structured-tree model was seen to have the best performance in terms of available computational cost and accuracy. The results of our numerical simulation and the good correlation with the computed pressure and velocity with their measurements have highlighted the effectiveness of CFD simulation in patient-specific human carotid artery with suspected stenosis.  相似文献   

8.
PurposeTo simulate radiofrequency (RF) burns that frequently occur at skin–skin and skin–bore wall contact points.MethodsRF burn injuries (thumb–thigh and elbow–bore wall contacts) that typically occur on the lateral side of the body during 1.5 T magnetic resonance imaging (MRI) scans were simulated using a computational human model. The model was shifted to investigate the influence of the position of the patient in an MRI scanner. The specific absorption rate (SAR), electric field, and temperature were mapped.ResultsRegarding the contact points located near the edge of the birdcage transmission coil, under the allowable maximum RF power exposure i.e., the average whole-body SAR at the safety limit value (2 W/kg), the 10-g-tissue-averaged SAR (SAR10g) at those points significantly increased for both the thumb–thigh (180 W/kg) and elbow–bore wall (48 W/kg) cases. Both values significantly exceeded the highest safety limit of the partial-body SAR (10 W/kg). The electric field, the square of which is proportional to SAR, was remarkably high near the edge of the birdcage transmission coil. The peak SAR10g for each injury case was associated with contact-point peak temperatures that reached 52 °C at approximately 1 min following RF exposure onset; a 1-min period of exposure to this temperature causes a first-degree burn.ConclusionsWe demonstrated high heat generation in RF burn injury cases in silico. The RF heating occurring on the lateral side of the body was strongly dependent on the electric field distribution, which is dominantly determined by an RF transmission coil.  相似文献   

9.
Blood flow in a steady magnetic field has been of great interest over recent years. Many researchers have examined the effects of magnetic fields on velocity profiles and arterial pressure, and major studies have focused on steady or sinusoidal flows. In this paper, we present a solution for pulsed magnetohydrodynamic blood flow with a somewhat realistic physiological pressure wave obtained using a Windkessel lumped model. A pressure gradient is derived along a rigid vessel placed at the output of a compliant module which receives the ventricle outflow. Then, velocity profile and flow rate expressions are derived in the rigid vessel in the presence of a steady transverse magnetic field. As expected, results showed flow retardation and flattening. The adaptability of our solution approach allowed a comparison with previously addressed flow cases and calculations presented a good coherence with those well established solutions.  相似文献   

10.
Changes in the distribution of flowing erythrocytes in a straight cylinder were studied under an inhomogeneous magnetic field. The magnetic field was applied perpendicular to a cylinder, which had a 90° side vessel at the end (oriented towards the magnetic field) to detect changes in the erythrocyte distribution within the cylinder. (1) The attraction of paramagnetic erythrocytes by the magnetic field was demonstrated by an increase in the concentration (or number) of erythrocytes drawn into the side vessel. The flow of diamagnetic, oxygenated erythrocytes was unaffected. (2) The degree of attraction of the paramagnetic erythrocytes was proportional to ``(magnetic susceptibility)' and to ``(magnetic flux density) × (magnetic field gradient)' up to 10 T2/m, but it saturated at high magnetic field. The onset of the saturation depended on the magnetic susceptibility of the erythrocytes. (3) The degree of attraction depended on the hematocrit of the flowing erythrocyte suspension, with a maximum value at a low hematocrit. These phenomena are explained on the basis of the balance between the paramagnetic attractive force of the magnetic field and the collision rate between erythrocytes. Received: 2 May 1996 / Accepted: 1 July 1996  相似文献   

11.
12.

Introduction

Neuroimaging of macaques at ultra-high field (UHF) is usually conducted by combining a volume coil for transmit (Tx) and a phased array coil for receive (Rx) tightly enclosing the monkey’s head. Good results have been achieved using vertical or horizontal magnets with implanted or near-surface coils. An alternative and less costly approach, the travelling-wave (TW) excitation concept, may offer more flexible experimental setups on human whole-body UHF magnetic resonance imaging (MRI) systems, which are now more widely available. Goal of the study was developing and validating the TW concept for in vivo primate MRI.

Methods

The TW Primate System (TWPS) uses the radio frequency shield of the gradient system of a human whole-body 7 T MRI system as a waveguide to propagate a circularly polarized B1 field represented by the TE11 mode. This mode is excited by a specifically designed 2-port patch antenna. For receive, a customized neuroimaging monkey head receive-only coil was designed. Field simulation was used for development and evaluation. Signal-to-noise ratio (SNR) was compared with data acquired with a conventional monkey volume head coil consisting of a homogeneous transmit coil and a 12-element receive coil.

Results

The TWPS offered good image homogeneity in the volume-of-interest Turbo spin echo images exhibited a high contrast, allowing a clear depiction of the cerebral anatomy. As a prerequisite for functional MRI, whole brain ultrafast echo planar images were successfully acquired.

Conclusion

The TWPS presents a promising new approach to fMRI of macaques for research groups with access to a horizontal UHF MRI system.  相似文献   

13.
Summary A novel approach to tailored selective excitation for the measurement of NMR spectra in non-deuterated aqueous solutions (WATERGATE, WATER suppression by GraAdient-Tailored Excitation) is described. The gradient echo sequence, which effectively combines one selective 180° radiofrequency pulse and two field gradient pulses, achieves highly selective and effective water suppression. This technique is ideally suited for the rapid collection of multi-dimensional data since a single-scan acquisition produces a pure phase NMR spectrum with a perfectly flat baseline, at the highest possible sensitivity. Application to the fast measurement of 2D NOE data of a 2.2. mM solution of a double-stranded DNA fragment in 90% H2O at 5 °C is presented.  相似文献   

14.
A magnetic resonance (MR) imaging scanner operated at 0.5 T with a specially constructed receiving coil was used to measure volumes of primary spontaneous tumors in rats and guinea pigs. The coil was used to improve the signal to noise ratio (S/N) of the MR images of tumors in these small animals. The tumor volume was determined by the summation of the volume of contiguous slices or ellipsoid approximation. The accuracy of the volume measurement was better when the numerical integration was used in calculating the slice volume. The open sided saddle (OSS) coil used as the receiving coil gave better S/N than that of the standard head coil.  相似文献   

15.
Noninvasive imaging at the molecular level is an emerging field in biomedical research. This paper introduces a new technology synergizing two leading imaging methodologies: positron emission tomography (PET) and magnetic resonance imaging (MRI). Although the value of PET lies in its high-sensitivity tracking of biomarkers in vivo, it lacks resolving morphology. MRI has lower sensitivity, but produces high soft-tissue contrast and provides spectroscopic information and functional MRI (fMRI). We have developed a three-dimensional animal PET scanner that is built into a 7-T MRI. Our evaluations show that both modalities preserve their functionality, even when operated isochronously. With this combined imaging system, we simultaneously acquired functional and morphological PET-MRI data from living mice. PET-MRI provides a powerful tool for studying biology and pathology in preclinical research and has great potential for clinical applications. Combining fMRI and spectroscopy with PET paves the way for a new perspective in molecular imaging.  相似文献   

16.
IntroductionRecent advances have enabled fast magnetic resonance imaging (MRI) of solid materials. This development has opened up new applications for MRI, but, at the same time, uncovered new challenges. Previously, MRI-invisible materials like the housing of MRI detection coils are now readily depicted and either cause artifacts or lead to a decreased image resolution. In this contribution, we present versatile, multi-nuclear single and dual-tune MRI coils that stand out by (1) a low hydrogen content for high-resolution MRI of dry solids without artifacts; (2) a modular approach with exchangeable inductors of variable volumes to optimally enclose the given object; (3) low cost and low manufacturing effort that is associated with the modular approach; (4) accurate sample placement in the coil outside of the bore, and (5) a wide, single- or dual-tune frequency range that covers several nuclei and enables multinuclear MRI without moving the sample.

Materials and Methods

The inductors of the coils were constructed from self-supporting copper sheets to avoid all plastic materials within or around the resonator. The components that were mounted at a distance from the inductor, including the circuit board, coaxial cable and holder were manufactured from polytetrafluoroethylene.

Results and Conclusion

Residual hydrogen signal was sufficiently well suppressed to allow 1H-MRI of dry solids with a minimum field of view that was smaller than the sensitive volume of the coil. The SNR was found to be comparable but somewhat lower with respect to commercial, proton-rich quadrature coils, and higher with respect to a linearly-polarized commercial coil. The potential of the setup presented was exemplified by 1H / 23Na high-resolution zero echo time (ZTE) MRI of a model solution and a dried human molar at 9.4 T. A full 3D image dataset of the tooth was obtained, rich in contrast and similar to the resolution of standard cone-beam computed tomography.  相似文献   

17.
For more than a decade, Midwest Research Institute (MRI) has investigated the effects of exposure to 60 Hz electric and magnetic fields (EMF) on human physiology, performance, and biochemistry. This accumulated experience, new research directions, and limited resources made it important to design more comprehensive and operationally cost-effective exposure facilities. Here we describe the new, integrated laboratory exposure test facilities recently constructed at MRI and present data on relevant characteristics of the exposure systems. Concentric coil systems were developed to generate uniform magnetic fields within the three new exposure rooms, with rapid cancellation of the field to ambient levels in the rest of the laboratory. Control systems are fully automated, computer-based, and independent. These provide the operational flexibility needed to present fields of different magnitudes, frequencies, and polarization. The local geomagnetic field can be modulated and/or canceled, and both AC and DC fields can be presented in various combinations. Capabilities for conducting double-blind experiments with true active-sham exposure conditions were implemented using bifilar windings and applying current flow in the opposite direction for each wire in a pair. The new facilities provide a comprehensive capability for laboratory-based human research on the potential effects of exposure to AC and DC magnetic fields.  相似文献   

18.
Concern regarding the spread of silver carp (Hypopthalmichthys molitrix) and bighead carp (Aristichthysc nobilis) through the Illinois River has prompted the development of an Acoustic Fish Deterrent (AFD) system. The application of this technology has resulted in a need to understand the auditory physiology of fish other than the target species, in order to minimise the effect of the AFD barrier on the ecology of indigenous fish populations. To this end, both the structures involved in sound reception and the hearing abilities of the paddlefish (Polyodon spathula) and the lake sturgeon (Acipenser fulvescens) are studied here using a combination of morphological and physiological approaches, revealing that both fish are responsive to sounds ranging in frequency from 100 to 500 Hz. The lowest hearing thresholds from both species were acquired from frequencies in a bandwidth of between 200 and 300 Hz, with higher thresholds at 100 and 500 Hz. The rationale for studying hearing in P. spathula and A. fulvescens in particular, is the value placed on them by both the commercial caviar producing industry and by the recreational fisheries sector. The hearing abilities of twelve P. spathula and twelve A. fulvescens were tested in sound fields dominated by either sound pressure or particle motion, with the results showing that acipenseriform fish are responsive to the motion of water particles in a sound field, rather than the sound pressure component. In this study, we measure the intensity of the sound field required to evoke threshold responses using a pressure sensitive hydrophone, as pressure dominated sound fields are the most audible acoustic condition for specialists like H. molitrix and A. nobilis (the target species). The results of the auditory examination clearly show that P. spathula and A. fulvescens are not sensitive to sound pressure, and will therefore have a significantly higher deterrent threshold than H. molitrix and A. nobilis in a pressure dominated sound field.  相似文献   

19.
A simplified in vitro model of the spinal canal, based on in vivo magnetic resonance imaging, was used to examine the hydrodynamics of the human spinal cord and subarachnoid space with syringomyelia. In vivo magnetic resonance imaging (MRI) measurements of subarachnoid (SAS) geometry and cerebrospinal fluid velocity were acquired in a patient with syringomyelia and used to aid in the in vitro model design and experiment. The in vitro model contained a fluid-filled coaxial elastic tube to represent a syrinx. A computer controlled pulsatile pump was used to subject the in vitro model to a CSF flow waveform representative of that measured in vivo. Fluid velocity was measured at three axial locations within the in vitro model using the same MRI scanner as the patient study. Pressure and syrinx wall motion measurements were conducted external to the MR scanner using the same model and flow input. Transducers measured unsteady pressure both in the SAS and intra-syrinx at four axial locations in the model A laser Doppler vibrometer recorded the syrinx wall motion at 18 axial locations and three polar positions. Results indicated that the peak-to-peak amplitude of the SAS flow waveform in vivo was approximately tenfold that of the syrinx and in phase (SAS approximately 5.2 +/- 0.6 ml/s, syrinx approximately 0.5 +/- 0.3 ml/s). The in vitro flow waveform approximated the in vivo peak-to-peak magnitude (SAS approximately 4.6 +/- 0.2 ml/s, syrinx approximately 0.4 +/- 0.3 ml/s). Peak-to-peak in vitro pressure variation in both the SAS and syrinx was approximately 6 mm Hg. Syrinx pressure waveform lead the SAS pressure waveform by approximately 40 ms. Syrinx pressure was found to be less than the SAS for approximately 200 ms during the 860-ms flow cycle. Unsteady pulse wave velocity in the syrinx was computed to be a maximum of approximately 25 m/s. LDV measurements indicated that spinal cord wall motion was nonaxisymmetric with a maximum displacement of approximately 140 microm, which is below the resolution limit of MRI. Agreement between in vivo and in vitro MR measurements demonstrates that the hydrodynamics in the fluid filled coaxial elastic tube system are similar to those present in a single patient with syringomyelia. The presented in vitro study of spinal cord wall motion, and complex unsteady pressure and flow environment within the syrinx and SAS, provides insight into the complex biomechanical forces present in syringomyelia.  相似文献   

20.
Polyethylene glycol (PEG)ylated and rhodamine-labeled liposomes loaded with maghemite nanocrystals provide a novel nanoscaled hybrid system for magnetic targeting to solid tumors in possible combination with double in vivo imaging by fluorescence microscopy and magnetic resonance imaging (MRI). Human prostate adenocarcinoma tumors implanted in mice were used as a system model. A magnetic field gradient was produced at the tumor level by external apposition of a magnet. Noninvasive fibered confocal fluorescence microscopy was successfully used to track the liposomes in vivo within organs and tumor blood vessels. Active targeting to the magnet-exposed tumors was clearly shown, in agreement with previous MRI studies. The liposomes were driven and accumulated within the microvasculature through a process that preserved vesicle structure and content.  相似文献   