首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 553 毫秒
1.
Conductive polymer nanotubules of 1,2-diaminobenzene (1,2-DAB) were prepared using a porous polycarbonate membrane template, placed on a Pt foil and used to support the polymer, then, the electropolymerisation was performed by chronocoulometry. The obtained conductive polymer nanostructures were then placed on Pt electrode and used to support highly dispersed prussian blue (PB), which acts as the active component for H2O2 detection. The observed good stability of PB as catalyst of H2O2 was related to the presence of organic non-conventional conducting polymers in a composite nanostructured film. These nanostructured polymer/PB composite films were also characterised by scanning electron microscopy (SEM) and Raman spectroscopy. The non-conventional conducting polymer nanotubules/PB modified Pt electrodes were tested by cyclic voltammeter for stability at different pH values, then, by amperometry, for hydrogen peroxide, ascorbic acid, acetaminophen, uric acid and acetylcholine. Glucose oxidase (GOD), lactate oxidase (LOD), L-amino acid oxidase (L-AAOD), alcohol oxidase (AOD), glycerol-3-phosphate oxidase (GPO), lysine oxidase (LyOx), and choline oxidase (ChOx) were immobilised on PB layer supported on 1,2-diaminobenzene (1,2-DAB) nanotubules onto the Pt electrodes. Different strategies for enzyme immobilisation were performed and used. Analytical parameters such as reproducibility, interference rejection, response time, storage and operational stability of the sensors have been studied and optimised. Results provide a guide to design high sensitive, stable and interference-free biosensors. The glucose biosensors assembled with nanostructured poly(1,2-DAB) showed a detection limit of 5 x 10(-5) mol l(-1), a wide linearity range (5 x 10(-5) to 5 x 10(-3) mol l(-1)), a high selectivity, a stability of 3 months at 4 degrees C, and at least 4 weeks at room temperature. Similar analytical parameters and stability were also studied for L-(+)-lactic acid, L-leucine, ethanol, glycerol-3-phosphate, lysine, and choline biosensors.  相似文献   

2.
Chitosan was chosen as a natural polymer for dispersion of single walled carbon nanotubes (SWNT) based on its ability to efficiently solubilize SWNTs to form a stable dispersion. Moreover, chitosan films deposited on a surface of a glassy carbon (GC) electrode are mechanically stable. Further stabilisation of the chitosan film containing SWNT (CHIT-SWNT) was done by chemical crosslinking with glutaraldehyde and free aldehyde groups produced a substrate used for covalent immobilisation of galactose oxidase (GalOD). Different galactose biosensor configurations were tested with optimisation of composition of inner and outer membrane; and enzyme immobilisation procedure, as well. Detection of oxygen uptake by GalOD on CHIT-SWNT layer at -400 mV is robust and, when flow injection analysis (FIA) was applied for assays, a low detection limit (25 microM) and very high assay throughput rate (150 h-1) was achieved. This new galactose biosensor offers highly reliable detection of galactose with R.S.D. well below 2% and it has been successfully applied to assaying galactose in a blood sample with recovery index between 101.2 and 102.7%.  相似文献   

3.
Arrays of nanoscopic gold tubes were prepared by electroless deposition of the metal within the pores of polycarbonate particle track-etched membranes (PTM). Glucose oxidase (Gox) was immobilised onto preformed self-assembled monolayers (SAMs) (mercaptoethylamine or mercaptopropionic acid) on electroless gold via cross-linking with glutaraldehyde or covalent attachment by carbodiimide coupling. The effectiveness of the different steps in the Gox immobilisation procedure was assessed by contact angle measurements, cyclic voltammetry and X-ray photoelectron spectroscopy. The enzyme loading was estimated by radioactivity measurements. The sensitivity to beta-glucose of these different biosensors has been evaluated. Glucose responses as large as 400 nA mM(-1) cm(-2) have been obtained. To our knowledge, this sensitivity value is amongst the highest values reported in the literature for comparable biosensor systems.  相似文献   

4.
Preparation of semiconducting films by electropolymerisation of a monomer which is itself a redox mediator is an attractive and simple method for biosensor fabrication. A polymeric film of the redox dye thionine (phenothiazine) enables the stable immobilisation of polyphenol oxidase (tyrosinase) while acting as mediator for the enzymatic process. The immobilisation method is based on an inner crosslinked tyrosinase layer which contains thionine with an electropolymerised film of poly(thionine) on top. This method gave the most stable redox couple for poly(thionine) and exhibited the greatest response stability. The sensor was tested using a range of synthetic oestrogens and phenolic compounds, which are suspected endocrine disruptors/oestrogen mimics. The device responded well to all compounds tested with limits of detection ranging from 1 to 23 microM (based on three times S/N ratio). The tyrosinase/poly(thionine) electrode response to phenol was 3 orders of magnitude greater than the unmediated response in the absence of poly(thionine).  相似文献   

5.
A novel detection system for the determination of glucose in the presence of clinically important interferents, based on the use of dual sensors and flow-injection analysis (FIA), is described. The normalisation methodology involves measurement of the interference signal at a reference sensor; this signal can then be subtracted from the glucose sensor signal (post-run) to give a corrected measurement of the glucose concentration. The detection system consists of a thin layer cell with dual glassy carbon working electrodes. One electrode was surface modified to act asglucose biosensor by immobilisation of glucose oxidase (GOx) (from Aspergillus niger) with 1% glutaraldehyde and bovine serum albumin. The second electrode (glucose oxidase omitted) was utilised to measure the interference signal responding only to electroactive species present in the injected sample. A computer controlled multichannel potentiostat was used for potential application and current monitoring duties. The sensor responses were saved in ASCII format to facilitate post-run analysis in Microsoft Excel. Cyclic voltammetry (CV) was utilised to investigate the manner in which the interference signal contributed to the total signal obtained at the biosensor in the presence of glucose. The kinetic parameters Imax and the apparent Michaelis-Menten constant, K′m, were calculated for the sensor operating under flow-injection conditions.  相似文献   

6.
Four different silica sol-gel films: methyltrimethoxysilane (MTMOS), tetraethoxysilane (TEOS), 3-aminopropyltriethoxysilane (APTOS) and 3-glycidoxypropyl-trimethoxysilane (GOPMOS) assembled onto highly oriented pyrolytic graphite (HOPG) were characterized using atomic force microscopy (AFM), due to their use in the development of glucose biosensors. The chemical structure of the oxysilane precursor and the composition of the sol-gel mixture both influenced the roughness, the size and the distribution of pores in the sol-gel films, which is relevant for enzyme encapsulation. The GOPMOS sol-gel film fulfils all the morphological characteristics required for good encapsulation of the enzyme, due to a smooth topography with very dense and uniform distribution of only small, 50nm diameter, pores at the surface. APTOS and MTMOS sol-gel films developed small pores together with large ones of 300-400nm that allow the leakage of enzymes, while the TEOS film formed a rough and incomplete network on the electrode, less suitable for enzyme immobilisation. GOPMOS sol-gel film with encapsulated glucose oxidase and poly(neutral red) redox mediator, prepared by in situ electropolymerization, were also morphologically characterized by AFM. The AFM results explain the variation of the stability in time, sensitivity and limit of detection obtained with different oxysilane sol-gel encapsulated glucose oxidase biosensors with redox mediator.  相似文献   

7.
A two-substrate mathematical model of microspherical optical enzymatic glucose sensors is presented. The sensors are based on the well-known oxidation of glucose by glucose oxidase, and are constructed by the encapsulation of glucose oxidase within hydrogel microspheres coated with ultrathin polyelectrolyte multilayer films. In order to measure glucose via changes in oxygen concentration, a fluorescent oxygen indicator is co-encapsulated with the enzyme. The model was used to predict the temporal and spatial distributions of glucose and oxygen within the sphere for step increases in bulk glucose concentration. In addition, the model was used to observe the effect of varying sensor parameters, namely sphere size, film thickness, enzyme concentration, and mass transport of substrate and co-substrate within the sphere and film coatings, on the response of the sensors. A major finding was that the application of {PSS/PAH} films as thin as 12 nm can drastically improve the sensor performance over uncoated sensors based on calcium alginate microspheres. The model is proposed as an important tool for a priori design of these complex sensor structures.  相似文献   

8.
Layer-by-layer assembly of glucose oxidase (GOx) with single-wall carbon nanotubes (SWCNTs) is achieved on the electrode surface based on the electrostatic attraction between positively charged GOx in pH 3.8 buffer and negatively charged carboxylic groups of CNTs. The cyclic voltammetry and electrochemical impedance spectroscopy are used to characterize the formation of multilayer films. In deaerated buffer solutions, the cyclic voltammetry of the multilayer films of {GOx/CNT}n shows two pairs of well-behaved redox peaks that are assigned to the redox reactions of CNTs and GOx, respectively, confirming the effective immobilization of GOx on CNTs using the layer-by-layer technique. The redox peak currents of GOx increase linearly with the increased number of layers indicating the uniform growth of GOx in multilayer films. The dependence of the cyclic voltammetric response of GOx in multilayer films on the scan rate and pH is also studied. A linear decrease of the reduction current of oxygen at the {GOx/CNT}-modified electrodes with the addition of glucose suggests that such multilayer films of GOx retain the bioactivity and can be used as reagentless glucose biosensors.  相似文献   

9.
Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100 x 100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.  相似文献   

10.
A method is described for the incorporation of tiron as a substrate for tyrosinase enzyme into a polypyrrole film deposited on indium titanium oxide (ITO) glass. The presence of tiron in the polypyrrole film is verified by cyclic voltammetry (CV). The enzyme activity using the polypyrrole-tiron film is confirmed by the catalytic conversion of immobilised substrate to quinones by the enzyme. The use of both potentiometric and optical methods for the detection of the catalytic activity of the polypyrrole-tiron film and their potential use for the determination of monophenolase activity of apple polyphenol oxidase is described. This is the first report of this kind whereby tiron has been immobilised in a polypyrrole matrix for the enzyme activity determination.  相似文献   

11.
Solid‐phase microextraction (SPME) is widely used in analytical laboratories for the analysis of organic compounds, thanks to its simplicity and versatility. In the present work, the synthesis and evaluation of imprinted films for SPME by electropolymerisation of pyrrole alone or in the presence of ethylene glycol dimethacrylate is proposed. Sulfadimethoxine (SDM), a sulfonamide antibiotic, was used as template molecule. Initially, a molecularly imprinted polymer film was prepared by electropolymerisation of pyrrole onto a platinum foil, using SDM as template. The SDM template was removed by overoxidation. The behaviour of SDM on imprinted and non‐imprinted polymers was investigated by differential pulse voltammetry, and a clear imprinting effect was observed, which was confirmed by rebinding experiments using both conventional and electrochemically enhanced‐SPME. However, in general, the extraction efficiency was rather low (<6%) and unspecific interactions are too high. Attempts to increase extraction efficiency were unsuccessful, but the incorporation of ethylene glycol dimethacrylate to the films reduced unspecific interactions to a certain extent. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
A new electrochemical DNA biosensor for bovine papillomavirus (BPV) detection that was based on screen-printed electrodes was comprehensively studied by electrochemical methods of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A BPV probe was immobilised on a working electrode (gold) modified with a polymeric film of poly-L-lysine (PLL) and chitosan. The experimental design was carried out to evaluate the influence of polymers, probe concentration (BPV probe) and immobilisation time on the electrochemical reduction of methylene blue (MB). The polymer poly-L-lysine (PLL), a probe concentration of 1μM and an immobilisation time of 60min showed the best result for the BPV probe immobilisation. With the hybridisation of a complementary target sequence (BPV target), the electrochemical signal decreased compared to a BPV probe immobilised on the modified PLL-gold electrode. Viral DNA that was extracted from cattle with papillomatosis also showed a decrease in the MB electrochemical reduction, which suggested that the decreased electrochemical signal corresponded to a bovine papillomavirus infection. The hybridisation specificity experiments further indicated that the biosensor could discriminate the complementary sequence from the non-complementary sequence. Thus, the results showed that the development of analytical devices, such as a biosensor, could assist in the rapid and efficient detection of bovine papillomavirus DNA and help in the prevention and treatment of papillomatosis in cattle.  相似文献   

13.
The performance of a new glucose biosensor based on the combination of biocatalytic activity of glucose oxidase (GOx) with the electrocatalytic properties of CNTs and neutral red (NR) for the determination of glucose is described. This sensor is comprised of a multiwalled carbon nanotubes (MWNTs) conduit functionalized with NR and Nafion (Nf) as a binder and glucose oxidase as a biocatalyst. Neutral red was covalently immobilized on carboxylic acid groups of the CNTs via carbodiimide reaction. The functionalized MWNTs were characterized by microscopic, spectroscopic and thermal methods. The MWNT-NR-GOx-Nf nanobiocomposite was prepared by mixing the GOx solution with NR functionalized CNTs followed by mixing homogeneously with Nafion. The performance of the MWNT-NR-GOx-Nf nanobiocomposite modified electrode was examined by electrochemical impedance spectroscopy and cyclic voltammetry. The catalytic reduction of hydrogen peroxide liberated from the enzymatic reaction of glucose oxidase upon glucose with NR functionalized CNTs leads to the selective detection of glucose. The excellent electrocatalytic activity and the influence of nanobiocomposite film result in good characteristics such as low potential detection of glucose with a large determination range from 1 x 10(-8) to 1 x 10(-3)M with a detection limit of 3 x 10(-9)M glucose, a short response time (with 4s), good stability and anti-interferent ability. The improved electrocatalytic activity and stability made the MWNT-NR-GOx-Nf nanobiocomposite biosensor system a potential platform to immobilize different enzymes for other bioelectrochemical applications.  相似文献   

14.
A novel amperometric glucose sensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared with a vapor deposition method. The sol-gel film was uniform, porous and showed a very low mass transport barrier and a regular dense distribution of GOD. Titania sol-gel matrix retained the native structure and activity of entrapped enzyme and prevented the cracking of conventional sol-gel glasses and the leaking of enzyme out of the film. With ferrocenium as a mediator the glucose sensor exhibited a fast response, a wide linear range from 0.07 to 15 mM. It showed a good accuracy and high sensitivity as 7.2 microA cm(-2) mM(-1). The general interferences coexisted in blood except ascorbic acid did not affect glucose determination, and coating Nafion film on the sol-gel film could eliminate the interference from ascorbic acid. The serum glucose determination results obtained with a flow injection analysis (FIA) system showed an acceptable accuracy, a good reproducibility and stability and indicated the sensor could be used in FIA determination of glucose. The vapor deposition method could fabricate glucose sensor in batches with a very small amount of enzyme.  相似文献   

15.
Biocompatible nanosized polyamidoamine (PAMAM) dendrimer films provided a suitable microenvironment for heme proteins to transfer electron directly with underlying pyrolytic graphite (PG) electrodes. Hemoglobin (Hb), myoglobin (Mb), horseradish peroxidase (HRP), and catalase (Cat) incorporated in PAMAM films exhibited a pair of well-defined, quasi-reversible cyclic voltammetric peaks, respectively, characteristic of the protein heme Fe(III)/Fe(II) redox couples. While Hb-, Mb-, and HRP-PAMAM films showed the cyclic voltammetry (CV) peaks at about -0.34 V vs. saturated calomel electrode (SCE) in pH 7.0 buffers, Cat-PAMAM films displayed the peak pair at a more negative potential of -0.47 V. The protein-PAMAM films demonstrated a surface-confined or thin-layer voltammetric behavior. The electrochemical parameters such as apparent heterogeneous electron transfer rate constants (k(s)) and formal potentials (E (degrees ')) were estimated by square wave voltammetry with nonlinear regression analysis. UV-vis and IR spectroscopy showed that the proteins retained their near-native secondary structures in PAMAM films. Oxygen, hydrogen peroxide, and nitrite were catalytically reduced at the protein-PAMAM film electrodes, showing the potential applicability of the films as the new type of biosensors or bioreactors based on direct electrochemistry of the proteins.  相似文献   

16.
The aim of this study was to develop a rapid method to measure alpha-fetoprotein (AFP) in human serum by use of one-step sandwich enzyme-linked immunosorbent assay (ELISA)-based immunobiosensor with disposable screen-printed carbon electrode technology. Prussian blue (PB) was deposited using cyclic voltammetry (CV) on the surface of electrode to catalyze H202 from the reaction of glucose oxidase. It took only about 30 min to complete the whole experimental procedure through flow injection analysis (FIA). A detection range obtained is in the range from 5 to 500 ng/ml AFP. This detection seems to be quick, reliable and practical.  相似文献   

17.
Hemoglobin (Hb) in the hyaluronic acid (HA) was cast at pyrolytic graphite (PG) electrodes for researching its electrochemical and electrocatalytic properties. The formal potential and electron transfer rate constant of Hb on HA films were determined, and the stability of the films, the pH effect, and the influence of supporting electrolyte concentrations upon Hb electrochemistry on the films were investigated by cyclic voltammetry and square wave voltammetry. UV-Vis absorption and reflectance absorption infrared (RAIR) spectra showed that the protein on HA film retained near-native secondary structure. The stable Hb-HA/PG gave analytically useful electrochemical catalytic responses to hydrogen peroxide. Thus, the property of the HA film for sorption and retention of water maybe utilized to develop some new biosensors.  相似文献   

18.
Screen-printed carbon electrodes (SPCEs) have been successfully exploited as disposable sensors for the measurement of 2,6-dinitrotoluene (2,6-DNT) using a stripping voltammetric method. Initial investigations were undertaken using cyclic voltammetry (CV) to characterise the redox behaviour at the SPCEs. Further studies were then performed to deduce the optimum applied potential and accumulation time for the stripping voltammetric procedure. In addition, a study was carried out to ascertain whether small volumes of samples could be reliably used for analysis. From these studies it was shown that a 100 microl aliquot of sample could be analysed and the calibration plot was linear from 161 ng ml(-1) to 137 microg ml(-1) (R(2)=0.9991), the former concentration being the detection limit. The effects of the major components of human saliva at concentrations normally present were investigated. Of the individual components tested, only Cl(-) and albumen were found to interfere. The presence of the latter could be easily overcome by the addition of (NH(4))(2)SO(4). An interference study was also carried out on some inorganic and organic species that may be present in water samples. The sensors were evaluated by carrying out 2,6-DNT determinations on spiked and unspiked human saliva, dust wipe and potable water samples. Mean recoveries of 47.5, 73.4 and 102.4% were obtained; coefficients of variation of 7.88, 6.63 and 6.42% were calculated for a concentration of 9.1 microg ml(-1) in water, 10.6 microg ml(-1) saliva samples, and 141.1 ng cm(-2) for dust wipe samples, respectively. The performance characteristics show that the method holds promise and reliable data may be obtained for 2,6-DNT in bioanalysis and public health.  相似文献   

19.
An amperometric bilirubin biosensor was fabricated by complexing the Mn(II) ion with a conducting polymer and the final biosensor surface was coated with a thin polyethyleneimine (PEI) film containing an enzyme, ascorbate oxidase (AsOx). The complexation between poly-5,2'-5',2'-terthiophene-3-carboxylic acid (PolyTTCA) and Mn(II) through the formation of Mn-O bond was confirmed by XPS. The PolyTTCA-Mn(II) complex was also characterized using cyclic voltammetry. The PolyTTCA-Mn(II)/PEI-AsOx biosensor specifically detect bilirubin through the mediated electron transfer by the Mn(II) ion. To optimize the experimental condition, various experimental parameters such as pH, temperature, and applied potential were examined. A linear calibration plot for bilirubin was obtained between 0.1 microM and 50 microM with the detection limit of 40+/-3.8 nM. Interferences from other biological compounds, especially ascorbate and dopamine were efficiently minimized by coating the biosensor surface with PEI-AsOx. The bilirubin sensor exhibited good stability and fast response time (<5s). The applicability of this bilirubin sensor was tested in a human serum sample.  相似文献   

20.
A conducting molecularly imprinted polymer (CMIP) film, based on polypyrrole, was electrosynthesized for selective uptake/release and determination of naproxen. The film was prepared by incorporation of a template anion (naproxen) during the electropolymerization of pyrrole into a platinum electrode using the cyclic voltammetry method. Overoxidized polypyrrole films with cavities complementary to the template were used as a potential-induced selective recognition element in the solid-phase sorbent. Various important fabricating factors, which control the performance of the CMIP film, were investigated using fluorescence spectroscopy. The measured fluorescence intensities of released solutions were related to the concentrations of naproxen taken up into the films. Several key parameters such as applied potential and time for uptake and release were varied to achieve the optimal sorption procedure. The film template with naproxen exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5×10(-8) to 3×10(-7)molml(-1) and 7×10(-6) to 8×10(-4)molml(-1), and the limit of detection was 1×10(-8)molml(-1). The CMIP films, as the electrochemically controlled solid-phase sorbent, were applied for the selective cleanup and quantification of trace amounts of naproxen from physiological samples. Scanning electron microscopy confirmed the nanostructure morphology of the films.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号