首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A series of model peptides in the form of quaternary ammonium salts at the N‐terminus was efficiently prepared by the solid‐phase synthesis. Tandem mass spectrometric analysis of the peptide quaternary ammonium derivatives was shown to provide sequence confirmation and enhanced detection. We designed the 2‐(1,4‐diazabicyclo[2.2.2] octylammonium)acetyl quaternary ammonium group which does not suffer from neutral losses during MS/MS experiments. The presented quaternization of 1,4‐diazabicyclo[2.2.2]octane (DABCO) by iodoacetylated peptides is relatively easy and compatible with standard solid‐phase peptide synthesis. This methodology offers a novel sensitive approach to analyze peptides and other compounds. Copyright © 2011 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

2.
Use of the 4‐pyridylmethyl ester group for side‐chain protection of glutamic acid residues in solid‐phase peptide synthesis enables switching of the charge state of a peptide from negative to positive, thus making detection by positive ion mode ESI‐MS possible. The pyridylmethyl ester moiety is readily removed from peptides in high yield by hydrogenation. Combining the 4‐pyridylmethyl ester protecting group with benzyl ester protection reduces the number of the former needed to produce a net positive charge and allows for purification by RP HPLC. This protecting group is useful in the synthesis of highly acidic peptide sequences, which are often beset by problems with purification by standard RP HPLC and characterization by ESI‐MS. Copyright © 2014 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

3.
Short cyclic peptides have a great interest in therapeutic, diagnostic and affinity chromatography applications. The screening of ‘one‐bead‐one‐peptide’ combinatorial libraries combined with mass spectrometry (MS) is an excellent tool to find peptides with affinity for any target protein. The fragmentation patterns of cyclic peptides are quite more complex than those of their linear counterparts, and the elucidation of the resulting tandem mass spectra is rather more difficult. Here, we propose a simple protocol for combinatorial cyclic libraries synthesis and ring opening before MS analysis. In this strategy, 4‐hydroxymethylbenzoic acid, which forms a benzyl ester with the first amino acid, was used as the linker. A glycolamidic ester group was incorporated after the combinatorial positions by adding glycolic acid. The library synthesis protocol consisted in the following: (i) incorporation of Fmoc‐Asp[2‐phenylisopropyl (OPp)]‐OH to Ala‐Gly‐oxymethylbenzamide‐ChemMatrix, (ii) synthesis of the combinatorial library, (iii) assembly of a glycolic acid, (iv) couple of an Ala residue in the N‐terminal, (v) removal of OPp, (vi) peptide cyclisation through side chain Asp and N‐Ala amino terminus and (vii) removal of side chain protecting groups. In order to simultaneously open the ring and release each peptide, benzyl and glycolamidic esters were cleaved with ammonia. Peptide sequences could be deduced from the tandem mass spectra of each single bead evaluated. The strategy herein proposed is suitable for the preparation of one‐bead‐one‐cyclic depsipeptide libraries that can be easily open for its sequencing by matrix‐assisted laser desorption/ionisation MS. It employs techniques and reagents frequently used in a broad range of laboratories without special expertise in organic synthesis. Copyright © 2014 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

4.
Pemetrexed (Pem) is a novel antimetabolite type of anticancer drug that demonstrated promising clinical activity in a wide variety of solid tumors, including non‐small cell lung carcinoma and malignant pleural mesothelioma. It inhibits enzymes involved in the folate pathway, for which the presence of its free carboxylic groups is necessary. The heteroaromatic ring system of Pem has a modifiable amino group, which opens a possibility to apply a new strategy to conjugate Pem to carrier molecules. Considering this as well as the necessity of untouched carboxylic groups of Pem in the new conjugates, we developed a new synthesis strategy. Here, we describe the synthesis and the characterization of new Pem‐peptide conjugates in which cell‐penetrating octaarginine or/and lung‐targeting H‐Ile‐Glu‐Leu‐Leu‐Gln‐Ala‐Arg‐NH2 peptide is attached to the drug by thioether bond. The conjugates characterized by RP‐HPLC and MS exhibited cytostatic effect in vitro on non‐small cell lung carcinoma as well as on human leukemia cell lines. The IC50 values of the conjugates were similar, but the conjugates with H‐Ile‐Glu‐Leu‐Leu‐Gln‐Ala‐Arg‐NH2 sequence were slightly more effective. Our data show that the in vitro cytostatic effect of the free Pem was essentially maintained after conjugation with cell‐penetrating or cell‐targeting peptides. Thus, the conjugation strategy reported could lead to the development of a new generation of active Pem conjugates. Copyright © 2011 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

5.
We developed and characterized 6 new cysteine mass tags for high-sensitivity peptide analysis. The structural features are: (1) iodoacetyl group for thiol tagging, (2) hydrophilic character for reducing sample loss, (3) tertiary amino, quaternary ammonium, or guanidino group for high proton affinity, and (4) no amide bonding for minimizing fragmentation of tag moiety in collision-induced dissociation. By using these tags, 2- to 200-fold MS sensitivity was achieved, compared to control peptide with carbamydomethylation.  相似文献   

6.
Kwok Y  Sung WC  Lin AL  Liu HH  Chou FA  Hsieh SS  Leng CH  Chong P 《Proteomics》2011,11(13):2620-2627
The structural analysis of post‐translational modifications (PTMs) of lipoproteins is difficult due to the hydrophobic properties of their fatty acid moieties. At the present time, the relative positions of fatty acid components on the N‐acyl‐S‐diacylglycerylcysteine core structure has not been specifically identified in any natural or bacterial expressed recombinant lipoproteins. In this study, we describe a rapid solid‐phase extraction using acetonitrile and isopropanol method that can be performed manually to isolate large amounts of relatively pure lipopeptides generated by the limited tryptic‐digestion of recombinant lipoproteins. Using these lipopeptides and LC/MS mass spectra analysis, two groups of N‐terminal lipidated (diacyl or triacyl) molecules that differ by one fatty acid unit were successfully identified. This LC/MS method also provided the separation of lipopeptides differing by 14 Da for the on‐line MS identification. Multiple‐stage fragmentation analyses of the di‐ and triacyl lipopeptides using both the positive and negative ion modes enabled to identify the putative structure of the N‐acyl‐S‐diacylglycerylcysteine containing an amide bond to palmitic acid at the N‐terminal cysteine, a palmitic acid at sn1 position, and an unsaturated fatty acid of either hexadecenoic acid, cyclopropaneoctanoic acid, oleic acid and nonadecenoic acid at sn2 position of diacylglycerol residue through ester bonding. For diacyl lipoprotein, the saturated palmitoyl fatty acid group is absent at sn1 position of glycerol‐derived lipid residue of lipopeptide.  相似文献   

7.
Introduction – Biosynthesis of terretonin was studied due to the interesting skeleton of this series of sesterterpenoids. Very recently, López‐Gresa reported two new sesterterpenoids (terretonins E and F) which are inhibitors of the mammalian mitochondrial respiratory chain. Mass spectrometry (MS), especially tandem mass spectrometry, has been one of the most important physicochemical methods for the identification of trace natural products due to it rapidity, sensitivity and low levels of sample consumption. The potential application prospect and unique skeleton prompted us to study structural characterisation using MS. Objective – To obtain sufficient information for rapid structural elucidation of this class of compounds using MS. Methodology – The elemental composition of the product ions was confirmed by low‐energy ESI‐CID‐QTOF‐MS/MS analyses. The fragmentation pathways were postulated on the basis of ESI‐QTOF‐MS/MS/MS and ESI‐IT‐MSn spectra. Common features and major differences between ESI‐QTOF‐MS/MS and IT‐MSn spectra were compared. For ESI‐QTOF‐MS/MS/MS experiments, capillary exit voltage was raised to induce in‐source dissociation. Ammonium acetate or acetic acid were added into solutions to improve the intensity of [M + H]+. The collision energy was optimised to achieve sufficient fragmentation. Some fragmentation pathways were unambiguously proposed by the variety of abundance of fragment ions at different collision energies even without MSn spectra. Results – Fragmentation pathways of five representative sesterterpenoids were elucidated using ESI‐QTOF‐MS/MS/MS and ESI‐IT‐MSn in both positive‐ and negative‐ion mode. The key group of characterising fragmentation profiles was ring B, and these fragmentation patterns are helpful to identify different types of sestertepenoids. Conclusion – Complementary information obtained from fragmentation experiments of [M + H]+ (or [M + NH4]+) and [M ? H]? precursor ions is especially valuable for rapid identification of this kind of sesterterpenoid.  相似文献   

8.
We have been engaged in the microwave‐solid phase peptide synthesis (SPPS) synthesis of the phenylglycine (Phg)‐containing pentapeptide H‐Ala‐Val‐Pro‐Phg‐Tyr‐NH2 (1) previously demonstrated to bind to the so‐called BIR3 domain of the anti‐apoptotic protein XIAP. Analysis of the target peptide by a combination of RP‐HPLC, ESI‐MS, and NMR revealed the presence of two diastereoisomers arising out of the racemisation of the Phg residue, with the percentage of the LLLDL component assessed as 49%. We performed the synthesis of peptide (1) using different microwave and conventional stepwise SPPS conditions in attempts to reduce the level of racemisation of the Phg residue and to determine at which part of the synthetic cycle the epimerization had occurred. We determined that racemisation occurred mainly during the Fmoc‐group removal and, to a much lesser extent, during activation/coupling of the Fmoc‐Phg‐OH residue. We were able to obtain the desired peptide with a 71% diastereomeric purity (29% LLLDL as impurity) by utilizing microwave‐assisted SPPS at 50 °C and power 22 Watts, when the triazine‐derived coupling reagent DMTMM‐BF4 was used, together with NMM as an activator base, for the incorporation of this residue and 20% piperidine as an Fmoc‐deprotection base. In contrast, the phenylalanine analogue of the above peptide, H‐Ala‐Val‐Pro‐Phe‐Tyr‐NH2 (2), was always obtained as a single diastereoisomer by using a range of standard coupling and deprotection conditions. Our findings suggest that the racemisation of Fmoc‐Phg‐OH, under both microwave‐SPPS and stepwise conventional SPPS syntheses conditions, is very facile but can be limited through the use of the above stated conditions. Copyright © 2012 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

9.
A thorough understanding of the fragmentation processes in MS/MS can be a powerful tool in assessing the resulting peptide and protein identifications. We here present the freely available, open‐source FragmentationAnalyzer tool ( http://fragmentation‐analyzer.googlecode.com ) that makes it straightforward to analyze large MS/MS data sets for specific types of identified peptides, using a common set of peptide properties. This enables the detection of fragmentation pattern nuances related to specific instruments or due to the presence of post‐translational modifications.  相似文献   

10.
The Escherichia coli proteome was digested with trypsin and fractionated using SPE on a C18 SPE column. Seven fractions were collected and analyzed by CZE‐ESI‐MS/MS. The separation was performed in a 60‐cm‐long linear polyacrylamide‐coated capillary with a 0.1% v/v formic acid separation buffer. An electrokinetic sheath‐flow electrospray interface was used to couple the separation capillary with an Orbitrap‐Velos operating in higher‐energy collisional dissociation mode. Each CZE‐ESI‐MS/MS run lasted 50 min and total MS time was 350 min. A total of 23 706 peptide spectra matches, 4902 peptide IDs, and 871 protein group IDs were generated using MASCOT with false discovery rate less than 1% on the peptide level. The total mass spectrometer analysis time was less than 6 h, the sample identification rate (145 proteins/h) was more than two times higher than previous studies of the E. coli proteome, and the amount of sample consumed (<1 μg) was roughly fourfold less than previous studies. These results demonstrate that CZE is a useful tool for the bottom‐up analysis of prokaryote proteomes.  相似文献   

11.
Peptide chemical ligation chemistries, which allow the chemoselective coupling of unprotected peptide fragments, are useful tools for synthesizing native polypeptides or unnatural peptide‐based macromolecules. We show here that the phenylthiocarbonyl group can be easily introduced into peptides on α or ε amino groups using phenylthiochloroformate and standard solid‐phase method. It reacts chemoselectively with cysteinyl peptides to give an alkylthiocarbamate bond. S,N‐shift of the alkylaminocarbonyl group from the Cys side chain to the α‐amino group did not occur. The method was used for linking two peptide chains through their N‐termini, for the synthesis of a cyclic peptide or for the synthesis of di‐ or tetravalent multiple antigenic peptides (MAPs). Thiocarbamate ligation is thus complementary to thioether, thioester or disulfide ligation methods. Copyright © 2008 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

12.
13.
The 4‐methoxybenzyloxymethyl (MBom) group was introduced at the Nπ‐position of the histidine (His) residue by using a regioselective procedure, and its utility was examined under standard conditions used for the conventional and the microwave (MW)‐assisted solid phase peptide synthesis (SPPS) with 9‐fluorenylmethyoxycarbonyl (Fmoc) chemistry. The Nπ‐MBom group fulfilling the requirements for the Fmoc strategy was found to prevent side‐chain‐induced racemization during incorporation of the His residue even in the case of MW‐assisted SPPS performed at a high temperature. In particular, the MBom group proved to be a suitable protecting group for the convergent synthesis because it remains attached to the imidazole ring during detachment of the protected His‐containing peptide segments from acid‐sensitive linkers by treatment with a weak acid such as 1% trifluoroacetic acid in dichloromethane. We also demonstrated the facile synthesis of Fmoc‐His(π‐MBom)‐OH with the aid of purification procedure by crystallization to effectively remove the undesired τ‐isomer without resorting to silica gel column chromatography. This means that the present synthetic procedure can be used for large‐scale production without any obstacles. Copyright © 2012 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

14.
Summary Due to the increasing interest in the use of oligonucleotide analogues as antisense and antigene drugs, we designed a chiral analogue constituted of a peptidic frame bearing nucleobases in suitable positions (C-PNA). We recently reported the synthesis of four nonnatural α-amino acids with the DNA bases in the lateral chain. In this paper we present an improved synthesis of the Fmoc monomers and their polymerisation to polypeptidic oligonucleotide analogues using a modification of the standard protocol for solid phase peptide synthesis.  相似文献   

15.
During the final step of t‐Boc/Bzl, solid‐phase peptide synthesis (SPPS)‐protecting groups from amino acids (aa) side chains must be removed from the target peptides during cleavage from the solid support . These reaction steps involve hydrolysis with hydrogen fluoride (HF) in the presence of a nucleophile (scavenger), whose function is to trap the carbocations produced during SN1‐type reactions. Five peptide sequences were synthesised for evaluating p‐methoxyphenol effectiveness as a potent scavenger. After the synthesis, the resin–peptide was then separated into two equal parts to be cleaved using two scavengers: conventional reactive p‐cresol (reported in the literature as an effective acyl ion eliminator) and p‐methoxyphenol (hypothesised as fulfilling the same functions as the routinely used scavenger). Detailed analysis of the electrostatic potential map (EPM) revealed similarities between these two nucleophiles, regarding net atomic charge, electron density distribution, and similar pKa values. Good scavenger efficacy was observed by chromatography and mass spectrometry results for the synthesised molecules, which revealed that p‐methoxyphenol can be used as a potent scavenger during SPPS by t‐Boc/Bzl strategy, as similar results were obtained using the conventional scavenger.  相似文献   

16.
La1 is a 73‐residue cysteine‐rich peptide isolated from the scorpion Liocheles australasiae venom. Although La1 is the most abundant peptide in the venom, its biological function remains unknown. Here, we describe a method for efficient chemical synthesis of La1 using the native chemical ligation (NCL) strategy, in which three peptide components of less than 40 residues were sequentially ligated. The peptide thioester necessary for NCL was synthesized using an aromatic N‐acylurea approach with Fmoc‐SPPS. After completion of sequential NCL, disulfide bond formation was carried out using a dialysis method, in which the linear peptide dissolved in an acidic solution was dialyzed against a slightly alkaline buffer to obtain correctly folded La1. Next, we determined the disulfide bonding pattern of La1. Enzymatic and chemical digests of La1 without reduction of disulfide bonds were analyzed by liquid chromatography/mass spectrometry (LC/MS), which revealed two of four disulfide bond linkages. The remaining two linkages were assigned based on MS/MS analysis of a peptide fragment containing two disulfide bonds. Consequently, the disulfide bonding pattern of La1 was found to be similar to that of a von Willebrand factor type C (VWC) domain. To our knowledge, this is the first report of the experimental determination of the disulfide bonding pattern of peptides having a single VWC domain as well as their chemical synthesis. La1 synthesized in this study will be useful for investigation of its biological role in the venom. Copyright © 2015 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

17.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

18.
Døskeland AP 《Amino acids》2006,30(1):99-103
Summary. A simple method is described to identify signature peptides derived from polyubiquitin (polyUb) chains. The method is based on MALDI-TOF MS/MS analysis after chemically assisted fragmentation, and works on peptides isolated from polyacrylamide gels. PolyUb chains branched at K48 and K63 were chosen as models for Ub-protein conjugates. They were resolved by SDS-PAGE, and their tryptic peptides (in-gel-trypsinolysis) derivatized with 3-sulfopropinic acid NHSester to obtain chemically assisted fragmentation during the MS/MS analysis. PolyUb-K63 produced a single peptide identified as 55TLSDYNIQK63 (GG)ESTLHLVLR72. PolyUb-K48 produced two branched signature peptides identified as 43LIFAGK48(GG)QLEDGR54 and 43LIFAGK48(LRGG)QLEDGR54. The recovery of signature peptide with LRGG as branched chain underscores the need to take limited proteolysis into account in the search for detection of ubiquitinated peptides in proteomics studies. In conclusion, a simple method has been described allowing the identification of signature peptides, which are diagnostic markers of the majority of polyUb-conjugated proteins. In principle, the method should be applicable also for other more rare signature peptides.  相似文献   

19.
Mass spectrometers equipped with matrix‐assisted laser desorption/ionization (MALDI‐MS) require frequent multipoint calibration to obtain good mass accuracy over a wide mass range and across large numbers of samples. In this study, we introduce a new synthetic peptide mass calibration standard termed PAS‐cal tailored for MALDI‐MS based bottom‐up proteomics. This standard consists of 30 peptides between 8 and 37 amino acids long and each constructed to contain repetitive sequences of Pro, Ala and Ser as well as one C‐terminal arginine residue. MALDI spectra thus cover a mass range between 750 and 3200 m/z in MS mode and between 100 and 3200 m/z in MS/MS mode. Our results show that multipoint calibration of MS spectra using PAS‐cal peptides compares well to current commercial reagents for protein identification by PMF. Calibration of tandem mass spectra from LC‐MALDI experiments using the longest peptide, PAS‐cal37, resulted in smaller fragment ion mass errors, more matching fragment ions and more protein and peptide identifications compared to commercial standards, making the PAS‐cal standard generically useful for bottom‐up proteomics.  相似文献   

20.
Peptide hormones represent an emerging class of potential doping agents. Detection of their misuse is difficult due to their short half‐life in plasma and rapid elimination. Therefore, investigating their metabolism can improve detectability. Unfortunately, pharmacokinetic studies with human volunteers are often not allowed because of ethical constraints, and therefore alternative models are needed. This study was performed in order to evaluate in vitro models (human liver microsomes and S9 fraction) for the prediction of the metabolism of peptidic doping agents and to compare them with the established models. The peptides that were investigated include desmopressin, TB‐500, GHRP‐2, GHRP‐6, hexarelin, LHRH and leuprolide. Several metabolites were detected for each peptide after incubation with human liver microsomes, S9 fraction, and serum, which all showed endopeptidase and exopeptidase activity. In vitro models from different organs (liver vs. kidney) were compared, but no significant differences were recorded. Deamidation was not observed in any of the models and was therefore evaluated by incubation with α‐chymotrypsin. In conclusion, in vitro models are useful tools for forensic and clinical analysts to detect peptidic metabolic markers in biological fluids. Copyright © 2014 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号