首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The purpose of the study was to assess the effect of movement velocity on the relation between fluctuations in acceleration and the ability to achieve a target velocity during voluntary contractions performed by young (29.5 +/- 4.3 yr) and old (74.9 +/- 6.2 yr) adults. Subjects performed concentric and eccentric contractions with the first dorsal interosseus muscle while lifting a submaximal load (15% of maximum) at six movement velocities (0.03-1.16 rad/s). Fluctuations in acceleration, the accuracy of matching the target velocity, and electromyographic (EMG) activity were determined from three trials for each contraction type and movement velocity. The fluctuations in acceleration increased with movement velocity for both concentric and eccentric contractions, but they were greatest during fast eccentric contractions ( approximately 135%) when there was stronger modulation of acceleration in the 5- to 10-Hz bandwidth. Nonetheless, EMG amplitude for first dorsal interosseus increased with movement velocity only for concentric and not eccentric contractions. Consistent with the minimum variance theory, movement accuracy was related to the fluctuations in acceleration for both types of contractions in all subjects. For a given level of fluctuations in acceleration, however, old subjects were three times less accurate than young subjects. Although the EMG amplitude at each speed was similar for young and old adults, only the young adults modulated the power in the EMG spectrum with speed. Thus the fluctuations in acceleration during voluntary contractions had a more pronounced effect on movement accuracy for old adults compared with young adults, probably due to factors that influenced the frequency-domain characteristics of the EMG.  相似文献   

2.
The aim of the present study was to evaluate the viability of a relationship between the temporal activation pattern of parts of the erector spinae muscle and endurance. Seven subjects performed intermittent isometric contractions [4 s at 7007o maximal voluntary contraction (MVC), 2 s rest] until exhaustion, during which the electromyographical (EMG) activity of the multifidus, iliocostalis thoracis and longissimus muscle segments was recorded. Endurance was defined as the time until exhaustion. Subjects were divided into a high and a low endurance group. The high endurance group showed significantly more variability of EMG amplitude over succeeding contractions. This group demonstrated significantly more alternations of EMG activity between parts of the muscle also. Variability of the EMG amplitude within the contractions did not differ between the groups, nor did MVC. The results indicated that alternating activity between different parts of the erector spinae muscle may function to postpone exhaustion of this muscle as a whole.  相似文献   

3.
4.
The aim of this study was to analyze the effect of ischemia on low-threshold motor unit conduction velocity. Nine subjects were trained to isolate the activity of a single motor unit (target motor unit) in the abductor pollicis brevis muscle with feedback on surface EMG signals recorded with a 16-electrode linear array. After training, the subjects activated the target motor unit at approximately 8 pulses per second (pps) for five 3-min-long contractions. During the third and fourth contractions, a cuff inflated at 180 mmHg around the forearm induced ischemia of the hand. The exerted force (mean +/- SE, 4.6 +/- 2.1% of the maximal voluntary contraction force), discharge rate (8.6 +/- 0.4 pps), interpulse interval variability (34.8 +/- 2.5%), and peak-to-peak amplitude of the target motor unit action potentials (176.6 +/- 18.2 microV) were not different among the five contractions. Conduction velocity, mean power spectral frequency, and action potential duration were the same in the beginning of the five contractions (2.8 +/- 0.2 m/s, 195.2 +/- 10.5 Hz, and 5.4 +/- 0.3 ms, respectively) and changed over the 3 min of sustained activation only during the fourth contraction. Conduction velocity and mean power spectral frequency decreased (10.05 +/- 1.8% and 8.50 +/- 2.18% during the 3 min, respectively) and action potential duration increased (8.2 +/- 4.6% in the 3 min) during the fourth contraction. In conclusion, 1) subjects were able to isolate the activity of a single motor unit with surface EMG visual feedback in ischemic conditions maintained for 16 min, and 2) the activation-induced decrease in single motor unit conduction velocity was significantly larger with ischemia than with normal circulation, probably due to the alteration of mechanisms of ion exchange across the fiber membrane.  相似文献   

5.
To test the hypothesis that muscle sound amplitudes would remain constant during sustained submaximal isometric contractions, we recorded acoustic myograms from the abductor digiti minimi muscle in 12 subjects at 15, 25, 50, and 75% of a maximum voluntary contraction (MVC). Muscle sounds were detected with an omni-directional electret microphone encased in closed-cell foam and attached to the skin over the muscle. Acoustic amplitudes from the middle and end of the sustained contractions were compared with the amplitudes from the beginning of contractions to determine whether acoustic amplitudes varied in magnitude as force remained constant. Physiological tremor was eliminated from the acoustic signal by use of a Fourier truncation at 14 Hz. The amplitudes of the acoustic signal at a contraction intensity of 75% MVC remained constant, reflecting force production over time. At 50% MVC, the root-mean-square amplitude decreased from the beginning to the end of the contraction (P less than 0.05). Acoustic amplitudes increased over time at 15 and 25% MVC and were significantly higher at the end of the contractions than at the beginning (P less than 0.05). Alterations in the acoustic amplitude, which reflect changes in the lateral vibrations of the muscle, may be indicative of the different recruitment strategies used to maintain force during sustained isometric contractions.  相似文献   

6.
The interpretation of the electromyogram (EMG) of dynamic contractions might be difficult because the movement per se introduces additional factors that could affect its characteristics. There is a lack of studies concerning the reproducibility of surface EMG registrations during dynamic contractions. The aim was to investigate the during-the-day reproducibility (using intra-class correlation; ICC) of the peak torque (PT) and the EMG variables (without removing the electrodes) of dynamic contractions. Ten healthy subjects performed three sets of 10 dynamic maximum right-knee extensions with a one-hour interval in between, using an isokinetic dynamometer and the PT was determined. EMG signals were recorded from the right vastus lateralis, rectus femoris and vastus medialis muscles using surface electrodes and the mean frequency of the power spectrum (MNF [Hz]) and the signal amplitude (RMS [microV]), were computed. The ability to relax in-between the maximum extensions was calculated as a ratio of the RMS during the passive flexion phase and the RMS during the active extension phase of each contraction cycle: the signal amplitude ratio (SAR). Both PT (ICC = 0.99) and RMS (ICC = 0.83-0.98) had good reproducibility. The reproducibility of MNF was good for all muscles when the mean of contraction nos.: 1-10 was used. Vastus lateralis had the highest ICC among the three muscles. The reproducibility of SAR was generally poor (ICC < 0.60). The present study showed good reproducibility for common EMG variables (MNF and RMS) obtained during maximum isokinetic contractions.  相似文献   

7.
The development of fatigue and the relationship between psychological and physiological indices of fatigue were studied in a group of 18 male subjects during static contractions. Exercise was performed as a static elbow flexion at 25% MVC. Heart rate (HR), intraarterial blood pressure (BP) and surface EMG [mean amplitude (MA) and central frequency (CF)] were studied during contractions sustained until exhaustion. The amount of effort expended (relative to total exhaustion) and the rating of perceived pain were recorded following contractions interrupted after 20, 30 . . . 80, and 100% of endurance time. HR, BP and EMG amplitude responses were similar to those previously recorded. The decline in CF occurred in two phases, possibly related to a change in motor unit recruitment after the initial 70% of endurance time. The subjects overestimated the amount of effort expended and thus underestimated their endurance capacity. The best correlation between perceived effort and physiological responses was obtained using blood pressure data, whereas changes in EMG data did not parallel the psychological responses. It is concluded that the perception of effort during a static contraction is produced through a complex process, in which several influences of peripheral and central origin are integrated.  相似文献   

8.
The purpose of this study was to determine test-retest reliability for median frequency (MDF) and amplitude of surface EMG during sustained fatiguing contractions of the quadriceps. Twenty-two healthy subjects (11 males and 11 females) were tested on two days held one week apart. Surface EMG was recorded from rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) during sustained isometric contractions at 80% and 20% of maximal voluntary contraction (MVC) held to exhaustion. Quadriceps fatigue was described using four measures for both MDF and amplitude of EMG: initial, final, normalized final and slope. For both MDF and amplitude, the initial, final and normalized EMG showed moderate to high reliability for all three muscle groups at both contraction levels (ICC=0.59-0.88 for MDF; ICC=0.58-0.99 for amplitude). Slope of MDF and amplitude was associated with a large degree of variability and low ICCs for the 80% but not the 20% MVC. MDF and amplitude of EMG during sustained contractions of the quadriceps are reproducible; normalized final values of MDF and amplitude show better reliability than slope.  相似文献   

9.
Changes in the EMG power spectrum during static fatiguing contractions are often attributed to changes in muscle fibre action potential conduction velocity. Mathematical models of the EMG power spectrum, which have been empirically confirmed, predict that under certain conditions a distinct maximum occurs in the low-frequency part of the spectrum, indicating the dominant firing rate of the motor units. The present study investigated the influence of this firing rate peak on the spectral changes during a static fatiguing contraction at 50% of maximum EMG amplitude in the frontalis and corrugator supercilii muscles. An exponential decrease of the median frequency (MF) of the EMG power spectrum was observed when the firing rate peak was absent. When the firing rate peak was present, an exaggerated decrease of MF in the beginning of the contraction was found, which was associated with an increase in firing rate peak magnitude. In later stages of the contraction, a partial recovery of MF occurred, concomitant with a decrease in firing rate peak magnitude. The influence of the firing rate peak on MF was also investigated during nonfatiguing contractions of the frontalis muscle at 20, 40, 60, and 80% of maximum EMG amplitude. A curvilinear relationship between MF and contraction strength was found, whether firing rate peaks were present or absent. The presence of firing rate peaks, however, was associated with a decrease in MF which was inversely related to contraction strength, due to the inverse relationship between firing rate peak magnitude and contraction strength.  相似文献   

10.
The purpose of this study was to determine, for different back muscles, if the median frequency (MF) of the electromyographic (EMG) power spectrum changes according to the position of the time window during a 5 s step contraction. Twenty males with no known back problems were standing upright in a dynamometer allowing lower limb and pelvis stabilization. Trunk extension efforts were performed by pushing on a force platform positioned at the T4 level while the extension moment at L5/S1 was displayed as visual feedback. The EMG signals from four homologous back muscles (multifidus at L5, ilicostalis lumborum at L3, and longissimus at L1 and T10) were collected using active surface electrodes during two 5 s static step contractions performed at five force levels (10, 20, 40, 60 and 80% of the maximal voluntary contraction). The root mean square (RMS) and MF values of the EMG signals corresponding to three 250 ms time windows (beginning, middle and end of each step contraction) were computed. The RMS values of several back muscles increased from the first to the third time window for contractions performed at high force levels only. However, a concomitant decrease in the MF values was observed only for the left multifidus muscle. It was concluded that muscle fatigue does not generally manifest itself during 5 s step contractions through the EMG signal. However, it is recommended to use step contractions lasting less than 5 s and to choose a time window located in the first 1-3 s to completely eliminate the possible effects of fatigue.  相似文献   

11.
The time course of muscle fiber conduction velocity and surface myoelectric signal spectral (mean and median frequency of the power spectrum) and amplitude (average rectified and root-mean-square value) parameters was studied in 20 experiments on the tibialis anterior muscle of 10 healthy human subjects during sustained isometric voluntary or electrically elicited contractions. Voluntary contractions at 20% maximal voluntary contraction (MVC) and at 80% MVC with duration of 20 s were performed at the beginning of each experiment. Tetanic electrical stimulation was then applied to the main muscle motor point for 20 s with surface electrodes at five stimulation frequencies (20, 25, 30, 35, and 40 Hz). All subjects showed myoelectric manifestations of muscle fatigue consisting of negative trends of spectral variables and conduction velocity and positive trends of amplitude variables. The main findings of this work are 1) myoelectric signal variables obtained from electrically elicited contractions show fluctuations smaller than those observed in voluntary contractions, 2) spectral variables are more sensitive to fatigue than conduction velocity and the average rectified value is more sensitive to fatigue than the root-mean-square value, 3) conduction velocity is not the only physiological factor affecting spectral variables, and 4) contractions elicited at supramaximal stimulation and frequencies greater than 30 Hz demonstrate myoelectric manifestations of muscle fatigue greater than those observed at 80% MVC sustained for the same time.  相似文献   

12.
Continuous wavelet analysis was used to study the spectral characteristics of the m. vastus lateralis electromyographic activity in two I : rhythmic knee-joint extensions and cycling. Wavelet analysis of surface electromyograms (EMGs) recorded during cyclic contractions of the same muscle during the two types of movements showed differences in the pattern of changes in the timefrequency characteristics of the signal during a single cycle of movements with different loads, as well as differences in the slow variations of spectral characteristics related to the development of muscle fatigue during the tests. It was shown that, during cycling at low loads (the beginning of the test) the EMG activity peaked during the second half of the muscle contraction (the angle in the knee joint was ≈140°); the increase in the load at the end of the test led to a shift of the peak to the beginning of the active phase of movement, while the median frequency of the instant wavelet spectra during the muscle contraction remained almost unchanged. During knee-joint extension, the maximum EMG activity was observed at the very end of the active phase of movement for all loads, and the median frequency significantly increased with increasing angle at the knee joint. The long-term time course of the EMG intensity growth during these tests also differed, whereas the changes in the wavelet-spectrum median frequencies were practically the same: they increased during both tests.  相似文献   

13.
Endurance capacity of human vastus lateralis muscles was observed 24 h after hard exercise followed by either a carbohydrate-restricted or a carbohydrate-loaded diet (depletion and repletion conditions). In a control condition the subjects did no previous exercise and ate their normal diet. Each of these conditions was followed by an experimental protocol in which the five male subjects made a series of alternating 25-s static contractions of each leg at 50% maximal voluntary contraction until one leg failed to achieve the required force (Tlim). Glycogen concentration before the experimental protocol in both legs was significantly lower in the depletion than in the repletion condition. Muscle lactate and creatine phosphate concentrations were within normal limits before the static contractions. The number of contractions the repleted (12.7 +/- 2.2) and depleted (10.3 +/- 1.5) legs could sustain before Tlim were not different from each other, but both were 35% (P less than 0.05) fewer than the control (17.6 +/- 3.0). Surface electromyogram (EMG) amplitude was higher in depleted than in repleted or control muscles. At Tlim, EMG amplitude was maximal, creatine phosphate was 50-70% depleted, and lactate increased fourfold. Average glycogen utilization per contraction in both the repletion and depletion conditions was 5.8 mmol/kg dry wt, but postexercise lactate concentrations were lower in depleted (14.4 +/- 3.6 mmol/kg dry wt) than in repleted (43.2 +/- 7.4) muscles. The EMG frequency distribution shifted downward in all conditions during the experimental protocol and was independent of muscle lactate concentration.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
This paper focuses on methodological issues related to surface electromyographic (EMG) signal detection from the low back muscles. In particular, we analysed (1) the characteristics (in terms of propagating components) of the signals detected from these muscles; (2) the effect of electrode location on the variables extracted from surface EMG; (3) the effect of the inter-electrode distance (IED) on the same variables; (4) the possibility of assessing fatigue during high and very low force level contractions. To address these issues, we detected single differential surface EMG signals by arrays of eight electrodes from six locations on the two sides of the spine, at the levels of the first (L1), the second (L2), and the fifth (L5) lumbar vertebra. In total, 42 surface EMG channels were acquired at the same time during both high and low force, short and long duration contractions. The main results were: (1) signal quality is poor with predominance of non-travelling components; (2) as a consequence of point (1), in the majority of the cases it is not possible to reliably estimate muscle fiber conduction velocity; (3) despite the poor signal quality, it was possible to distinguish the fatigue properties of the investigated muscles and the fatigability at different contraction levels; (4) IED affects the sensitivity of surface EMG variables to electrode location and large IEDs are suggested when spectral and amplitude analysis is performed; (5) the sensitivity of surface EMG variables to changes in electrode location is on average larger than for other muscles with less complex architecture; (6) IED influences amplitude initial values and slopes, and spectral variable initial values; (7) normalized slopes for both amplitude and spectral variables are not affected by IED and, thus, are suggested for fatigue analysis at different postures or during movement, when IED may change in different conditions (in case of separated electrodes); (8) the surface EMG technique at the global level of amplitude and spectral analysis cannot be used to characterize fatigue properties of low back muscles during very low level, long duration contractions since in these cases the non-stable MU pool has a major influence on the EMG variables. These considerations clarify issues only partially investigated in past studies. The limitations indicated above are important and should be carefully discussed when presenting surface EMG results as a means for low back muscle assessment in clinical practice.  相似文献   

15.
In contraction of skeletal muscle a delay exists between the onset of electrical activity and measurable tension. This delay in electromechanical coupling has been stated to be between 30 and 100 ms. Thus, in rapid movements it may be possible for electromyographic (EMG) activity to have terminated before force can be detected. This study was designed to determine the dependence of the EMG-tension delay upon selected initial conditions at the time of muscle activation. The right forearms of 14 subjects were passively oscillated by a motor-driven dynamometer through flexion-extension cycles of 135 deg at an angular velocity of approximately equal to 0.5 rad/s. Upon presentation of a visual stimulus the subjects maximally contracted the relaxed elbow flexors during flexion, extension, and under isometric conditions. The muscle length at the time of the stimulus was the same in all three conditions. An on-line computer monitoring surface EMG (Biceps and Brachioradialis) and force calculated the electromechanical delay. The mean value for the delay under eccentric condition, 49.5 ms, was significantly different (p less than 0.05) from the delays during isometric (53.9 ms) and concentric activity (55.5 ms). It is suggested that the time required to stretch the series elastic component (SEC) represents the major portion of the measured delay and that during eccentric muscle activity the SEC is in a more favorable condition for rapid force development.  相似文献   

16.
The purpose of this study was to describe an electromyogram (EMG) pattern during a submaximal eccentric task in 7 subjects adapted to high-force chronic eccentric exercise and 6 subjects naive to eccentric exercise. The EMG in all subjects was quantified during identical submaximal (200 W) eccentric and concentric cycle ergometry tasks. The EMG of the eccentrically adapted subjects was decreased (p < 0.05) compared to the eccentrically naive subjects, in duration, amplitude, and intensity as evidenced by a decreased EMG during the pedal cycle. This decrease may be one component of the protective effect that results from progressively increasing repeated bouts of eccentric muscle work. Clients and patients transitioning to rigorous overload training should become adapted to high eccentric loads and forces to avoid injury and a potential delay in their strength and conditioning training regimens.  相似文献   

17.
Paraspinal electromyographic (EMG) activity was recorded bilaterally from three lumbar levels during 30-s isometric trunk extensions [40 and 80% of maximum voluntary contraction (MVC)] in 20 healthy men and 14 chronic low back pain patients in pain. EMG parameters indicating neuromuscular fatigue and contralateral imbalances in EMG root-mean-square amplitude and median frequency were analyzed. Patients in pain showed less fatigue than controls at both contraction levels and produced only 55% of their MVC. Patients in pain likely did not produce a "true" maximum effort. A low MVC estimate would mean lower absolute contraction levels and less neuromuscular fatigue, thus explaining lower scores in the patients. Contralateral root-mean-square amplitude imbalances were present in both categories of subjects although such imbalances, when averaged across lumbar levels, were significantly larger in patients. Median frequency imbalances were significantly larger in the patients, at segmental as well as across lumbar levels. These results suggest that the presence of pain in these patients caused a redistribution of the activation behavior between synergistic muscles of the lumbar back.  相似文献   

18.
The cardiac refractory period prevents the heart from tetanic activation that is typically used in noncardiac striated muscle tissue. To what extent the refractory period prevents successive action potentials to activate the excitation-contraction coupling process and contractile machinery at supra-physiological rates, such as those present during ventricular fibrillation, is unknown. Using multicellular trabeculae isolated from rat hearts, we studied amplitude and kinetics of contraction at rates well above the normal in vivo rat heart range. We show that even at twice the maximal heart rate of the rat, little or no mechanical instability is observed; twitch contractions are at steady state, albeit with an elevated active diastolic force. Although the amplitude of contraction increased within in vivo heart rates (positive force-frequency response), at frequencies beyond the maximal heart rate (10-30 Hz) a steady decline of contractile amplitude is observed. Not until 30 Hz do the majority of the isolated muscle preparations show mechanical alternans, where strong and weak beats alternate. Interestingly, unlike striated limb skeletal muscle, fusing of twitch contractions did not cause a continuous increase in peak force: at frequencies of 10 Hz and above, systolic force declines with relatively little elevation in diastolic force. Contractile kinetics continued to accelerate, from 1 Hz up to 30 Hz, whereas the relative speed of contraction and relaxation remained closely coupled, reflected by a singular linear relationship between the maximal and minimal derivative of force (dF/dt). We conclude that cardiac muscle can produce mechanically stable steady-state contractions at supra-physiological pacing rates, while these contractions continue to decline in amplitude and increase in diastolic force past maximal heart rate.  相似文献   

19.
Research examining the electromyographic (EMG) burst structure of rapid discrete limb movements has led to discordant findings concerning agonist burst duration. Some research has shown that duration varies as a function of movement speed while other research has shown burst constancy. Unfortunately, much of this research may be confounded by not carefully controlling movement termination accuracy and movement time (MT). Due to these potential problems, the present study was conducted to determine the effects of strict spatiotemporal constraints on EMG characteristics of a rapid elbow flexion-extension response under two movement extent conditions across five different MTs. Results revealed that a decreased MT was accompanied by a decreased agonist (biceps) burst duration and increased agonist burst amplitude. The burst duration and amplitude both increased as the movement extent increased with MT held constant. None of three current theoretical perspectives of rapid movement control (the impulse-timing model, the speed-control system hypothesis, or the speed-sensitive strategy) could fully account for these results. Instead, a control strategy was exhibited in which moving faster was accomplished by relative scaling of burst area via concomitant expansion of burst amplitude and compression of burst duration.  相似文献   

20.
Five men performed submaximal isometric, concentric or eccentric contractions until exhaustion with the left arm elbow flexors at respectively 50%, 40% and 40% of the prefatigued maximal voluntary contraction force (MVC). Subsequently, and at regular intervals, the surface electromyogram (EMG) during 30-s isometric test contractions at 40% of the prefatigued MVC and the muscle performance parameters (MVC and the endurance time of an isometric endurance test at 40% prefatigued MVC) were recorded. Large differences in the surface EMG response were found after isometric or concentric exercise on the one hand and eccentric exercise on the other. Eccentric exercise evoked in two of the three EMG parameters [the EMG amplitude (root mean square) and the rate of shift of the EMG mean power frequency (MPF)] the greatest (P less than 0.001) and longest lasting (up to 7 days) response. The EMG response after isometric or concentric exercise was smaller and of shorter duration (1-2 days). The third EMG parameter, the initial MPF, had already returned to its prefatigued value at the time of the first measurement, 0.75 h after exercise. The responses of EMG amplitude and of rate of MPF shift were similar to the responses observed in the muscle performance parameters (MVC and the endurance time). Complaints of muscle soreness were most frequent and severe after the eccentric contractions. Thus, eccentric exercise evoked the greatest and longest lasting response both in the surface EMG signal and in the muscle performance parameters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号