首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
BackgroundLeft-sided ablation, targeting left inferior AV nodal extensions, is thought to be necessary for success in a small proportion of atrioventricular nodal re-entrant tachycardia (AVNRT) ablations; however Indian data are scarce in this regard.MethodsConsecutive cases of AVNRT undergoing slow pathway ablation in a single centre over an 18-month period were retrospectively analyzed. Left-sided ablation at the posteroseptal mitral annulus was performed if right-sided ablation failed to abolish AVNRT.ResultsFrom January 2017 to June 2018, out of 215 consecutive supraventricular tachycardia (SVT) cases, 154 (71.6%) were AVNRT (47.1 ± 13.1 years, 46.1% male). Trans-septal ablation was required in 5 (3.2%) cases (mean age 48.8 ± 9.4 years; 4 female, 1 male); all with typical (slow-fast) form of AVNRT. Compared with cases needing only right-sided ablation, radiofrequency time (50.8 ± 16.9 vs. 9.9 ± 8.5 min; p = 0.005) and procedure time (166.0 ± 35.0 vs 79.6 ± 35.9 min; p = 0.004) were significantly longer for trans-septal cases, while baseline intervals and tachycardia cycle length were not significantly different. Junctional ectopy was seen in only 2 of the 5 cases during left-sided ablation, but acute success (non-inducibility) was obtained in 3 cases. There were no instances of AV block. Over mean follow-up of 12.2 ± 4.0 months, clinical recurrence of AVNRT occurred in one case, while others remained arrhythmia-free without medication.ConclusionLeft-sided ablation was required in a small proportion of AVNRT ablations. Trans-septal approach targeting the posteroseptal mitral annulus was safe and yielded good mid-term clinical success.  相似文献   

2.
Tricuspid annular PVCs constitute 8% of idiopathic PVCs and 5% of RV PVCs. Although a rare entity to encounter in routine clinical practice, it can be a prime culprit behind major arrhythmic burden in few individuals. Electroanatomic approach with sub tricuspid retrograde catheter technique can target those annular PVCs and decrease the arrhythmia burden to normal or near normal range. Although procedural approach for parahisian PVCs requires a close look to avoid injury to native conduction system, TA PVCs are a real challenge due to inherent catheter instability and contact issue in sub tricuspid retrograde approach.  相似文献   

3.
IntroductionIntraprocedural coronary angiography is recommeded in patients undergoing ablation in aortic cusps to assess the relation of catheter tip and coronary ostia. In this report, we present our experience in selective coronary angiography through the radiofrequency catheter during premature ventricular contraction (PVC) ablation.Methods and resultsWe prospectively recruited 43 consecutive patients who underwent PVC ablation in the aortic cusps between March 2018 and April 2021. We performed coronary angiography through the contact force (CF)-sensing ablation catheter at the ablation site. Successful ablation was achieved in 38 (88%) of patients. No technical problems occurred after the contrast injection and ablation parameters were within the normal values, without any change of impedance and CF-sensing values and neither electrogram signal quality after contrast injection. No complications occurred during the procedure, hospital stay, and during one-year follow-up (15.3 ± 3.1 months).ConclusionSelective coronary angiography through the CF-sensing ablation catheter to assess the relation between the ablation site and the coronary ostia is feasible and no minor or major complications occurred in our experience.  相似文献   

4.
Radio-frequency (RF) ablation is an accepted treatment for cardiac arrhythmias related to abnormal focal cardiac substrate. The penetration depth of the electrode into the endocardium affects lesion size, a critical determinant of success of RF ablation. We measured the relation between the mechanical compliance and the penetration depth of RF ablation catheter electrode at frequently ablated areas of the endocardium and examined the influence of time after death on mechanical properties of the tissue. We measured force versus time for eight insertion depths of the catheter electrode into full-thickness endocardial samples derived from the mitral valve annulus, the left ventricular free wall and the tricuspid valve annulus. We varied the time after death at 15, 40 min, 3, 8, and 18 h and repeated our measurements. At 15 min after death, the first 0.5 mm penetration depth caused the fastest relaxation at 55 s. Force decay decreased dramatically at 15 min after death as the penetration depth increased from 0.5 to 4 mm. We used the force data sampled at 60 s after insertion to approximate the elasticity. We observed the relations between the force versus the insertion depth. The force increased by a factor of 5 for the mitral valve annulus and 8 for the left free wall from 15 min to 18 h. We derived coefficients of a second-order polynomial equation relating the force data to insertion depth with R2>0.99.  相似文献   

5.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

6.
Mitral annular (MA) and leaflet three-dimensional (3-D) dynamics were examined after circumferential phenol ablation of the MA and anterior mitral leaflet (AML) muscle. Radiopaque markers were sutured to the left ventricle, MA, and both mitral leaflets in 18 sheep. In 10 sheep, phenol was applied circumferentially to the atrial surface of the mitral annulus and the hinge region of the AML, whereas 8 sheep served as controls. Animals were studied with biplane video fluoroscopy for computation of 3-D mitral annular area (MAA) and leaflet shape. MAA contraction (MAACont) was determined from maximum to minimum value. Presystolic MAA (PS-MAACont) reduction was calculated as the percentage of total reduction occurring before end diastole. Phenol ablation decreased PS-MAACont (72 +/- 6 vs. 47 +/- 31%, P = 0.04) and delayed valve closure (31 +/- 11 vs. 57 +/- 25 ms, P = 0.017). In control, the AML had a compound sigmoid shape; after phenol, this shape was entirely concave to the atrium during valve closure. These data indicate that myocardial fibers on the atrial side of the valve influence the 3-D dynamic geometry and shape of the MA and AML.  相似文献   

7.

Introduction

The transcatheter mitral valve repair (TMVR) technique utilizes a stent to cinch a segment of the mitral annulus (MA) and reduces mitral regurgitation. The cinching mechanism results in reduction of the septal–lateral distance. However, the mechanism has not been characterized completely. In this study, a method was developed to quantify the relation between cinching tension and MA area in an ex vivo ovine model.

Method

The cinching tension was measured from a suture inserted within the coronary sinus (CS) vessel with one end tied to the distal end of the vessel and the other end exited to the CS ostium where it was attached to a force transducer on a linear stage. The cinching tension, MA area, septal–lateral (S–L) and commissure–commissure (C–C) diameters and leakage was simultaneously measured in normal and dilated condition, under a hydrostatic left ventricular pressure of 90 mmHg.

Results

The MA area was increased up to 22.8% after MA dilation. A mean tension of 2.1±0.5 N reduced the MA area by 21.3±5.6% and S–L diameter by 24.2±5.3%. Thus, leakage was improved by 51.7±16.2% following restoration of normal MA geometry.

Conclusion

The cinching tension generated by the suture acts as a compensation force in MA reduction, implying the maximum tension needed to be generated by annuloplasty device to restore normal annular size. The relationship between cinching tension and the corresponding MA geometry will contribute to the development of future TMVR devices and understanding of myocardial contraction function.  相似文献   

8.
Premature Ventricular Contraction (PVC)/ventricular tachycardia (VT) with left bundle branch block (LBBB) morphology and inferior axis has been described classically to originate from the right ventricular outflow tract (RVOT). Some uncommon sites of idiopathic ventricular arrhythmia (VA) origins have been revealed including tricuspid annulus (TA) and right ventricular (RV) inflow free wall region. We present a series of two cases who have undergone electrophysiological study and successful radiofrequency ablation of frequent monomorphic PVCs with LBBB pattern originating from relatively uncommon sites of RV – TA and RV inflow free wall region.  相似文献   

9.
Introduction– Local impedance (LI) guided ablation as a method of judging lesion effectiveness for cavotricuspid isthmus dependent atrial flutter (CTI-AFL), and ultra-high density (UHD) mapping when breakthrough occurred across an ablation line has not previously been assessed.MethodsThis retrospective observational study evaluated patients undergoing CTI-AFL ablation using conventional, contact force (CF) and LI guided strategies. Ablation metrics were collected, and in the LI cohort, the use of UHD mapping for breakthrough evaluated.Results30 patients were included, 10 per group. Mean total ablation time was significantly shorter with LI (3.2 ± 1.3min) vs conventional (5.6 ± 2.7min) and CF (5.7 ± 2.0min, p = 0.0042). Time from start of ablation to CTI block was numerically shorter with LI (14.2 ± 8.0min) vs conventional and CF (19.7 ± 14.1 and 22.5 ± 19.1min, p = 0.4408). Mean lesion duration was significantly shorter with LI, but there were no differences in the number of lesions required to achieve block, procedural success, complication rates or recurrence. 15/30 patients did not achieve block following first-pass ablation. UHD mapping rapidly identified breakthrough in the five LI patients, including epicardial-endocardial breakthrough (EEB).Conclusion– The use of LI during ablation for real-time lesion assessment was as efficacious as the conventional and CF methods. UHD mapping rapidly identified breakthrough, including EEB.  相似文献   

10.
Atrial flutter (AFL) is a common arrhythmia in clinical practice. Several experimental models such as tricuspid regurgitation model, tricuspid ring model, sterile pericarditis model and atrial crush injury model have provided important information about reentrant circuit and can test the effect of antiarrhythmic drugs. Human atrial flutter has typical and atypical forms. Typical atrial flutter rotates around tricuspid annulus and uses the crista terminalis and sometimes sinus venosa as the boundary. The IVC-tricuspid isthmus is a slow conduction zone and the target of radiofrequency ablation. Atypical atrial flutter may arise from the right or left atrium. Right atrial flutter includes upper loop reentry, free wall reentry and figure of eight reentry. Left atrial flutter includes mitral annular atrial flutter, pulmonary vein-related atrial flutter and left septal atrial flutter. Radiofrequency ablation of the isthmus between the boundaries can eliminate these arrhythmias.  相似文献   

11.
BackgroundFurther in-vivo evidence is needed to support the usefulness of ablation index (AI) in guiding atrial fibrillation (AF) ablation. We aimed at evaluating the relationship between AI and other lesion indicators and the release of myocardial-specific biomarkers following radiofrequency AF ablation.MethodsForty-six patients underwent a first-time radiofrequency AF ablation and were prospectively enrolled in this study. Pulmonary vein isolation was performed by six experienced electrophysiologists with a point-by-point approach, guided by strict Visitag criteria and consistent AI target values. Myocardial-specific biomarkers troponin T and creatine kinase myocardial band were measured after 6 (TnT6 and CKMB6) and 20 h (TnT20 and CKMB20) following sheath removal. Ablation duration, impedance drop (ID), force-time integral (FTI) and AI were registered automatically and analyzed offline.ResultsTnT release was 985 ± 495 ng/L and 1038 ± 461 ng/L (p = ns) while CKMB release was 7.3 ± 2.7 μg/L and 6.5 ± 2.1 μg/L (p < 0.001) at 6 and 20 h respectively. Ablation duration, ID, FTI and AI were all significantly correlated with the release of myocardial-specific biomarkers both at 6 and 20 h. Ablation index showed the highest degree of correlation with TnT6, TnT20, CKMB6 and CKMB20 (Pearson's R 0.69, 0.69, 0.61, 0.64 respectively, p < 0.001). Multiple regression analysis demonstrated that AI had the strongest association with TnT6, TnT20, CKMB6 and CKMB20 (β 0.43, β 0.71, β 0.44 and β 0.43 respectively).ConclusionAblation index appears as the strongest lesion indicator as measured by the release of myocardial-specific biomarkers following radiofrequency catheter ablation for AF.  相似文献   

12.
Much of our understanding of the mechanisms of macro re-entrant atrial tachycardia comes from study of cavotricuspid isthmus (CTI) dependent atrial flutter. In the majority of cases, the diagnosis can be made from simple analysis of the surface ECG. Endocardial mapping during tachycardia allows confirmation of the macro re-entrant circuit within the right atrium while, at the same time, permitting curative catheter ablation targeting the critical isthmus of tissue located between the tricuspid annulus and the inferior vena cava. The procedure is short, safe and by demonstration of an electrophysiological endpoint - bidirectional conduction block across the CTI - is associated with an excellent outcome following ablation. It is now fair to say that catheter ablation should be considered as a first line therapy for patients with documented CTI-dependent atrial flutter.  相似文献   

13.
BackgroundCatheter ablation provides curative treatment for tachyarrhythmias. Fluoroscopy, the method used for this, presents several risks. The electroanatomical mapping (MEA) presents a three-dimensional image without using X-rays, and may be adjunct to fluoroscopy.ObjectivesWe evaluated the possibility of performing catheter ablation with the exclusive use of electroanatomical mapping (MEA), dispensing with fluoroscopy. We compared the total time of procedure and success rates against the technique using fluoroscopy (RX) with emission of X-rays.MethodsRandomized, unicentric, uni-blind study of patients referred for tachyarrhythmia ablation.ResultsTwelve patients were randomized to the XR group and 11 to the EAM group. The mean age was 48.5 (±12.6) vs 46.3 (±16.6) (P = ns). Success occurred in 11 patients (91.7%) in the RX group and 9 (81.8%) in the MEA group (P = 0.46). The procedure time in minutes was higher in the MEA group than in the RX group (79-47-125min vs 49-30-100min; P = 0.006). The mean fluoroscopy time was 11 ± 9 min versus zero (RX vs MEA: P < 0.001). The mean radiofrequency applications were lower in the RX group against the MEA group (6 ± 3.5 × 13.2 ± 18.2 p < 0.019). There were no complications.ConclusionMEA opened new therapeutic possibilities for patients with arrhythmias, reducing the risk of radiation. In this study, it was possible to demonstrate that it is feasible to perform ablation only with the use of MEA, with similar success with fluoroscopy, at the expense of a longer procedure time.  相似文献   

14.
A 74-year-old man after multiple mitral valve surgeries underwent catheter ablation of a bi-atrial tachycardia (BiAT). Ultra-high resolution activation mapping exhibited a reentrant circuit propagating around the inferior to anterior mitral annulus and right atrial (RA) septum with two interatrial connections. At the transeptal puncture site, continuous fractionated electrograms were recorded during the BiAT, and entrainment pacing revealed a post-pacing interval similar to the tachycardia cycle length, which suggested that the interatrial conduction from the RA to the left atrium (LA) was located just at the transseptal puncture site. A radiofrequency application inside the transseptal puncture hole could successfully eliminate the BiAT. The ablation target for BiATs propagating around the mitral annulus and RA septum is generally the anatomical mitral isthmus (MI). Since the present case had multiple incisions on both the RA and LA septum due to mitral valve surgeries, there was the possibility of the occurrence of a BiAT including the RA and LA septum after performing an MI linear ablation. Therefore, the preferable ablation target for the BiAT in the present case appeared to be the interatrial connection. Ultra-high resolution detailed mapping not only on the atrial endocardium but also in the transseptal puncture hole may be useful for identifying a critical interatrial connection of BiAT circuits.  相似文献   

15.
IntroductionMechanical suppression of premature ventricular complexes (PVCs) is not a well-known observation. We retrospectively reviewed this phenomenon in the Ventricular Arrhythmia (VA) ablation procedures performed at Richard L. Roudebush Veterans Health Administration (VHA) center.MethodsData from 40 consecutive patients who underwent VA ablation at VHA, Indianapolis, IN, with 44 VA was included in the study. Demographic and electrophysiological parameter data was collected.ResultsOverall the mean age of the population was 64 ± 11 years. The phenomenon of mechanical suppression was seen in 11 PVCs. The mean age was 59 ± 15 years in the group in which mechanical suppression was seen. Of the 11 cases, the site of earliest activation was seen in the coronary sinus in 8 and in the pulmonary artery in 3. In one case catheter ablation was not performed because of proximity to the left coronary artery system. However, sustained pressure at the site with earliest electrograms (?35 ms) and 95% pacematch resulted in long-term suppression of PVCs. In the cases in which mechanical suppression was seen, there was a statistically significant reduction in PVC burden compared to pre ablation PVC load (1.1% ± 1.50% (post ablation) versus 24.04% ± 13.07% (pre ablation) versus p < 0.05).In all the 11 cases the site of mechanical suppression was also the site with earliest electrograms.ConclusionThis case series illustrates phenomenon of mechanical suppression of PVCs as an indication for good site for successful ablation in unique veteran patient population.  相似文献   

16.
Catheter instability can limit ablation success of arrhythmia substrates at the right atrioventricular groove. We describe cases where cryoablation improved catheter stability, enabling ablation success.Methods and resultsFour patients with supraventricular tachycardia (SVT) substrates at the right atrioventricular groove had radiofrequency ablation procedures limited by poor catheter contact. Cryoablation offered improved catheter stability, and all four patients achieved acute ablation success using cryoablation. Three patients had long-term success and one patient later required repeat radiofrequency ablation.ConclusionsFor patients with arrhythmia substrates at the right atrioventricular groove, cryoablation may be a useful adjunctive technique in cases with catheter instability.  相似文献   

17.
BackgroundOesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction.Methods180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B).ResultsAblation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01).ConclusionsOE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.  相似文献   

18.
PurposeElectroanatomical mapping (EAM) could increase cardiac magnetic resonance imaging (CMR) sensitivity in detecting ventricular scar. Possible bias may be scar over-estimation due to inadequate tissue contact. Aim of the study is to evaluate contact-force monitoring influence during EAM, in patients with idiopathic right ventricular arrhythmias.Methods20 pts (13 M; 43 ± 12 y) with idiopathic right ventricular outflow tract (RVOT) arrhythmias and no structural abnormalities were submitted to Smarttouch catheter Carto3 EAM. Native maps included points collected without considering contact-force. EAM scar was defined as area ≥1 cm2 including at least 3 adjacent points with signal amplitude (bipolar <0.5 mV, unipolar 3,5 mV), surrounded by low-voltage border zone. EAM were re-evaluated offline, removing points collected with contact force <5 g. Finally, contact force-corrected maps were compared to the native ones.ResultsAn EAM was created for each patient (345 ± 85 points). After removing poor contact points, a mean of 149 ± 60 points was collected. The percentage of false scar, collected during contact force blinded mapping compared to total volume, was 6.0 ± 5.2% for bipolar scar and 7.1 ± 5.9% for unipolar scar, respectively. No EAM scar was present after poor contact points removal. Right ventricular areas analysis revealed a greater number of points with contact force < 5 g acquired in free wall, where reduced mean bipolar and unipolar voltage were recorded.ConclusionsTo date this is the first work conducted on structurally normal hearts in which contact-force significantly increases EAM accuracy, avoiding “false scar” related to non-adequate contact between catheter and tissue.  相似文献   

19.
Annuloplasty ring repair is a common procedure for the correction of mitral valve regurgitation. Commercially available rings vary in dimensions and material properties. Annuloplasty ring suture dehiscence from the native annulus is a catastrophic yet poorly understood phenomenon that has been reported across ring types. Recognizing that sutures typically dehisce from the structurally weaker posterior annulus, our group is conducting a multi-part study in search of ring design parameters that influence forces acting on posterior annular sutures in the beating heart. Herein, we report the effect of ring rigidity on suture forces. Measurements utilized custom force sensors, attached to annuloplasty rings and implanted in normal ovine subjects via standard surgical procedure. Tested rings included the semi-rigid Physio (Edwards Lifesciences) and rigid and flexible prototypes of matching geometry. While no significant differences due to ring stiffness existed for sutures in the anterior region, posterior forces were significantly reduced with use of the flexible ring (rigid: 1.95 ± 0.96 N, semi-rigid: 1.76 ± 1.19 N, flexible: 1.04 ± 0.63 N; p < 0.001). The ratio of anterior to posterior FC scaled positively with increasing flexibility (p < 0.001), and posterior forces took more time to reach their peak load when a flexible ring was used (p < 0.001). This suggests a more rigid ring enables more rapid/complete force equilibration around the suture network, transferring higher anterior forces to the weaker posterior tissue. For mitral annuloplasties requiring ring rigidity, we propose a ring design concept to potentially disrupt this force transfer and improve suture retention.  相似文献   

20.

Background

Radiofrequency catheter ablation of atrial fibrillation (AF) has been proved to be effective and to prevent progressive left atrial (LA) remodeling. Cryoballoon catheter ablation (CCA), using a different energy source, was developed to simplify the ablation procedure. Our hypothesis was that successful CCA can also prevent progressive LA remodeling.

Methods

36 patients selected for their first CCA because of nonvalvular paroxysmal AF had echocardiography before and 3, 6 and 12 months after CCA. LA diameters, volumes (LAV) and LA volume index (LAVI) were evaluated. LA function was assessed by: early diastolic velocities of the mitral annulus (Aasept, Aalat), LA filling fraction (LAFF), LA emptying fraction (LAEF) and the systolic fraction of pulmonary venous flow (PVSF). Detailed left ventricular diastolic function assessment was also performed.

Results

Excluding recurrences in the first 3-month blanking period, the clinical success rate was 64%. During one-year of follow-up, recurrent atrial arrhythmia was found in 21 patients (58%). In the recurrent group at 12 months after ablation, minimal LAV (38 ± 19 to 44 ± 20 ml; p < 0.05), maximal LAV (73 ± 23 to 81 ± 24 ml; p < 0.05), LAVI (35 ± 10 to 39 ± 11 ml/m2; p = 0.01) and the maximal LA longitudinal diameter (55 ± 5 to 59 ± 6 mm; p < 0.01) had all increased. PVSF (58 ± 9 to 50 ± 10%; p = 0.01) and LAFF (36 ± 7 to 33 ± 8%; p = 0.03) had decreased. In contrast, after successful cryoballoon ablation LA size had not increased and LA function had not declined. In the recurrent group LAEF was significantly lower at baseline and at follow-up visits.

Conclusions

In patients whose paroxysmal atrial fibrillation recurred within one year after cryoballoon catheter ablation left atrial size had increased and left atrial function had declined. In contrast, successful cryoballoon catheter ablation prevented progressive left atrial remodeling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号