首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
The purpose of this study was to quantify the impact of inter-fraction modifications of bladder during RT of prostate cancer on bladder dose surface maps (DSM).Eighteen patients treated with daily image-guided Tomotherapy and moderate hypofractionation (70–72.8 Gy at 2.5–2.6 Gy/fr in 28 fractions and full bladder) were considered. Bladder contours were delineated on co-registered daily Megavoltage CT (MVCT) by a single observer and copied on the planning CT to generate dose–volume/surface histograms (DVH/DSH) and bladder DSMs. Discrepancies between planned and daily absorbed doses were analyzed through the average of individual systematic errors, the population systematic errors and the population random errors for the DVH/DSHs and DSMs.In total, 477 DVH/DSH and 472 DSM were available. DSH and DVH showed small population systematic errors of absolute surfaces (<3.4 cm2) and volumes (<8.4 cm3) at the highest doses.The dose to the posterior bladder base assessed on DSMs showed a mean systematic error below 1 Gy, with population systematic and random errors within 4 and 3 Gy, respectively. The region surrounding this area shows higher mean systematic errors (1–3 Gy), population systematic (8–11 Gy) and random (5–7 Gy) errors.In conclusion, DVH/DSH and DSMs are quite stable with respect to inter-fraction variations in the high-dose region, within about 2 cm from bladder base. Larger systematic variations occur in the anterior portion and cranially 2.5–3.5 cm from the base.Results suggest that dose predictors related to the high dose area (including the trigone dose) are likely to be sufficiently reliable with respect to the expected variations due to variable bladder filling.  相似文献   

2.
Chaotic dynamics introduced in a recurrent neural network model is applied to controlling an object to track a moving target in two-dimensional space, which is set as an ill-posed problem. The motion increments of the object are determined by a group of motion functions calculated in real time with firing states of the neurons in the network. Several cyclic memory attractors that correspond to several simple motions of the object in two-dimensional space are embedded. Chaotic dynamics introduced in the network causes corresponding complex motions of the object in two-dimensional space. Adaptively real-time switching of control parameter results in constrained chaos (chaotic itinerancy) in the state space of the network and enables the object to track a moving target along a certain trajectory successfully. The performance of tracking is evaluated by calculating the success rate over 100 trials with respect to nine kinds of trajectories along which the target moves respectively. Computer experiments show that chaotic dynamics is useful to track a moving target. To understand the relations between these cases and chaotic dynamics, dynamical structure of chaotic dynamics is investigated from dynamical viewpoint.  相似文献   

3.
    
PurposeTo propose a geometrical margin for definition of the vaginal cuff PTV using only CT images of the full bladder (CTfull) in postoperative cervical cancer patients.MethodsTwenty-nine operated cervical cancer patients underwent volumetric arc therapy with a bladder filling protocol. This study assessed bladder filling using a portable bladder scanner and cone-beam computed tomography (CBCT) during the entire treatment period. The measured bladder volumes with a BladderScan® were compared with the delineated volume on CBCT. Titanium clips in the vaginal cuff were analysed to assess geometrical uncertainty and the influence of rectal and bladder volume changes.ResultsBladderScan® showed good agreement with the delineated volume (R = 0.80). The volume changes in the bladder have a greater influence on the clip displacements than in the rectum. The 95th percentile of uncertainty of the clips in reference to CTfull in the right-left (RL), the superoinferior (SI), and the anteroposterior (AP) was 0.32, 0.65, and 1.15 cm, respectively. From this result and intra-fractional movements of the vaginal cuff reported by Haripotepornkul, a new geometrical margin was proposed for definition of the vaginal cuff planning target volume (PTV): 0.5, 0.9, and 1.4 cm in the RL, SI, and AP directions, respectively.ConclusionsA new geometrical margin was proposed for definition of the vaginal cuff PTV based on CTfull, which will be needless of empty bladder at the planning CT scan. This method allows patients to reduce the burden and efficient routine CT scans can be improved.  相似文献   

4.
5.
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation Therapy (SBRT) in prostate cancer management. In this context, the medical physicists are regularly involved to review the appropriateness of the adopted technology and to proactively study new solutions. From the physics point of view there are two major challenges in prostate SBRT: (1) mitigation of geometrical uncertainty and (2) generation of highly conformal dose distributions that maximally spare the OARs. Geometrical uncertainties have to be limited as much as possible in order to avoid the use of large PTV margins. Furthermore, advanced planning and delivery techniques are needed to generate maximally conformal dose distributions. In this non-systematic review the technology and the physics aspects of SBRT for prostate cancer were analyzed. In details, the aims were: (i) to describe the rationale of reducing the number of fractions (i.e. increasing the dose per fraction), (ii) to analyze the features to be accounted for performing an extreme hypo-fractionation scheme (>6–7 Gy), and (iii) to describe technological solutions for treating in a safe way. The analysis of outcomes, toxicities, and other clinical aspects are not object of the present evaluation.  相似文献   

6.
    
We review a case of inoperable early stage breast cancer treated definitively with the use of stereotactic ablative radiotherapy (SABR). A 57-year-old female with a history of decompensated cirrhosis with early stage breast cancer was treated with 25 Gy in one fraction. At her 7-month follow up visit, there was a complete resolution of disease on imaging. This case represents a novel approach for the treatment of breast cancer with SABR when surgery is contraindicated.  相似文献   

7.
AimTo analyze the literature data about lung oligometastatic patients who underwent SBRT with regard to doses, fractionation, outcomes, response assessment and prognostic factors, trying to define “the right patient” for the local treatment.Background“Oligometastatic disease” is defined as a state in which metastases are limited in number and site and characterized by unusual cancer biology and behavior. In this setting local therapy could have a potential curative role. Recently, technological advances in Radiation Oncology permitted the introduction of Stereotactic Body Radiation Therapy (SBRT), a novel treatment modality that delivers ablative dose of radiation to the extra-cranial sites with high precision using single or a small number of fractions.Materials and methodsWe performed a literature search using Medical Subject Heading terms “stereotactic body radiation therapy” and “lung metastases”, considering a period of 10 years.ResultsMany non-randomized studies have shown that SBRT for lung oligometastases is safe and effective, with local control rates of about 80%. To date SBRT represents an alternative and competitive option in patients with lung oligometastatic disease who refuse surgical treatment or unsuitable for surgery. Based on published studies, SBRT might have major benefit for a patient with breast histology, disease-free interval ≥12 months, control of the primary tumor, small lesions, limited number of lesions and higher radiation dose delivered.ConclusionsWell-designed collaborative trials are necessary to draw final conclusions. To date, the discussion within a multidisciplinary team becomes crucial to perform a careful patients’ selection in the setting of oligometastatic disease.  相似文献   

8.
    
AimThis study reports a single-institutional experience treating liver metastases with stereotactic body radiation therapy (SBRT).Materials and methods107 patients with 169 lesions were assessed to determine factors predictive for local control, radiographic response, and overall survival (OS). Machine learning techniques, univariate analysis, and the Kaplan-Meier method were utilized.ResultsPatients were treated with a relatively low median dose of 30 Gy in 3 fractions. Fractions were generally delivered once weekly. Median biologically effective dose (BED) was 60 Gy, and the median gross tumor volume (GTV) was 12.16 cc. Median follow-up was 7.36 months. 1-year local control was 75% via the Kaplan-Meier method. On follow-up imaging, 43%, 40%, and 17% of lesions were decreased, stable, and increased in size, respectively. 1-year OS was 46% and varied by primary tumor, with median OS of 34.3, 25.1, 12.5, and 4.6 months for ovarian, breast, colorectal, and lung primary tumors, respectively. Breast and ovarian primary patients had better OS (p < 0.0001), and lung primary patients had worse OS (p = 0.032). Higher BED values, the number of hepatic lesions, and larger GTV were not predictive of local control, radiographic response, or OS. 21% of patients suffered from treatment toxicity, but no grade ≥3 toxicity was reported.ConclusionRelatively low-dose SBRT for liver metastases demonstrated efficacy and minimal toxicity, even for patients with large tumors or multiple lesions. This approach may be useful for patients in whom higher-dose therapy is contraindicated or associated with high risk for toxicity. OS depends largely on the primary tumor.  相似文献   

9.
    
The design, production and adaptability to clinical routine of a patient-specific tumor and respiratory monitoring phantom (TRMP) was investigated using 3D printer technology. TRMP and GTV modelling were done using 4D-CT images of the inhalation phase. The model was converted to STL (Stereolithography) format and printed with STH (Strong Herbal) biopolymer with HU (Hounsfield Unit) suitable for imaging purposes. The assembly of TRMP motorized parts and mechanical equipment has been completed and made suitable for clinical use. In the first part of the study, the deviations of radio-opaque markers attached to the TRMP sternum to perform mechanical quality control tests and T1-7 costal vertebrae in CC, AP, and LAT directions were evaluated. In the second part of the study, in order to evaluate the usability of the TRMP in quality assurance (QA), point dose measurements with BeO OSL dosimetry and EBT3 gafchromic film measurements were taken in Trilogy® radiotherapy accelerator and CyberKnife® robotic radiosurgery accelerator. In this study, we present a highly flexible TMRP capable of performing independent internal and external motions. TRMP was successfully tested in different treatment accelerators, both mechanically and dosimetrically.  相似文献   

10.
11.
    
Stereotactic body radiation therapy (SBRT) has become a standard treatment for non-operable patients with early stage non-small cell lung cancer (NSCLC). In this context, medical physics community has largely helped in the starting and the growth of this technique. In fact, SBRT requires the convergence of many different features for delivering large doses in few fractions to small moving target in an heterogeneous medium. The special issue of last month, was focused on the different physics challenges in lung SBRT. Eleven reviews were presented, covering: imaging for treatment planning and for treatment assessment; dosimetry and planning optimization; treatment delivery possibilities; image guidance during delivery; radiobiology. The current cutting edge role of medical physics was reported. We aimed to give a complete overview of different aspects of lung SBRT that would be of interest to both physicists implementing this technique in their institutions and more experienced physicists that would be inspired to start research projects in areas that still need further developments. We also feel that the role that medical physicists have played in the development and safe implementation of SBRT, particularly in lung region, can be taken as an excellent example to be translated to other areas, not only in Radiation Oncology but also in other health sectors.  相似文献   

12.
We examined object permanence in black‐and‐white‐ruffed lemurs (Varecia variegata) at Zoo Atlanta. A series of visible and invisible displacement tasks with suitable controls were presented to five adult subjects. Subjects performed significantly above chance on all regular tasks, except for the double invisible displacements. Subjects failed visible and invisible controls. Failure on the control trials did not appear to be because subjects used the “last box touched” strategy (subjects did not choose the last box touched significantly more than expected by chance). However, a substantial percentage of choices was made to the last box touched by the experimenter. There was no significant difference between this percentage, and the percentage of choices made to the baited box (on both visible and invisible controls), which indicates that subjects were drawn to both boxes which the experimenter visited/touched, and thus failed the controls. Based on the results from the present study, we believe that there is no evidence that black‐and‐white ruffed lemurs understand visible and invisible tasks in the traditional object permanence battery. Am. J. Primatol. 75:376‐386, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

13.
14.
    
AimThis study aimed to evaluate the dosimetric impact of uncorrected yaw rotational error on both target coverage and OAR dose metrics in this patient population.BackgroundRotational set up errors can be difficult to correct in lung VMAT SABR treatments, and may lead to a change in planned dose distributions.Materials and methodsWe retrospectively applied systematic yaw rotational errors in 1° degree increments up to −5° and +5° degrees in 16 VMAT SABR plans. The impact on PTV and OARs (oesophagus, spinal canal, heart, airway, chest wall, brachial plexus, lung) was evaluated using a variety of dose metrics. Changes were assessed in relation to percentage deviation from approved planned dose at 0 degrees.ResultsTarget coverage was largely unaffected with the largest mean and maximum percentage difference being 1.4% and 6% respectively to PTV D98% at +5 degrees yaw.Impact on OARs was varied. Minimal impact was observed in oesophagus, spinal canal, chest wall or lung dose metrics. Larger variations were observed in the heart, airway and brachial plexus. The largest mean and maximum percentage differences being 20.77% and 311% respectively at −5 degrees yaw to airway D0.1cc, however, the clinical impact was negligible as these variations were observed in metrics with minimal initial doses.ConclusionsNo clinically unacceptable changes to dose metrics were observed in this patient cohort but large percentage deviations from approved dose metrics in OARs were noted. OARs with associated PRV structures appear more robust to uncorrected rotational error.  相似文献   

15.
    
PurposeEvaluating performance of modern dose calculation algorithms in SBRT and locally advanced lung cancer radiotherapy in free breathing (FB) and deep inspiration breath hold (DIBH).MethodsFor 17 patients with early stage and 17 with locally advanced lung cancer, a plan in FB and in DIBH were generated with Anisotropic Analytical Algorithm (AAA). Plans for early stage were 3D-conformal SBRT, 45 Gy in 3 fractions, prescribed to 95% isodose covering 95% of PTV and aiming for 140% dose centrally in the tumour. Locally advanced plans were volumetric modulated arc therapy, 66 Gy in 33 fractions, prescribed to mean PTV dose. Calculation grid size was 1 mm for SBRT and 2.5 mm for locally advanced plans. All plans were recalculated with AcurosXB with same MU as in AAA, for comparison on target coverage and dose to risk organs.ResultsLung volume increased in DIBH, resulting in decreased lung density (6% for early and 13% for locally-advanced group).In SBRT, AAA overestimated mean and near-minimum PTV dose (p-values < 0.01) compared to AcurosXB, with largest impact in DIBH (differences of up to 11 Gy). These clinically relevant differences may be a combination of small targets and large dose gradients within the PTV.In locally advanced group, AAA overestimated mean GTV, CTV and PTV doses by median less than 0.8 Gy and near-minimum doses by median 0.4–2.7 Gy.No clinically meaningful difference was observed for lung and heart dose metrics between the algorithms, for both FB and DIBH.ConclusionsAAA overestimated target coverage compared to AcurosXB, especially in DIBH for SBRT.  相似文献   

16.
    
BackgroundStaple line (SL) recurrences of non-small cell lung cancer (NSCLC) are commonly treated with radiotherapy (RT), but the target volume definition — whole SL versus focused on recurrence — is unclear. The aim of the study was to determine the appropriate target volume for RT of SL recurrences.Materials and methodsTwenty-two consecutive patients (20 stage I, 2 stage II) treated with salvage RT for SL recurrences were retrospectively analyzed. Imaging features at the time of SL recurrence were evaluated to guide target volume definition.ResultsSurgeryAll patients had complete tumor resection (wedge resection in 10 (45%) and lobectomy in 12 (55%) patients). 14 (64%) patients had risk factors for recurrence, including surgical margins ≤ 2 cm, angiolymphatic and visceral pleural invasion.Salvage RTAfter a median 26 months (9–67), all 22 patients developed SL recurrence which was metabolically active on PET in all and biopsy-confirmed in 18/22 (82%) patients. All patients underwent RT targeting the location of the SL recurrence only. 13/22 (59%) patients had additional PE T-negative nodular or linear SL changes that were not included in the irradiated volume.Recurrence after RTAfter a median 17 months (9–34) 10/22 (45%) patients recurred either regionally 6/10 (60%), in the lungs 4/10 (40%) or distally 3/10 (30%). No patient recurred at the SL. Two-year overall and disease-free survival rates after RT were 71% and 65%, respectively.ConclusionRT to SL recurrences alone results in excellent local control. Additional treatment to reduce regional and distant recurrences should be considered.  相似文献   

17.
    
Purpose: Stereotactic body radiation therapy allows for a precise dose delivery. Organ motion bears the risk of undetected high dose healthy tissue exposure. An organ very susceptible to high dose is the oesophagus. Its low contrast on CT and the oblong shape render motion estimation difficult. We tackle this issue by modern algorithms to measure oesophageal motion voxel-wise and estimate motion related dosimetric impacts.Methods: Oesophageal motion was measured using deformable image registration and 4DCT of 11 internal and 5 public datasets. Current clinical practice of contouring the organ on 3DCT was compared to timely resolved 4DCT contours. Dosimetric impacts of the motion were estimated by analysing the trajectory of each voxel in the 4D dose distribution. Finally an organ motion model for patient-wise comparisons was built.Results: Motion analysis showed mean absolute maximal motion amplitudes of 4.55 ± 1.81 mm left-right, 5.29 ± 2.67 mm anterior-posterior and 10.78 ± 5.30 mm superior-inferior. Motion between cohorts differed significantly. In around 50% of the cases the dosimetric passing criteria was violated. Contours created on 3DCT did not cover 14% of the organ for 50% of the respiratory cycle and were around 38% smaller than the union of all 4D contours. The motion model revealed that the maximal motion is not limited to the lower part of the organ. Our results showed motion amplitudes higher than most reported values in the literature and that motion is very heterogeneous across patients.Conclusions: Individual motion information should be considered in contouring and planning.  相似文献   

18.
Summary Two types of reactivities of thiophosphates have been demonstrated: one being nucleophilic displacement by the P-S moiety of nucleoside phosphorothioates and the other, phosphorylation via P-S cleavage as the driving force. We have designed a system where both displacement on carbon and P-S cleavage are possible. Adenosine derivatives have been synthesized with 5-deoxy-5-chloro and 5-O-tosyl substitutions as leaving groups utilizing the 3-O-phosphorothioate as the biphilic center. The main products of cyclization were 5-O-tosyl and 5-chloroadenosine 2:3-cyclic phosphate. Formation of 3:5-S-phosphorothioate was slow even using an excellent leaving group. This is possibly due to hydrogen bonding between the 2-OH and the neighboring P-O. KOH hydrolysis of the cyclic phosphorothioate yielded 2(3) phosphorothioates in a 1:1 ratio. The 2 and 3 isomers were separated and used to study the relative rates of cyclization. The cyclization via P-S cleavage of 2(3)-O-phosphorothioates showed that the 2 isomer was more reactive. This is the first report of superior reactivity of the 3-OH of a ribonucleoside.  相似文献   

19.
    
Purpose/objectiveStereotactic ablative body radiotherapy (SABR) in multi-centre trials requires rigorous quality assurance to ensure safe and consistent treatment for all trial participants. We report results of vertebral SABR dosimetry credentialing for the ALTG/TROG NIVORAD trial.Material/methodsCentres with a previous SABR site visit performed axial film measurement of the benchmarking vertebral plan in a local phantom and submitted radiochromic film images for analysis. Remaining centres had on-site review of SABR processes and axial film measurement of the vertebral benchmarking plan. Films were analysed for dosimetric and positional accuracy: gamma analysis (>90% passing 2%/2mm/10% threshold) and ≤ 1 mm positional accuracy at target-cord interface was required.Results19 centres were credentialed; 11 had on-site measurement. Delivery devices included linear accelerator, TomoTherapy and CyberKnife systems. Five centres did not achieve 90% gamma passing rate. Of these, three were out of tolerance (OOT) in low (<5Gy) dose regions and > 80% passing rate and deemed acceptable. Two were OOT over the full dose range: one elected not to remeasure; the other also had positional discrepancy greater than 1 mm and repeat measurement with a new plan was in tolerance. The original OOT was attributed to inappropriate MLC constraints. All centres delivered planned target-cord dose gradient within 1 mm.ConclusionCredentialing measurements for vertebral SABR in a multi-centre trial showed although the majority of centres delivered accurate vertebral SABR, there is high value in independent audit measurements. One centre with inappropriate MLC settings was detected, which may have resulted in delivery of clinically unacceptable vertebral SABR plans.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号