首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 33 毫秒
1.
A rugged, sensitive and efficient liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of firocoxib in urine from 5 to 3000 ng/mL and in plasma from 1 to 3000 ng/mL. The method requires 200 microL of either plasma or urine and includes sample preparation in 96-well solid phase extraction (SPE) plates using a BIOMEK 2000 Laboratory Automated Workstation. Chromatographic separation of firocoxib from matrix interferences was achieved using isocratic reversed phase chromatography on a PHENOMENEX LUNA Phenyl-Hexyl column. The mobile phase was 45% acetonitrile and 55% of a 2 mM ammonium formate buffer. The method was accurate (88-107%) and precise (CV<12.2%) within and between sets. Extraction efficiencies (recovery)>93% were achieved and ionization efficiencies (due to matrix effects) were >72%. Extensive stability and ruggedness testing was also performed; therefore, the method can be used for pharmacokinetic studies as well as drug monitoring and screening. The data presented here is the first LC-MS/MS method for the quantitation of firocoxib in plasma (LLOQ of 1 ng/mL), a 25-fold improvement in sensitivity over the HPLC-UV method and the first quantitative method for firocoxib in urine (LLOQ of 5 ng/mL). Additionally the sample preparation process has been automated to improve efficiency.  相似文献   

2.
As a part of the project for screening unequivocal biomarkers after sulfur mustard exposure, a quantitative method for the determination of β-lyase metabolites 1,1'-sulfonylbis-[2-(methylsulfinyl)ethane] (SBMSE) and 1-methylsulfinyl-2-[2-(methylthio)ethylsulfonyl]ethane (MSMTESE) was validated. Full validation was conducted according to the FDA guidelines for method validation using pooled human urine as a sample matrix. The metabolites were extracted from urine with an optimized sample preparation procedure using ENV+ solid phase extraction cartridge with reduced volume of sample and solvents. Metabolites were detected by improved and faster liquid chromatography-heated electrospray ionization-tandem mass spectrometry (LC-HESI-MS/MS) method with two transitions of each chemical using non-buffered eluents, post-column splitter and higher flow-rate. These provided over five times faster analysis than previously published method providing 4.5 min/sample cycle time, to achieve up to 200 samples per day (24 h). Quantification was performed using deuterium labelled internal standard of SBMSE. The method was linear over the concentration range of 5-200 ng/ml (average correlation coefficients were R(2)=0.997 and R(2)=0.989) for both β-lyase metabolites, SBMSE and MSMTESE, respectively. The average retention times for SBMSE and MSMTESE were 1.96±0.01 min and 3.24±0.03 min (n=54). Calculated limits of detection were 4 ng/ml for both SBMSE and MSMTESE, respectively. Lower limits of quantification were 10 ng/ml and 11 ng/ml for SBMSE and MSMTESE, respectively. This validated method was successfully used in the First Confidence Building Exercise on Biomedical Samples Analysis organized by the Organisation for the Prohibition of Chemical Weapons (OPCW). Identification criteria for analysing unequivocal biomarkers of sulfur mustard with LC-MS/MS after alleged use is discussed and proposed based on the validation and exercise results.  相似文献   

3.
The collection of oral fluid for drug testing is easy and non-invasive. This study developed a drug testing method using ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) in selected-reaction monitoring (SRM) mode. We tested the method on the analysis of four opiates and their metabolites, five amphetamines, flunitrazepam and its two metabolites, and cocaine and its four metabolites in oral fluid. 100-μL samples of oral fluid were diluted with twice the amount of water then spiked with isotope-labeled internal standards. After the samples had undergone high-speed centrifugation for 20 min, we analyzed the supernatant. The recovery of the sample preparation ranged from 81 to 108%. We compared the performance of electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). The ion suppression of most analytes on ESI (28-78%) was lower than that of APCI and APPI. A post-column flow split (5:1) did not reduce the matrix effect on ESI. Direct APPI performed better than dopant-assisted APPI using toluene. ESI, APCI and APPI limits of quantitation mostly ranged from 0.11 to 1.9 ng/mL, 0.02 to 2.2 ng/mL and 0.02 to 2.1 ng/mL, respectively, but were much higher on amphetamine and ecgonine methyl ester (about 2.7-4.7 ng/mL, 8.7-14 ng/mL, and 10-19 ng/mL, respectively). Most of the bias percentages (accuracy) and relative standard deviations (precision) on spiked samples were below 15%. This method greatly simplifies the process of sample preparation and shortens the chromatographic time to only 7.5 min per run and is able to detect analytes at sub-ppb levels.  相似文献   

4.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

5.
The elastin degradation products, desmosine (DES) and isodesmosine (IDES) are highly stable, cross-linking amino-acids that are unique to mature elastin. The excretion of DES/IDES in urine, in the free form and with associated peptide fragments, provides an indicator of lung damage in chronic obstructive pulmonary disease (COPD). A quantitative ion mobility-mass spectrometry (IM-MS) method has been developed for the analysis of free DES/IDES in urine with deuterated IDES as an internal standard. Resolution of DES/IDES isomers was achieved in less than five minutes using ultra performance liquid chromatography (UPLC) combined with ion pairing. The optimized UPLC-IM-MS method provided a linear dynamic range of 10-300 ng/mL and a limit of quantitation of 0.028 ng/mL for IDES and 0.03 ng/mL for DES (0.55 ng and 0.61 ng on column respectively). The method reproducibility (%RSD) was <4% for DES and IDES. The UPLC-IM-MS method was applied to the analysis of urine samples obtained from healthy volunteers and COPD patients. The DES/IDES concentrations in healthy and COPD urine showed an increase in DES (79%) and IDES (74%) in the COPD samples, relative to healthy controls. The incorporation of an IM separation prior to m/z measurement by MS was shown to reduce non-target ion responses from the bio-fluid matrix.  相似文献   

6.
A method for measurement of an important biological marker, 1,1'-sulfonylbis[2-(methylthio)ethane] (SBMTE) of sulfur mustard agent HD [bis-(2-chloroethyl)sulfide] in human urine, to quantify HD exposure, is presented. It employs TiCl3 reduction of beta-lyase metabolites to SBMTE, and automated solid-phase extraction sample preparation, followed by isotope dilution liquid chromatography-positive ion-electrospray ionization-tandem mass spectrometry with 7.5 min/sample cycle time, to achieve SBMTE quantitation of up to 200 samples/24h a day. Percent relative standard deviations over the calibration range varied from 12.0% at 0.1 ng/mL to 0.9% at 100 ng/mL, and the limit of detection from a 0.5 mL sample was below the lowest level calibration standard of 0.1 ng/mL.  相似文献   

7.
Ginsenoside Re (G-Re) improved the memory function of experimental animals in a preclinical study. Several types of saponins including G-Rg1, G-Rg2, G-F1, G-Rh1, and protopanaxatriol (PPT) may be the metabolites of G-Re according to reports from preclinical trials. In order to support a study of the pharmacokinetics of G-Re, an analytical method for G-Re and the co-detection of its probable metabolites using liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed and validated. Solid phase extraction was utilized in the sample preparation. Separation of the analytes was achieved using a gradient elution (0.05% formic acid-methanol-acetonitrile, each organic phase containing 0.05% formic acid) at a flow rate of 0.3 mL/min with a retention time of approximately 2.88 min for G-Re. Data were acquired in the multiple reaction mode (MRM) and the linear range of the standard curve of plasma and urine samples for G-Re was 0.05-20 ng/mL with r(2)≥0.99. In the analysis of probable metabolites, G-Re, G-Rg1, G-F1, G-Rh1 and PPT were all detected in samples; however, G-Rg2 was not detected.  相似文献   

8.
Phytoestrogens (isoflavones and lignans) are of increasing interest due to their potential to prevent certain types of complex diseases. However, epidemiological evidence is needed on the levels of phytoestrogens and their metabolites in foods and biological fluids in relation to risk of these diseases. We report an assay for phytoestrogens which is sensitive, accurate, and uses low volumes of sample. Suitable for epidemiological studies, the assay consists of a simple sample preparation procedure and has been developed for the analysis of five isoflavones (daidzein, O-desmethylangolensin, equol, genistein, and glycitein) and two lignans (enterodiol and enterolactone), which requires only 200 microl of urine and utilizes one solid-phase extraction stage for sample preparation prior to derivatization for GC/MS analysis. Limits of detection were in the region 1.2 ng/ml (enterodiol) to 5.3ng/ml (enterolactone) and the method performed well in the UK Government's Food Standards Agency-sponsored quality assurance scheme for phytoestrogens. For the first time, average levels of all the above phytoestrogens were measured in samples of urine collected from a free living population sample of women. Results show a large range in both the amount and the type of phytoestrogens excreted.  相似文献   

9.
A quantitative method using liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for the simultaneous determination of 23 endogenous steroids in primate urine. The introduced method includes estrone, pregnandiol, cortisol, testosterone and several human urinary glucocorticoid and androgen metabolites. As the method is intended for the analysis of steroid hormones in behavioral studies on wild-living primates, it was adapted for a sample volume of 200microL urine. The sample preparation consisted of an enzymatic hydrolysis of steroid glucuronides using beta-glucuronidase from E. coli followed by a solvolytic cleavage of steroid sulfates employing sulfuric acid/ethyl acetate. The extraction of steroids from urine was optimized with respect to pH during extraction, type of ether and the amount of enzyme necessary for complete hydrolysis of glucuronides. The recovery of steroids spiked into urine before hydrolysis was 58.9-103.7% with an intra-day precision of 2.7-14.3% and an inter-day precision of 2.9-14.8%. Detection limits ranged from 0.1-0.5ng/mL. The reproducibility of the whole sample preparation process was also demonstrated for unspiked urine (CV 1.2-16.5%). The proportion of steroid hormone excreted as sulfate was determined for 21 steroids in chimpanzee urine. The solvolysis proved to be essential for all investigated steroids except for pregnandiol, tetrahydrocortisol and tetrahydrocortisone, which were found to be less then 10% in the solvolysis fraction.  相似文献   

10.
An automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for quantitative determination of donepezil in human plasma. 150 MicroL of plasma samples were placed in 2.2 mL 96-deepwell plates and both donepezil and loratadine (IS) were extracted from human plasma by liquid-liquid extraction (LLE), using hexane as the organic solvent. Robotic liquid handling workstations were employed for all liquid transfer and solution preparation steps and resulted in a short sample preparation time. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of reconstitution solution. The method developed, includes a sample analysis performed by reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The chromatographic run time was set for 2.0 min with a flow rate of 0.7 mL/min in a C18 analytical column. The method was significantly sensitive, specific, accurate and precise for the determination of donepezil in human plasma and had the shortest run time. The curve was proven to be linear for the concentration range of 0.1-100 ng/mL. After validation, the method was applied to the rapid and reliable quantitative determination of donepezil in a bioequivalence study after per os administration of a 5mg donepezil tablet.  相似文献   

11.
Roscovitine, a purine analogue that selectively inhibits cyclin-dependent kinases, has been considered as a potential anti-tumor drug. The determination of roscovitine in plasma and urine was performed using microextraction in packed syringe as on-line sample preparation method with liquid chromatography and tandem mass spectrometry. The sampling sorbent utilized was polystyrene polymer. 2H3-lidocaine was used as internal standard. The limit of detection for roscovitine was as low as 0.5 ng/mL and the lower limit of quantification was 1.0 ng/mL. The accuracy and precision values of quality control samples were between +/-15% and < or =11%, respectively. The calibration curve was obtained within the concentration range 0.5-2000 ng/mL in both plasma and urine. The regression correlation coefficients for plasma and urine samples were > or =0.999 for all runs. The present method is miniaturized and fully automated and can be used for pharmacokinetic and pharmacodynamic studies.  相似文献   

12.
A highly sensitive and quantitative LC/MS/MS assay for the determination of tilmicosin in serum has been developed and validated. For sample preparation, 0.2 mL of canine serum was extracted with 3 mL of methyl tert-butyl ether. The organic layer was transferred to a new vessel and dried under nitrogen. The sample was then reconstituted for analysis by high performance liquid chromatography-tandem mass spectrometry. A Phenomenex Luna C8(2) analytical column was used for the chromatographic separation. The eluent was subsequently introduced to the mass spectrometer by electrospray ionization. A single range was validated for 50-5000 ng/mL for support of toxicokinetic studies. The inter-day relative error (inaccuracy) for the LLOQ samples ranged from -5.5% to 0.3%. The inter-day relative standard deviations (imprecision) at the respective LLOQ levels were < or =10.1%.  相似文献   

13.
A simple, rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and fully validated for the quantitative determination of seven amphetamines and metabolites in urine. The method was validated for selectivity, linearity, LOQ, LOD, imprecision, bias, analyte and processed sample stability, matrix effect, recovery, carryover and dilution integrity. A classic liquid–liquid extraction with ethyl acetate was used as sample preparation procedure. The compounds were separated on an Acquity UPLC HSS C18 column in 6.8 min. The linear dynamic range was established from 25 to 500 ng/mL. The limit of quantification was fixed to the lowest calibrator level and the limit of detection ranged from 0.125 to 2.5 ng/mL. The method presented an excellent intra- and inter-assay imprecision and bias (<10.7%) at each measured concentration of two external quality controls (QC) and three “in house” QC. No matrix effects were observed and good recoveries (>70%) were obtained for all the compounds. No carryover was observed after the analysis of high concentrated samples (8000 ng/mL). The method was subsequently applied to authentic samples.  相似文献   

14.
The investigation of 3,4-methylenedioxymethamphetamine (MDMA; ecstasy) abuse requires very robust methods with high sensitivity and wide linearity ranges for the quantification of this drug of abuse and its main metabolites in body fluids. An optimized gas chromatography–ion trap mass spectrometry (GC–IT/MS) methodology with electron impact ionization addressing these issues is presented. The sample preparation involves an enzymatic hydrolysis of urine and plasma for conjugate cleavage, a SPE extraction, and a derivatization process. The method was fully validated in rat plasma and urine. Linearity for a wide concentration range was achieved for MDMA, and the metabolites 3,4-methylenedioxyamphetamine (MDA), 4-hydroxy-3-methoxyamphetamine (HMA) and 4-hydroxy-3-methoxymethamphetamine (HMMA). Limits of quantification were 2 ng/mL in plasma and 3.5 ng/mL in urine using a Selected Ion Monitoring detection mode. Selectivity, accuracy, precision, and recovery met the required criteria for the method validation. This GC–IT/MS method provides high sensitivity and adequate performance characteristics for the simultaneous quantification of MDMA, MDA, HMA and HMMA in the studied matrices.  相似文献   

15.
We improved our previous analytical method to measure phthalate metabolites in urine as biomarkers for phthalate exposure by automating the solid-phase extraction (SPE) procedure and expanding the analytical capability to quantify four additional metabolites: phthalic acid, mono-3-carboxypropyl phthalate, mono-isobutyl phthalate (miBP), and monomethyl isophthalate. The method, which involves automated SPE followed by isotope dilution-high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS), allows for the quantitative measurement of 15 phthalate metabolites in urine with detection limits in the low ng/ml range. SPE automation allowed for the unattended sequential extraction of up to 100 samples at a time, and resulted in an increased sample throughput, lower solvent use, and better reproducibility than the manual SPE. Furthermore, the modified method permitted for the first time, the separation and quantification of mono-n-butyl phthalate (mBP) and its structural isomer miBP. The method was validated on spiked pooled urine samples and on pooled urine samples from persons with no known exposure to phthalates.  相似文献   

16.
In this study, a method using liquid chromatography triple quadrupole mass spectrometry (LC/MS/MS) is described for the analysis of the plant growth regulator chlormequat (CCC) in human urine. Analysis was carried out using selected reaction monitoring (SRM) in the positive ion mode. [(2)H(4)] labeled CCC as internal standard (IS) was used for quantification of CCC. The limit of detection (LOD) was determined to 0.1 ng/mL. The method was linear in the range 0.3-800 ng/mL urine and had a within-run precision of 4-9%. The between-run precision was determined at urine levels of 7.0 and 31 ng/mL and found to be 5 and 6% respectively. The reproducibility was 3-6%. To validate CCC as a biomarker of exposure, the method was applied in a human experimental oral exposure to CCC. Two healthy volunteers received 25 μg/kg b.w. CCC in a single oral dose followed by urine sampling for 46 h post-exposure. The CCC was estimated to follow a first order kinetic and a two compartment model with an elimination half-life of 2-3h and 10-14 h respectively. One hundred 24h urine samples were collected from non-occupationally exposed individuals in the general population in southern Sweden. All samples had detectable levels above the LOD 0.1 ng/mL urine. The median levels were 4 ng/mL of CCC in unadjusted urine. The levels found in the population samples are several magnitudes lower than those found in the experimental exposure, which corresponds to an oral exposure of 50% of the ADI for CCC.  相似文献   

17.
Neonicotinoid pesticides have been widely applied for the production of fruits and vegetables, and occasionally detected in conventionally grown produce. Thus oral exposure to neonicotinoid pesticides may exist in the general population; however, neonicotinoid metabolites in human body fluids have not been investigated comprehensively. The purpose of this study is the qualitative profiling and quantitative analysis of neonicotinoid metabolites in the human spot urine by liquid chromatography coupled with mass spectrometry (LC/MS). Human urine samples were collected from three patients suspected of subacute exposure to neonicotinoid pesticides. A qualitative profiling of urinary metabolites was performed using liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) with a database of nominal molecular weights of 57 known metabolites of three neonicotinoid pesticides (acetamiprid, Imidacloprid, and clothianidin), as well as the parent compounds. Then a quantitative analysis of selected urinary metabolites was performed using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with a standard pesticide and metabolite, which were detected by the qualitative profiling. The result of qualitative profiling showed that seven metabolites, i.e. an acetamiprid metabolite, N-desmethyl-acetamiprid; three Imidacloprid metabolites, 5-hydroxy-Imidacloprid, 4,5-dihydroxy-imidacloprid, 4,5-dehydro-Imidacloprid; a common metabolite of acetamiprid and Imidacloprid, N-(6-chloronicotinoyl)-glycine; and two clothianidin metabolites, N-desmethyl-clothianidin, N-(2-(methylsulfanyl)thiazole-5-carboxyl)-glycine, as well as acetamiprid, were detected in the urine of three cases. The result of the quantitative analysis showed N-desmethyl-acetamiprid was determined in the urine of one case, which had been collected on the first visit, at a concentration of 3.2 ng/mL. This is the first report on the qualitative and quantitative detection of N-desmethyl-acetamiprid in the human urine. The results suggest that the one case with detection of N-desmethyl-acetamiprid was exposed to acetamiprid through the consumption of contaminated foods. Urinary N-desmethyl-acetamiprid, as well as 5-hydroxy-Imidacloprid and N-desmethyl-clothianidin, may be a good biomarker for neonicotinoid exposure in humans and warrants further investigation.  相似文献   

18.
We developed a LC-MS/MS method for the quantitative determination of the mercapturic acid (MA) metabolites of acrylamide (AA) AAMA and of its oxidative metabolite glycidamide (GA) GAMA in urine samples from the general population. The method requires 4 mL of urine which is solid phase extracted prior to LC-MS/MS analysis. The metabolites are detected by ESI-tandem mass spectrometry in negative ionisation mode and quantified by isotope dilution. Detection limits ranged down to 1.5 microg/L urine for both AAMA and GAMA. The imprecision expressed as R.S.D. lay between 2% and 6% for both analytes (intra- and inter-assay). First results on a small group of 29 persons out of the general population ranged from 5 to 338 microg/L AAMA and 相似文献   

19.
High throughput LC-MS/MS assays to quantitate a new alpha(nu)beta(3) bone integrin antagonist (I) in human plasma and urine have been developed using instruments programmed to automate sample preparation procedures. Packard liquid handling system-MultiPROBE II EX was programmed for preparing calibration standards in control plasma and urine, acidifying all standards, quality control (QC), and clinical samples with necessary dilutions, and adding the internal standard to the acidified samples. TOMTEC Quadra 96 was programmed to perform the solid phase extraction (SPE) process on a 3M 96-well mixed phase cation standard density (MPC-SD) plate to isolate the analytes from the sample matrix. The extract collected from both types of matrices was directly injected into reversed-phase LC-MS/MS system with a Turbo Ion Spray (TIS) interface in the positive ionization mode. The plasma and urine assays have the calibration range of 0.5-1500 and 2-6000 ng/mL, respectively. Validation of the automated and the manual plasma assays showed that application of MultiPROBE II to sample preparation gave comparable accuracy and precision. Overall, the automated approaches with minimum manual intervention enhanced the throughput of sample preparation.  相似文献   

20.
The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC–MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC–MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s).  相似文献   