首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Biocatalytic polytransesterification at high concentrations of monomers proceeds rapidly and is accompanied by an increase in the temperature of the reaction mixture due to liberation of heat of reaction during the initial phase. We have used principles of reaction calorimetry to monitor the kinetics of polymerization during this initial phase, thus relating the temperature to the extent of polymerization. Rate of polymerization increases with the concentration of monomers. This is also reflected by the increase in the temperature of the reaction mixture. Using time-temperature-conversion contours, a differential method of kinetic analysis was used to calculate the energy of activation ( approximately 15.1 Kcal/mol). Copyright 1998 John Wiley & Sons, Inc.  相似文献   

2.
An analysis of sigmoid-shaped progress curves in the reaction between Electric Eel acetylcholinesterase (acetylcholine acetylhydrolase, EC 3.1.1.7, AChE) and its substrate acetylthiocholine in low concentrations at pH 7 is presented. In order to be able to explain an initial apparent inhibition of the enzyme-substrate reaction, the rate of detection reaction had to be taken into account. The theoretical curves obtained by the fitting of differential equations for the reaction mechanism to the data of six progress curves simultaneously, exactly reproduce the course of the experimental curves. The measurements performed with various concentrations of detection reagent confirm the proposed cause of sigmoidity.  相似文献   

3.
We present a simple yet efficient technique to monitor the dynamics of DNA-based reaction circuits. This technique relies on the labeling of DNA oligonucleotides with a single fluorescent modification. In this quencher-free setup, the signal is modulated by the interaction of the 3'-terminus fluorophore with the nucleobases themselves. Depending on the nature of the fluorophore's nearest base pair, fluorescence intensity is decreased or increased upon hybridization. By tuning the 3'-terminal nucleotides, it is possible to obtain opposite changes in fluorescence intensity for oligonucleotides whose hybridization site is shifted by a single base. Quenching by nucleobases provides a highly sequence-specific monitoring technique, which presents a high sensitivity even for small oligonucleotides. Compared with other sequence-specific detection methods, it is relatively non-invasive and compatible with the complex dynamics of DNA reaction circuits. As an application, we show the implementation of nucleobase quenching to monitor a DNA-based chemical oscillator, allowing us to follow in real time and quantitatively the dephased oscillations of the components of the network. This cost-effective monitoring technique should be widely implementable to other DNA-based reaction systems.  相似文献   

4.
A kinetic study was performed of a model for an autocatalytic zymogen activation process involving both intra- and intermolecular routes, to which a chromogenic reaction in which the active enzyme acts upon one of its substrates was coupled to continuously monitor the reaction. Kinetic equations describing the evolution of species involved in the system with time were obtained. These equations are valid for any zymogen autocatalytic activation process under the same initial conditions. Experimental design and kinetic data analysis procedures to evaluate the kinetic parameters, based on the derived kinetic equations, are suggested. In addition, a dimensionless distribution coefficient was defined, which shows mathematically whether the intra- or the intermolecular route prevails once the kinetic parameters involved in the system are known. The validity of the results obtained was checked using simulated curves for the species involved. As an example of application of the method, the system is experimentally illustrated by the continuous monitoring of pepsinogen transformation to pepsin.  相似文献   

5.
The evolutionary origin of photosynthetic reaction centers has long remained elusive. Here, we use sequence and structural analysis to demonstrate an evolutionary link between the cytochrome b subunit of the cytochrome bc(1) complex and the core polypeptides of the photosynthetic bacterial reaction center. In particular, we have identified an area of significant sequence similarity between a three contiguous membrane-spanning domain of cytochrome b, which contains binding sites for two hemes, and a three contiguous membrane-spanning domain in the photosynthetic reaction center core subunits, which contains binding sites for cofactors such as (bacterio)chlorophylls, (bacterio)pheophytin and a non-heme iron. Three of the four heme ligands in cytochrome b are found to be conserved with the cofactor ligands in the reaction center polypeptides. Since cytochrome b and reaction center polypeptides both bind tetrapyrroles and quinones for electron transfer, the observed sequence, functional and structural similarities can best be explained with the assumption of a common evolutionary origin. Statistical analysis further supports a distant but significant homologous relationship. On the basis of previous evolutionary analyses that established a scenario that respiration evolved prior to photosynthesis, we consider it likely that cytochrome b is the evolutionary precursor for type II reaction center apoproteins. With a structural analysis confirming a common evolutionary origin of both type I and type II reaction centers, we further propose a novel "reaction center apoprotein early" hypothesis to account for the development of photosynthetic reaction center holoproteins.  相似文献   

6.
Selected or multiple reaction monitoring is a targeted mass spectrometry method (S/MRM-MS), in which many peptides are simultaneously and consistently analyzed during a single liquid chromatography-mass spectrometry (LC-S/MRM-MS) measurement. These capabilities make S/MRM-MS an attractive method to monitor a consistent set of proteins over various experimental conditions. To increase throughput for S/MRM-MS it is advantageous to use scheduled methods and unfractionated protein extracts. Here, we established the practically measurable dynamic range of proteins reliably detectable and quantifiable in an unfractionated protein extract from a human cell line using LC-S/MRM-MS. Initially, we analyzed S/MRM transition peak groups in terms of interfering signals and compared S/MRM transition peak groups to MS1-triggered MS2 spectra using dot-product analysis. Finally, using unfractionated protein extract from human cell lysate, we quantified the upper boundary of copies per cell to be 35 million copies per cell, while 7500 copies per cell represents a lower boundary using a single 35 min linear gradient LC-S/MRM-MS measurement on a current, standard commercial instrument.  相似文献   

7.
In the production of antibody-drug conjugates (ADCs), the conjugation reaction is a central step defining the final product composition and, hence, directly affecting product safety and efficacy. To enable real-time monitoring, spectroscopic sensors in combination with multivariate regression models have gained popularity in recent years. The extended Kalman filter (EKF) can be used as so-called soft-sensor to fuse sensor predictions with long-horizon forecasts by process models. This enables the dynamic update of the current state and provides increased robustness against experimental noise or model errors. Due to the uncertainty associated with sensor and process models in biopharmaceutical applications, the deployment of such soft-sensors is challenging. In this study, we demonstrate the combination of an uncertainty-aware sensor model with a kinetic reaction model using an EKF to monitor a site-directed ADC conjugation reaction. As the sensor model, a Gaussian process regression model is presented to realize a time-variant determination of the sensor uncertainty. The EKF fuses the time-discrete predictions of the amount of conjugated drug from the sensor model with the time-continuous predictions from the kinetic model. While the ADC species are not distinguishable by on-line recorded UV/Vis spectra, the developed soft-sensor is able to dynamically update all relevant reaction species. It could be shown that the use of time-variant process and sensor noise computation approaches improved the performance of the EKF and achieved a reduction of the prediction error of up to 23% compared with the kinetic model. The developed framework proved to enhance robustness against noisy sensor measurements or wrong model initialization and was successfully transferred from batch to fed-batch mode. In future, this framework could be implemented for model-based process control and be adopted for other ADC conjugation reaction types.  相似文献   

8.
Described herein is the synthesis of a hapten of biocyclo[2,2,2]octene 5 designed to mimic the exo transition-state of an aza Diels-Alder reaction. Immunization of rabbits with this hapten provided polyclonal antibodies, Aza-BSA-3, which were used to synthesize adduct 4b in the first reported antibody-catalyzed exo Diels-Alder reaction.  相似文献   

9.
10.
New mass spectrometry (MS) methods, collectively known as data independent analysis and hyper reaction monitoring, have recently emerged. These methods hold promises to address the shortcomings of data-dependent analysis and selected reaction monitoring (SRM) employed in shotgun and targeted proteomics, respectively. They allow MS analyses of all species in a complex sample indiscriminately, or permit SRM-like experiments conducted with full high-resolution product ion spectra, potentially leading to higher sequence coverage or analytical selectivity. These methods include MSE, all-ion fragmentation, Fourier transform-all reaction monitoring, SWATH Acquisition, multiplexed MS/MS, pseudo-SRM (pSRM) and parallel reaction monitoring (PRM). In this review, the strengths and pitfalls of these methods are discussed and illustrated with examples. In essence, the suitability of the use of each method is contingent on the biological questions posed. Although these methods do not fundamentally change the shape of proteomics, they are useful additional tools that should expedite biological discoveries.  相似文献   

11.
An accurate, rapid, and versatile method for the analysis of enzyme kinetics using electrospray ionization mass spectrometry (ESI-MS) has been developed and demonstrated using fucosyltransferase V. Reactions performed in primary or secondary amine-containing buffers were diluted in an ESI solvent and directly analyzed without purification of the reaction products. Decreased mass resolution was used to maximize instrument sensitivity, and multiple reaction monitoring (MRM), in the tandem mass spectrometric mode, was used to enhance selectivity of detection. The approach allowed simultaneous monitoring of multiple processes, including substrate consumption, product formation, and the intensity of an internal standard. MRM gave an apparent K(m) for GDP-L-fucose (GDP-Fuc) of 50.4 +/- 5.5 microM and a k(cat) of 1.46 +/- 0.044 s(-1). Under the same conditions, the conventional radioactivity-based assay using GDP-[U-(14)C]Fuc as substrate gave virtually identical results: K(m) = 54.3 +/- 4.6 microM and k(cat) = 1.49 +/- 0.039 s(-1). The close correlation of the data showed that ESI-MS coupled to MRM is a valid approach for the analysis of enzyme kinetics. Consequently, this method represents a valuable alternative to existing analytic methods because of the option of simultaneously monitoring multiple species, the high degree of specificity, and rapid analysis times and because it does not rely on the availability of radioactive or chromogenic substrates.  相似文献   

12.
Selected reaction monitoring, also known as multiple reaction monitoring, is a powerful targeted mass spectrometry approach for a confident quantitation of proteins/peptides in complex biological samples. In recent years, its optimization and application have become pivotal and of great interest in clinical research to derive useful outcomes for patient care. Thus, selected reaction monitoring/multiple reaction monitoring is now used as a highly sensitive and selective method for the evaluation of protein abundances and biomarker verification with potential applications in medical screening. This review describes technical aspects for the development of a robust multiplex assay and discussing its recent applications in cardiovascular proteomics: verification of promising disease candidates to select only the highest quality peptides/proteins for a preclinical validation, as well as quantitation of protein isoforms and post-translational modifications.  相似文献   

13.
Serine acetyltransferase is a member of the left-handed parallel beta-helix family of enzymes that catalyzes the committed step in the de novo synthesis of l-cysteine in bacteria and plants. The enzyme has an ordered kinetic mechanism with acetyl CoA bound prior to l-serine and O-acetyl-l-serine released prior to CoA. The rate-limiting step along the reaction pathway is the nucleophilic attack of the serine hydroxyl on the thioester of acetyl CoA. Product release contributes to rate-limitation at saturating concentrations of reactants. The reaction is catalyzed by an active site general base with a pK of 7, which accepts a proton from the serine hydroxyl as a tetrahedral intermediate is formed between the reactants, and donates it to the thiol of CoA as the intermediate collapses to give products. This mechanism is likely the same for all O-acyltransferases that catalyze their reaction by direct attack of the alcohol on the acyl donor, using an active-site histidine as the general base. Serine acetyltransferase is regulated by feedback inhibition by the end product l-cysteine, which acts by binding to the serine site in the active site and inducing a conformational change that prevents reactant binding. The enzyme also associates with O-acetylserine sulfhydrylase, the final enzyme in the biosynthetic pathway, which contributes to stabilizing the acetyltransferase.  相似文献   

14.
Quantification of protein and PTM abundance in biological samples is an important component of proteomic studies. Label-free methods for quantification using MS are attractive because they are simple to implement and applicable to any experimental system. We demonstrate that PTM stoichiometry can be accurately measured using label-free quantification and selected reaction monitoring. Use of selected reaction monitoring is advantageous with complex biological samples and we show this approach can be used to quantify multiple PTMs independently on a single peptide.  相似文献   

15.
Structures at steady states have been investigated for an enzyme reaction in a continuous stirred tank reactor that has a random bi-uni reaction mechanism, using the imperfect bifurcation theory via singularities. The analysis has shown that two types of singular points exist. One of these points has the two types of transition states characterized by the hysteresis and double-limit points. It is obtained when the derivative of the steady-state equation with respect to the bifurcation parameter does not vanish. When the derivative vanishes, the other type of singular point is obtained. This point has the two transition states of hysteresis and bifurcation points.  相似文献   

16.
A stochastic model is developed for an enzyme reaction in an open linear system. The proposed model assumes that the open system maintains the concentration of substrate and inhibitor at constant levels and that the product molecules are removed from the system by a first order reaction. Stochastic models for several enzyme reactions occurring in this open system are shown to correspond to special cases of theGI/M/∞ queue. Takács’ (1958) results for this queueing system are used to obtain the stochastic properties of the enzyme systems. A specific model we studied assumed completely competitive inhibition in an open system. The stationary distribution for the number of product molecules in the system is obtained. The enzyme reaction which incorporated the “intermediate chain hypothesis” can also be investigated by the queueing theory approach. It is shown that for this open system, if the model which incorporated the intermediate chain hypothesis has the same deterministic properties as the Michaelis-Menten model, then the latter has greater stochastic variation than the former. Research supported by the NIH Training Grant No. GM 1237-05 awarded to the Department of Statistics, The Johns Hopkins University. This paper in whole or in part may be reproduced for any purpose of the United States Government.  相似文献   

17.
Liquid chromatography-multiple reaction monitoring mass spectrometry of peptides using stable isotope dilution (SID) provides a powerful tool for targeted protein quantitation. However, the high cost of labeled peptide standards for SID poses an obstacle to multiple reaction monitoring studies. We compared SID to a labeled reference peptide (LRP) method, which uses a single labeled peptide as a reference standard for all measured peptides, and a label-free (LF) approach, in which quantitation is based on analysis of un-normalized peak areas for detected MRM transitions. We analyzed peptides from the Escherichia coli proteins alkaline phosphatase and β-galactosidase spiked into lysates from human colon adenocarcinoma RKO cells. We also analyzed liquid chromatography-multiple reaction monitoring mass spectrometry data from a recently published interlaboratory study by the National Cancer Institute Clinical Proteomic Technology Assessment for Cancer network (Addona et al. (2009) Nat. Biotechnol. 27: 633-641), in which unlabeled and isotopically labeled synthetic peptides or their corresponding proteins were spiked into human plasma. SID displayed the highest correlation coefficients and lowest coefficient of variation in regression analyses of both peptide and protein spike studies. In protein spike experiments, median coefficient of variation values were about 10% for SID and 20-30% for LRP and LF methods. Power calculations indicated that differences in measurement error between the methods have much less impact on measured protein expression differences than biological variation. All three methods detected significant (p < 0.05) differential expression of three endogenous proteins in a test set of 10 pairs of human lung tumor and control tissues. Further, the LRP and LF methods both detected significant differences (p < 0.05) in levels of seven biomarker candidates between tumors and controls in the same set of lung tissue samples. The data indicate that the LRP and LF methods provide cost-effective alternatives to SID for many quantitative liquid chromatography-multiple reaction monitoring mass spectrometry applications.  相似文献   

18.
The light absorption of ozone in an air stream allowed the monitoring of reactions of ozone with unsaturated fatty acids in solution. The kinetics for the reaction of ozone with linolenic acid was found to be of a pseudo-first-order after the first few minutes and did not vary with the concentration of ozone introduced into the solution. The reaction of ozone with linolenic acid in solution was found to be exceedingly rapid.When various combinations of polyunsaturated fatty acids were injected simultaneously, they reacted independently. The stoichiometry of ozone reacted to number of double bonds present in the fatty acid was one for mono- and diunsaturated; however, for triunsaturated fatty acid the stoichiometry was about 0.70.Malondialdehyde was produced upon the reaction of ozone with di- and triunsaturated fatty acids, as shown by both the thiobarbituric acid test and the characteristic UV absorption of malondialdehyde in solution. The true yield of malondialdehyde for the reaction of polyunsaturated fatty acids with ozone was found to be about 2%. In addition, other species, absorbing at 290–300 nm, were formed in solution during ozonolysis.  相似文献   

19.
The effects of arsenite on the reaction of reduced xanthine oxidase with oxygen are determined. The kinetics of the reaction monitoring the return of enzyme absorbance are investigated as are the kinetics and stoichiometries of peroxide and superoxide formation. Although some of the effects of arsenite are qualitatively consistent with expectations based on the known perturbation of the molybdenum midpoint potentials by arsenite, several results cannot be so easily explained. Specifically, arsenite introduces a very rapid phase (kobs = 110 s-1 at 125 microM oxygen) to the oxidative half-reaction which is not observed with the native enzyme. Arsenite also diminishes the amount of superoxide produced and eliminates one-electron reduced enzyme as a detectable kinetic intermediate in the reoxidation pathway. These differences appear to result from the ability of arsenite to greatly enhance the oxygen- and/or superoxide-reactivity of the reduced molybdenum center. This is reflected in the observation that reduced forms of arsenite-complexed xanthine oxidase lacking functional FAD (iodoacetamide-alkylated enzyme and deflavo enzyme) react relatively rapidly with oxygen whereas these reactions are quite slow in the absence of arsenite.  相似文献   

20.
Multiple reaction monitoring is a mass spectrometry technology used to selectively identify and quantify a known molecule in a complex mixture. The technology has gained favor in proteomic applications, especially for biomarker quantification in human samples. For this purpose, employment of internal standard consisting of isotopically (heavy) labeled proteins is currently considered the best way of normalizing sample preparation and correcting for different ionization efficiencies. However, synthesis of heavy-labeled proteins is considered laborious and expensive. The work outlined here presents an efficient strategy of utilizing isotope-labeled amino acids in cell culture to produce heavy-labeled proteins. These are then spiked into serum and serve as internal standards to relatively quantify a large number of target proteins. The method has been applied to quantify 72 proteins in the sera of pancreatic cancer patients with remarkable efficiency and accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号