1.
PurposeTo investigate the performances of two commercial treatment planning systems (TPS) for Volumetric Modulated Arc Therapy (VMAT) optimization regarding prostate cancer. The TPS were compared in terms of dose distributions, treatment delivery parameters and quality control results.Materials and methodsFor ten patients, two VMAT plans were generated: one with Monaco TPS (Elekta) and one with Pinnacle TPS (Philips Medical Systems). The total prescribed dose was 78 Gy delivered in one 360° arc with a Synergy® linear accelerator equipped with a MLCi2®.ResultsVMAT with Monaco provided better homogeneity and conformity indexes but lower mean dose to PTVs than Pinnacle. For the bladder wall (p = 0.019), the femoral heads (p = 0.017), and healthy tissues (p = 0.005), significantly lower mean doses were found using Monaco. For the rectal wall, VMAT with Pinnacle provided a significantly (p = 0.047) lower mean dose, and lower dose into 50% of the volume (p = 0.047) compared to Monaco. Despite a greater number of monitor units (factor 1.5) for Monaco TPS, the total treatment time was equivalent to that of Pinnacle. The treatment delivery parameter analysis showed larger mean MLC area for Pinnacle and lower mean dose rate compared to Monaco. The quality control results gave a high passing rate (>97.4%) for the gamma index for both TPS but Monaco provided slightly better results.ConclusionFor prostate cancer patients, VMAT treatment plans obtained with Monaco and Pinnacle offered clinically acceptable dose distributions. Further investigations are in progress to confirm the performances of the two TPS for irradiating more complex volumes.  相似文献   

2.

The hypofractionated radiotherapy modality was established to reduce treatment durations and enhance therapeutic efficiency, as compared to conventional fractionation treatment. However, this modality is challenging because of rigid dosimetric constraints. This study aimed to assess the impact of multi-leaf collimator (MLC) widths (10 mm and 5 mm) on plan quality during the treatment of prostate cancer. Additionally, this study aimed to investigate the impact of the MLC mode of energy on the Agility flattening filter (FF), MLC Agility-free flattening filter (FFF), and MLCi2 for patients receiving hypofractionated radiotherapy. Two radiotherapy techniques; Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Radiotherapy (VMAT), were used in this research. In the present study, computed tomography simulations of ten patients (six plans per patient) with localized prostate adenocarcinoma were analyzed. Various dosimetric parameters were assessed, including monitor units, treatment delivery times, conformity, and homogeneity indices. To evaluate the plan quality, dose-volume histograms (DVHs) were estimated for each technique. The results demonstrated that the determined dosimetric parameters of planning target volume (PTV)p (such as D mean, conformity, and homogeneity index) showed greater improvement with MLC Agility FF and MLC Agility FFF than with MLCi2. Additionally, the treatment delivery time was reduced in the MLC Agility FF (by 31%) and MLC Agility FFF (by 10.8%) groups compared to the MLCi2 group. It is concluded that for both the VMAT and IMRT techniques, the smaller width (5 mm) MLCs revealed better planning target volume coverage, improved the dosimetric parameters for PTV, reduced the treatment time, and met the constraints for OARs. It is therefore recommended to use 5 mm MLCs for hypofractionated prostate cancer treatment due to better target coverage and better protection of OARs.

  相似文献   

3.
PurposeTo quantify the impact of simulated errors for nasopharynx radiotherapy across multiple institutions and planning techniques (auto-plan generated Volumetric Modulated Arc Therapy (ap-VMAT), manually planned VMAT (mp-VMAT) and manually planned step and shoot Intensity Modulated Radiation Therapy (mp-ssIMRT)).MethodsTen patients were retrospectively planned with VMAT according to three institution’s protocols. Within one institution two further treatment plans were generated using differing treatment planning techniques. This resulted in mp-ssIMRT, mp-VMAT, and ap-VMAT plans. Introduced treatment errors included Multi Leaf Collimator (MLC) shifts, MLC field size (MLCfs), gantry and collimator errors. A change of more than 5% in most selected dose metrics was considered to have potential clinical impact. The original patient plan total Monitor Units (MUs) were correlated to the total number of dose metrics exceeded.ResultsThe impact of different errors was consistent, with ap-VMAT plans (two institutions) showing larger dose deviations than mp-VMAT created plans (one institution). Across all institutions’ VMAT plans the significant errors included; ±5° for the collimator angle, ±5 mm for the MLC shift and +1, ±2 and ±5 mm for the MLC field size. The total number of dose metrics exceeding tolerance was positively correlated to the VMAT total plan MUs (r = 0.51, p < 0.001), across all institutions and techniques.ConclusionsDifferences in VMAT robustness to simulated errors across institutions occurred due to planning method differences. Whilst ap-VMAT was most sensitive to MLC errors, it also produced the best quality treatment plans. Mp-ssIMRT was most robust to errors. Higher VMAT treatment plan complexity led to less robust plans.  相似文献   

4.
PurposeTo perform a detailed evaluation of dose calculation accuracy and clinical feasibility of Mobius3D. Of particular importance, multileaf collimator (MLC) modeling accuracy in the Mobius3D dose calculation algorithm was investigated.MethodsMobius3D was fully commissioned by following the vendor-suggested procedures, including dosimetric leaf gap (DLG) optimization. The DLG optimization determined an optimal DLG correction factor which minimized the average difference between calculated and measured doses for 13 patient volumetric-modulated arc therapy (VMAT) plans. Two sets of step-and-shoot plans were created to examine MLC and off-axis open fields modeling accuracy of the Mobius3D dose calculation algorithm: MLC test set and off-axis open field test set. The test plans were delivered to MapCHECK for the MLC tests and an ionization chamber for the off-axis open field test, and these measured doses were compared to Mobius3D-calculated doses.ResultsThe mean difference between the calculated and measured doses across the 13 VMAT plans was 0.6% with an optimal DLG correction factor of 1.0. The mean percentage of pixels passing gamma from a 3%/1 mm gamma analysis for the MLC test set was 43.5% across the MLC tests. For the off-axis open field tests, the Mobius3D-calculated dose for 1.5 cm square field was −4.6% lower than the chamber-measured dose.ConclusionsIt was demonstrated that Mobius3D has dose calculation uncertainties for small fields and MLC tongue-and-groove design is not adequately taken into consideration in Mobius3D. Careful consideration of DLG correction factor, which affects the resulting dose distributions, is required when commissioning Mobius3D for patient-specific QA.  相似文献   

5.
PurposeThe log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error.Methods and materialsModified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5 mm in opposite directions and systematic leaf shifts: ±1.0 mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.ResultsFor MLC leaves calibrated within ±0.5 mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32 ± 0.27% and 0.82 ± 0.17 Gy for PTV and spinal cord, respectively, and in prostate plans 1.22 ± 0.36%, 0.95 ± 0.14 Gy, and 0.45 ± 0.08 Gy for PTV, rectum, and bladder, respectively.ConclusionsIn this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.  相似文献   

6.
IntroductionPrevious literature has shown general trade-offs between plan complexity and resulting quality assurance (QA) outcomes. However, existing solutions for controlling this trade-off do not guarantee corresponding improvements in deliverability. Therefore, this work explored the feasibility of an optimization framework for directly maximizing predicted QA outcomes of plans without compromising the dosimetric quality of plans designed with an established knowledge-based planning (KBP) technique.Materials and MethodsA support vector machine (SVM) was developed – using a database of 500 previous VMAT plans – to predict gamma passing rates (GPRs; 3%/3mm percent dose-difference/distance-to-agreement with local normalization) based on selected complexity features. A heuristic, QA-based optimization (QAO) framework was devised by utilizing the SVM model to iteratively modify mechanical treatment features most commonly associated with suboptimal GPRs. Specifically, leaf gaps (LGs) <50 mm were widened by random amounts, which impacts all aperture-based complexity features. 13 prostate KBP-guided VMAT plans were optimized via QAO using user-specified maximum LG displacements before corresponding changes in predicted GPRs and dose were assessed.ResultsPredicted GPRs increased by an average of 1.14 ± 1.25% (p = 0.006) with QAO using a 3 mm maximum random LG displacement. There were small differences in dose, resulting in similarly small changes in tumor control probability (maximum increase = 0.05%) and normal tissue complication probabilities in the bladder, rectum, and femoral heads (maximum decrease = 0.2% in the rectum).ConclusionThis study explored the feasibility of QAO and warrants future investigations of further incorporating QA endpoints into plan optimization.  相似文献   

7.
AimThe aim is a dosimetric comparison of dynamic conformal arc integrated with the segment shape optimization and variable dose rate (DCA_SSO_VDR) versus VMAT for liver SBRT and interaction of various treatment plan quality indices with PTV and degree of modulation (DoM) for both techniques.BackgroundThe DCA is the state-of-the-art technique but overall inferior to VMAT, and the DCA_SSO_VDR technique was not studied for liver SBRT.Materials and methodsTwenty-five patients of liver SBRT treated using the VMAT technique were selected. DCA_SSO_VDR treatment plans were also generated for all patients in Monaco TPS using the same objective constraint template and treatment planning parameters as used for the VMAT technique. For comparison purpose, organs at risk (OARs) doses and treatment plans quality indices, such as maximum dose of PTV (Dmax%), mean dose of PTV (Dmean%), maximum dose at 2 cm in any direction from the PTV (D2cm%), total monitor units (MU’s), gradient index R50%, degree of modulation (DoM), conformity index (CI), homogeneity index (HI), and healthy tissue mean dose (HTMD) were compared.ResultsSignificant dosimetric differences were observed in several OARs doses and lowered in VMAT plans. The D2cm%, R50%, CI, HI and HTMD are dosimetrically inferior in DCA_SSO_VDR plans. The higher DoM results in poor dose gradient and better dose gradient for DCA_SSO_VDR and VMAT treatment plans, respectively.ConclusionsFor liver SBRT, DCA_SSO_VDR treatment plans are neither dosimetrically superior nor better alternative to the VMAT delivery technique. A reduction of 69.75% MU was observed in DCA_SSO_VDR treatment plans. For the large size of PTV and high DoM, DCA_SSO_VDR treatment plans result in poorer quality.  相似文献   

8.
PurposeThe aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT).MethodsTwenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose–volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences.ResultsConsiderable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = −0.712, −0.628 and −0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose–volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria.ConclusionLocal gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan.  相似文献   

9.
PurposeThe purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths.Methods and materialsOwing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD).ResultsThe contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP–VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP–VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP–VMAT either improved or maintained femoral heads compared to SE–VMAT. SAMP–VMAT reduced the nontarget tissue integral dose in all ten cases.ConclusionsA single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage.  相似文献   

10.
PurposeTo increase the superficial dose and reduce the brain dose for radiotherapy of scalp angiosarcoma, we propose a novel irradiation technique of tangential irradiation volumetric modulated arc therapy (TI-VMAT).MethodsTI-VMAT and the conventional VMAT treatment plans for thirteen scalp angiosarcoma patients were created with a prescribed dose of 70 Gy. Each treatment was normalized to cover 95% of the planning target volume (PTV) with its prescribed dose. To realize TI-VMAT, an avoidance structure (AS) function was applied. AS was defined as a contour subtracted PTV by a certain space from the brain contour. TI-VMAT treatment plans for six different spaces between PTV and AS were developed and compared with the conventional VMAT treatment plan with respect to the following dosimetric parameters: homogeneity index (HI) and conformity index (CI) of the PTV, mean brain dose, and brain volume irradiated with 20% (V20% [cc]), 40% (V40% [cc]), 60% (V60% [cc]), 80% (V80% [cc]), and 100% (V100% [cc]) of the prescribed dose.ResultsHI and CI were comparable between TI-VMAT and the conventional VMAT, the mean brain dose for TI-VMAT with AS defined by a space of 2.0 cm and jaw tracking was 14.27 Gy, which was significantly lower than that for the conventional VMAT (21.20 Gy). In addition, dosimetric parameters such as V20% [cc] were significantly suppressed compared to those for high doses.ConclusionOur proposed irradiation technique TI-VMAT shows the potential to reduce radiation doses in the brain with maintaining higher dose coverage on the PTV.  相似文献   

11.
PurposeTo compare normal tissue complication probability (NTCP) and average doses in the bone marrow (BM), obtained for five different radiotherapy delivery and planning strategies of cervical and endometrial cancer.Material/methods50 patients were taken to analysis. For each case, 3 different dose delivery techniques were used: 4-field, X15MV, 3DCRT; 7-field, X6MV, IMRT; and 2-arc, X6MV, VMAT. Two optimization scenarios were used for the IMRT and VMAT plans generation: with (+) and without (−) the inclusion of the BM as an optimized structure. Average doses and dose-volume histogram parameters for the PTV, BM, bladder, rectum, bowels and femoral heads were compared. In addition, the BM doses were analyzed with respect to the PTV and/or volume of the BM, and NTCP for the BM were computed.ResultsThe dose in PTV for evaluated plans was similar. The worst doses in organs at risk were obtained for 3DCRT. Using the BM during the optimization of IMRT and VMAT reduces an average dose in BM without increasing the doses in the bladder, rectum and bowels. Differences between doses in BM for IMRT(+) and VMAT(+) plans were similar while NTCP was lower for VMAT(+). A correlation between average dose in BM and the volume ratio of BM and PTV was found for each technique.ConclusionUsing the BM during the optimization of the IMRT and VMAT plans effectively reduces the dose in BM without increasing the dose in the bladder, rectum and bowels. The VMAT(+) plans were characterized by the lowest NTCP.  相似文献   

12.
PurposeFlattening filter free (FFF) beams are frequently used for stereotactic body radiation therapy with various treatment modalities: conventional static fields, dynamic conformal arc (DCA) or Rapid Arc (RA). The goal of this study was to obtain some criteria to enable a conscious choice of the employment of FFF beams and of the DCA or RA technique, depending on the PTV size.Methods and materials24 PTVs from 1.52 cm3 to 445.24 cm3 were studied in various sites: virtual phantom, lung and liver. For each PTV, DCA and RA plans were prepared using two flattened (FF) and two unflattened photon beams. Parameters such as conformity index, gradient index, healthy-tissue and organs at risk mean doses, number of monitor units (MU), beam on time (BOT) were used to quantify obtained dose distributions. Friedman tests and Spearman’s rank correlation coefficients were also performed.ResultsNo significant differences were found between FF and FFF beams for RA regarding conformity and gradient indices. For DCA, 10FFF is less suitable and forward planning becomes more challenging as PTV volume increases. FFF beams provided a better sparing of healthy-tissues except for 10FFF used with DCA. 6FFF was slightly better than 10FFF in terms of healthy-tissue mean doses. FFF beams generated significantly reduced BOTs and increased MUs. These effects were more pronounced for larger volumes and especially for RA plans.ConclusionsFFF showed better results than FF beams for the considered plans. 10FFF used with DCA should be used with caution for medium and large volumes.  相似文献   

13.
PurposeThis multi-institution study assessed the positioning accuracy of multileaf collimators (MLC) by analyzing log files. It determined the main machine parameters that affect MLC positioning errors for pre-TrueBeam (Clinac) and TrueBeam linacs.MethodsAround 30,000 dIMRT and VMAT log files belonging to 6 linacs from 4 different centers were analyzed. An in-house software was used to calculate 95th percentile and RMS error values and their correlation with certain parameters such as maximum leaf speed, mean leaf speed and gantry angle. The effect of MLC communication delay on error statistics was assessed in Clinac linacs. To that end MLC positioning error statistics were calculated with and without the delay effect.ResultsFor dIMRT treatments in Clinac linacs the mean leaf RMS error was 0.306 mm with and 0.030 mm without the delay effect. Leaf RMS error was closely linked to maximum and mean leaf speeds, but without the delay effect that link was weaker. No trend was observed between bank RMS error and gantry angle. Without the delay effect larger bank RMS errors were obtained for gantry angles with leaf movements against gravity. For VMAT treatments in TrueBeam linacs the mean leaf RMS error was 0.038 mm. A link was also observed between leaf RMS error and maximum and mean leaf speeds.ConclusionTrueBeam MLC positioning errors are substantially lower than those of Clinac linacs. In Clinac machines the analysis of dynalogs without the delay effect allows us to study the influence of factors that are masked by the delay effect.  相似文献   

14.
PurposeTo study the sensitivity of an ArcCHECK dosimeter in detecting delivery errors during the delivery of Volumetric Modulated Arc Therapy (VMAT).MethodsThree types of errors in Multi Leaf Collimator (MLC) position and dose delivery were simulated separately in the delivery of five prostate and five head and neck (H&N) VMAT plans: (i) Gantry independent: a systematic shift in MLC position and variation in output to the whole arc; (ii) Gantry dependent: sag in MLC position and output variation as a function of gantry angle; (iii) Control point specific MLC and output errors introduced to only a specific number of Control Points (CP). The difference in local and global gamma (γ) pass rate between the no-error and error-simulated measurements with 2%/2 mm and 3%/3 mm tolerances was calculated to assess the sensitivity of ArcCHECK. The clinical impact of these errors was also calculated.ResultsArcCHECK was able to detect a minimum 3 mm MLC error and 3% output error for Gantry independent errors using either local or global gamma with 2%/2 mm tolerance. For the Gantry dependent error scenario a minimum 3 mm MLC error and 3% dose error was identifiable by ArcCHECK using either global or local gamma with 2%/2 mm tolerance. In errors introduced to specific CPs a MLC error of 10 mm and dose error of 100% introduced to 4CPs were detected by ArcCHECK.ConclusionArcCHECK used with either local or global gamma analysis and 2%/2 mm criteria can be confidently used in the clinic to detect errors above the stated error values.  相似文献   

15.
AimTo study the sensitivity of three commercial dosimetric systems, Delta4, Multicube and Octavius4D, in detecting Volumetric Modulated Arc Therapy (VMAT) delivery errors.MethodsFourteen prostate and head and neck (H&N) VMAT plans were considered for this study. Three types of errors were introduced into the original plans: gantry angle independent and dependent MLC errors, and gantry angle dependent dose errors. The dose matrix measured by each detector system for the no-error and error introduced delivery were compared with the reference Treatment Planning System (TPS) calculated dose matrix for no-error plans using gamma (γ) analysis with 2%/2 mm tolerance criteria. The ability of the detector system in identifying the minimum error in each scenario was assessed by analysing the gamma pass rates of no error delivery and error delivery using a Wilcoxon signed-rank test. The relative sensitivity of the system was assessed by determining the slope of the gamma pass line for studied error magnitude in each error scenario.ResultsIn the gantry angle independent and dependent MLC error scenario the Delta4, Multicube and Octavius4D systems detected a minimum 2 mm error. In the gantry angle dependent dose error scenario all studied systems detected a minimum 3% and 2% error in prostate and H&N plans respectively. In the studied detector systems Multicube showed relatively less sensitivity to the errors in the majority of error scenarios.ConclusionThe studied systems identified the same magnitude of minimum errors in all considered error scenarios.  相似文献   

16.
PurposeTo investigate different volumetric modulated arc therapy (VMAT) field designs for lymph node positive breast cancer patients when compared to conventional static fields and standard VMAT designs.MethodsNineteen breast cancer patients with lymph node involvement (eleven left and eight right sided) were retrospectively analyzed with different arc designs. Proposed split arc designs with total rotations of 2 × 190° and 2 × 240° were compared to conventional field in field (FinF) and previously published non-split arc techniques with the same amount of total rotations.ResultsAll VMAT plans were superior in dose conformity, when compared to the FinF plans. Split arc design decreased significantly ipsilateral lung dose and heart V5Gy for both left and right sided cases, when compared to non-split VMAT designs. For left sided cases no significant differences were seen in contralateral lung mean dose or V5Gy between different VMAT designs. For right sided cases the contralateral lung dose V5Gy was significantly higher in split VMAT group, when compared to non-split VMAT designs. The contralateral breast dose V5Gy increased significantly for split VMAT plans for both sides, when compared to non-split VMAT designs or FinF plans.ConclusionsThe proposed split VMAT technique was shown to be superior to previously published non-split VMAT and conventional FinF techniques significantly reducing dose to the ipsilateral lung and heart. However, this came with the expense of an increase in the dose to the contralateral breast and for right-sided cases to the contralateral lung.  相似文献   

17.
PurposeTo perform a comprehensive dosimetric and clinical evaluation of the new Pinnacle Personalized automated planning system for complex head-and-neck treatments.MethodsFifteen consecutive head-neck patients were enrolled. Radiotherapy was prescribed using VMAT with simultaneous integrated boost strategy. Personalized planning integrates the Feasibility engine able to supply an “a priori” DVH prediction of the achievability of planning goals. Comparison between clinically accepted manually-generated (MP) and automated (AP) plans was performed using dose-volume histograms and a blinded clinical evaluation by two radiation oncologists. Planning time between MP and AP was compared. Dose accuracy was validated using the PTW Octavius-4D phantom together with the 1500 2D-array.ResultsFor similar targets coverage, AP plans reported less irradiation of healthy tissue, with significant dose reduction for spinal cord, brainstem and parotids. On average, the mean dose to parotids and maximal doses to spinal cord and brainstem were reduced by 13–15% (p < 0.001), 9% (p < 0.001) and 16% (p < 0.001), respectively. The integral dose was reduced by 16% (p < 0.001). The dose conformity for the three PTVs was significantly higher with AP plans (p < 0.001). The two oncologists chose AP plans in more than 80% of cases. Overall planning times were reduced to <30 min for automated optimization. All AP plans passed the 3%/2 mm γ-analysis by more than 95%.ConclusionComplex head-neck plans created using Personalized automated engine provided an overall increase of plan quality, in terms of dose conformity and sparing of normal tissues. The Feasibility module allowed OARs dose sparing well beyond the clinical objectives.  相似文献   

18.
PurposeTo introduce volumetric modulated arc therapy treatments (VMAT) with simultaneous integrated boost (SIB) for pancreatic cancer and describe dosimetric results on a large patient series.Methods and materials45 patients with pancreatic malignancies were treated with 18 MV single-arc VMAT. Image guidance was performed with daily online kilo-volt cone-beam computed tomography (CBCT). The conformity index (CI) and homogeneity index (HI) to the target volumes, PTV45Gy and PTV54Gy, and dose–volume indices to OARs from the QUANTEC task group were reported. The risk of clinical nephritis was evaluated using normal tissue complication probability (NTCP). Treatments were verified in-phantom with the Delta4 system.ResultsAverage CI was 1.06 with 95% confidence intervals (95% CI) of 0.97–1.22 for PTV45Gy and 1.17 (0.66–1.61) for PTV54Gy. HI of PTV54Gy was 1.06 (1.04–1.10). OAR constraints were achieved in all patients, except for kidneys V12Gy of 48 (35.4–72.3)%. NTCP of the kidneys was 0.98 (0.6–1.7)%. Kidneys V12Gy and V20Gy were inversely related to PTV54Gy CI and maximum dose. All in-phantom tests had gamma pass rates exceeding 95% with global 3% dose difference and 3 mm distance to agreement. Patient shifts measured with CBCT had 95% CI of −0.8, +0.8 in the RL, −0.7, +0.8 in the SI, and −0.8, +0.7 cm in the AP directions.ConclusionsDosimetric results of VMAT were excellent on PTVs and organs at risk. The kidneys represent the dose-limiting organ at risk for this technique. NTCP indicates that this technique is safe from radiation-induced side effects to the kidneys.  相似文献   

19.
AimThe main purpose of this study is to perform a dosimetric comparison on target volumes and organs at risks (OARs) between prostate intensity modulated treatment plans (IMRT) optimized with different multileaf collimators (MLCs).BackgroundThe use of MLCs with a small leaf width in the IMRT optimization may improve conformity around the tumor target whilst reducing the dose to normal tissues.Materials and methodsTwo linacs mounting MLCs with 5 and 10 mm leaf-width, respectively, implemented in Pinnacle3 treatment planning system were used for this work. Nineteen patients with prostate carcinoma undergoing a radiotherapy treatment were enrolled. Treatment planning with different setup arrangements (7 and 5 beams) were performed for each patient and each machine. Dose volume histograms (DVHs) cut-off points were used in the treatment planning comparison.ResultsComparable planning target volume (PTV) coverage was obtained with 7- and 5-beam configuration (both with 5 and 10 mm MLC leaf-width). The comparison of bladder and rectum DVH cut-off points for the 5-beam arrangement shows that 52.6% of the plans optimized with a larger leaf-width did not satisfy at least one of the OARs’ constraints. This percentage is reduced to 10.5% for the smaller leaf-width. If a 7-beam arrangement is used the value of 52.6% decreases to 21.1% while the value of 10.5% remains unchanged.ConclusionMLCs collimators with different widths and number of leaves lead to a comparable prostate treatment planning if a proper adjustment is made of the number of gantry angles.  相似文献   

20.
PurposeTo find the optimal dose weighting for hybrid volumetric modulated arc therapy (H-VMAT), a combination of conventional 3DCRT and VMAT plans for left sided chest wall and supraclavicular radiation therapy.Methods & materials20 left-sided breast cancer patients who received adjuvant radiotherapy were considered for this study. To find the optimal weighting, 5 H-VMAT plans were generated for each study case by combining different dose proportions of 3DCRT and VMAT plans including: 90% 3DCRT/10% VMAT, 80% 3DCRT/20% VMAT, 70% 3DCRT/30% VMAT, 60% 3DCRT/40% VMAT, 50% 3DCRT/50% VMAT. Further field-in-field, optimal H-VMAT and VMAT alone plans were compared.ResultsAll H-VMAT plans achieved the expected target coverage. A higher conformity index was achieved for 50% 3DCRT/50% VMAT plan, while better homogeneity index was achieved for 80% 3DCRT/20% VMAT plan. Mean and low doses were less in 90% 3DCRT/10% VMAT plan. Compared with other proportions, 80% 3DCRT/20% VMAT and 70% 3DCRT/30% VMAT weighted H-VMAT plans achieved balanced results for PTVs and OARs.ConclusionThe optimal dose mixture for H-VMAT technique is 70% to 80% for 3DCRT and 20% to 30% for VMAT. The optimal H-VMAT achieved balanced results for the PTVs and OARs compared with field-in-field and VMAT alone plans.  相似文献   