首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

DNA methylation is an important epigenetic mechanism in several human diseases, most notably cancer. The quantitative analysis of DNA methylation patterns has the potential to serve as diagnostic and prognostic biomarkers, however, there is currently a lack of consensus regarding the optimal methodologies to quantify methylation status. To address this issue we compared five analytical methods: (i) MethyLight qPCR, (ii) MethyLight digital PCR (dPCR), methylation-sensitive and -dependent restriction enzyme (MSRE/MDRE) digestion followed by (iii) qPCR or (iv) dPCR, and (v) bisulfite amplicon next generation sequencing (NGS). The techniques were evaluated for linearity, accuracy and precision.

Results

MethyLight qPCR displayed the best linearity across the range of tested samples. Observed methylation measured by MethyLight- and MSRE/MDRE-qPCR and -dPCR were not significantly different to expected values whilst bisulfite amplicon NGS analysis over-estimated methylation content. Bisulfite amplicon NGS showed good precision, whilst the lower precision of qPCR and dPCR analysis precluded discrimination of differences of < 25% in methylation status. A novel dPCR MethyLight assay is also described as a potential method for absolute quantification that simultaneously measures both sense and antisense DNA strands following bisulfite treatment.

Conclusions

Our findings comprise a comprehensive benchmark for the quantitative accuracy of key methods for methylation analysis and demonstrate their applicability to the quantification of circulating tumour DNA biomarkers by using sample concentrations that are representative of typical clinical isolates.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-15-1174) contains supplementary material, which is available to authorized users.  相似文献   

2.

Introduction

Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent.

Methods

In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed.

Results

There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both.

Conclusions

Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used.  相似文献   

3.

Background

Fluorescence-based methods have been proposed to aid caries lesion detection. Summarizing and analysing findings of studies about fluorescence-based methods could clarify their real benefits.

Objective

We aimed to perform a comprehensive systematic review and meta-analysis to evaluate the accuracy of fluorescence-based methods in detecting caries lesions.

Data Source

Two independent reviewers searched PubMed, Embase and Scopus through June 2012 to identify papers/articles published. Other sources were checked to identify non-published literature.

Study Eligibility Criteria, Participants and Diagnostic Methods

The eligibility criteria were studies that: (1) have assessed the accuracy of fluorescence-based methods of detecting caries lesions on occlusal, approximal or smooth surfaces, in both primary or permanent human teeth, in the laboratory or clinical setting; (2) have used a reference standard; and (3) have reported sufficient data relating to the sample size and the accuracy of methods.

Study Appraisal and Synthesis Methods

A diagnostic 2×2 table was extracted from included studies to calculate the pooled sensitivity, specificity and overall accuracy parameters (Diagnostic Odds Ratio and Summary Receiver-Operating curve). The analyses were performed separately for each method and different characteristics of the studies. The quality of the studies and heterogeneity were also evaluated.

Results

Seventy five studies met the inclusion criteria from the 434 articles initially identified. The search of the grey or non-published literature did not identify any further studies. In general, the analysis demonstrated that the fluorescence-based method tend to have similar accuracy for all types of teeth, dental surfaces or settings. There was a trend of better performance of fluorescence methods in detecting more advanced caries lesions. We also observed moderate to high heterogeneity and evidenced publication bias.

Conclusions

Fluorescence-based devices have similar overall performance; however, better accuracy in detecting more advanced caries lesions has been observed.  相似文献   

4.

Background

Real-Time quantitative PCR is an important tool in research and clinical settings. Here, we describe two new approaches that broaden the scope of real-time quantitative PCR; namely, run-internal mini standard curves (RIMS) and direct real-time relative quantitative PCR (drqPCR). RIMS are an efficient alternative to traditional standard curves and provide both run-specific and target-specific estimates of PCR parameters. The drqPCR enables direct estimation of target ratios without reference to conventional control samples.

Methodology/Principal Findings

In this study, we compared RIMS-based drqPCR with classical quantifications based on external standard curves and the “comparative Ct method”. Specifically, we used a raw real-time PCR dataset as the basis for more than two-and-a-half million simulated quantifications with various user-defined conditions. Compared with classical approaches, we found that RIMS-based drqPCR provided superior precision and comparable accuracy.

Conclusions/Significance

The obviation of referencing to control samples is attractive whenever unpaired samples are quantified. This may be in clinical and research settings; for instance, studies on chimerism, TREC quantifications, copy number variations etc. Also, lab-to-lab comparability can be greatly simplified.  相似文献   

5.

Purpose

To investigate the effect of ageing on visuomotor function and subsequently evaluate the effect of visual field loss on such function in older adults.

Methods

Two experiments were performed: 1) to determine the effect of ageing on visual localisation and subsequent pointing precision, and 2) to determine the effect of visual field loss on these outcome measures. For Experiment 1, we measured visual localisation and pointing precision radially at visual eccentricities of 5, 10 and 15° in 25 older (60–72 years) and 25 younger (20–31 years) adults. In the pointing task, participants were asked to point to a target on a touchscreen at a natural pace that prioritised accuracy of the touch. In Experiment 2, a subset of these tasks were performed at 15° eccentricity under both monocular and binocular conditions, by 8 glaucoma (55–76 years) and 10 approximately age-matched controls (61–72 years).

Results

Visual localisation and pointing precision was unaffected by ageing (p>0.05) and visual field loss (p>0.05), although movement time was increased in glaucoma (p = 0.01).

Conclusion

Visual localisation and pointing precision to high contrast stimuli within the central 15° of vision are unaffected by ageing. Even in the presence of significant visual field loss, older adults with glaucoma are able perform such tasks with reasonable precision provided the target can be perceived and movement time is not restricted.  相似文献   

6.

Background and Aims

From Darwin''s time onward, biologists have thought about adaptation as evolution toward optimal trait values, but they have not usually assessed the relative importance of the distinct causes of deviations from optima. This problem is investigated here by measuring adaptive inaccuracy (phenotypic deviation from the optimum), using flower pollination as an adaptive system.

Methods

Adaptive accuracy is shown to have at least three distinct components, two of which are optimality (deviation of the mean from the optimum) and precision (trait variance). We then describe adaptive accuracy of both individuals and populations. Individual inaccuracy comprises the deviation of the genotypic target (the mean phenotype of a genotype grown in a range of environments) from the optimum and the phenotypic variation around that genotypic target (phenotypic imprecision). Population inaccuracy has three basic components: deviation of the population mean from the optimum, variance in the genotypic targets and phenotypic imprecision. In addition, a fourth component is proposed, namely within-population variation in the optimum. These components are directly estimable, have additive relationships, and allow exploration of the causes of adaptive inaccuracy of both individuals and populations. Adaptive accuracy of a sample of flowers is estimated, relating floral phenotypes controlling pollen deposition on pollinators to adaptive optima defined as the site most likely to get pollen onto stigmas (male inaccuracy). Female inaccuracy is defined as the deviation of the position of stigma contact from the expected location of pollen on pollinators.

Key Results

A surprising amount of variation in estimated accuracy within and among similar species is found. Some of this variation is generated by developmental changes in positions of stigmas or anthers during anthesis (the floral receptive period), which can cause dramatic change in accuracy estimates. There seem to be trends for higher precision and accuracy in flowers with higher levels of integration and dichogamy (temporal separation of sexual functions), and in those that have pollinators that are immobile (or immobilized) during pollen transfer. Large deviations from putative adaptive optima were observed, and these may be related to the effects of conflicting selective pressures on flowers, such as selection against self-pollination promoting herkogamy (spatial separation of pollen and stigmas).

Conclusions

Adaptive accuracy is a useful concept for understanding the adaptive significance of phenotypic means and variances of floral morphology within and among populations and species. Estimating and comparing the various components of adaptive accuracy can be particularly helpful for identifying the causes of inaccuracy, such as conflicting selective pressures, low environmental canalization and developmental instability.Key words: Adaptive accuracy, Collinsia, Dalechampia, fitness, floral precision, Linum, optimality, pollination, Stylidium  相似文献   

7.

Background

Our knowledge of global protein-protein interaction (PPI) networks in complex organisms such as humans is hindered by technical limitations of current methods.

Results

On the basis of short co-occurring polypeptide regions, we developed a tool called MP-PIPE capable of predicting a global human PPI network within 3 months. With a recall of 23% at a precision of 82.1%, we predicted 172,132 putative PPIs. We demonstrate the usefulness of these predictions through a range of experiments.

Conclusions

The speed and accuracy associated with MP-PIPE can make this a potential tool to study individual human PPI networks (from genomic sequences alone) for personalized medicine.

Electronic supplementary material

The online version of this article (doi:10.1186/s12859-014-0383-1) contains supplementary material, which is available to authorized users.  相似文献   

8.

Background and Objectives

Access to antiretroviral treatment among adolescents living with HIV (ALH) is increasing. Health-related quality of life (HRQOL) is relevant for monitoring the impact of the disease on both well-being and treatment outcomes. However, adequate screening tools to assess HRQOL in low-resource settings are scarce. This study aims to fill this research gap, by 1) assessing the psychometric properties and reliability of an Eastern African English version of a European HRQOL scale for adolescents (KIDSCREEN) and 2) determining which version of the KIDSCREEN (52-, 27- and 10-item version) is most suitable for low-resource settings.

Methods

The KIDSCREEN was translated into Eastern African English, Luganda (Uganda) and Dholuo (Kenya) according to standard procedures. The reconciled version was administered in 2011 to ALH aged 13–17 in Kenya (n = 283) and Uganda (n = 299). All three KIDSCREEN versions were fitted to the data with confirmatory factor analysis (CFA). After comparison, the most suitable version was adapted based on the CFA outcomes utilizing the results of previous formative research. In order to develop a general HRQOL factor, a second-order measurement model was fitted to the data.

Results

The CFA results showed that without adjustments, the KIDSCREEN cannot be used for measuring the HRQOL of HIV-positive adolescents. After comparison, the most suitable version for low-resource settings - the 27-item version - was adapted further. The introduction of a negative wording factor was required for the Dholuo model. The Dholuo (CFI: 0.93; RMSEA: 0.039) and the Luganda model (CFI: 0.90; RMSEA: 0.052) showed a good fit. All cronbach’s alphas of the factors were 0.70 or above. The alpha value of the Dholuo and Lugandan HRQOL second-order factor was respectively 0.84 and 0.87.

Conclusions

The study showed that the adapted KIDSCREEN-27 is an adequate tool for measuring HRQOL in low-resource settings with high HIV prevalence.  相似文献   

9.

Background

Linear regression of efficiency or LRE introduced a new paradigm for conducting absolute quantification, which does not require standard curves, can generate absolute accuracies of ±25% and has single molecule sensitivity. Derived from adapting the classic Boltzmann sigmoidal function to PCR, target quantity is calculated directly from the fluorescence readings within the central region of an amplification profile, generating 4–8 determinations from each amplification reaction.

Findings

Based on generating a linear representation of PCR amplification, the highly visual nature of LRE analysis is illustrated by varying reaction volume and amplification efficiency, which also demonstrates how LRE can be used to model PCR. Examining the dynamic range of LRE further demonstrates that quantitative accuracy can be maintained down to a single target molecule, and that target quantification below ten molecules conforms to that predicted by Poisson distribution. Essential to the universality of optical calibration, the fluorescence intensity generated by SYBR Green I (FU/bp) is shown to be independent of GC content and amplicon size, further verifying that absolute scale can be established using a single quantitative standard. Two high-performance lambda amplicons are also introduced that in addition to producing highly precise optical calibrations, can be used as benchmarks for performance testing. The utility of limiting dilution assay for conducting platform-independent absolute quantification is also discussed, along with the utility of defining assay performance in terms of absolute accuracy.

Conclusions

Founded on the ability to exploit lambda gDNA as a universal quantitative standard, LRE provides the ability to conduct absolute quantification using few resources beyond those needed for sample preparation and amplification. Combined with the quantitative and quality control capabilities of LRE, this kinetic-based approach has the potential to fundamentally transform how real-time qPCR is conducted.  相似文献   

10.

Background

Effective prevention of excessive alcohol use has the potential to reduce the public burden of disease considerably. We investigated the cost-effectiveness of Screening and Brief Intervention (SBI) for excessive alcohol use in primary care in the Netherlands, which is targeted at early detection and treatment of ‘at-risk’ drinkers.

Methodology and Results

We compared a SBI scenario (opportunistic screening and brief intervention for ‘at-risk’ drinkers) in general practices with the current practice scenario (no SBI) in the Netherlands. We used the RIVM Chronic Disease Model (CDM) to extrapolate from decreased alcohol consumption to effects on health care costs and Quality Adjusted Life Years (QALYs) gained. Probabilistic sensitivity analysis was employed to study the effect of uncertainty in the model parameters. In total, 56,000 QALYs were gained at an additional cost of €298,000,000 due to providing alcohol SBI in the target population, resulting in a cost-effectiveness ratio of €5,400 per QALY gained.

Conclusion

Prevention of excessive alcohol use by implementing SBI for excessive alcohol use in primary care settings appears to be cost-effective.  相似文献   

11.

Objective

Infancy is a critical period during which rapid growth potentially programs future disease risk. Identifying the modifiable determinants of growth is therefore important. To capture the complexity of infant growth, we modeled growth trajectories from birth to six months in order to compare the genetic and environmental influences on growth trajectory parameters with single time-point measures at birth, three and six months of age.

Methods

Data were from Gemini, a population sample of 2402 UK families with twins. An average 10 weight measurements per child made by health professionals were available over the first six months. Weights at birth, three and six months were identified. Longitudinal growth trajectories were modeled using SITAR utilizing all available weight measures for each child. SITAR generates three parameters: size (characterizing mean weight throughout infancy), tempo (indicating age at peak weight velocity (PWV)), and velocity (reflecting the size of PWV). Genetic and environmental influences were estimated using quantitative genetic analysis.

Results

In line with previous studies, heritability of weight at birth and three months was low (38%), but it was higher at six months (62%). Heritability of the growth trajectory parameters was high for size (69%) and velocity (57%), but low (35%) for tempo. Common environmental influences predominated for tempo (42%).

Conclusion

Modeled growth parameters using SITAR indicated that size and velocity were primarily under genetic influence but tempo was predominantly environmentally determined. These results emphasize the importance of identifying specific modifiable environmental determinants of the timing of peak infant growth.  相似文献   

12.

Aim

Stepping source in brachytherapy systems is used to treat a target lesion longer than the effective treatment length of the source. Cancerous lesions in the cervix, esophagus and rectum are examples of such a target lesion.

Background

In this study, the stepping source of a GZP6 afterloading intracavitary brachytherapy unit was simulated using Monte Carlo (MC) simulation and the results were used for the validation of the GZP6 treatment planning system (TPS).

Materials and methods

The stepping source was simulated using MCNPX Monte Carlo code. Dose distributions in the longitudinal plane were obtained by using a matrix shift method for esophageal tumor lengths of 8 and 10 cm. A mesh tally has been employed for the absorbed dose calculation in a cylindrical water phantom. A total of 5 × 108 photon histories were scored and the MC statistical error obtained was at the range of 0.008–3.5%, an average of 0.2%.

Results

The acquired MC and TPS isodose curves were compared and it was shown that the dose distributions in the longitudinal plane were relatively coincidental. In the transverse direction, a maximum dose difference of 7% and 5% was observed for tumor lengths of 8 and 10 cm, respectively.

Conclusion

Considering that the certified source activity is given with ±10% uncertainty, the obtained difference is reasonable. It can be concluded that the accuracy of the dose distributions produced by GZP6 TPS for the stepping source is acceptable for its clinical applications.  相似文献   

13.

Background

Current quantification methods for mass spectrometry (MS)-based proteomics either do not provide sufficient control of variability or are difficult to implement for routine clinical testing.

Results

We present here an integrated quantification (InteQuan) method that better controls pre-analytical and analytical variability than the popular quantification method using stable isotope-labeled standard peptides (SISQuan). We quantified 16 lung cancer biomarker candidates in human plasma samples in three assessment studies, using immunoaffinity depletion coupled with multiple reaction monitoring (MRM) MS. InteQuan outperformed SISQuan in precision in all three studies and tolerated a two-fold difference in sample loading. The three studies lasted over six months and encountered major changes in experimental settings. Nevertheless, plasma proteins in low ng/ml to low μg/ml concentrations were measured with a median technical coefficient of variation (CV) of 11.9% using InteQuan. The corresponding median CV using SISQuan was 15.3% after linear fitting. Furthermore, InteQuan surpassed SISQuan in measuring biological difference among clinical samples and in distinguishing benign versus cancer plasma samples.

Conclusions

We demonstrated that InteQuan is a simple yet robust quantification method for MS-based quantitative proteomics, especially for applications in biomarker research and in routine clinical testing.

Electronic supplementary material

The online version of this article (doi:10.1186/1559-0275-12-3) contains supplementary material, which is available to authorized users.  相似文献   

14.

Background

Trust in health care has been intensely researched in resource rich settings. Some studies in resource poor settings suggest that the dimensions and determinants of trust are likely to be different.

Objectives

This study was done as a qualitative exploration of the dimensions and determinants of trust in health care in Tamil Nadu, a state in south India to assess the differences from dimensions and determinants in resource rich settings.

Methodology

The participants included people belonging to marginalized communities with poor access to health care services and living in conditions of resource deprivation. A total of thirty five in depth interviews were conducted. The interviews were summarized and transcribed and data were analyzed following thematic analysis and grounded theory approach.

Results

The key dimensions of trust in health care identified during the interviews were perceived competence, assurance of treatment irrespective of ability to pay or at any time of the day, patients’ willingness to accept drawbacks in health care, loyalty to the physician and respect for the physician. Comfort with the physician and health facility, personal involvement of the doctor with the patient, behavior and approach of doctor, economic factors, and health awareness were identified as factors determining the levels of trust in health care.

Conclusions

The dimensions and determinants of trust in health care in resource poor settings are different from that in resource rich settings. There is a need to develop scales to measure trust in health care in resource poor settings using these specific dimensions and determinants.  相似文献   

15.
16.

Background

Isoflurane in clinical use is a racemate of S- and R-isoflurane. Previous studies have demonstrated that the effects of S-isoflurane on relevant anesthetic targets might be modestly stronger (less than 2-fold) than R-isoflurane. The X-ray crystallographic structure of the immunological target, leukocyte function-associated antigen-1 (LFA-1) with racemic isoflurane suggested that only S-isoflurane bound specifically to this protein. If so, the use of specific isoflurane enantiomers may have advantage in the surgical settings where a wide range of inflammatory responses is expected to occur. Here, we have further tested the hypothesis that isoflurane enantioselectivity is apparent in solution binding and functional studies.

Methods

First, binding of isoflurane enantiomers to LFA-1 was studied using 1-aminoanthracene (1-AMA) displacement assays. The binding site of each enantiomer on LFA-1 was studied using the docking program GLIDE. Functional studies employed the flow-cytometry based ICAM binding assay.

Results

Both enantiomers decreased 1-AMA fluorescence signal (at 520 nm), indicating that both competed with 1-AMA and bound to the αL I domain. The docking simulation demonstrated that both enantiomers bound to the LFA-1 “lovastatin site.” ICAM binding assays showed that S-isoflurane inhibited more potently than R-isoflurane, consistent with the result of 1-AMA competition assay.

Conclusions

In contrast with the x-ray crystallography, both enantiomers bound to and inhibited LFA-1. S-isoflurane showed slight preference over R-isoflurane.  相似文献   

17.

Background

Data on incidence of coronary heart disease (CHD) is scarce in the Middle East and little is known about the contribution of known risk factors in this area.

Methods

The incidence of CHD and the effect of modifiable risk factors were explored in 2889 men and 3803 women aged 30–74 years in the population based cohort of the Tehran Lipid and Glucose Study, during 1999–2010. Average population attributable fraction (aPAF) was calculated for any risk factor using direct method based on regression model.

Results

The crude incidence rate in men was about twice that in women (11.9 vs. 6.5 per 1000 person-years). The aPAF of hypertension, diabetes, high total cholesterol and low-HDL cholesterol was 9.4%, 6.7%, 7.3% and 6.1% in men and 17%, 16.6%, 12% and 4.6% in women respectively. This index was 7.0% for smoking in men. High risk age contributed to 42% and 22% of risk in men and women respectively.

Conclusions

The incidence in this population of Iran was comparable to those in the US in the seventies. Well known modifiable risk factors explained about 40% and 50% of CHD burden in men and women respectively. Aging, as a reflection of unmeasured or unknown risk factors, bears the most burden of CHD, especially in men; indicating more age-related health care is required.  相似文献   

18.

Background

The quality of colonoscopies performed by primary care physicians (PCPs) is unknown.

Objective

To determine whether PCP colonoscopists achieve colonoscopy quality benchmarks, and patient satisfaction with having their colonoscopy performed by a primary care physician.

Design

Prospective multi-center, multi-physician observational study. Colonoscopic quality data collection occurred via completion of case report forms and pathological confirmation of lesions. Patient satisfaction was captured by a telephone survey.

Setting

Thirteen rural and suburban hospitals in Alberta, Canada.

Measurements

Proportion of successful cecal intubations, average number of adenomas detected per colonoscopy, proportion of patients with at least one adenoma, and serious adverse event rates; patient satisfaction with their wait time and procedure, as well as willingness to have a repeat colonoscopy performed by their primary care endoscopist.

Results

In the two-month study period, 10 study physicians performed 577 colonoscopies. The overall adjusted proportion of successful cecal intubations was 96.5% (95% CI 94.6–97.8), and all physicians achieved the adjusted cecal intubation target of ≥90%. The average number of ademonas detected per colonoscopy was 0.62 (95% CI 0.5–0.74). 46.4% (95% CI 38.5–54.3) of males and 30.2% (95% CI 22.3–38.2) of females ≥50 years of age having their first colonoscopy, had at least one adenoma. Four serious adverse events occurred (three post polypectomy bleeds and one perforation) and 99.3% of patients were willing to have a repeat colonoscopy performed by their primary care colonoscopist.

Limitations

Two-month study length and non-universal participation by Alberta primary care endoscopists.

Conclusions

Primary care physician colonoscopists can achieve quality benchmarks in colonoscopy. Training additional primary care physicians in endoscopy may improve patient access and decrease endoscopic wait times, especially in rural settings.  相似文献   

19.

Background and Objective

Several studies on diagnostic accuracy of pleural N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) for effusions from congestive heart failure (CHF) conclude that pleural NT-pro-BNP is a useful biomarker with high diagnostic accuracy for distinguishing CHF effusions. However, its applicability in critical care settings remains uncertain and requires further investigations.

Methods

NT-proBNP was measured in pleural fluid samples of a prospective cohort of intensive care unit patients with pleural effusions. Receiver operating characteristic curve analysis was performed to determine diagnostic accuracy of pleural NT-proBNP for prediction of CHF effusions.

Results

One hundred forty-seven critically ill patients were evaluated, 38 (26%) with CHF effusions and 109 (74%) with non-CHF effusions of various causes. Pleural NT-proBNP levels were significantly elevated in patients with CHF effusions. Pleural NT-pro-BNP demonstrated the area under the curve of 0.87 for diagnosing effusions due to CHF. With a cutoff of 2200 pg/mL, pleural NT-proBNP displayed high sensitivity (89%) but moderate specificity (73%). Notably, 29 (27%) of 109 patients with non-CHF effusions had pleural NT-proBNP levels >2200 pg/mL and these patients were more likely to experience septic shock (18/29 vs. 10/80, P<0.001) or acute kidney injury (19/29 vs. 9/80, P<0.001).

Conclusions

Among critically ill patients, pleural NT-proBNP measurements remain a useful diagnostic aid in evaluation of pleural effusions. However, patients with non-CHF effusions may exhibit high pleural NT-proBNP concentrations if they suffer from septic shock or acute kidney injury. Accordingly, it is suggested that clinical context should be taken into account when interpreting pleural NT-proBNP values in critical care settings.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号