首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
2.
A new method for the detection of β2 adrenergic agonists was developed based on the chemiluminescence (CL) reaction of β2 adrenergic agonist with potassium ferricyanide–luminol CL. The effect of β2 adrenergic agonists including isoprenaline hydrochloride, salbutamol sulfate, terbutaline sulfate and ractopamine on the CL intensity of potassium ferricyanide–luminol was discovered. Detection of the β2 adrenergic agonist was carried out in a flow system. Using uniform design experimentation, the influence factors of CL were optimized. The optimal experimental conditions were 1 mmol/L of potassium ferricyanide, 10 µmol/L of luminol, 1.2 mmol/L of sodium hydroxide, a flow speed of 2.6 mL/min and a distance of 1.2 cm from ‘Y2’ to the flow cell. The linear ranges and limit of detection were 10–100 and 5 ng/mL for isoprenaline hydrochloride, 20–100 and 5 ng/mL for salbutamol sulfate, 8–200 and 1 ng/mL for terbutaline sulfate, 20–100 and 4 ng/mL for ractopamine, respectively. The proposed method allowed 200 injections/h with excellent repeatability and precision. It was successfully applied to the determination of three β2 adrenergic agonists in commercial pharmaceutical formulations with recoveries in the range of 96.8–98.5%. The possible CL reaction mechanism of potassium ferricyanide–luminol–β2 adrenergic agonist was discussed from the UV/vis spectra. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft‐lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three‐inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 µm wide, 250 µm deep and 82 mm long microchannel. An enhanced CL system, luminol–ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol–ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14–55.0 ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2 ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10 ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A simple and green flow injection chemiluminescence (FI‐CL) method for determination of the fungicide azoxystrobin was described for the first time. CL signal was generated when azoxystrobin was injected into a mixed stream of luminol and KMnO4. The CL signal of azoxystrobin could be greatly improved when an off‐line ultrasonic treatment was adopted. Meanwhile, the signal intensity increases with the analyte concentration proportionally. Several variables, such as the ultrasonic parameters, flow rate of reagents, concentrations of sodium hydroxide solution and CL reagents (potassium permanganate, luminol) were investigated, and the optimal CL conditions were obtained. Under optimal conditions, the linear range of 1–100 ng/mL for azoxystrobin was obtained and the detection limit (3σ) was determined as 0.13 ng/mL. The relative standard deviation was 1.5% for 10 consecutive measurements of 20 ng/mL azoxystrobin. The method has been applied to the determination of azoxystrobin residues in water samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A simple and sensitive chemiluminescence (CL) method was developed for the determination of citalopram in pharmaceutical preparations and human plasma. The method is based on the enhancement of the weak CL signal of the luminol–H2O2 system. It was found that the CL signal arising from the reaction between alkaline luminol and H2O2 was greatly increased by the addition of silver nanoparticles in the presence of citalopram. Prepared silver nanoparticles (AgNPs) were characterized by UV–visible spectroscopy and transmission electron microscopy (TEM). Various experimental parameters affecting CL intensity were studied and optimized for the determination of citalopram. Under optimized experimental conditions, CL intensity was found to be proportional to the concentration of citalopram in the range 40–2500 ng/mL, with a correlation coefficient of 0.9997. The limit of detection (LOD) and limit of quantification (LOQ) of the devised method were 3.78 and 12.62 ng/mL, respectively. Furthermore, the developed method was found to have excellent reproducibility with a relative standard deviation (RSD) of 3.65% (n = 7). Potential interference by common excipients was also studied. The method was validated statistically using recovery studies and was successfully applied to the determination of citalopram in the pure form, in pharmaceutical preparations and in spiked human plasma samples. Percentage recoveries were found to range from 97.71 to 101.99% for the pure form, from 97.84 to 102.78% for pharmaceutical preparations and from 95.65 to 100.35% for spiked human plasma. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
CdS nanoparticles (CdS NPs) of different sizes were synthesized by the citrate reduction method. It was found that CdS NPs could enhance the chemiluminescence (CL) of the luminol‐potassium ferricyanide system and baicalin could inhibit CdS NPs‐enhanced luminol‐potassium ferricyanide CL signals in alkaline solution. Based on this inhibition, a flow‐injection CL method was established for determination of baicalin in pharmaceutical preparations and human urine samples. Under optimized conditions, the linear range for determination of baicalin was 5.0 x 10?6 to 1.0 x 10?3 g/L. The detection limit at a signal‐to‐noise ratio of 3 was 1.7 x 10 ?6 g/L. CL spectra, UV‐visible spectra and transmission electron microscopy (TEM) were used to investigate the CL mechanism. The method described is simple, selective and obviates the need of extensive sample pretreatment. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Sensitive determination of synephrine by flow-injection chemiluminescence.   总被引:2,自引:0,他引:2  
It was found that light emission produced by the oxidation of luminol by potassium ferricyanide in basic medium was enhanced by synephrine, an anti-obesity drug. The optimum conditions for this chemiluminescent reaction were studied in detail in a flow injection system and employed in a new, simple and rapid method for the determination of synephrine. A mechanism for this reaction is proposed, based on the chemiluminescence reaction spectra. In the optimum conditions, CL intensity is proportional to concentration of synephrine in the 0.008-1 microg/mL range. The limit of detection is 1.6 ng/mL for synephrine (3sigma), and the relative standard deviation (n = 11) is 2.6% for 0.5 microg/mL synephrine. The method was applied to the determination of synephrine in herbal products, citrus fruit and biological fluids. The recoveries were satisfactory (90-102%). The results given by the proposed method are in good agreement with those given by HPLC-UV.  相似文献   

8.
A new flow injection method for the determination of folic acid is described. A fast oxidation reaction occurred when folic acid was mixed with potassium ferricyanide generating ferrocyanide which then inhibited the chemiluminescent reaction of ferricyanide and luminol in alkaline medium. The decrease of chemiluminescence intensity was correlated with the folic acid concentration in the range 0.1-21 microg/mL; the detection limit for the assay was 0.03 microg/mL (3sigma). A complete analysis of folic acid, including sampling and washing, could be performed within 2 min with a relative standard deviation of less than 4.0%. The proposed method has been applied successfully to the determination of folic acid in pharmaceutical preparations.  相似文献   

9.
This study presents the first analytical application of the luminol chemiluminescence (CL) reaction for the sensitive detection of carbamate residues. Some experiments have been carried out to check the influence of the presence of traces of a N-methylcarbamate (carbaryl) on the CL emission produced from the oxidation of luminol using different oxidants, showing a significant enhancing effect on the CL emission when the oxidation of luminol is produced by potassium permanganate in alkaline medium, this enhancement being proportional to the carbaryl concentration. This fact has permitted the establishment of a sensitive chemiluminescence flow-injection (CL-FIA) method for the direct determination of carbaryl. The optimization of instrumental and chemical variables influencing the CL response has been carried out by applying experimental designs. Under the optimal conditions, the CL intensity was linear for a carbaryl concentration over the range 5-100 ng/mL with a detection limit of 4.9 ng/mL. This luminol-KMnO4-based FIA-CL system in basic medium shows an easy, fast and cheap alternative detection mode for the analysis of carbaryl residues in environmental water samples.  相似文献   

10.
Based on the inhibition effect of transferrin (Tf) on the reaction of the luminol–hydrogen peroxide (H2O2) chemiluminescence (CL) system, catalysed by meso‐tetra‐(3‐methoxyl‐4‐hydroxyl) phenyl manganese porphyrin (MnP) as a mimetic enzyme of peroxides, a sensitive flow‐injection CL method has been developed for the determination of Tf in an alkaline medium. The CL reaction was carefully investigated by examining the variations of reaction conditions. Under optimum conditions, the linear range for the determination of transferrin was 0.04–20.0 μg/mL and the detection limit was 1.62 ng/mL. This proposed method was sensitive, convenient and simple, and has been successfully applied to the determination of transferrin in a serum sample. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
A novel flow‐injection chemiluminescence (FI‐CL) method is described for the determination of 2‐methoxyestradiol (2‐ME). The method is based on the inhibitory effect of 2‐ME on the CL reaction of luminol and potassium ferricyanide in alkaline solution. Under optimal conditions, net CL intensity was proportional to 2‐ME concentration in synthetic and mouse plasma samples. Corresponding linear regression equations were 8.0 x 10‐9‐1.0 x 10‐7g/mL for synthetic samples and 2.0 x 10‐9‐1.0 x 10‐7g/mL for plasma samples. Detection limit for synthetic samples and limits for quantification of plasma samples were 8.4 x 10‐10g/mL (3σ) for synthetic samples and 4.0 x 10‐9g/mL for mouse samples. A complete analysis was performed for 60 s, including washing and sampling, resulting in a throughput of ≈ 60/h. The proposed method was applied for the determination of 2‐ME in synthetic and mouse plasma samples. Percentage recoveries were 101.0‐102.8% and 98.0‐105.0%, respectively. A possible mechanism responsible for CL reaction is proposed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
A novel flow injection chemiluminescence method for the determination of orciprenaline was developed. The method is based on the chemiluminescence (CL) reaction of orciprenaline with potassium ferricyanide in sodium hydroxide medium, sensitized by the fluorescent dye rhodamine 6G. The proposed procedure allows quantitation of orciprenaline in the concentration range 0.01-1.2 microg/mL, with a detection limit of 7.2 x 10(-3) microg/mL. The relative standard deviation (RSD) is 2.7% for 0.1 microg/mL orciprenaline (n = 9). The sampling frequency was calculated at approximately 120/h. The method was successfully applied to the determination of orciprenaline in pharmaceutical preparations. A brief discussion on the possible CL reaction mechanism is presented.  相似文献   

13.
《Luminescence》2002,17(3):165-167
A new flow injection chemiluminescence method is described for the determination of captopril. It is based on the enhancing effect of captopril on the chemiluminescence reaction of luminol with potassium ferricyanide in alkaline solution in the presence of potassium ferrocyanide. The method allows the determination of captopril over 0.1–40 µg/mL range, with a relative standard deviation (SD) of 1.0% for the determination of 0.5 µg/mL captopril solution in 11 repeated measurements. The method was satisfactorily applied to the determination of captopril in commercial captopril tablets. The possible reaction mechanism is also discussed briefly. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid and sensitive chemiluminescence (CL) method using flow injection analysis is described for the determination of four catecholamines, dopamine, adrenaline, isoprenaline and noradrenaline, based on their greatly enhancing effects on the CL reaction of luminol-potassium periodate in basic solutions. The optimized chemical conditions for the chemiluminescence reaction were 1.0 x 10(-4) mol/L luminol and 1.0 x 10(-5) mol/L potassium periodate in 0.2 mol/L sodium hydroxide (NaOH). Under the optimized conditions, the calibration graphs relating the CL signal intensity (peak height) to the concentration of the analytes were curvilinear and they were suitable for determining dopamine, adrenaline, isoprenaline, and noradrenaline in the range 0.1-10 ng/mL, 0.1-100 ng/mL, 1-100 ng/mL and 5-50 ng/mL, respectively, with the relative standard deviations of 0.8-1.7%. The detection limits of the method are 0.02 ng/mL for dopamine, 0.01 ng/mL for adrenaline, 0.1 ng/mL for isoprenaline and 2.0 ng/mL for noradrenaline. The sampling frequency was calculated to be about 60/h. The selectivity of the method was good, because a series of common ions or excipients, such as K(+), Ba(2+), CO(3)(2-), NO(3)(-), SO(4)(2-), PO(4)(3-), sodium citrate, sodium bisulphite, oxidate dopamine, starch, lactose, carbamide and gelatin, could not produce interference when their concentrations were 1000-fold than those of dopamine. The present method was successfully applied to the determination of the four catecholamines in pharmaceutical injections.  相似文献   

15.
A strong chemiluminescence (CL) response is observed when potassium permanganate solution is injected into basic luminol solution. When the CL reaction terminates, subsequent injection of Hg2+ solution into the reaction mixture results in a new CL reaction. Based on the post-catalytic enhancement effect of Hg2+ on the potassium permanganate-luminol system in basic media, a fast and simple CL-coupled flow injection analysis for the determination of Hg2+ was developed. In optimum conditions, CL intensity is proportional to Hg2+ concentration over the range 1.0 x 10(-8)-1.0 x 10(-5) g/mL, with a detection limit of 2.0 x 10(-9) g/mL. The relative standard deviation (RSD) is 3.6% for 1.0 x 10(-7) g/mL Hg2+ (n = 11). After pretreatment with sulphydryl cotton fibre, environmental water samples were analysed by the proposed method for total mercury determination with satisfactory results. The results were in good agreement with those given by hydride generation-cold vapour atomic absorption spectrometry (HG-CVAAS).  相似文献   

16.
A chemiluminescent method for the determination of riboflavin is described. The method is based on the chemiluminescence (CL) generated during the oxidation of luminol by N-bromosuccinimide (NBS) and N-chlorosuccinimide (NCS) in alkaline medium. It was found that riboflavin could greatly enhance this CL intensity when present in the luminol solution. Based on this observation, a new flow-injection CL method for the determination of riboflavin is proposed in this paper. The detection limits were 7.5 ng/mL and 3.5 ng/mL of riboflavin for the NBS- and NCS-luminol CL systems, respectively. The relative CL intensity was linear, with riboflavin concentration in the range 19-600 ng/mL and 600-2000 ng/mL for the NBS-luminol CL system, and 12-200 ng/mL and 200-2000 ng/mL for the NCS-luminol CL system. The results obtained for the assay of pharmaceutical preparations compared well with those obtained by the official method and demonstrated good accuracy and precision.  相似文献   

17.
In this article, a DPPH·–luminol chemiluminescence (CL) system was reported and the CL mechanism was discussed according to the CL kinetic properties after sequence injecting DPPH· into the DPPH·–luminol reaction mixture. It was observed that scutellarin could inhibit the CL response of the DPPH·–luminol system. Based on this observation, a simple and rapid flow injection CL method was developed for the determination of scutellarin using the inhibition effect in alkaline medium. The optimized chemical conditions for the CL reaction were 5 × 10?6 mol/L DPPH · and 1.0 × 10?4 mol/L luminol in 0.01 mol/L NaOH. Under optimized conditions, the CL intensity was inversely proportional to the concentration of scutellarin over the ranges 5–2000 and 40–3200 ng/ml in pharmaceutical injection and rat plasma, respectively. The limits of detection (S/N  = 3) were 5 and 40 ng/ml in preparations and rat plasma, respectively. Furthermore, the precision, recovery and stability of the validated method were acceptable for the determination of scutellarin in both pharmaceutical injections and rat plasma. The presented method was successfully applied in the determination of scutellarin in pharmaceutical injections and real rat plasma samples.  相似文献   

18.
The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen‐containing reactant intermediates (O2?? and OH?) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow‐injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10?8 to 1.0 × 10?5 g/mL with a detection limit of 2.8 × 10?9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.  相似文献   

19.
A highly sensitive and simple method for identifying sulpiride in pharmaceutical formulations and biological fluids is presented. The method is based on increased chemiluminescence (CL) intensity of a luminol–H2O2 system in response to the addition of Cr (III) under alkaline conditions. The CL intensity of the luminol–H2O2–Cr (III) system was greatly enhanced by the addition of sulpiride and the CL intensity was proportional to the concentration of sulpiride in a sample solution. Various parameters affecting the CL intensity were systematically investigated and optimized for determination of the sulpiride in a sample. Under the optimum conditions, the CL intensity was proportional to the concentration of sulpiride in the range of 0.068–4.0 µg/mL, with a good correlation coefficient of 0.997. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 8.50 × 10‐6 µg/mL and 2.83 × 10‐5 µg/mL, respectively. The method presented here produced good reproducibility with a relative standard deviation (RSD) of 2.70% (n = 7). The effects of common excipients and metal ions were studied for their interference effect. The method was validated statistically through recovery studies and successfully applied for the determination of sulpiride in pure form, pharmaceutical preparations and spiked human plasma samples. The percentage recoveries were found to range from 99.10 to 100.05% for pure form, 98.12 to 100.18% for pharmaceutical preparations and 97.9 to 101.4% for spiked human plasma. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid and sensitive flow injection chemiluminescence (FI–CL) method is described for the determination of 2‐methoxyestradiol (2ME) based on enhancement of the CL intensity from a potassium ferricyanide–calcein system in sodium hydroxide medium. The optimum conditions for the CL emission were investigated. Under optimized conditions, a linear calibration graph was obtained over the range 1.0 × 10‐8 to 1.0 × 10‐6 mol/L (r = 0.998) 2ME with a detection limit (3σ) of 5.4 × 10‐9 mol/L. The relative standard deviation (RSD) for 5.0 × 10‐7 mol/L 2ME was 1.7%. As a preliminary application, the proposed method was successfully applied to the determination of 2ME in injection solutions and serum samples. The possible CL mechanism was also proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号