首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 875 毫秒
1.
We have used tobacco mosaic virus (TMV) as a test specimen, in order to develop techniques for the analysis of high-resolution structural detail in electron micrographs of biological assemblies with helical symmetry. It has previously been shown that internal details of protein structure can be visualized by processing electron micrographs of unstained specimens of extended two-dimensional crystalline arrays. However, the techniques should in principle be applicable to other periodic specimens, such as assemblies with helical symmetry. We show here that data to spacings better than 10 A can be retrieved from electron images of frozen hydrated TMV. The three-dimensional computed map agrees well with that derived from X-ray diffraction and shows the two pairs of alpha-helices forming the core of the coat subunit, the C alpha-helix and the viral RNA. The results demonstrate that it is possible to determine detailed internal structure in helical particles.  相似文献   

2.
Electron images can be used to provide amplitudes and phases for the structural determination of biological specimens. Radiation damage limits the amount of structural information retrievable by computer processing. A 400-kV electron microscope was used to investigate radiation damage effects on frozen, hydrated actin bundles kept at -168 degrees C. The quality of phases within and among images in a damage series was evaluated quantitatively out to 16 A resolution. It was found that the phases of structure factors with good signal-to-noise ratio (IQ less than or equal to 4) can be reliably retrieved from images taken at a cumulative dose of at least 25 electrons/A2.  相似文献   

3.
Bacteriorhodopsin and ε 15 bacteriophage were used as biological test specimens to evaluate the potential structural resolution with images captured from a 4k × 4k charge-coupled device (CCD) camera in a 300-kV electron cryomicroscope. The phase residuals computed from the bacteriorhodopsin CCD images taken at 84,000× effective magnification averaged 15.7° out to 5.8-Å resolution relative to Henderson’s published values. Using a single-particle reconstruction technique, we obtained an 8.2-Å icosahedral structure of ε 15 bacteriophage with the CCD images collected at an effective magnification of 56,000×. These results demonstrate that it is feasible to retrieve biological structures to a resolution close to 2/3 of the Nyquist frequency from the CCD images recorded in a 300-kV electron cryomicroscope at a moderately high but practically acceptable microscope magnification.  相似文献   

4.
We report the development of a novel, multi-specimen imaging system for high-throughput transmission electron microscopy. Our cartridge-based loading system, called the "Gatling", permits the sequential examination of as many as 100 specimens in the microscope for room temperature electron microscopy using mechanisms for rapid and automated specimen exchange. The software for the operation of the Gatling and automated data acquisition has been implemented in an updated version of our in-house program AutoEM. In the current implementation of the system, the time required to deliver 95 specimens into the microscope and collect overview images from each is about 13 h. Regions of interest are identified from a low magnification atlas generation from each specimen and an unlimited number of higher magnifications images can be subsequently acquired from these regions using fully automated data acquisition procedures that can be controlled from a remote interface. We anticipate that the availability of the Gatling will greatly accelerate the speed of data acquisition for a variety of applications in biology, materials science, and nanotechnology that require rapid screening and image analysis of multiple specimens.  相似文献   

5.
A fast-freeze, cold-stage transmission electron microscopy technique which can incorporate in situ freeze-drying of the sample is described. Its use in elucidating structure in unstained and stained, hydrated and freeze-dried, aqueous vesicular dispersions of biological and chemical interest is demonstrated with vesicles of l-α-phosphatidylcholine (bovine phosphatidylcholine) and of the synthetic surfactant sodium 4-(1′-heptylnonyl)benzenesulfonate (SHBS). The contrast features observed in transmission electron microscope images of frozen, hydrated samples are identified and explained with the dynamical theory of electron diffraction. Radiolysis by the electron beam is shown to increase contrast in vesicle images and to change their structure and size. Micrographs illustrate the freeze-drying of a dispersion in the microscope; the process causes vesicles to shrink and collapse.  相似文献   

6.
Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.  相似文献   

7.
One limitation in electron cryo-microscopy (cryo-EM) is the inability to recover high-resolution signal from the image-recording media at the full-resolution limit of the transmission electron microscope. Direct electron detection using CMOS-based sensors for digitally recording images has the potential to alleviate this shortcoming. Here, we report a practical performance evaluation of a Direct Detection Device (DDD®) for biological cryo-EM at two different microscope voltages: 200 and 300 kV. Our DDD images of amorphous and graphitized carbon show strong per-pixel contrast with image resolution near the theoretical sampling limit of the data. Single-particle reconstructions of two frozen-hydrated bacteriophages, P22 and ε15, establish that the DDD is capable of recording usable signal for 3D reconstructions at about 4/5 of the Nyquist frequency, which is a vast improvement over the performance of conventional imaging media. We anticipate the unparalleled performance of this digital recording device will dramatically benefit cryo-EM for routine tomographic and single-particle structural determination of biological specimens.  相似文献   

8.
Our review concentrates on the progress made in high-resolution transmission electron microscopy (TEM) in the past decade. This includes significant improvements in sample preparation by quick-freezing aimed at preserving the specimen in a close-to-native state in the high vacuum of the microscope. Following advances in cold stage and TEM vacuum technology systems, the observation of native, frozen hydrated specimens has become a widely used approach. It fostered the development of computer guided, fully automated low-dose data acquisition systems allowing matched pairs of images and diffraction patterns to be recorded for electron crystallography, and the collection of entire tilt-series for electron tomography. To achieve optimal information transfer to atomic resolution, field emission electron guns combined with acceleration voltages of 200-300 kV are now routinely used. The outcome of these advances is illustrated by the atomic structure of mammalian aquaporin-O and by the pore-forming bacterial cytotoxin ClyA resolved to 12 A. Further, the Yersinia injectisome needle, a bacterial pseudopilus and the binding of phalloidin to muscle actin filaments were chosen to document the advantage of the high contrast offered by dedicated scanning transmission electron microscopy (STEM) and/or the STEM's ability to measure the mass of protein complexes and directly link this to their shape. Continued progress emerging from leading research laboratories and microscope manufacturers will eventually enable us to determine the proteome of a single cell by electron tomography, and to more routinely solve the atomic structure of membrane proteins by electron crystallography.  相似文献   

9.
Cryo-electron tomography of frozen hydrated cells has provided cell biologists with an indispensable tool for delineating three-dimensional arrangements of cellular ultrastructure. To avoid the damage induced by electron irradiation, images of frozen hydrated biological specimens are generally acquired under low-dose conditions, resulting in weakly contrasted images that are difficult to interpret, and in which ultrastructural details remain ambiguous. Zernike phase contrast transmission electron microscopy can improve contrast, and can also fix a fatal problem related to the inherent low contrast of conventional electron microscopy, namely, image modulation due to the unavoidable setting of deep defocus. In this study, we applied cryo-electron tomography enhanced with a Zernike phase plate, which avoids image modulation by allowing in-focus setting. The Zernike phase contrast cryo-electron tomography has a potential to suppress grainy background generation. Due to the smoother background in comparison with defocus phase contrast cryo-electron tomography, Zernike phase contrast cryo-electron tomography could yield higher visibility for particulate or filamentous ultrastructure inside the cells, and allowed us to clearly recognize membrane protein structures.  相似文献   

10.
A method is described for examining water dispersible biopolymers in the frozen, hydrated state by electron microscopy using the filamentous bacterial viruses Pf1 and fd as examples. The technique reveals liquid-crystalline textures that correlate well with polarizing microscopy of magnetically oriented specimens. At higher magnification the packing of the virus particle is revealed to a spatial resolution of better than 30 Å, thus linking directly with data from X-ray diffraction and optical microscopy. Electron diffraction confirms that the structure is preserved to high resolution (4 Å). The technique permits a detailed understanding of the processes involved in the orientation of these samples in a strong magnetic field and clarifies the long-range bi-axial properties of some fibres as seen by X-ray diffraction and optical microscopy.  相似文献   

11.
The electron microscope provides a powerful tool for investigating the structure of biological complexes such as viruses. A modern instrument is fully capable of atomic resolution on suitable non-biological specimens, but biological materials are difficult to preserve, owing to their fragility, and to image, owing to their radiation, sensitivity. The act of imaging the specimen severely damages it. Originally, samples were prepared by staining with a heavy metal salt, which provides a stable specimen but limits the amount of details that can be retrieved. Now particulate specimens, such as viruses, are prepared by rapid freezing of unstained material and observed in a frozen state with low doses of electrons. The resulting images require extensive computer processing to extract fully detailed three-dimensional information about the specimen. The whole process is referred to as single-particle electron cryomicroscopy. Using this approach, the structure of the human hepatitis B virus core was solved at the level of the protein fold. By comparing maps of RNA- and DNA-containing cores, it was possible to propose a model for the maturation and control of the envelopment of the virus during assembly. These examples show that cryomicroscopy offers great potential for understanding the structure and function of complex biological assemblies.  相似文献   

12.
2190 measurements of capillary basement membrane thickness were obtained from the images of magnified micrographs using a rear opaque projection screen. This method proved to be reproducible and reliable. The electron microscope magnification used, 2500x, permits sharp definition of structures in the resulting micrographs. Projection on the opaque rear screen magnified the image 16x, yielding a final magnification of 40,000x. This high final magnification of micrographs of good quality minimized the error in measurement. The use of a special dial caliper with pins attached allows an open field and decreases the subjective components of measurements. Moreover, this technique results in less stress for the persons performing the measurements.  相似文献   

13.
Single particle electron microscopy (EM), of both negative stained or frozen hydrated biological samples, has become a versatile tool in structural biology 1. In recent years, this method has achieved great success in studying structures of proteins and macromolecular complexes 2, 3. Compared with electron cryomicroscopy (cryoEM), in which frozen hydrated protein samples are embedded in a thin layer of vitreous ice 4, negative staining is a simpler sample preparation method in which protein samples are embedded in a thin layer of dried heavy metal salt to increase specimen contrast 5. The enhanced contrast of negative stain EM allows examination of relatively small biological samples. In addition to determining three-dimensional (3D) structure of purified proteins or protein complexes 6, this method can be used for much broader purposes. For example, negative stain EM can be easily used to visualize purified protein samples, obtaining information such as homogeneity/heterogeneity of the sample, formation of protein complexes or large assemblies, or simply to evaluate the quality of a protein preparation.In this video article, we present a complete protocol for using an EM to observe negatively stained protein sample, from preparing carbon coated grids for negative stain EM to acquiring images of negatively stained sample in an electron microscope operated at 120kV accelerating voltage. These protocols have been used in our laboratory routinely and can be easily followed by novice users.  相似文献   

14.
Understanding the hierarchical organizations of molecules and organelles within the interior of large eukaryotic cells is a challenge of fundamental interest in cell biology. Light microscopy is a powerful tool for observations of the dynamics of live cells, its resolution attainable is limited and insufficient. While electron microscopy can produce images with astonishing resolution and clarity of ultra-thin (< 1 μm thick) sections of biological specimens, many questions involve the three-dimensional organization of a cell or the interconnectivity of cells. X-ray microscopy offers superior imaging resolution compared to light microscopy, and unique capability of nondestructive three-dimensional imaging of hydrated unstained biological cells, complementary to existing light and electron microscopy.  相似文献   

15.
Summary Electron microscopy (EM) has greatly helped to elucidate our understanding of bacterial structure and function. However, several recent studies have cautioned investigators about artifacts that result from the use of conventional EM preparation procedures. To avoid these problems, the use of low temperature scanning electron microscopy (LTSEM) was evaluated for examining frozen, fully hydrated specimens. Spinach leaves (Spinacia oleracea L. cv. New Jersey), which were naturally infected or inoculated with bacteria, were used as the experimental material. 1 cm segments of the infected leaves were plunge frozen in liquid nitrogen, transferred to a cryochamber for sputter coating and then moved onto a cryostage in an SEM. After observation, some of the frozen, hydrated leaf segments were transferred onto agar medium to determine whether preparation for LTSEM was nondestructive to the bacteria. The other tissue segments were chemically fixed by freeze-substitution. The results indicated that after cryopreparation and observation in the LTSEM: (i) viable bacteria, which were recovered from the leaf sample, could be cultured on agar medium for subsequent study, and (ii) the frozen samples could be freeze substituted and embedded so that transmission electron microscopic (TEM) observations could be carried out on the same specimen. In conclusion, frozen, hydrated leaf tissue infected with bacteria can be observed using LTSEM and then can be either processed for TEM observation to obtain further structural details or recovered to culture the pathogenic bacteria for supplementary studies.Abbreviations EPS extracellular polysaccharide - EM electron microscopy - LTSEM low temperature scanning electron microscopy - SEM scanning electron microscopy - TEM transmission electron microscopy - TSA tryptic soy agar - TSB tryptic soy broth Dedicated to Professor Eldon H. Newcomb in recognition of his contributions to cell biology  相似文献   

16.
Observations of intact reconstituted and native collagen fibres were performed with the atomic force microscope. The results are compared between the two types of fibres and with those obtained previously with the electron microscope on freeze-etched or negative stained samples. Some of the findings presented here indicate that the specimens observed in air with the atomic force microscope were still in a hydrated state.  相似文献   

17.
We have previously reported the development of AutoEM, a software package for semi-automated acquisition of data from a transmission electron microscope. In continuing efforts to improve the speed of structure determination of macromolecular assemblies by electron microscopy, we report here on the performance of a new generation of 4 K CCD cameras for use in cryo electron microscopic applications. We demonstrate that at 120 kV, and at a nominal magnification of 67000 x, power spectra and signal-to-noise ratios for the new 4 K CCD camera are comparable to values obtained for film images scanned using a Zeiss scanner to resolutions as high as approximately 1/6.5A(-1). The specimen area imaged for each exposure on the 4 K CCD is about one-third of the area that can be recorded with a similar exposure on film. The CCD camera also serves the purpose of recording images at low magnification from the center of the hole to measure the thickness of vitrified ice in the hole. The performance of the camera is satisfactory under the low-dose conditions used in cryo electron microscopy, as demonstrated here by the determination of a three-dimensional map at 15 A for the catalytic core of the 1.8 MDa Bacillus stearothermophilus icosahedral pyruvate dehydrogenase complex, and its comparison with the previously reported atomic model for this complex obtained by X-ray crystallography.  相似文献   

18.
19.
The native structure of the calcium release channel (ryanodine receptor) from rabbit skeletal muscle has been analyzed in two dimensions from electron micrographs of frozen hydrated specimens. Within a resolution of 3.0 nm there is excellent agreement between the structure as seen in vitreous water and in negative stained specimens. Features seen in the three-dimensional reconstruction of the negatively stained channel can be identified in the projection of the unstained receptor.  相似文献   

20.
Capturing complete internal anatomies of plant organs and tissues within their relevant morphological context remains a key challenge in plant science. While plant growth and development are inherently multiscale, conventional light, fluorescence, and electron microscopy platforms are typically limited to imaging of plant microstructure from small flat samples that lack a direct spatial context to, and represent only a small portion of, the relevant plant macrostructures. We demonstrate technical advances with a lab-based X-ray microscope (XRM) that bridge the imaging gap by providing multiscale high-resolution three-dimensional (3D) volumes of intact plant samples from the cell to the whole plant level. Serial imaging of a single sample is shown to provide sub-micron 3D volumes co-registered with lower magnification scans for explicit contextual reference. High-quality 3D volume data from our enhanced methods facilitate sophisticated and effective computational segmentation. Advances in sample preparation make multimodal correlative imaging workflows possible, where a single resin-embedded plant sample is scanned via XRM to generate a 3D cell-level map, and then used to identify and zoom in on sub-cellular regions of interest for high-resolution scanning electron microscopy. In total, we present the methodologies for use of XRM in the multiscale and multimodal analysis of 3D plant features using numerous economically and scientifically important plant systems.

Lab-based X-ray microscopy allows high-resolution 3D imaging of intact plant samples over a wide range of sample types and sizes, filling the imaging gap between light and electron microscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号