首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Polymerase chain reaction (PCR) is a sensitive and rapid method for the diagnosis of canine Leishmania infection and can be performed on a variety of biological samples, including peripheral blood, lymph node, bone marrow and skin. Standard PCR requires electrophoretic analysis of the amplification products and is usually not suitable for quantification of the template DNA (unless competitor-based or other methods are developed), being of reduced usefulness when accurate monitoring of target DNA is required. Quantitative real-time PCR allows the continuous monitoring of the accumulation of PCR products during the amplification reaction. This allows the identification of the cycle of near-logarithmic PCR product generation (threshold cycle) and, by inference, the relative quantification of the template DNA present at the start of the reaction. Since the amplification product are monitored in "real-time" as they form cycle-by-cycle, no post-amplification handling is required. The absolute quantification is performed according either to an internal standard co-amplified with the sample DNA, or to an external standard curve obtained by parallel amplification of serial known concentrations of a reference DNA sequence. From the quantification of the template DNA, an estimation of the relative load of parasites in the different samples can be obtained. The advantages compared to standard and semi-quantitative PCR techniques are reduction of the assay's time and contamination risks, and improved sensitivity. As for standard PCR, the minimal components of the quantitative PCR reaction mixture are the DNA target of the amplification, an oligonucleotide primer pair flanking the target sequence, a suitable DNA polymerase, deoxynucleotides, buffer and salts. Different technologies have been set up for the monitoring of amplification products, generally based on the use of fluorescent probes. For instance, SYBR Green technology is a non-specific detection system based on a fluorescent dsDNA intercalator and it is applicable to all potential targets. TaqMan technology is more specific since performs the direct assessment of the amount of amplified DNA using a fluorescent probe specific for the target sequence flanked by the primer pair. This probe is an oligonucleotide labelled with a reporter dye (fluorescent) and a quencher (which absorbs the fluorescent signal generated by the reporter). The thermic protocol of amplification allows the binding of the fluorescent probe to the target sequence before the binding of the primers and the starting of the polymerization by Taq polymerase. During polymerization, 5'-3' exonuclease activity of Taq polymerase digests the probe and in this way the reporter dye is released from the probe and a fluorescent signal is detected. The intensity of the signal accumulates at the end of each cycle and is related to the amount of the amplification product. In recent years, quantitative PCR methods based either on SYBR Green or TaqMan technology have been set up for the quantification of Leishmania in mouse liver, mouse skin and human peripheral blood, targeting either single-copy chromosomal or multi-copy minicircle sequences with high sensitivity and reproducibility. In particular, real-time PCR seems to be a reliable, rapid and noninvasive method for the diagnosis and follow up of visceral leishmaniasis in humans. At present, the application of real-time PCR for research and clinical diagnosis of Leishmania infection in dogs is still foreseable. As for standard PCR, the high sensitivity of real-time PCR could allow the use of blood sampling that is less invasive and easily performed for monitoring the status of the dogs. The development of a real-time PCR assay for Leishmania infantum infection in dogs could support the standard and optimized serological and PCR methods currenly in use for the diagnosis and follow-up of canine leishmaniasis, and perhaps prediction of recurrences associated with tissue loads of residual pathogens after treatment. At this regard, a TaqMan Real Time PCR method developed for the quantification of Leishmania infantum minicircle DNA in peripheral blood of naturally infected dogs sampled before and at different time points after the beginning of a standard antileishmanial therapy will be illustrated.  相似文献   

2.
Kalendar R  Lee D  Schulman AH 《Genomics》2011,98(2):137-144
The polymerase chain reaction is fundamental to molecular biology and is the most important practical molecular technique for the research laboratory. We have developed and tested efficient tools for PCR primer and probe design, which also predict oligonucleotide properties based on experimental studies of PCR efficiency. The tools provide comprehensive facilities for designing primers for most PCR applications and their combinations, including standard, multiplex, long-distance, inverse, real-time, unique, group-specific, bisulphite modification assays, Overlap-Extension PCR Multi-Fragment Assembly, as well as a programme to design oligonucleotide sets for long sequence assembly by ligase chain reaction. The in silico PCR primer or probe search includes comprehensive analyses of individual primers and primer pairs. It calculates the melting temperature for standard and degenerate oligonucleotides including LNA and other modifications, provides analyses for a set of primers with prediction of oligonucleotide properties, dimer and G-quadruplex detection, linguistic complexity, and provides a dilution and resuspension calculator.  相似文献   

3.
粪便中肠球菌SYBR GreenI荧光定量PCR检测方法的建立   总被引:2,自引:0,他引:2  
目的利用SYBR GreenI荧光定量PCR方法,建立肠球菌实时荧光PCR检测方法,并初步应用于粪便中肠球菌的检测。方法根据GenBank发表的肠球菌23S rRNA基因序列的保守区域设计合成特异性的引物;利用构建的质粒标准品绘制两种标准曲线,构建基因拷贝数、细菌数为分析指标的定量分析模型并初步应用于粪便标本的检测分析。结果所建立的SYBR GreenI荧光定量PCR方法检测灵敏度可达7个拷贝数/reaction。粪便样本根据实时荧光定量PCR方法所得的理论数值与培养菌值之间差异无显著性(P>0.05)。非炎性腹泻标本中菌数与健康成人标本中菌数差异无显著性(P>0.05)。灵敏度曲线所得的数值大于菌数标准曲线,可能由于DNA提取过程中存在部分的损失。检测粪便标本结果显示SYBR GreenI荧光定量PCR方法较平板计数法敏感、快捷、简便。结论本研究建立了一种灵敏、特异、简便易行的肠球菌定量检测方法。  相似文献   

4.
Here we present MethylQuant, a novel method that allows accurate quantification of the methylation level of a specific cytosine within a complex genome. This method relies on the well-established treatment of genomic DNA with sodium bisulfite, which converts cytosine into uracil without modifying 5-methyl cytosine. The region of interest is then PCR-amplified and quantification of the methylation status of a specific cytosine is performed by methylation-specific real-time PCR with SYBR Green I using one of the primers whose 3′ end discriminates between the methylation states of this cytosine. The presence of a locked nucleic acid at the 3′ end of the discriminative primer provides the specificity necessary for accurate and sensitive quantification, even when one of the methylation states is present at a level as low as 1% of the overall population. We demonstrate that accurate quantification of the methylation status of specific cytosines can be achieved in biological samples. The method is high-throughput, cost-effective, relatively simple and does not require any specific equipment other than a real-time PCR instrument.  相似文献   

5.
6.
We introduce quantitative polymerase chain reaction (qPCR) primers and multiplex end-point PCR primers modified by the addition of a single ortho-Twisted Intercalating Nucleic Acid (o-TINA) molecule at the 5'-end. In qPCR, the 5'-o-TINA modified primers allow for a qPCR efficiency of 100% at significantly stressed reaction conditions, increasing the robustness of qPCR assays compared to unmodified primers. In samples spiked with genomic DNA, 5'-o-TINA modified primers improve the robustness by increased sensitivity and specificity compared to unmodified DNA primers. In unspiked samples, replacement of unmodified DNA primers with 5'-o-TINA modified primers permits an increased qPCR stringency. Compared to unmodified DNA primers, this allows for a qPCR efficiency of 100% at lowered primer concentrations and at increased annealing temperatures with unaltered cross-reactivity for primers with single nucleobase mismatches. In a previously published octaplex end-point PCR targeting diarrheagenic Escherichia coli, application of 5'-o-TINA modified primers allows for a further reduction (>45% or approximately one hour) in overall PCR program length, while sustaining the amplification and analytical sensitivity for all targets in crude bacterial lysates. For all crude bacterial lysates, 5'-o-TINA modified primers permit a substantial increase in PCR stringency in terms of lower primer concentrations and higher annealing temperatures for all eight targets. Additionally, crude bacterial lysates spiked with human genomic DNA show lesser formation of non-target amplicons implying increased robustness. Thus, 5'-o-TINA modified primers are advantageous in PCR assays, where one or more primer pairs are required to perform at stressed reaction conditions.  相似文献   

7.
The polymerase chain reaction (PCR) is most effectively performed using a thermostable DNA polymerase such as that isolated from Thermus aquaticus. Since temperature and oligonucleotide length are known to control the specificity of oligonucleotide hybridization, we have investigated the effect of oligonucleotide length, base composition, and the annealing temperature on the specificity and efficiency of amplification by the PCR. Generally, the specificity of PCR is controlled by the length of the oligonucleotide and/or the temperature of annealing of the primer to the template. An empirical relationship between oligonucleotide length and ability to support amplification was determined. This relationship allows for the design of specific oligonucleotide primers. A model is proposed which helps explain the observed dependence of PCR on annealing temperature and length of the primer.  相似文献   

8.
The quantification of the biological diversity in environmental samples using high‐throughput DNA sequencing is hindered by the PCR bias caused by variable primer–template mismatches of the individual species. In some dietary studies, there is the added problem that samples are enriched with predator DNA, so often a predator‐specific blocking oligonucleotide is used to alleviate the problem. However, specific blocking oligonucleotides could coblock nontarget species to some degree. Here, we accurately estimate the extent of the PCR biases induced by universal and blocking primers on a mock community prepared with DNA of twelve species of terrestrial arthropods. We also compare universal and blocking primer biases with those induced by variable annealing temperature and number of PCR cycles. The results show that reads of all species were recovered after PCR enrichment at our control conditions (no blocking oligonucleotide, 45 °C annealing temperature and 40 cycles) and high‐throughput sequencing. They also show that the four factors considered biased the final proportions of the species to some degree. Among these factors, the number of primer–template mismatches of each species had a disproportionate effect (up to five orders of magnitude) on the amplification efficiency. In particular, the number of primer–template mismatches explained most of the variation (~3/4) in the amplification efficiency of the species. The effect of blocking oligonucleotide concentration on nontarget species relative abundance was also significant, but less important (below one order of magnitude). Considering the results reported here, the quantitative potential of the technique is limited, and only qualitative results (the species list) are reliable, at least when targeting the barcoding COI region.  相似文献   

9.
10.
In the initial report, introducing a single phosphorothioate modification at the very 3' terminus of the oligodeoxynucleotide primer has been shown to effectively protect the oligodeoxynucleotide degradation due to the 3' exonuclease activity. In this study, we reported a novel finding that phosphorothioate modification at the 3' end of primers could not only effectively prevent the primer from degradation, but could also mediate an off-switch extension by Pfu polymerase when primers also carry single or multiple mismatched bases located in the first eight bases of the 3' terminus. This suggests that the combination of 3' phosphorothioate-modified primers with exo+ polymerases such as Pfu constituted an on/off switch, which allows perfectly matched primers to be extended but not mismatched primers. Furthermore, we found that polymerases with different fidelities showed different efficiencies in turning off mismatched-primer mediated extension. So we described here a SYBR green-based real-time quantitative PCR assay for the detection of abundance level of gene expression that did not require fluorescently labeled gene-specific probes or complicated primer combinations. The emergence of real-time quantitative RT-PCR technology is thus suited for a diverse application with a need for high-throughput methods to detect and quantify different gene expressions by way of simplicity, versatility, and accuracy, and thus could complement global microarray-based expression profiling strategies.  相似文献   

11.
We report the development of a new real-time polymerase chain reaction (PCR) detection system that uses oligonucleotide "tagged" PCR primers, a fluorophore-labeled "universal" detection oligonucleotides, and a complementary quenching oligonucleotide. The fluorescence signal decreases as PCR product accumulates due to the increase in detection/quencher hybrid formation as the tagged primer is consumed. We use plasmids containing the influenza A matrix gene and the porA and ctrA genes of Neisseria meningitidis as targets for developing the system. Cycle threshold (Ct) values were generated, and the sensitivity of the new system (dubbed "PrimRglo") compared favorably with the commonly used SYBR green and Taqman detection systems and, unlike the latter system, does not require the design of a new dual-labeled detection oligonucleotide for each new target sequence.  相似文献   

12.
In this work we have demonstrated two independent real-time PCR methods for detection single nucleotide polymorphism (SNP) of genes csn and acyl-CoA: diacylglycerol acyltransferase 1 (dgat) in cattle. We have analyzed 296 samples of milk production cattle of Ukrainian breeding. The genotype frequencies were AA--0.58, AB--0.34, BB--0.08 for csn gene and for dgat gene--AA--0.7, AK--0.26, KK--0.04. High efficiency of so called "anti-primer" method was shown. Duration of anti-primer PCR reaction was about 2-2.5 hours only and provided full investigation of unknown gene allele.  相似文献   

13.
Real-time RT-PCR has been used widely, both in fundamental research and in clinical diagnostics, for instance for quantification of RNA levels in human tissues and tissue biopsies. In the present study we provide a strategy to validate primers/probes for real-time RT-PCR quantification of baboon samples. The method is based on the TaqMan system and uses primers/probes that have been designed and validated for human real-time RT-PCR. A prerequisite for the accuracy of this strategy is a similar amplification efficiency between human and baboon PCR reactions. We propose two different methods, i.e. by calculating PCR efficiencies from the slope of a dilution curve or by using the linear regression method, to compare the amplification efficiency between human and baboon samples. In conclusion, by performing a simple validation experiment, real-time PCR assays based on human sequences, which are easily available, can be applied for analysis of baboon samples.  相似文献   

14.
It is clinically important to be able to detect influenza A/H1N1 virus using a fast, portable, and accurate system that has high specificity and sensitivity. To achieve this goal, it is necessary to develop a highly specific primer set that recognizes only influenza A viral genes and a rapid real-time PCR system that can detect even a single copy of the viral gene. In this study, we developed and validated a novel fluidic chip-type real-time PCR (LabChip real-time PCR) system that is sensitive and specific for the detection of influenza A/H1N1, including the pandemic influenza strain A/H1N1 of 2009. This LabChip real-time PCR system has several remarkable features: (1) It allows rapid quantitative analysis, requiring only 15 min to perform 30 cycles of real-time PCR. (2) It is portable, with a weight of only 5.5 kg. (3) The reaction cost is low, since it uses disposable plastic chips. (4) Its high efficiency is equivalent to that of commercially available tube-type real-time PCR systems. The developed disposable LabChip is an economic, heat-transferable, light-transparent, and easy-to-fabricate polymeric chip compared to conventional silicon- or glass-based labchip. In addition, our LabChip has large surface-to-volume ratios in micro channels that are required for overcoming time consumed for temperature control during real-time PCR. The efficiency of the LabChip real-time PCR system was confirmed using novel primer sets specifically targeted to the hemagglutinin (HA) gene of influenza A/H1N1 and clinical specimens. Eighty-five human clinical swab samples were tested using the LabChip real-time PCR. The results demonstrated 100% sensitivity and specificity, showing 72 positive and 13 negative cases. These results were identical to those from a tube-type real-time PCR system. This indicates that the novel LabChip real-time PCR may be an ultra-fast, quantitative, point-of-care-potential diagnostic tool for influenza A/H1N1 with a high sensitivity and specificity.  相似文献   

15.
The application of a real-time quantitative PCR method (5' nuclease assay), based on the use of a probe labeled at its 5' end with a stable, fluorescent lanthanide chelate, for the quantification of human fecal bifidobacteria was evaluated. The specificities of the primers and the primer-probe combination were evaluated by conventional PCR and real-time PCR, respectively. The results obtained by real-time PCR were compared with those obtained by fluorescent in situ hybridization, the current gold standard for intestinal microbiota quantification. In general, a good correlation between the two methods was observed. In order to determine the detection limit and the accuracy of the real-time PCR procedure, germfree rat feces were spiked with known amounts of bifidobacteria and analyzed by both methods. The detection limit of the method used in this study was found to be about 5 x 10(4) cells per g of feces. Both methods, real-time PCR and fluorescent in situ hybridization, led to an accurate quantification of the spiked samples with high levels of bifidobacteria, but real-time PCR was more accurate for samples with low levels. We conclude that the real-time PCR procedure described here is a specific, accurate, rapid, and easy method for the quantification of bifidobacteria in feces.  相似文献   

16.
Most human messenger RNAs (mRNAs) are alternatively spliced and many exhibit disease-specific splicing patterns. However, the contribution of most splicing events to the development and maintenance of human diseases remains unclear. As the contribution of alternative splicing events to diagnosis and prognosis is becoming increasingly recognized, it becomes important to develop precise methods to quantify the abundance of these isoforms in clinical samples. Here we present a pipeline for real-time PCR annotation of splicing events (RASE) that allows accurate identification of a large number of splicing isoforms in human tissues. The RASE automatically designed specific primer pairs for 81% of all alternative splicing events in the NCBI build 36 database. Experimentally, the majority of the RASE designed primers resulted in isoform-specific amplification suitable for quantification in human cell lines or in formalin-fixed, paraffin-embedded (FFPE) RNA extract. Using this pipeline it is now possible to rapidly identify splicing isoform signatures in different types of human tissues or to validate complete sets of data generated by microarray expression profiling and deep sequencing techniques.  相似文献   

17.
For quantitative PCR assay of Salmonella enterica serovar Typhimurium in food samples, a real-time PCR method was developed, based on DNA genome equivalent. Specific primers and probe designed based on the STM4497 gene of S. Typhimurium LT2 showed the specificity to S. Typhimurium. Threshold cycle (Ct) values of real-time PCR were obtained from a quantitative standard curve with genomic DNA of Salmonella Typhimurium. In addition, the recovery of S. Typhimurium inoculated artificially to chicken samples with 4.5x105 to 4.5x100 CFU/ml was evaluated by using real-time PCR and plate-count methods. Result showed that the number of cells calculated from the real-time PCR method had good correlation with that of the plate-count method. This real-time PCR method could be applicable to the detection and quantification of S. Typhimurium in food samples.  相似文献   

18.
19.
We have developed a quantitative PCR assay (LightCycler* using the pair of primers JW58 and JW59 for the detection of the 35-fold repeated B gene of oxoplasma gondii. This real-time PCR, using fluorescence resonance energy transfert (FRET) hybridization probes, allows the quantification of . gondii with several technical requirements not previously described: i) an internal amplification control (co-amplified in a single tube with the same primers), ii) Uracil-N-Glycosylase and iii) a standard curve corresponding to a serial dilution from a calibrated suspension of T. gondii ranging from 40 to 4.106( )parasites in one ml of amniotic fluid (1 to 105( ) . gondii/PCR). In artificial samples, one parasite could be detected if at least three reactions were performed.  相似文献   

20.
Multiplex quantitative PCR based on novel design of fluorescent primers is described. Fluorogenic primers are labeled with a single fluorophore on a base close to the 3′ end with no quencher required. A tail of 5–7 nt is added to the 5′ end of the primer to form a blunt-end hairpin when the primer is not incorporated into a PCR product. This design provides a low initial fluorescence of the primers that increases up to 8-fold upon formation of the PCR product. The hairpin oligonucleotides (ΔG from 1.6 to –5.8 kcal/mol) may be as efficient as linear primers and provide additional specificity to the PCR by preventing primer-dimers and mispriming. Multiple fluorogenic primers were designed by specialized software and used for real-time quantitation of c-myc and IL-4 cDNAs in the presence of reference genes such as β-actin, GAPDH and 18S rRNA. Targets of 10107 copies were detected with precision in PCR using FAM-labeled primers for variable genes and JOE-labeled primers for the reference genes. This method was also used to detect single nucleotide polymorphism of the human retinal degeneration gene by allele-specific PCR with end-point detection using a fluorescent plate reader or a UV-transilluminator. We conclude that fluorogenic mono-labeled primers are an efficient and cost-effective alternative to FRET-labeled oligonucleotides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号