首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An area located in the Southern Urals was contaminated in 1949–1956 as a result of radioactive waste releases into the Techa river by the Mayak Production Association. The external dose reconstruction of the Techa river dosimetry system (TRDS-2000) for the exposed population is based on an assessment of dose rates in air (DRA) obtained by modeling transport and deposition of radionuclides along the river for the time before 1952 and by gamma dose rate measurements since 1952. The aim of this paper is to contribute to a verification of the TRDS-2000 external dose assessment. Absorbed doses in bricks from a 130-year-old building in the heavily exposed Metlino settlement were measured by a luminescence technique. By the autumn of 1956 the population of Metlino had been evacuated, and then a water reservoir was created at the village location, which led to a change in the radioactive source geometry. Radiation transport calculations for assumed environmental sources before and since 1957 were performed with the MCNP Monte Carlo code. In combination with TRDS-2000 estimates for annual dose rates in air at the shore of the Techa river for the period 1949–1956 and contemporary dose rate in air measurements, absorbed doses in bricks were calculated. These calculations were performed deterministically with best estimates of the modeling parameters and stochastically by propagating uncertainty distributions through the calculation scheme. Assessed doses in bricks were found to be consistent with measured values within the uncertainty bounds, while their best estimates were approximately 15% lower than the luminescence measurements.An erratum to this article can be found at  相似文献   

2.
Absorbed doses were determined by thermoluminescence (TL) measurements for bricks from a height of 6 m from the south-western wall of the former mill in Metlino that faced the Techa river. Measurements of the internal beta-radiation and alpha-radiation in the brick samples and of radionuclide activities in soil samples from the Techa river valley were performed. The absorbed dose in bricks due to the natural radiation was derived and subtracted from the total dose in order to obtain the absorbed dose in the bricks caused by anthropogenic sources. The results were combined with results from two previous studies. The absorbed dose in the bricks due to the radiation field after relocation of the Metlino population in 1956 was derived from dose rates in air measured in front of the sampling locations in 1996/1997. Based on these dose rates the dose to bricks was calculated by means of conversion factors from the literature. The absorbed dose accumulated in the bricks in the period 1949–1956 was nearly 80% of the total dose that had been determined by TL measurements. Previously derived conversion factors were applied to obtain an estimate of the gamma dose in air at the former shore of the Techa river. An uncertainty and sensitivity analysis was performed with the program package Crystal Ball. Care was taken to treat statistical and systematic uncertainties separately and to take parameter correlations into account. The resulting distribution for the gamma dose accumulated in the period 1949–1956 at the Techa river shore has a median value of 32 Gy with a 95% confidence interval of 21–45 Gy. This study confirms the corresponding value of 26.6 Gy that is used in the Techa River Dosimetry System (TRDS) 2000.  相似文献   

3.
This paper presents the results of a feasibility cytogenetic study using the fluorescence in situ hybridization (FISH) translocation assay for residents of villages located on the Techa River (Southern Urals, Russia) contaminated with liquid radioactive wastes from the Mayak plutonium facility in 1949-1956. The study was conducted with two groups of donors that differed in their main pathways of exposure. The first group comprised 18 residents of the middle Techa region who were exposed predominantly from ingestion of radionuclides (mostly (89,90)Sr) via the river water and local foodstuffs. The second group included 20 residents of Metlino, the closest village to the site of releases, who were exposed to external γ radiation from the contaminated river bank and exposed internally from dietary intake of radionuclides. A significant linear dependence between the radiation-induced translocation frequency and individual red bone marrow dose from incorporated (89,90)Sr, calculated with the Techa River Dosimetry System (TRDS), was found in the first group of donors. This allowed us to take the contribution of (89,90)Sr to the total radiation-induced translocation frequency into account for the second group of donors and to analyze translocations resulting from external γ-ray exposure. Individual doses from external exposure derived from the corrected translocation frequency for the second group of donors (Metlino residents), using a linear dose-response coefficient of 0.015 translocation/cell/Gy recommended by Edwards et al. in 2005, were shown to vary up to 2.1 Gy, with an average value of 0.48 Gy, which was in agreement with TRDS-based external dose estimates for Metlino residents.  相似文献   

4.
This paper presents the results of an effort to evaluate anthropogenic doses in bricks from old buildings located on the banks of the Techa River. The river area was contaminated in 1949–1956 as a result of radioactive waste releases by the Mayak plutonium facility (Southern Urals, Russia). Absorbed doses were determined by luminescence measurements of quartz extracted from the near-surface layers of bricks sampled in 1991–1997 from three remained buildings (a mill, a granary and a church). These buildings are located in the former residence area of Metlino, which was the settlement located closest to the release site (residents of Metlino were relocated from the contaminated river in 1956). The measured anthropogenic dose in the three buildings was found to be comparable: minimum values were equal to 0.5–0.9 Gy and maximum values amounted to about 3–4 Gy. Unfortunately, the geometry of gamma-exposure of the brick samples changed significantly in 1956 as a result of creation of an artificial reservoir downstream of the Metlinsky pond. Since luminescence data provide absorbed dose in the investigated samples accumulated over the whole period of irradiation, for interpretation of the data obtained it is important to know the exposure geometry for the period of maximal exposure, which was in the early 1950s. In 2005, archival data describing configuration of contaminated water streams and shorelines (which were the main sources of gamma-irradiation) were published. Comparison of these data with the results of the luminescence study presented here showed that the bricks with the highest thermoluminescence (TL)-based doses faced contaminated shores and were located close to them. In contrast, the bricks with lower values of measured dose were opposite to contaminated shores and/or being shielded. This demonstrates that the luminescence method allowed reconstruction of the anthropogenic dose distribution in the former settlement center. The obtained results suggest new options for further luminescence studies in Metlino aimed at the reconstruction of the external exposures of the affected population.  相似文献   

5.
During 1949–1956, about 76 × 106 m3 of radioactive liquid waste containing a total activity of 1017 Bq was discharged into the Techa River by the first Russian industrial nuclear facility Mayak. As a consequence, the population living in the river valley received considerable internal and external radiation doses. The results of a first application of electron paramagnetic resonance (EPR) of tooth enamel for a retrospective individual dose evaluation of the residents of the Techa riverside are presented. Three main contributions to the dose absorbed in tooth enamel have been considered: external exposure mainly from the Techa River sediments, internal exposure mainly due to 90Sr; and background radiation including all other sources of exposure except the Techa River. The teeth of 86 inhabitants of the town Kamensk-Uralskii were analysed to determine the age-dependent contribution of the background radiation to the enamel dose. For 22 residents of the middle and lower Techa riverside, measurements of the 90Sr whole-body content and EPR measurements of the absorbed dose in enamel were used to establish a correlation between these two quantities. Finally, absorbed doses in the enamel of five residents of the upper Techa riverside were determined by the EPR method. Contributions of the background radiation and the internal 90Sr contamination were subtracted to determine the external exposure of the residents.  相似文献   

6.
In 1951 and 1952 specialists from the Mayak production association investigated the radiological situation in the area of the Metlinski reservoir that was located 5-7 km from the site of liquid radioactive waste (LRW) discharge. Based on their measurements of both the specific radioactivity in the water and the dose-rate above the water surface, the gamma-field above the water surface in 1951 was demonstrated to be mainly due to (95)Zr+(95)Nb. The dose-rate at the shore of the reservoir was calculated for the period 1949-1951. In November and December 1951, the gamma-field at the shore was mainly due to (140)Ba+(140)La. For the period 1949-1951, the external exposure of the Metlino population due to the decay of these radionuclides was about 200 R (2 Sv), most of the dose having been produced in 1951. The contribution of (137)Cs to external doses did at that time probably not exceed a fraction of several percent. This finding is in contradiction to the assumptions made in the most recent TRDS-2000 system that was developed to reconstruct the doses to the residents of the Techa river. The results presented here demonstrate that the reconstruction of external doses received by the Metlino population as well as by the Techa river residents can be improved for the most critical period between 1949 and 1954.  相似文献   

7.
In the period from 1949 to 1956, liquid radioactive waste was routinely and accidentally discharged by the Mayak Production Association, Southern Urals, Russia, into the Techa river. Based on a novel approach, the contamination of the Techa river water, the bottom sediments and the adjacent flood plains was modelled, and internal and external doses were estimated for two villages located downstream of the site of liquid radioactive waste release. Altogether, 11 radionuclides that occurred in the liquid radioactive waste were included in the calculations. The results suggest significantly higher doses than previously assumed, with the major contribution in the year 1951. Radionuclides with half-lives of less than 1 year, such as 89Sr, 131I, 95Zr+95Nb, 103Ru+103mRh, 140Ba+140La, and 144Ce+144Pr, represent the major sources and, in contrast, long-lived radionuclides, such as 90Sr and 137Cs that have so far been assumed to be most important, did not dominate the doses. For adults from the village Metlino, located 7 km downstream of the site of liquid radioactive waste discharge, the committed effective doses due to intake of radionuclides were calculated to be about 2.3 Sv, while the external doses were between about 1.2 Sv and 6.9 Sv. On the other hand, for adults from Muslyumovo, located 75 km downstream, the commited effective doses due to intake of radionuclides were calculated to be about 0.5 Sv, while the external doses were between 0.5 Sv and 2.0 Sv. The values for the skin doses to the Metlino and Muslyumovo populations were about 7.1 Sv and 1.3 Sv, respectively. It is concluded that the current dose estimates for the residents of the Techa river need, therefore, reevaluation.  相似文献   

8.
PurposeTo determine the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams.MethodsAn AGMS-DM+ semiconductor detector was calibrated in terms of air kerma measured with an ionization chamber. Air kerma was measured for 20 x-ray beams with tube voltages of 50–140 kVp and a half-value layer (HVL) of 2.2–9.7 mm Al for given quality index (QI) values of 0.4, 0.5, and 0.6, and converted to the surface dose. Finally, the air kerma and HVL measured by the AGMS-DM+ detector were expressed as a ratio of the surface dose for 10 × 10 and 20 × 20 cm2 fields. The ratio of both was represented as a function of HVL for the given QI values and verified by comparing it with that calculated using the Monte Carlo method.ResultsThe air kerma calibration factor, CF, for the AGMS-DM+ detector ranged from 0.986 to 1.016 (0.9% in k = 1). The CF values were almost independent of the x-ray fluence spectra for the given QI values. The ratio of the surface dose to the air kerma determined by the PTW 30,013 chamber and the AGMS-DM+ detector was less than 1.8% for the values calculated using the Monte Carlo method, and showed a good correlation with the HVL for the given QI values.ConclusionIt is possible to determine the surface dose of a water phantom from the air kerma and HVL measured by a semiconductor detector for given QI values.  相似文献   

9.
PurposeTo estimate the surface dose in diagnostic radiology in real time based on the relationship between the incident air kerma and the surface dose.MethodsThe air kerma for 20 X-ray beams with tube voltages of 50–140 kV and a half-value layer (HVL) of 2.27–9.65 mm Al was measured using an ionization chamber. The beam quality was classified based on the quality indexes (QIs) of 0.4, 0.5, and 0.6, which are defined as the ratio of the effective energy to the maximum energy corresponding to the tube potential. The surface dose for 20 X-ray beams was evaluated based on the measured air kerma, backscatter factor, and ratio of the mass–energy absorption coefficients of water to air, which were calculated using the Monte Carlo method. Finally, the relationship between the air kerma and the surface dose was investigated for X-ray beams with the specific QI values.ResultsThe surface dose at a water phantom was represented by a linear approximation of R2 > 0.98, with the air kerma, regardless of the X-ray beam quality. The surface dose estimated based on a linear approximation with the air kerma indicated an agreement within 8% with that evaluated by the chamber measurements at HVL > 3.4 mm Al.ConclusionIt is possible to estimate the surface dose in real time using the linear relationship between the incident air kerma and the surface dose regardless of the X-ray beam quality by accepting ±10% uncertainty in the surface dose estimation.  相似文献   

10.
Organ or tissue equivalent dose, the most important quantity in radiation protection, cannot be measured directly. Therefore it became common practice to calculate the quantity of interest with Monte Carlo methods applied to so-called human phantoms, which are virtual representations of the human body. The Monte Carlo computer code determines conversion coefficients, which are ratios between organ or tissue equivalent dose and measurable quantities. Conversion coefficients have been published by the ICRP (Report No. 74) for various types of radiation, energies and fields, which have been calculated, among others, with the mathematical phantoms ADAM and EVA. Since then progress of image processing, and of clock speed and memory capacity of computers made it possible to create so-called voxel phantoms, which are a far more realistic representation of the human body. Voxel (Volume pixel) phantoms are built from segmented CT and/or MRI images of real persons. A complete set of such images can be joined to a 3-dimensional representation of the human body, which can be linked to a Monte Carlo code allowing for particle transport calculations. A modified version of the VOX_TISS8 human voxel phantom (Yale University) has been connected to the EGS4 Monte Carlo code. The paper explains the modifications, which have been made, the method of coupling the voxel phantom with the code, and presents results as conversion coefficients between organ equivalent dose and kerma in air for external photon radiation. A comparison of the results with published data shows good agreement.  相似文献   

11.
The major goal of this study was to identify and quantitatively describe the association between the characteristics of chronic (low-dose rate) exposure to (low LET) ionizing radiation and cellularity of peripheral blood cell lines. About 3,200 hemograms (i.e., spectra of blood counts) obtained over the years of maximal exposure to ionizing radiation (1950–1956) for inhabitants of the Techa River were used in analyses. The mean cumulative red bone marrow dose (with standard errors), calculated using Techa River Dosimetry System-2000, was 333.6 ± 4.6 mGy (SD = 259.9 mGy, max = 1151 mGy) to the year 1956. The statistical approach included both empirical methods for estimating frequencies of cytopenic states of the investigated blood cell lines (e.g. neutrophile, platelets, erythrocyte, etc.), and regression methods, including generalized linear models and logistic regressions which allowed taking into account confounding factors (e.g., attained age, age at maximal exposure, presence of concomitant diseases, and demographic characteristics). The results of the analyses demonstrated hematopoiesis inhibition manifested by a decrease in peripheral blood cellularity and an increase in the frequency of cytopenia in all blood cell lines (leukocytes, including lymphocytes, monocytes, neutrophiles, as well as platelets and erythrocytes). The intensity of hematopoiesis inhibition in the period of maximal exposures is determined by the combined influence of the dose rate and cumulative dose. The contribution of specific confounding factors was quantified and shown to be much less important than dose characteristics. The best predictor among dose characteristics was identified for each blood cell line. A 2-fold increase in dose rate is assumed to be a characteristic of radiosensitivity and a quantitative characteristic of the effect.  相似文献   

12.

Background

Task group number 40 (TG-40) of the American Association of Physicists in Medicine (AAPM) has recommended calibration of any brachytherapy source before its clinical use. GZP6 afterloading brachytherapy unit is a 60Co high dose rate (HDR) system recently being used in some of the Iranian radiotherapy centers.

Aim

In this study air kerma strength (AKS) of 60Co source number three of this unit was estimated by Monte Carlo simulation and in air measurements.

Materials and methods

Simulation was performed by employing the MCNP-4C Monte Carlo code. Self-absorption of the source core and its capsule were taken into account when calculating air kerma strength. In-air measurements were performed according to the multiple distance method; where a specially designed jig and a 0.6 cm3 Farmer type ionization chamber were used for the measurements. Monte Carlo simulation, in air measurement and GZP6 treatment planning results were compared for primary air kerma strength (as for November 8th 2005).

Results

Monte Carlo calculated and in air measured air kerma strength were respectively equal to 17240.01 μGym2 h−1 and 16991.83 μGym2 h−1. The value provided by the GZP6 treatment planning system (TPS) was “15355 μGym2 h−1”.

Conclusion

The calculated and measured AKS values are in good agreement. Calculated-TPS and measured-TPS AKS values are also in agreement within the uncertainties related to our calculation, measurements and those certified by the GZP6 manufacturer. Considering the uncertainties, the TPS value for AKS is validated by our calculations and measurements, however, it is incorporated with a large uncertainty.  相似文献   

13.
Dosimetry calculations characterizing the spatial variation of the energy deposited by the slowing and stopping of energetic electrons are reported and compared with experimental measurements from an electron microbeam facility. The computations involve event-by-event, detailed-histories Monte Carlo simulations of low-energy electrons interacting in water vapor. Simulations of electron tracks with starting energies from 30 to 80 keV are used to determine energy deposition distributions in thin cylindrical rings as a function of penetration and radial distance from a beam source. Experimental measurements of the spatial distribution of an electron microbeam in air show general agreement with the density-scaled simulation results for water vapor at these energies, yielding increased confidence in the predictions of Monte Carlo track-structure simulations for applications of the microbeam as a single-cell irradiator.  相似文献   

14.
PurposePatient dose estimation in X-ray computed tomography (CT) is generally performed by Monte Carlo simulation of photon interactions within anthropomorphic or cylindrical phantoms. An accurate Monte Carlo simulation requires an understanding of the effects of the bow-tie filter equipped in a CT scanner, i.e. the change of X-ray energy and air kerma along the fan-beam arc of the CT scanner. To measure the effective energy and air kerma distributions, we devised a pin-photodiode array utilizing eight channels of X-ray sensors arranged at regular intervals along the fan-beam arc of the CT scanner.MethodsEach X-ray sensor consisted of two plate type of pin silicon photodiodes in tandem – front and rear photodiodes – and of a lead collimator, which only allowed X-rays to impinge vertically to the silicon surface of the photodiodes. The effective energy of the X-rays was calculated from the ratio of the output voltages of the photodiodes and the dose was calculated from the output voltage of the front photodiode using the energy and dose calibration curves respectively.ResultsThe pin-photodiode array allowed the calculation of X-ray effective energies and relative doses, at eight points simultaneously along the fan-beam arc of a CT scanner during a single rotation of the scanner.ConclusionsThe fan-beam energy and air kerma distributions of CT scanners can be effectively measured using this pin-photodiode array.  相似文献   

15.
The Techa River (Southern Urals, Russia) was contaminated as a result of radioactive releases by the Mayak plutonium production facility during 1949-1956. The persons born after the onset of the contamination have been identified as the "Techa River Offspring Cohort" (TROC). The TROC has the potential to provide direct data on health effects in progeny that resulted from exposure of a general parent population to chronic radiation. The purpose of the present investigation is the estimation of (90)Sr intake from breast milk and river water in the period from birth to 6 months of life, necessary for an infant dose calculation. The investigation is based on all available data concerning radioactive contamination due to global fallouts and Mayak releases in the Southern Urals where extensive radiometric and radiochemical investigations of human tissues and environmental samples were conducted during the second half of the twentieth century. The strontium transfer factor from mother's daily diet to breast milk was estimated as 0.05 (0.01-0.13) d L(-1). Based on this transfer factor and data on (90)Sr water contamination, the average total (90)Sr intake for an infant born in the middle Techa River region was found to be equal to 60-80 kBq in 1950-1951. For the same period, calculations of (90)Sr intake using ICRP models gave values of 70-100 kBq. From 1952 onwards, the differences in intakes calculated using the two approaches increased, reaching a factor of 2-3 in 1953. The Techa River data provide the basis for improving and adapting the ICRP models for application to Techa River-specific population.  相似文献   

16.
Fast neutrons (FN) have a higher radio-biological effectiveness (RBE) compared with photons, however the mechanism of this increase remains a controversial issue. RBE variations are seen among various FN facilities and at the same facility when different tissue depths or thicknesses of hardening filters are used. These variations lead to uncertainties in dose reporting as well as in the comparisons of clinical results. Besides radiobiology and microdosimetry, another powerful method for the characterization of FN beams is the calculation of total proton and heavy ion kerma spectra. FLUKA and MCNP Monte Carlo code were used to simulate these kerma spectra following a set of microdosimetry measurements performed at the National Accelerator Centre. The calculated spectra confirmed major classical statements: RBE increase is linked to both slow energy protons and alpha particles yielded by (n,alpha) reactions on carbon and oxygen nuclei. The slow energy protons are produced by neutrons having an energy between 10 keV and 10 MeV, while the alpha particles are produced by neutrons having an energy between 10 keV and 15 MeV. Looking at the heavy ion kerma from <15 MeV and the proton kerma from neutrons <10 MeV, it is possible to anticipate y* and RBE trends.  相似文献   

17.
Conversion coefficients from measurable quantities such as air kerma free-in-air or personal dose equivalent to effective dose were determined by phantom experiments. Heterogenic anthropomorphic phantoms representing children of one and five years age, and a Rando phantom representing an adult were exposed in the open field contaminated by different levels of radiocesium in the upper soil layer, in a forest site and inside a wooden house. LiF thermoluminescent (TL) detectors were used inside the phantoms for the estimation of organ doses and effective dose. Personal dosimeters similar to those used in radiation protection for individual dose measurements were placed onto the phantom surface (chest area). The ratios of dose values in separate organs to air kerma free-in-air varied from 0.69 to 1.15 for the children phantoms, and from 0.55 to 0.94 for the adult phantom, respectively, when irradiated in the open field. Body size (weight) was found to be the most important factor influencing the values of the conversion coefficients. The differences observed can reach approximately 40% when comparing conversion factors from air kerma free-in-air to effective dose for adults and newborns. For conversion coefficients from personal dose to effective dose, these differences can reach approximately 15%. The dependences of the various conversion coefficients on body mass were quantified by regression analysis. The results were compared with those calculated for a plane mono-energetic photon source having an energy of 700 keV and being located in the ground at a depth of 0.5 g cm−2. Calculated and measured conversion coefficients from air kerma free-in-air to effective dose agreed within 12%.  相似文献   

18.
A stationary sorption model has been developed for re-evaluating and analysing archive data from 1950-1951 on the radioactive contamination of Techa river bottom sediments close to the site of liquid radioactive waste discharge. In general, good agreement was obtained between calculations and measurements, which substantiates further the assumptions and conclusions in two preceding articles, on the radionuclide composition of discharged liquid radioactive waste. Estimates on the effective liquid radioactive waste discharges given here are significantly different from those deduced in the 1950s, i.e. in summer 1950 and October 1951. The results are discussed in relation to the Techa River Dosimetry System 2000 (TRDS-2000) that has recently been presented to serve as a means for estimating doses to the Techa river residents. Parameter values describing the exponential decrease of bottom sediment contamination along the river due to short-lived radionuclides, such as (106)Ru, and (144)Ce, agree reasonably with those used in TRDS-2000. However, for other radionuclides, such as (95)Zr, (95)Nb, (91)Y, (90)Sr and (137)Cs, substantial differences are found. It is demonstrated that water flow rate, width of the river, and surface area of bottom sediments are important parameters which were not adequately taken into account in TRDS-2000. Also, the stirring-up of contaminated bottom sediments and their subsequent transport by the water flow are seen to be an important mechanism that governs the radionuclide transport downstream. This mechanism was not included in the TRDS-2000 model. It is concluded that the sorption model used in TRDS-2000 for the reconstruction of radioactive contamination of water and bottom sediments of the Techa river in 1949-1951, is subject to considerable errors. While the present paper is focussed on details of the dosimetric modelling, the implications for the Techa river dosimetry are major. They will be further elucidated in a forthcoming paper.  相似文献   

19.
A new method is introduced for deriving radiocesium soil contaminations and kerma rates in air from in situ gamma-ray spectrometric measurements. The approach makes use of additional information about gamma-ray attenuation given by the peak-to-valley ratio, which is the ratio of the count rates for primary and forward scattered photons. In situ measurements are evaluated by comparing the experimental data with the results of Monte Carlo simulations of photon transport and detector response. The influence of photons emitted by natural radionuclides on the calculation of the peak-to-valley ratio is carefully analysed. The new method has been applied to several post-Chernobyl measurements and the results agreed well with those of soil sampling.  相似文献   

20.
Monte Carlo calculations are highly spread and settled practice to calculate brachytherapy sources dosimetric parameters. In this study, recommendations of the AAPM TG-43U1 report have been followed to characterize the Varisource VS2000 192Ir high dose rate source, provided by Varian Oncology Systems.In order to obtain dosimetric parameters for this source, Monte Carlo calculations with PENELOPE code have been carried out. TG-43 formalism parameters have been presented, i.e., air kerma strength, dose rate constant, radial dose function and anisotropy function. Besides, a 2D Cartesian coordinates dose rate in water table has been calculated. These quantities are compared to this source reference data, finding results in good agreement with them.The data in the present study complement published data in the next aspects: (i) TG-43U1 recommendations are followed regarding to phantom ambient conditions and to uncertainty analysis, including statistical (type A) and systematic (type B) contributions; (ii) PENELOPE code is benchmarked for this source; (iii) Monte Carlo calculation methodology differs from that usually published in the way to estimate absorbed dose, leaving out the track-length estimator; (iv) the results of the present work comply with the most recent AAPM and ESTRO physics committee recommendations about Monte Carlo techniques, in regards to dose rate uncertainty values and established differences between our results and reference data.The results stated in this paper provide a complete parameter collection, which can be used for dosimetric calculations as well as a means of comparison with other datasets from this source.  相似文献   