首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

In the present research we were interested to study the cerebral activity of a group of healthy subjects during the observation a documentary intermingled by a series of TV advertisements. In particular, we desired to examine whether Public Service Announcements (PSAs) are able to elicit a different pattern of activity, when compared with a different class of commercials, and correlate it with the memorization of the showed stimuli, as resulted from a following subject’s verbal interview.

Methods

We recorded the EEG signals from a group of 15 healthy subjects and applied the High Resolution EEG techniques in order to estimate and map their Power Spectral Density (PSD) on a realistic cortical model. The single subjects’ activities have been z-score transformed and then grouped to define four different datasets, related to subjects who remembered and forgotten the PSAs and to subjects who remembered and forgotten cars commercials (CAR) respectively, which we contrasted to investigate cortical areas involved in this encoding process.

Results

The results we here present show that the cortical activity elicited during the observation of the TV commercials that were remembered (RMB) is higher and localized in the left frontal brain areas when compared to the activity elicited during the vision of the TV commercials that were forgotten (FRG) in theta and gamma bands for both categories of advertisements (PSAs and CAR). Moreover, the cortical maps associated with the PSAs also show an increase of activity in the alpha and beta band.

Conclusions

In conclusion, the TV advertisements that will be remembered by the experimental population have increased their cerebral activity, mainly in the left hemisphere. These results seem to be congruent with and well inserted in the already existing literature, on this topic, related to the HERA model. The different pattern of activity in different frequency bands elicited by the observation of PSAs may be justified by the existence of additional cortical networks processing these kind of audiovisual stimuli. Further research with an extended set of subjects will be necessary to further validate the observations reported in this paper.
  相似文献   

2.
The identification of the networks connecting brain areas and the understanding of their role in executing complex tasks is a crucial issue in cognitive neuroscience. In this study, specific visuomotor tasks were devised to reveal the functional network underlying the cooperation process between visual and motor regions. Electroencephalography (EEG) data were recorded from twelve healthy subjects during a combined visuomotor task, which integrated precise grip motor commands with sensory visual feedback (VM). This condition was compared with control tasks involving pure motor action (M), pure visual perception (V) and visuomotor performance without feedback (V + M). Multivariate parametric cross-spectral analysis was applied to ten EEG derivations in each subject to assess changes in the oscillatory activity of the involved cortical regions and quantify their coupling. Spectral decomposition was applied to precisely and objectively determine the power associated with each oscillatory component of the spectrum, while surrogate data analysis was performed to assess the statistical significance of estimated coherence values. A significant decrease of the alpha and/or beta power in EEG spectra with respect to rest values was assumed as indicative of specific cortical area activation during task execution. Indeed alpha band coherence increased in proximity of task-involved areas, while it was suppressed or remained unchanged in other regions, suggesting the activation of a specific network for each task. According to our coherence analysis, a direct link between visual and motor areas was activated during V + M and VM tasks. The effect of visual feedback was evident in the beta band, where the increase of coherence was observed only during the VM task. Multivariate analysis suggested the presence of a functional link between motor and visual cortex subserving sensorimotor integration. Furthermore, network activation was related to the sum of single task (M and V) local effects in the alpha band, and to the presence of visual feedback in the beta band.  相似文献   

3.
The purpose of the present study was to determine how humans adjust leg stiffness over a range of hopping frequencies. Ten male subjects performed in place hopping on two legs, at three frequencies (1.5, 2.2, and 3.0 Hz). Leg stiffness, joint stiffness and touchdown joint angles were calculated from kinetic and/or kinematics data. Electromyographic activity (EMG) was recorded from six leg muscles. Leg stiffness increased with an increase in hopping frequency. Hip and knee stiffnesses were significantly greater at 3.0 Hz than at 1.5 Hz. There was no significant difference in ankle stiffness among the three hopping frequencies. Although there were significant differences in EMG activity among the three hopping frequencies, the largest was the 1.5 Hz, followed by the 2.2 Hz and then 3.0 Hz. The subjects landed with a straighter leg (both hip and knee were extended more) with increased hopping frequency. These results suggest that over the range of hopping frequencies we evaluated, humans adjust leg stiffness by altering hip and knee stiffness. This is accomplished by extending the touchdown joint angles rather than by altering neural activity.  相似文献   

4.
One of the major challenge in the detection of mental states is improving the accuracy of brain activity-based detectors with additional information from extracranial signals. We assessed the suitability, for real-time mental fatigue detection, of EEG, EOG and ECG measurements, taken separately or together. Thirteen subjects performed six blocks of switching tasks. For each participant, the block with the lowest error rate from the first two blocks and the block with the highest error rate from the last three blocks were discriminated with a machine learning algorithm (support vector machine). The classification scores obtained with ECG or EOG were greater than would be expected by chance (>50%) for time windows of at least 8 s. EEG was the best single mode of detection, with classification scores ranging from 80 ± 3% with a 4 s time window to 94 ± 2% with a 30 s time window. The addition of ECG and EOG features to EEG features significantly increased classification scores for short time windows (e.g., to 86 ± 3% with a 4 s time window, p < 0.001). For short time windows (up to 12 s), ECG significantly increased the discriminatory power of EEG, whereas EOG did not. These results demonstrate that mental state detection on the basis of extracerebral measurements is feasible and that a combination of EEG and ECG is particularly appropriate for the rapid detection of mental fatigue.  相似文献   

5.
Contemporary methods of atrial flutter (AFL), atrial tachycardia (AT), and atrial fibrillation (AF) monitoring, although superior to the standard 12-lead ECG and symptom-based monitoring, are unable to accurately discriminate between AF, AFL and AT. Thus, there is a need to develop accurate, automated, and comprehensive atrial arrhythmia detection algorithms using standard ECG recorders. To this end, we have developed a sensitive and real-time realizable algorithm for accurate AFL and AT detection using any standard electrocardiographic recording. Our novel method for automatic detection of atrial flutter and atrial tachycardia uses a Bayesian approach followed by a high resolution time–frequency spectrum. We find the TQ interval of the electrocardiogram (ECG) corresponding to atrial activity by using a particle filter (PF), and analyze the atrial activity with a high resolution time–frequency spectral method: variable frequency complex demodulation (VFCDM). The rationale for using a high-resolution time–frequency algorithm is that our approach tracks the time-varying fundamental frequency of atrial activity, where AT is within 2.0–4.0 Hz, AFL is within 4.0–5.3 Hz and NSR is found at frequencies less than 2.0 Hz. For classifications of AFL (n = 22), AT (n = 10) and normal sinus rhythms (NSR) (n = 29), we found that our approach resulted in accuracies of 0.89, 0.87 and 0.91, respectively; the overall accuracy was 0.88.  相似文献   

6.
《IRBM》2009,30(3):133-138
We introduce an anatomical and electrophysiological model of deep brain structures dedicated to magnetoencephalography (MEG) and electroencephalography (EEG) source imaging. So far, most imaging inverse models considered that MEG/EEG surface signals were predominantly produced by cortical, hence superficial, neural currents. Here we question whether crucial deep brain structures such as the basal ganglia and the hippocampus may also contribute to distant, scalp MEG and EEG measurements. We first design a realistic anatomical and electrophysiological model of these structures and subsequently run Monte-Carlo experiments to evaluate the respective sensitivity of the MEG and EEG to signals from deeper origins. Results indicate that MEG/EEG may indeed localize these deeper generators, which is confirmed here from experimental MEG data reporting on the modulation of alpha (10–12 Hz) brain waves.  相似文献   

7.
The purpose of the study was to investigate whether boys and men utilise different control strategies whilst hopping. Eleven boys (11–12 yr old) and ten men completed hopping at 1.5 Hz, 3.0 Hz and at their preferred frequency. A footswitch measured contact and flight times, from which leg stiffness was calculated. Simultaneously, surface electromyograms (EMGs) of selected lower limb muscles were recorded and quantified for each 30 ms period during the first 120 ms post-ground contact. At 1.5 Hz there were no differences between the groups in relative stiffness or muscle activity. At 3.0 Hz men had significantly shorter contact times (P = 0.013), longer flight times (P = 0.002), greater relative stiffness (P = 0.01) and significantly greater soleus (P = 0.012) and vastus lateralis (P < 0.001) activity during the initial 30 ms post-ground contact. At the preferred frequency men hopped significantly faster than the boys (P = 0.007), with greater leg stiffness (P < 0.01) and with more extensor activity in most time periods. Boys and men demonstrated similar control strategies when hopping at a slow frequency, but when hopping frequency increased men were able to better increase feedforward and reflex muscle activity to hop with greater relative stiffness.  相似文献   

8.
The use of surface electromyography (SEMG) in vibration studies is problematic since motion artifacts occupy the same frequency band with the SEMG signal containing information on synchronous motor unit activity. We hypothesize that using a harsher, 80–500 Hz band-pass filter and using rectification can help eliminate motion artifacts and provide a way to observe synchronous motor unit activity that is phase locked to vibration using SEMG recordings only. Multi Motor Unit (MMU) action potentials using intramuscular electrodes along with SEMG were recorded from the gastrocnemius medialis (GM) of six healthy male volunteers. Data were collected during whole body vibration, using vibration frequencies of 30 Hz, 35 Hz, 40 Hz or 50 Hz. A computer simulation was used to investigate the efficacy of filtering under different scenarios: with or without artifacts and/or motor unit synchronization. Our findings indicate that motor unit synchronization took place during WBV as verified by MMU recordings. A harsh filtering regimen along with rectification proved successful in demonstrating motor unit synchronization in SEMG recordings. Our findings were further supported by the results from the computer simulation, which indicated that filtering and rectification was efficient in discriminating motion artifacts from motor unit synchronization. We suggest that the proposed signal processing technique may provide a new methodology to evaluate the effects of vibration treatments using only SEMG. This is a major advantage, as this non-intrusive method is able to overcome movement artifacts and also indicate the synchronization of underlying motor units.  相似文献   

9.
The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45 s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40 Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33 Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33 Hz is a resonance frequency for the hand-arm system.  相似文献   

10.
In this study, the effects of mental fatigue on mechanically induced tremor at both a low (3–6 Hz) and high (8–12 Hz) frequency were investigated. The two distinct tremor frequencies were evoked using two springs of different stiffness, during 20 s sustained contractions of the knee extensor muscles at 30% maximum voluntary contraction (MVC) before and after 100 min of a mental fatigue task, in 12 healthy (29 ± 3.7 years) participants. Mental fatigue resulted in a 6.9% decrease in MVC and in a 9.4% decrease in the amplitude of the agonist muscle EMG during sustained 30% MVC contractions in the induced high frequency only. Following the mental fatigue task, the coefficient of variation and standard deviation of the force signal decreased at 8–12 Hz induced tremor by 31.7% and 35.2% respectively, but not at 3–6 Hz induced tremor. Similarly, the maximum value and area underneath the peak in the power spectrum of the force signal decreased by 55.5% and 53.1% respectively in the 8–12 Hz range only. In conclusion, mental fatigue decreased mechanically induced 8–12 Hz tremor and had no effect on induced 3–6 Hz tremor. We suggest that the reduction could be attributed to the decreased activation of the agonist muscles.  相似文献   

11.
IntroductionHuntington’s disease (HD) patients have difficulty in swallowing, leading to aspiration pneumonia, which is a major cause of death. It seems possible that submental muscles that are crucial for preventing an escape of a bolus into the airway, are affected by HD, but no previous studies have investigated this.ObjectiveTo assess surface electromyograph (sEMG) activity of submental muscles during swallowing and expiratory muscle training (EMT) tasks in HD patients in comparison to healthy volunteers.MethodssEMG activities of submental muscles during saliva, water swallowing, EMT tasks performed at 25% and 75% of maximum expiratory pressure were recorded and normalised by the sEMG activity during an effortful swallow in 17 early to mid stage HD patients and 17 healthy volunteers.ResultssEMG activity was greater (p < 0.05) during EMT tasks than saliva and water swallowing, but was not significantly different between groups for saliva, water swallowing and EMT at 25%. HD patients had lower sEMG activity for EMT at 75% (p < 0.05).ConclusionDecreases in submental muscle activity were not evident in HD patients except during EMT at 75%. This suggests that relative submental muscle weakness is observed only during a high intensity task in early to mid stage HD patients.  相似文献   

12.
Oh ES  Seo YK  Yoon HH  Cho H  Yoon MY  Park JK 《Life sciences》2011,88(3-4):169-177
AimsAlthough low and high intensity sub-sonic vibrations (SSV) have been shown to facilitate wound healing, very few studies have investigated the effects of SSV on 3T3-L1 preadipocytes. Therefore, the present study was undertaken to investigate the influence of SSV on the proliferation and maturation of 3T3-L1 preadipocytes.Main methodsTo evaluate the effect of SSV on 3T3-L1 cell proliferation, the cells were maintained in an apparatus that administered SSV (0.5 V) for 3 days at a frequency of 10, 20, 30, or 40 Hz. In addition, to study the effect of SSV on 3T3-L1 cell maturation, the cells were stimulated with SSV for 6 days at a frequency of 10, 20, 30, or 45 Hz.Key findingsSub-sonic vibrations inhibited the proliferation of 3T3-L1 preadipocytes at frequencies of 20 and 30 Hz. Triglyceride levels in cells subjected to SSV at frequencies ranging from 10 to 30 Hz increased compared with those measured in control cells. The expression of adipogenic genes, such as PPAR-γ and C/EBP-α, markedly increased in response to SSV at 20 Hz and 30 Hz during maturation.SignificanceThese results suggest that SSV affected adipogenic gene expression at 20 and 30 Hz.  相似文献   

13.
Whole body vibration (WBV) during exercise offers potential to augment the effects of basic exercises. However, to date there is limited information on the basic physiological and biomechanical effects of WBV on skeletal muscles. The aim of this study was to determine the effects of WBV (40 Hz, 1.9 mm synchronous vertical displacement) on the myoelectrical activity of selected plantarflexors during heel raise exercise. 3D motion capture of the ankle, synchronised with sEMG of the lateral gastrocnemius and soleus, was obtained during repetitive heel raises carried out at 0.5 Hz on 10 healthy male subjects (age 27 ± 5 years, height 1.78 ± 0.04 m, weight 75.75 ± 11.9 kg). During both vibration and non vibration the soleus activation peaked earlier than that of the lateral gastrocnemius. The results indicate that WBV has no effect on the timing of exercise completion or the amplitude of the lateral gastrocnemius activity, however significant increases in amplitudes of the soleus muscle activity (77.5–90.4% MVC P < 0.05). WBV had no significant effect on median frequencies of either muscle. The results indicate that the greatest effect of WBV during heel raise activity is in the soleus muscles during the early phases of heel raise.  相似文献   

14.
Novel, chiral derivatives of pyrrolo[1,2-a]pyrazine with aromatic substituents at carbon C-4 were synthesized by a short synthetic sequence involving Ugi multicomponent reaction. The compounds were evaluated for their in vivo efficacy in animal models of epilepsy within the Anticonvulsant Screening Program (ASP). High activity in ‘classical’ maximal electroshock seizure (MES) and subcutaneous Metrazol (scMET) tests was characteristic for meta-substituted analogs. On the other hand, efficacy of compounds in the 6 Hz model of pharmacoresistant limbic seizures was only marginally affected by the orientation of substituents in the phenyl moiety. The most active derivative, 5a, displayed an ED50 value of 32.24 mg/kg and a protective index of 6.6 (PI) in the 6 Hz test. It was also active in a pilocarpine-induced status prevention model of pharmacoresistant status epilepticus.  相似文献   

15.
Compared to intact limbs, running-specific prostheses have high resonance non-biologic materials and lack active tissues to damp high frequencies. These differences may lead to ground reaction forces (GRFs) with high frequency content. If so, ubiquitously applying low-pass filters to prosthetic and intact limb GRFs may attenuate veridical high frequency content and mask important and ecologically valid data from prostheses. To explore differences in frequency content between prosthetic and intact limbs we divided signal power from transtibial unilateral amputees and controls running at 2.5, 3.0, and 3.5 m/s into Low (<10 Hz), High (10–25 Hz), and Non-biologic (>25 Hz) frequency bandwidths. Faster speeds tended to reduce the proportion of signal power in the Low bandwidth while increasing it in the High and Non-biologic bandwidths. Further, prostheses had lower proportions of signal power at the High frequency bandwidth but greater proportions at the Non-biologic bandwidth. To evaluate whether these differences in frequency content interact with filter cut-offs and alter results, we filtered GRFs with cut-offs from 1 to 100 Hz and calculated vertical impact peak (VIP). Changing cut-off had inconsistent effects on VIP across speeds and limbs: Faster speeds had significantly larger changes in VIP per change in cut-off while, compared to controls, prosthetic limbs had significantly smaller changes in VIP per change in cut-off. These findings reveal differences in GRF frequency content between prosthetic and intact limbs and suggest that a cut-off frequency that is appropriate for one limb or speed may be inappropriate for another.  相似文献   

16.
The time course of alteration in neuromuscular function of the knee extensor muscles was characterized during a prolonged intermittent exercise. Maximal voluntary contraction (MVC) and surface EMG activity of both vastii were measured during brief interruptions before (T0), during (30, 60, 90, 120, 150 and 180 min: T30, T60, T90, T120, T150, T180) and 30 min after (T+30) a 3 h tennis match in 12 trained players. M-wave and twitch contractile properties were analyzed following single stimuli. Short tetani at 20 Hz and 80 Hz were also applied to six subjects at T0 and T180. Significant reductions in MVC (P < 0.05; −9%) and electromyographic activity normalized to the M wave for both vastii (P < 0.01) occurred with fatigue at T180. No significant changes in M-wave duration and amplitude nor in twitch contractile properties were observed. The ratio between the torques evoked by 20 Hz and 80 Hz stimulation declined significantly (P < 0.001; −12%) after exercise. Central activation failure and alterations in excitation–contraction coupling are probable mechanisms contributing to the moderate impairment of the neuromuscular function during prolonged tennis playing.  相似文献   

17.
AimsThis study investigates the effects of vagus nerve stimulation (VNS) on seizure severity and blood–brain barrier (BBB) integrity in kindled rats with cortical dysplasia (CD).Main methodsPregnant rats were exposed to 145 cGy of gamma-irradiation on day 17 of pregnancy. In offsprings, kindling was induced by giving subconvulsive doses of pentylenetetrazole. Left VNS was performed for 48 h at output currents of 0.5 or 1 mA. Horseradish peroxidase (HRP) was used to study the BBB permeability. Immunohistochemistry for occludin and P-glycoprotein (P-gp) was also performed.Key findingsKindled rats with CD exhibited seizures with mean Racine's scores of 3.57 ± 1.2 during video EEG recording. Kindled animals with CD receiving VNS at 0.5 and 1.0 mA did not exhibit either clinical or electrophysiological signs of seizure. Immunostaining for occludin, a tight junction protein, in hippocampus remained relatively intact in all groups. VNS-treated and -untreated kindled animals with CD revealed intense immunostaining for P-gp in hippocampal formation (P < 0.01). Electron microscopic observations revealed frequent transport vesicles containing electron-dense HRP reaction products in the cytoplasm of brain capillary endothelial cells in both cerebral cortex and hippocampus of kindled animals with CD. Those which were exposed to 1 mA VNS were observed to have brain capillary endothelial cells largely devoid of HRP reaction products in both cerebral cortex and hippocampus.SignificanceThe results of this study suggest that VNS therapy at 1 mA inhibits seizure activity and protects BBB integrity by limiting the enhancement of transcellular pathway in kindled animals with CD.  相似文献   

18.
Electromyographic (EMG) studies into gluteus medius (GMed) typically involve surface EMG electrodes. Previous comparisons of surface and fine wire electrode recordings in other muscles during high load isometric tasks suggest that recordings between electrodes are comparable when the muscle is contracting at a high intensity, however, surface electrodes record additional activity when the muscle is contracting at a low intensity. The purpose of this study was to compare surface and fine wire recordings of GMed at high and low intensities of muscle contractions, under high load conditions (maximum voluntary isometric contractions, MVICs). Mann–Whitney U tests compared median electrode recordings during three MVIC hip actions; abduction, internal rotation and external rotation, in nine healthy adults. There were no significant differences between electrode recordings in positions that evoked a high intensity contraction (internal rotation and abduction, fine wire activity >77% MVIC; effect size, ES < 0.42; p > 0.277). During external rotation, the intensity of muscle activity was low (4.2% MVIC), and surface electrodes recorded additional myoelectric activity (ES = 0.67, p = 0.002). At low levels of muscle activity during high load isometric tasks, the use of surface electrodes may result in additional myoelectric recordings of GMed, potentially reflective of cross-talk from surrounding muscles.  相似文献   

19.
This work aimed to characterise the whole human muscle input/output law during electrical stimulation with triangular varying frequency and amplitude trains through combined analysis of torque, mechanomyogram (MMG) and electromyogram (EMG).The tibialis anterior (TA) of ten subjects (age 23–35 years) was investigated during static contraction obtained through neuromuscular electrical stimulation. After potentiation, TA underwent two 15 s stimulation patterns: (a) frequency triangle (FT): 2 > 35 > 2 Hz at Vmax (amplitude providing full motor unit recruitment); (b) amplitude triangle (AT): Vmin > Vmax > Vmin (Vmin providing TA least mechanical response) at 35 Hz. 2 > 35 Hz or Vmin > Vmax as well as 35 > 2 Hz or Vmax > Vmin were defined as up-going ramp (UGR) and down-going ramp (DGR), respectively. TA torque, MMG and EMG were detected by a load cell, an optical laser distance sensor and a probe with two silver bar electrodes, respectively. For both FT and AT, only the two mechanical signals resulted always larger in DGR than in UGR, during AT extra-torque and extra-MMG were present even in the first 1/3 of the amplitude range where EMG data presented no significant differences between DGR and UGR.Our data suggest that extra-torque and extra-displacement are evident for both FT and AT, being mainly attributed to an intrinsic muscle property.  相似文献   

20.
How do synergistic muscles interact, when their contraction aims at stabilizing and fine-tuning a movement, which is induced by the antagonistic muscle? The aim of the study was to analyze the interaction of biceps and brachioradialis during fine-tuning control tasks in comparison to load bearing ones. The surface electromyogram of biceps, brachioradialis and triceps were examined in 15 healthy subjects in dynamic flexion and extension movements with different combinations of contraction levels, joint angles and angular velocities. The measurements were conducted in two configurations, where the torque due to an external load opposes the rotational direction of the elbow flexion (load bearing tasks) or the elbow extension (fine-tuning tasks).Whereas during load bearing control tasks, similar muscular activation of biceps and brachioradialis was observed for all joint angles, angular velocities and external loads, during fine-tuning control tasks a significant difference of the muscular activation of both flexors was observed for 1 kg, F(3.639, 47.305) = 2.864, p = 0.037, and 5 kg of external load, F(1.570, 21.976) = 6.834, p = 0.008.The results confirm the synergistic muscular activation of both flexors during load bearing tasks, but suggest different control strategies for both flexors when they comprise a fine-tuning control task.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号