首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fluorescence correlation spectroscopy (FCS) extracts information about molecular dynamics from the tiny fluctuations that can be observed in the emission of small ensembles of fluorescent molecules in thermodynamic equilibrium. Employing a confocal setup in conjunction with highly dilute samples, the average number of fluorescent particles simultaneously within the measurement volume (approximately 1 fl) is minimized. Among the multitude of chemical and physical parameters accessible by FCS are local concentrations, mobility coefficients, rate constants for association and dissociation processes, and even enzyme kinetics. As any reaction causing an alteration of the primary measurement parameters such as fluorescence brightness or mobility can be monitored, the application of this noninvasive method to unravel processes in living cells is straightforward. Due to the high spatial resolution of less than 0.5 microm, selective measurements in cellular compartments, e.g., to probe receptor-ligand interactions on cell membranes, are feasible. Moreover, the observation of local molecular dynamics provides access to environmental parameters such as local oxygen concentrations, pH, or viscosity. Thus, this versatile technique is of particular attractiveness for researchers striving for quantitative assessment of interactions and dynamics of small molecular quantities in biologically relevant systems.  相似文献   

2.
Pramanik A  Olsson M  Langel U  Bartfai T  Rigler R 《Biochemistry》2001,40(36):10839-10845
Fluorescence correlation spectroscopy (FCS) allows the study of interactions of fluorescently labeled ligand with receptors in living cells at single-molecule detection sensitivity. From the autocorrelation functions of fluorescence intensity fluctuations, the diffusion time of molecules through the confocal volume is analyzed, and from that, the molecular weights of free and bound molecules can be calculated. We have applied FCS to study the receptor diversity for the neuropeptide galanin (GAL) in cultured cells. FCS measurement of the fluorophore rhodamine-labeled GAL (Rh-GAL) has been performed in 0.2-fL confocal volume elements of the laser beam. The analysis of autocorrelation functions of Rh-GAL in solution above cells and at cell membranes demonstrates that the diffusion time of unbound Rh-GAL is 0.16 ms, whereas diffusion times of membrane-bound Rh-GAL are 22 and 700 ms. Because both of the diffusion times (22 and 700 ms) are much longer as compared to that of unbound Rh-GAL, they correspond to slow-diffusing complexes when Rh-GAL is bound to the cell membranes. Addition of excess nonlabeled GAL is accompanied by competitive displacement. Full saturation of the GAL binding is obtained at nanomolar concentrations. Scatchard analysis of binding data reveal one binding process, assuming one binding site per Rh-GAL (n = 1). On the other hand, the appearance of two diffusion times, 22 and 700 ms, suggests the existence of two subpopulations of GAL receptor complexes or two subtypes of GAL receptor not detected before. This makes an important point that FCS permits the identification of receptors, which were not possible to detect before by conventional binding techniques. The inhibitory effect of pertussis toxin on the GAL binding considers a G-protein-involved allosteric system, important for the clarification of essential steps in the G-protein-related signal transduction. This study is of pharmaceutical significance, since it will provide insights into how FCS can be used as a rapid technique for studying ligand-receptor interactions in living cells, which is one step forward for large-scale drug screening in cell cultures.  相似文献   

3.
Fluorescence correlation spectroscopy (FCS) is becoming increasingly popular as a technique that aims at complementing live cell images with biophysical information. This article provides both a short overview over recent intracellular FCS applications and a practical guide for investigators, who are seeking to integrate FCS into live cell imaging to obtain information on particle mobility, local concentrations, and molecular interactions. A brief introduction to the principles of FCS is provided, particularly emphasizing practical aspects such as the choice of appropriate dyes and positioning of the measurement volume in the sample. Possibilities and limitations in extracting parameters from autocorrelation curves are discussed, and attention is drawn to potential artifacts, such as photobleaching and probe aggregation. The principle of dual-color cross-correlation is reviewed along with considerations for proper setup and adjustment. Practical implications of nonideal conditions including incomplete focus overlap and spectral cross-talk are considered. Recent examples of both auto- and cross-correlation applications demonstrate the potential of FCS for cell biology.  相似文献   

4.
Fluorescence correlation spectroscopy and quantitative cell biology   总被引:2,自引:0,他引:2  
Fluorescence correlation spectroscopy (FCS) analyzes fluctuations in fluorescence within a small observation volume. Autocorrelation analysis of FCS fluctuation data can be used to measure concentrations, diffusion properties, and kinetic constants for individual fluorescent molecules. Photon count histogram analysis of fluorescence fluctuation data can be used to study oligomerization of individual fluorescent molecules. If the FCS observation volume is positioned inside a living cell, these parameters can be measured in vivo. FCS can provide the requisite quantitative data for analysis of molecular interaction networks underlying complex cell biological processes.  相似文献   

5.
We have developed a program for the simulation of the fluorescence fluctuations as detected from highly diluted samples of (bio)molecules. The model is applied to translational diffusion and takes into account the hydrodynamic interactions. The solution concentration is kept constant by assuming periodic boundary conditions and spans here the range 0.5< C < 10 nM. We show that the fluorescence correlation functions can be accurately computed on systems of limited size (a few molecules per simulation box) by simulating for a total time approximately 100-300 times the diffusion relaxation time of the fluorescence autocorrelation function. The model is applied also to the simulation of the scanning fluorescence correlation spectroscopy (FCS) and of the photon counting histograms for the confocal collection configuration. Scanning FCS simulations of highly diluted samples (C approximately equals 0.5 nM) show anticorrelation effects in the autocorrelation functions of the fluorescence signal that are less evident for higher concentrations. We suggest here that this effect may be due to the non-uniform occupancy of the scanning area by the fluorophores.  相似文献   

6.
Elson EL 《Biophysical journal》2011,(12):2855-2870
In recent years fluorescence correlation spectroscopy (FCS) has become a routine method for determining diffusion coefficients, chemical rate constants, molecular concentrations, fluorescence brightness, triplet state lifetimes, and other molecular parameters. FCS measures the spatial and temporal correlation of individual molecules with themselves and so provides a bridge between classical ensemble and contemporary single-molecule measurements. It also provides information on concentration and molecular number fluctuations for nonlinear reaction systems that complement single-molecule measurements. Typically implemented on a fluorescence microscope, FCS samples femtoliter volumes and so is especially useful for characterizing small dynamic systems such as biological cells. In addition to its practical utility, however, FCS provides a window on mesoscopic systems in which fluctuations from steady states not only provide the basis for the measurement but also can have important consequences for the behavior and evolution of the system. For example, a new and potentially interesting field for FCS studies could be the study of nonequilibrium steady states, especially in living cells.  相似文献   

7.
Fluorescence correlation spectroscopy (FCS) is a powerful technique to study dynamic biomolecular processes. It allows the estimation of concentrations, diffusion coefficients, molecular interactions, and other processes causing fluctuations in the fluorescence intensity, thus yielding information about aggregation processes, enzymatic reactions, or partition coefficients. During the last years, FCS has been successfully applied to model and cellular membranes, proving to be a promising tool for the study of membrane dynamics and protein/lipid interactions. Here we describe the theoretical basis of FCS and some practical implications for its application in membrane studies. We discuss sources of potential artifacts, such as membrane undulations, positioning of the detection volume, and photobleaching. Special attention is paid to aspects related to instrumentation and sample preparation as well as data acquisition and analysis. Finally, we comment on some strategies recently developed for the specific improvement of FCS measurements on membranes.  相似文献   

8.
Fluorescence Correlation Spectroscopy Measures Molecular Transport in Cells   总被引:3,自引:0,他引:3  
Fluorescence correlation spectroscopy (FCS) can measure dynamics of fluorescent molecules in cells. FCS measures the fluctuations in the number of fluorescent molecules in a small volume illuminated by a thin beam of excitation light. These fluctuations are processed statistically to yield an autocorrelation function from which rates of diffusion, convection, chemical reaction, and other processes can be extracted. The advantages of this approach include the ability to measure the mobility of a very small number of molecules, even down to the single molecule level, over a wide range of rates in very small regions of a cell. In addition to rates of diffusion and convection, FCS also provides unique information about the local concentration, states of aggregation and molecular interaction using fluctuation amplitude and cross-correlation methods. Recent advances in technology have rendered these once difficult measurements accessible to routine use in cell biology and biochemistry. This review provides a summary of the FCS method and describes current areas in which the FCS approach is being extended beyond its original scope.  相似文献   

9.
荧光相关谱技术及其应用   总被引:3,自引:1,他引:2  
基于对处于平衡态少量荧光分子集合的强度涨落进行时间平均的技术,荧光相关谱fluoreswceance correlation spectroscopy,FCS)技术最近已经应用于细胞环境过程的研究。FCS优秀的灵敏特性为我们实时测量许多参数提供了途径,而且具有快速的时间特性和高空间分辨率。测量的参数包括扩散速率、局部浓度、聚合状态和分子间的相互作用。荧光互相关谱(fluorescence cross-correlation spectroscopy,FCCS)进一步扩展了FCS技术的应用,包括在活细胞中的广泛应用。本文介绍了FCS技术的原理、实验装置及其应用。  相似文献   

10.
Fluorescence correlation spectroscopy (FCS) analyzes spontaneous fluctuations in the fluorescence emission of small molecular ensembles, thus providing information about a multitude of parameters, such as concentrations, molecular mobility and dynamics of fluorescently labeled molecules. Performed within diffraction-limited confocal volume elements, FCS provides an attractive alternative to photobleaching recovery methods for determining intracellular mobility parameters of very low quantities of fluorophores. Due to its high sensitivity sufficient for single molecule detection, the method is subject to certain artifact hazards that must be carefully controlled, such as photobleaching and intramolecular dynamics, which introduce fluorescence flickering. Furthermore, if molecular mobility is to be probed, nonspecific interactions of the labeling dye with cellular structures can introduce systematic errors. In cytosolic measurements, lipophilic dyes, such as certain rhodamines that bind to intracellular membranes, should be avoided. To study free diffusion, genetically encoded fluorescent labels such as green fluorescent protein (GFP) or DsRed are preferable since they are less likely to nonspecifically interact with cellular substructures.  相似文献   

11.
R Brock  M A Hink    T M Jovin 《Biophysical journal》1998,75(5):2547-2557
Fluorescence correlation microscopy (FCM), the combination of fluorescence correlation spectroscopy (FCS) and digital microscopy (Brock and Jovin, 1998. Cell. Mol. Biol. 44:847-856), has been implemented for measuring molecular diffusion and association in living cells with explicit consideration of autocorrelations arising from autofluorescence. Autofluorescence excited at 532 nm colocalizes with mitochondria, has flavin-like spectral characteristics, exhibits relaxation times characteristic for the diffusion of high-molecular-weight proteins, and depends on the incubation conditions of the cells. These time- and location-dependent properties preclude the assignment of universal background parameters. The lower limit for detection of microinjected dextran molecules labeled with the carboxymethylindocyanine dye Cy3 was a few thousand molecules per cell, and the diffusion constant of 1.7 x 10(-7) cm2/s agreed well with values measured with other methods. Based on the fluorescence signal per molecule (fpm) and the molecule number derived from autocorrelation analysis, a new method is devised to define intracellular association states. We conclude that FCM is a powerful, noninvasive method for probing molecular interactions in femtoliter volume elements within defined subcellular locations in living cells.  相似文献   

12.
Details about molecular membrane dynamics in living cells, such as lipid-protein interactions, are often hidden from the observer because of the limited spatial resolution of conventional far-field optical microscopy. The superior spatial resolution of stimulated emission depletion (STED) nanoscopy can provide new insights into this process. The application of fluorescence correlation spectroscopy (FCS) in focal spots continuously tuned down to 30 nm in diameter distinguishes between free and anomalous molecular diffusion due to, for example, transient binding of lipids to other membrane constituents, such as lipids and proteins. We compared STED-FCS data recorded on various fluorescent lipid analogs in the plasma membrane of living mammalian cells. Our results demonstrate details about the observed transient formation of molecular complexes. The diffusion characteristics of phosphoglycerolipids without hydroxyl-containing headgroups revealed weak interactions. The strongest interactions were observed with sphingolipid analogs, which showed cholesterol-assisted and cytoskeleton-dependent binding. The hydroxyl-containing headgroup of gangliosides, galactosylceramide, and phosphoinositol assisted binding, but in a much less cholesterol- and cytoskeleton-dependent manner. The observed anomalous diffusion indicates lipid-specific transient hydrogen bonding to other membrane molecules, such as proteins, and points to a distinct connectivity of the various lipids to other membrane constituents. This strong interaction is different from that responsible for forming cholesterol-dependent, liquid-ordered domains in model membranes.  相似文献   

13.
The cytoskeleton of eukaryotic cells is continuously remodeled by polymerization and depolymerization of actin. Consequently, the relative content of polymerized filamentous actin (F-actin) and monomeric globular actin (G-actin) is subject to temporal and spatial fluctuations. Since fluorescence correlation spectroscopy (FCS) can measure the diffusion of fluorescently labeled actin it seems likely that FCS allows us to determine the dynamics and hence indirectly the structural properties of the cytoskeleton components with high spatial resolution. To this end we investigate the FCS signal of GFP-actin in living Dictyostelium discoideum cells and explore the inherent spatial and temporal signatures of the actin cytoskeleton. Using the free green fluorescent protein (GFP) as a reference, we find that actin diffusion inside cells is dominated by G-actin and slower than diffusion in diluted cell extract. The FCS signal in the dense cortical F-actin network near the cell membrane is probed using the cytoskeleton protein LIM and is found to be slower than cytosolic G-actin diffusion. Furthermore, we show that polymerization of the cytoskeleton induced by Jasplakinolide leads to a substantial decrease of G-actin diffusion. Pronounced fluctuations in the distribution of the FCS correlation curves can be induced by latrunculin, which is known to induce actin waves. Our work suggests that the FCS signal of GFP-actin in combination with scanning or spatial correlation techniques yield valuable information about the local dynamics and concomitant cytoskeletal properties.  相似文献   

14.
Giant unilamellar vesicles (GUVs) have been widely used as a model membrane system to study membrane organization, dynamics, and protein-membrane interactions. Most recent studies have relied on imaging methods, which require good contrast for image resolution. Multiple sequential image processing only detects slow components of membrane dynamics. We have developed a new fluorescence correlation spectroscopy (FCS) technique, termed scanning FCS (i.e., SFCS), which performs multiple FCS measurements simultaneously by rapidly directing the excitation laser beam in a uniform (circular) scan across the bilayer of the GUVs in a repetitive fashion. The scan rate is fast compared to the diffusion of the membrane proteins and even small molecules in the GUVs. Scanning FCS outputs a "carpet" of timed fluorescence intensity fluctuations at specific points along the scan. In this study, GUVs were assembled from rat kidney brush border membranes, which included the integral membrane proteins. Scanning FCS measurements on GUVs allowed for a straightforward detection of spatial-temporal interactions between the protein and the membrane based on the diffusion rate of the protein. To test for protein incorporation into the bilayers of the GUVs, antibodies against one specific membrane protein (NaPi II cotransporter) were labeled with ALEXA-488. Fluorescence images of the GUVs in the presence of the labeled antibody showed marginal fluorescence enhancement on the GUV membrane bilayers (poor image contrast and resolution). With the application of scanning FCS, the binding of the antibody to the GUVs was detected directly from the analysis of diffusion rates of the fluorescent antibody. The diffusion coefficient of the antibody bound to NaPi II in the GUVs was approximately 200-fold smaller than that in solution. Scanning FCS provided a simple, quantitative, yet highly sensitive method to study protein-membrane interactions.  相似文献   

15.
Fluorescence correlation spectroscopy (FCS) is a powerful technique to measure chemical reaction rates and diffusion coefficients of molecules in thermal equilibrium. The capabilities of FCS can be enhanced by measuring the energy, polarization, or delay time between absorption and emission of the collected fluorescence photons in addition to their arrival times. This information can be used to change the relative intensities of multiple fluorescent species in FCS measurements and, thus, the amplitude of the intensity autocorrelation function. Here we demonstrate this strategy using lifetime gating in FCS experiments. Using pulsed laser excitation and laser-synchronized gating in the detection channel, we suppress photons emitted within a certain time interval after excitation. Three applications of the gating technique are presented: suppression of background fluorescence, simplification of FCS reaction studies, and investigation of lifetime heterogeneity of fluorescently labeled biomolecules. The usefulness of this technique for measuring forward and backward rates of protein fluctuations in equilibrium and for distinguishing between static and dynamic heterogeneity makes it a promising tool in the investigation of chemical reactions and conformational fluctuations in biomolecules.  相似文献   

16.
BACKGROUND: Because the process of protein translation is an event of sparse molecules, the measurement requires high sensitivity. One of the candidates for studying the molecules is fluorescence correlation spectroscopy (FCS), which gleans quantitative information from fluctuating fluorescence signals in a diluted solution. METHODS: Using FCS, the translation products of expression plasmid for green fluorescent protein (GFP) and its fusion proteins were measured in vitro and in vivo. RESULTS: In in vitro translation, the number of products increased linearly for 90 min upon concentration of the plasmid. The autocorrelation function for GFP was fitted with a one-component model with a diffusion time of 0.18 ms, which was identical to the value expected from the molecular weight. In the cases of GFP- tagged hypoxia-inducible factor-1 alpha and glucocorticoid receptor, each fitting result was significantly improved with a two-component model. The slow component with a diffusion time of 6 ms appeared to be related to the ribosome or polysome. In response to the addition of dexamethasone, the nuclear translocation from cytosol clearly induced the decrease in number of molecules in the focal point. CONCLUSIONS: FCS permits monitoring of the number of molecules translated in vitro and in vivo, the translation rate, and the molecular weight.  相似文献   

17.
Hess ST  Webb WW 《Biophysical journal》2002,83(4):2300-2317
Fluorescence correlation spectroscopy (FCS) can provide a wealth of information about biological and chemical systems on a broad range of time scales (<1 micros to >1 s). Numerical modeling of the FCS observation volume combined with measurements has revealed, however, that the standard assumption of a three-dimensional Gaussian FCS observation volume is not a valid approximation under many common measurement conditions. As a result, the FCS autocorrelation will contain significant, systematic artifacts that are most severe with confocal optics when using a large detector aperture and aperture-limited illumination. These optical artifacts manifest themselves in the fluorescence correlation as an apparent additional exponential component or diffusing species with significant (>30%) amplitude that can imply extraneous kinetics, shift the measured diffusion time by as much as approximately 80%, and cause the axial ratio to diverge. Artifacts can be minimized or virtually eliminated by using a small confocal detector aperture, underfilled objective back-aperture, or two-photon excitation. However, using a detector aperture that is smaller or larger than the optimal value (approximately 4.5 optical units) greatly reduces both the count rate per molecule and the signal-to-noise ratio. Thus, there is a tradeoff between optimizing signal-to-noise and reducing experimental artifacts in one-photon FCS.  相似文献   

18.
Continuous fluorescence microphotolysis (CFM) and fluorescence correlation spectroscopy (FCS) permit measurement of molecular mobility and association reactions in single living cells. CFM and FCS complement each other ideally and can be realized using identical equipment. So far, the spatial resolution of CFM and FCS was restricted by the resolution of the light microscope to the micrometer scale. However, cellular functions generally occur on the nanometer scale. Here, we develop the theoretical and computational framework for CFM and FCS experiments using 4Pi microscopy, which features an axial resolution of ∼100 nm. The framework, taking the actual 4Pi point spread function of the instrument into account, was validated by measurements on model systems, employing 4Pi conditions or normal confocal conditions together with either single- or two-photon excitation. In all cases experimental data could be well fitted by computed curves for expected diffusion coefficients, even when the signal/noise ratio was small due to the small number of fluorophores involved.  相似文献   

19.
The architectural organization of chromatin can play an important role in genome regulation by affecting the mobility of molecules within its surroundings via binding interactions and molecular crowding. The diffusion of molecules at specific locations in the nucleus can be studied by fluorescence correlation spectroscopy (FCS), a well-established technique based on the analysis of fluorescence intensity fluctuations detected in a confocal observation volume. However, detecting subtle variations of mobility between different chromatin regions remains challenging with currently available FCS methods. Here, we introduce a method that samples multiple positions by slowly scanning the FCS observation volume across the nucleus. Analyzing the data in short time segments, we preserve the high temporal resolution of single-point FCS while probing different nuclear regions in the same cell. Using the intensity level of the probe (or a DNA marker) as a reference, we efficiently sort the FCS segments into different populations and obtain average correlation functions that are associated to different chromatin regions. This sorting and averaging strategy renders the method statistically robust while preserving the observation of intranuclear variations of mobility. Using this approach, we quantified diffusion of monomeric GFP in high versus low chromatin density regions. We found that GFP mobility was reduced in heterochromatin, especially within perinucleolar heterochromatin. Moreover, we found that modulation of chromatin compaction by ATP depletion, or treatment with solutions of different osmolarity, differentially affected the ratio of diffusion in both regions. Then, we used the approach to probe the mobility of estrogen receptor-α in the vicinity of an integrated multicopy prolactin gene array. Finally, we discussed the coupling of this method with stimulated emission depletion FCS for performing FCS at subdiffraction spatial scales.  相似文献   

20.
The interactions of several affinity reagent displayed T7 and M13 phage particles with their corresponding target molecules were examined using Fluorescence Correlation Spectroscopy (FCS). Diffusion times, relative fractions of each component in the recognition reactions at the equilibrium state, and ultimately the dissociation constants were deduced from analyzing the fluorescence autocorrelation curves. Although the sample preparation and FCS characterization of icosahedral T7-related systems were relatively straight forward, procedures with filamentous M13-related systems were complicated by the physical size of M13 and its aggregate formation. Methods that accommodate the FCS measurement of the M13 phage via changing confocal optics, fitting procedures, and aggregate discrimination are presented and discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号