首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A rough bone implant surface was conceptualized as being built up of pits of different sizes and of different shapes. Hypotheses were formulated regarding the mechanical strength of the interfacial bone based upon the present knowledge of the character of the tissues adjacent to endosseous implants and the mechanical characteristics of different bone constituents. A surface roughness parameter was derived, the pit effectivity factor (fpe), which describes how effective the individual pits of the rough surface are as retention elements with regard to shear. Another surface roughness parameter was defined, the pit density factor (fpd), the value of which depends upon how densely packed the pits are. The interfacial shear strength of a rough implant surface with known microgeometry can be estimated by means of these two surface roughness parameters. The effectiveness of pits of different sizes and of different shapes was investigated using this model.  相似文献   

2.
The osseointegration of titanium dental implants is a complex process and there is a need for systematization of the factors influencing anchoring of implant. A common way of analyzing the strength of the fixation in bone is by measuring the torque required to remove the implants after healing. In this paper, a global biomechanical model is introduced and derived for removal torque situations. In this model, a gap is allowed to form between the bone and the implant and the size of the gap at fracture is a function of the surface roughness and can be shown to be directly related to the mean slope of the surface. The interfacial shear strength increases almost linearly with the mean slope and was also found to increase with an increase in the 2D surface roughness parameter, R(a). Besides the surface roughness, the design of the implant, the bone anatomy and the bone quality were shown to influence the interfacial shear strength. The Global biomechanical model can be used as a tool for optimizing the implant design and the surface topography to obtain high anchoring strength.  相似文献   

3.
In this paper the variation of normal and shear stresses along a path defined on the bone–dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibular incisor and the surrounding bone. The bone and the implant are assumed to be perfectly bonded. The finite element method with 2D plane strain assumption is used to compute interfacial stresses. Highest continuous interfacial stresses are encountered in the region where the implant collar engages the cortical region, and near the apex of the implant in the subcortical region. Stress concentrations in the interfacial stresses occur near the geometric discontinuities on the implant contour, and jumps in stress values occur where the elastic modulus of the bone transitions between the cortical and trabecular bone values. Among the six contour parameters, the slope and the length of the implant collar, and the implant diameter influence the interfacial stress levels the most, and the effects of changing these parameters are significantly noticed only in the cortical bone (alveolar ridge) area. External threads cause significant stress concentrations in interfacial stresses in otherwise smoothly varying regions. This work shows that the presence of external threads could cause significant variations in both normal and shear stresses along the bone–implant interface, but not reduction in shear stress as previously thought.  相似文献   

4.
A rotating disk shear device was used to study the effect of interfacial shear on the structural integrity of human monoclonal antibodies of IgG4 isotype. Factors associated with the solution conditions (pH, ionic strength, surfactant concentration, temperature) and the interface (surface roughness) were studied for their effect on the rate of IgG4 monomer loss under high shear conditions. The structural integrity of the IgG4 was probed after exposure to interfacial shear effects by SDS‐PAGE, IEF, dynamic light scattering, and peptide mapping by LC‐MS. This analysis revealed that the main denaturation pathway of IgG4 exposed to these effects was the formation of large insoluble aggregates. Soluble aggregation, breakdown in primary structure, and chemical modifications were not detected. The dominant factors found to affect the rate of IgG4 monomer loss under interfacial shear conditions were found to be pH and the nanometer‐scale surface roughness associated with the solid‐liquid interface. Interestingly, temperature was not found to be a significant factor in the range tested (15–45°C). The addition of surfactant was found to have a significant stabilizing effect at concentrations up to 0.02% (w/v). Implications of these findings for the bioprocessing of this class of therapeutic protein are briefly discussed. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

5.
The effect of implant-bone bonding and the effect of implant surface roughness on bone remodeling near the bone-implant interface were studied by using a surface remodeling theory and the boundary element method. The study has shown that implant attachment plays an important role in bone remodeling near the implant. It has been observed in animal experiments and in clinical situations that the remodeled trabecular bone architecture around a cylindrical implant could vary, on one hand, from a hub surrounding the implant with a set of external spokes to, on the other hand, a hubless situation in which a set of spokes attach directly to the implant. It is shown here that the difference in these structures may be attributed to differences in implant attachment. The results show that the bone with perfect bonding or roller boundary condition without a gap remodeled to a hubless spoke trabecular bone architecture. On the other hand, the roller boundary condition with a specified gap yielded a spoke trabecular architecture with a hub or ring surrounding the implant. These quantitative results mirror the experimental and clinical observations. It is concluded that the hub is a consequence of the gap and not a consequence of the lack of friction between the implant and the bone.  相似文献   

6.
Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved.  相似文献   

7.
The determining factors for the fixation of uncemented screws in bone are the bone-implant interface and the peri-implant bone. The goal of this work was to explore the role of the peri-implant bone architecture on the mechanics of the bone-implant system. In particular, the specific aims of the study were to investigate: (i) the impact of the different architectural parameters, (ii) the effects of disorder, and (iii) the deformations in the peri-implant region. A three-dimensional beam lattice model to describe trabecular bone was developed. Various microstructural features of the lattice were varied in a systematic way. Implant pull-out tests were simulated, and the stiffness and strength of the bone-implant system were computed. The results indicated that the strongest decrease in pull-out strength was obtained by trabecular thinning, whereas pull-out stiffness was mostly affected by trabecular removal. These findings could be explained by investigating the peri-implant deformation field. For small implant displacements, a large amount of trabeculae in the peri-implant region were involved in the load transfer from implant to bone. Therefore, trabecular removal in this region had a strong negative effect on pull-out stiffness. Conversely, at higher displacements, deformations mainly localized in the trabeculae in contact with the implant; hence, thinning those trabeculae produced the strongest decrease in the strength of the system. Although idealized, the current approach is helpful for a mechanical understanding of the role played by peri-implant bone.  相似文献   

8.
In the present study, a probabilistic finite element tool was assessed using an uncemented total hip replacement model. Fully bonded and frictional interfaces were investigated for combinations of three proximal femurs and two implant designs, the Proxima short stem and the IPS hip stem prostheses. The Monte Carlo method was used with two performance indicators: the percentage of bone volume that exceeded specified strain limits and the maximum nodal micromotion. The six degrees of freedom of bone-implant relative position, magnitude of the hip contact force (L), and spatial direction of L were the random variables. The distal portion of the proximal femurs was completely constrained and some of the main muscle forces acting in the hip were applied. The coefficients of the linear approximation between the random variables and the output were used as the sensitivity values. In all cases, bone-implant position related parameters were the most sensitive parameters. The results varied depending on the femur, the implant design and the interface conditions. Values of maximum nodal micromotion agreed with results from previous studies, confirming the robustness of the implemented computational tool. It was demonstrated that results from a single model study should not be generalised to the entire population of femurs and that bone variability is an important factor that should be investigated in such analyses.  相似文献   

9.
The surface state of titanium implants modulates bone response and implant anchorage. This evidence brought implant manufacturers to switch from the standard surface refinements and implement new surface treatments for more bone apposition and enhanced interfacial strength measured by removal torque or push-out tests. Anodic plasma-chemical treatment of implant surfaces is a cost-effective process to modify surface topography and chemistry. This technique is used for structuring connected with a coating of implant surfaces. The aim of our investigations, here, is to texture the implant surface in the nanoscale without coating. Ti disks with different mechanical pre-treatment (grinded, glass blasted) were used as substrate. Micro-plasma texturing was carried out in an aqueous electrolyte. By applying a pulsed DC voltage to the specimen, micro-plasma discharge was generated in the thin steam film between immersed specimen and electrolyte. The electrical process parameter current density was varied. The micro-plasma textured Ti surfaces were characterised optically by SEM and electrochemically by CV- (for testing the corrosion parameters), CA- (to give the enlargement of the real surface) and EIS-measurement in range of 100 kHz-100 microHz. We found that the initial structure of the material surface has small or no influence on the results of the micro-plasma treatment. The properties of the thick oxide layer resulting from the plasma process are influenced by electrical process parameters. After removal of the thick oxide layer a fine, micro- and nanoscaled surface structure of the titanium remains.  相似文献   

10.
Osseointegration of implant provides a stable support for the prosthesis under functional loads. The timing of loading is a critical parameter that can govern the success of the osseointegration of implant. However, it is not clear whether the early loading can affect the success of osseointegration, or whether the no-loading healing period can be shortened. This paper presents an animal study conducted to investigate how external loads influence the osseointegration at the initial stage of healing. Titanium implants were inserted into the goat tibia laterally, and different axial loadings were applied to the implants in 4 weeks after surgery. After the 2 weeks period of early loading, animals were sacrificed and the tibia bones with the implants were cut off from the bodies. Then mechanical test was employed to find out the differences in the pull-out force, and shear strength at the bone-implant interface between the non-loaded and the loaded implants. The implant-bone interfaces were analyzed by histomorphometric method, SEM (scanning electron micrograph) and EDS (energy density spectrum). The results indicated that the bone-implant interface did not well integrate 4 weeks after surgery, and the fibrous tissue could be found at the interfaces of the specimens without loadings. While the results of loaded specimens with 10 N axial force showed that that parts of the interface were well integrated, indicating that the early mild loading may play a positive role in the process of the osseointegration. The results support that a certain range of external loading would influence the process of osseointegration, and appropriate mechanical loading can be applied to shorten the osseointegration period after surgery. Supported by the National Natural Science Foundation of China (Grant Nos. 30370376, 10529202 and 10672015).  相似文献   

11.
In order to show that surface area is not always a quantity proportional to the surface roughness, we have constructed simple surfaces consisting of boxes of the same height equally spaced, and rms roughness and surface area have been computed. We have shown how we can get examples of surface configurations for which an increment in the surface roughness corresponds to a decrease in the surface area, although this is observed only for surfaces having similar rms roughness. We have also shown that even in the more intuitive situations where an increase in the surface roughness leads to an increase in the surface area, this increase is not necessarily equivalent. Analogous conclusions have been found when roughness was evaluated through the average roughness. These results could be interesting when analyzing interfacial phenomena such as cell adhesion, especially from a microscopic point of view, where the exact contact area between interacting phases governs these phenomena, and an exact-as-possible approximation to its real value is desirable. Also, the results of this paper could be of interest in various biomedical applications where the modulation of material surface-by-surface roughness may play a significant role. It can be concluded that care should be taken when using roughness parameters as estimators or indicators of the contact area between phases, since the relationship is not always simple.  相似文献   

12.
In this paper, linkages between tablet surface roughness, tablet compression forces, material properties, and the tensile strength of tablets were studied. Pure sodium halides (NaF, NaBr, NaCl, and NaI) were chosen as model substances because of their simple and similar structure. Based on the data available in the literature and our own measurements, various models were made to predict the tensile strength of the tablets. It appeared that only three parameters—surface roughness, upper punch force, and the true density of material—were needed to predict the tensile strength of a tablet. Rather surprising was that the surface roughness alone was capable in the prediction. The used new 3D imaging method (Flash sizer) was roughly a thousand times quicker in determining tablet surface roughness than traditionally used laser profilometer. Both methods gave practically analogous results. It is finally suggested that the rapid 3D imaging can be a potential in-line PAT tool to predict mechanical properties of tablets in production.  相似文献   

13.
Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to characterize and quantify micromotion-induced fluid flow around a cementless femoral stem using finite element modeling. With a 2D model of the bone-implant interface and full-factorial design, we first evaluated the relative influence of material properties, and bone-implant micromotion and gap on fluid velocity. Transverse sections around a femoral stem were built from computed tomography images, while boundary conditions were obtained from experimental measurements on the same femur. In a second step, a 3D model was built from the same data-set to estimate the shear stress experienced by cells hosted in the peri-implant tissues. The full-factorial design analysis showed that local micromotion had the most influence on peak fluid velocity at the interface. Remarkable variations in fluid velocity were observed in the macrostructures at the surface of the implant in the 2D transverse sections of the stem. The 3D model predicted peak fluid velocities extending up to 2.2 mm/s in the granulation tissue and to 3.9 mm/s in the trabecular bone. Peak shear stresses on the cells hosted in these tissues ranged from 0.1 to 12.5 Pa. These results offer insight into mechanical stimuli encountered at the bone-implant interface.  相似文献   

14.
Aseptic loosening at the implant-cement interface is a well-documented cause of failure in joint arthroplasty. Traditionally, the strength of the implant-cement interface is determined using uni-axial normal and shear loading tests. However, during functional loading, the implant fixation sites are loaded under more complex stress conditions. For this purpose, the strength of the implant-cement interface under mixed-mode tensile and shear loading conditions was determined in this study using interface specimens with varying interface roughness. For the lowest roughness value analyzed (R(a)=0.89 μm), the interface strength was 0.40-1.95 MPa at loading angles varying between pure tension and shear, whereas this was 4.90-9.90 MPa for the highest roughness value (R(a)=2.76 μm). The interface strength during pure shear (1.95-9.90 MPa) was substantially higher than during pure tension (0.58-6.67 MPa). Polynomial regression was used to fit a second-order interpolation function through the experimental interface strength data (R2=0.85; p<0.001), relating the interface strength (S [MPa]) to the interface loading angle (α [degrees]) and interface roughness (R(a) [μm]): S(α,R(a))=0.891R2(a)+0.001α2-0.189R(a)-0.064α-0.060. Finally, an interface failure criterion was derived from the interface strength measurements, describing the risk of failure at the implant-cement interface when subjected to a certain tensile and shear stress using only the interface strength in pure tensile and shear direction. The findings presented in this paper can be used in numerical models to simulate loosening at the implant-cement interface.  相似文献   

15.
Heat treatment is often used to improve the dimensional stability of wood. In this study, the effects of heat treatment on physical properties and surface roughness of Camiyani Black Pine (Pinus nigra Arn. subsp. pallasiana var. pallasiana) wood were examined. Samples obtained from Yenice-Zonguldak Forest Enterprises, Turkey, were subjected to heat treatment at varying temperatures and for varying durations. The physical properties of heat-treated and control samples were tested, and oven-dry density, air-dry density, and swelling properties were determined. The mechanical properties of heat-treated and control samples were tested, and compression strength, and Janka-hardness were determined. A stylus method was employed to evaluate the surface characteristics of the samples. Roughness measurements by the stylus method were made in the direction perpendicular to the fiber. Four main roughness parameters, mean arithmetic deviation of profile (Ra), mean peak-to-valley height (Rz), root mean square roughness (Rq), and maximum roughness (Ry) obtained from the surface of wood were used to evaluate the effect of heat treatment on the surface characteristics of the specimens. Significant difference was determined (p=0.05) between physical and technological properties, and surface roughness parameters (Ra, Rz, Ry, Rq) for three temperatures and three durations of heat treatment. Based on the findings in this study, the results showed that density, swelling, compression strength, Janka-hardness and surface roughness values decreased with increasing treatment temperature and treatment times. Increase in temperature and duration further diminished technological strength values of the wood specimens. Camiyani Black Pine wood could be utilized by using proper heat treatment techniques without any losses in strength values in areas where working, stability, and surface smoothness, such as in window frames, are important factors.  相似文献   

16.
Factors related to micromovements at bone-implant interface have been studied because they are considered adverse to osseointegration. Simplifications are commonly observed in these FEA evaluations. The aim of this study was to clarify the influence of FEA parameters (boundary conditions and bone properties) on the stress distribution in peri-implant bone tissue when micromovements are simulated in implants with different geometries. Three-dimensional models of an anterior section of the jaw with cylindrical or conical titanium implants (4.1 mm in width and 11 mm in length) were created. Micromovement (50, 150, or 250 μm) was applied to the implant. The FEA parameters studied were linear vs. non-linear analyses, isotropic vs. orthogonal anisotropic bone, friction coefficient (0.3) vs. frictionless bone-implant contact. Data from von Mises, shear, maximum, and minimum principal stresses in the peri-implant bone tissue were compared. Linear analyses presented a relevant increase of the stress values, regardless of the bone properties. Frictionless contact reduced the stress values in non-linear analysis. Isotropic bone presented lower stress than orthogonal anisotropic. Conical implants behave better, in regard to compressive stresses (minimum principal), than cylindrical ones, except for nonlinear analyses when micromovement of 150 and 250 μm were simulated. The stress values raised as the micromovement amplitude increased. Non-linear analysis, presence of frictional contact and orthogonal anisotropic bone, evaluated through maximum and minimum principal stress should be used as FEA parameters for implant-micromovement studies.  相似文献   

17.
Press-fitting is used to anchor uncemented implants in bone. It relies in part on friction resistance to relative motion at the implant–bone interface to allow bone ingrowth and long-term stability. Frictional shear capacity is related to the interference fit of the implant and the roughness of its surface. It was hypothesised here that a rough implant could generate trabecular bone damage during implantation, which would reduce its stability. A device was constructed to simulate implantation by displacement of angled platens with varying surface finishes (polished, beaded and flaked) onto the surface of an embedded trabecular bone cube, to different nominal interferences. Push-in (implantation) and Pull-out forces were measured and micro-CT scans were made before and after testing to assess permanent bone deformation. Depth of permanent trabecular bone deformation (‘damage’), Pull-out force and Radial force all increased with implantation displacement and with implantation force, for all surface roughnesses. The proposed hypothesis was rejected, since primary stability did not decrease with trabecular bone damage. In fact, Pull-out force linearly increased with push-in force, independently of trabecular bone damage or implant surface. This similar behaviour for the different surfaces might be explained by the compaction of bone into the surfaces during push-in so that Pull-out resistance is governed by bone-on-bone, rather than implant surface-on-bone friction. The data suggest that maximum stability is achieved for the maximum implantation force possible (regardless of trabecular bone damage or surface roughness), but this must be limited to prevent periprosthetic cortical bone fracture, patient damage and component malpositioning.  相似文献   

18.
The interfacial strength of secondary osteons from the diaphysis of the Thoroughbred equine third metacarpal was evaluated using the fiber pushout test. The pushout was performed on 300-500 microm sections of 4x4x15 mm bone blocks machined from four anatomic regions of the cortex. Pushout strength was evaluated from proximal to distal location within the diaphysis on four osteon types classified under polarized light on adjacent histologic sections from each block. The shear strength of the interfaces were estimated from shear lag theory. Differences were found in the interfacial strength of osteons based on appearance under polarized light with bright field having the highest interfacial strength (40.3 MPa). The lowest strength was found in the dark field osteons (22.8 MPa). The dorsal region had the highest shear strength and toughness compared to all other regions. The cement line and interlamellar interfaces are similar in strength, but exhibit regional dependence--specifically, the palmar region strength is less (17.5 MPa) than the osteon interlamellar interfaces (30.4 MPa) and osteon type dependent (alternating significantly weaker than other types). Histomorphometry revealed significant regional differences (p<0.0001) in osteon area fraction among the four osteon types as well as differences in the osteon diameter (p=0.01), with dorsal regions having larger osteons (170 microm) than the palmar region (151 microm). Fatigue life and fracture toughness of Haversian bone are reported in the literature to be regionally dependent and are known to be associated with osteon pullout--an osteon interfacial phenomenon. Therefore, the results presented in this study are important to further the understanding of the mechanisms of fragility and damage accumulation in cortical bone.  相似文献   

19.
Sun Y  Guo S  Walker GC  Kavanagh CJ  Swain GW 《Biofouling》2004,20(6):279-289
The properties of barnacle adhesive on silicone surfaces were studied by AFM indentation, imaging, and other tests and compared to the barnacle shear adhesion strength. A multilayered structure of barnacle adhesive plaque is proposed based on layered modulus regions measured by AFM indentation. The fracture of barnacles from PDMS surfaces was found to include both interfacial and cohesive failure of barnacle adhesive plaque, as determined by protein staining of the substratum after forced barnacle release from the substrate. Data for freshly released barnacles showed that there was a strong correlation between the mean Young's modulus of the outermost (softest) adhesive layer (E<0.3 MPa) and the shear strength of adhesion, but no correlation for other higher modulus regions. Linear, quadratic, and Griffith's failure criterion (based on rough estimate of crack length) regressions were used in the fit, and showed significance.  相似文献   

20.
Dental implantology has high success rates, and a suitable estimation of how stresses are transferred to the surrounding bone sheds insight into the correct design of implant features. In this study, we estimate stress transfer properties of four commercial implants (GMI, Lifecore, Intri and Avinent) that differ significantly in macroscopic geometry. Detailed three-dimensional finite element models were adopted to analyse the behaviour of the bone-implant system depending on the geometry of the implant (two different diameters) and the bone-implant interface condition. Occlusal static forces were applied and their effects on the bone, implant and bone-implant interface were evaluated. Large diameters avoided overload-induced bone resorption. Higher stresses were obtained with a debonded bone-implant interface. Relative micromotions at the bone-implant interface were within the limits required to achieve a good osseointegration. We anticipate that the methodology proposed may be a useful tool for a quantitative and qualitative comparison between different commercial dental implants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号