首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation threshold (DFT) testing with 65 Jcaused a forceful pectoralis twitch. The patient woke up with a painful anteriorly dislocated left shoulder. Glenohumeral dislocation due to DFT testing has not been previously reported. It is likely that this complication is specific to the S-ICD implantation, and is related to positioning with the arm abducted, externally rotated, and immobilized, and use of greater defibrillation energy with current pathway through the bulk of the pectoralis muscle.Precautions may include extending the arm palm down, strapping the arm loosely, and adduction of the arm for DFT testing.  相似文献   

2.

Introduction

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetically transmitted disease prone to ventricular arrhythmias. We therefore investigated the clinical, echocardiographical and electrophysiological predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in patients with ARVC.

Methods

A retrospective analysis was performed in 26 patients (median age of 40 years at diagnosis, 21 males and 5 females) with ARVC who underwent ICD implantation.

Results

Over a median (range) follow-up period of 10 (2.7, 37) years, appropriate ICD therapy for ventricular arrhythmias was documented in 12 (46%) out of 26 patients. In all patients with appropriate ICD therapy the ICD was originally inserted for secondary prevention. Median time from ICD implantation to ICD therapy was 9 months (range 3.6, 54 months). History of heart failure was a significant predictor of appropriate ICD therapy (p = 0.033). Left ventricular disease involvement (p = 0.059) and age at implantation (p = 0.063) were borderline significant predictors. Patients with syncope at time of diagnosis were significantly less likely to receive ICD therapy (p = 0.02). Invasive electrophysiological testing was not significantly associated with appropriate ICD therapy.

Conclusion

In our cohort of patients with ARVC, history of heart failure was a significant predictor of appropriate ICD therapy, whereas left ventricular involvement and age at time of ICD implantation were of borderline significance. These predictors should be tested in larger prospective cohorts to optimize ICD therapy in this rare cardiomyopathy.  相似文献   

3.
All procedures have inherent risk. Our patient endured a sequence of rare life-threatening complications from commonly preformed procedures. The sequence of these complications was; large pericardial effusion post implantable cardioverter-defibrillator (ICD) implantation with echocardiographic signs of tamponade, left main narrowing post radiofrequency ablation, and late stent thrombosis post coronary intervention with a bare metal stent. All these occurred to one unfortunate young man. Furthermore, our patient demonstrated an unintended benefit of ICD which saved his life.  相似文献   

4.
Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant’s view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70–80 Hz vibration to the elbow flexors of the reference arm (= right arm) to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.  相似文献   

5.
The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three patients who were treated with a WCD in an outpatient setting. The WCD allowed the cardiac condition of two patients to improve to such an extent that permanent ICD implantation was deemed unnecessary. This new form of therapy may result in significant cost reduction, avoidance of unnecessary ICD implantation, and increased patient satisfaction.  相似文献   

6.

Purpose

Based on multiple large clinical trials conducted over the last decades guidelines for implantable cardioverter-defibrillator (ICD) implantations have been evolving. The increase in primary prophylactic ICD implantations challenges us to be critical towards the indications in certain patient populations.

Methods

We retrospectively collected patient characteristics and rates of appropriate and inappropriate ICD therapy, appropriate and inappropriate ICD shock and mortality of all patients who received an ICD in the University Medical Center Utrecht (UMCU) over the years 2006–2011.

Results

A total of 1075 patients were included in this analysis (74 % male, mean age 61 ± 13 years, left ventricular ejection fraction 30 ± 13 %); 61 % had a primary indication and 58 % had ischaemic heart disease. During a mean follow-up period of 31 ± 17 months, 227 of the patients (21 %) received appropriate ICD therapy (149 (14 %) patients received an appropriate ICD shock). Females, patients with a primary prophylactic indication and patients with non-ischaemic heart disease experienced significantly less ICD therapy. Only a few patients (54, 5 %) received inappropriate ICD therapy; 33 (3 %) patients received an inappropriate ICD shock. Fifty-five patients died within one year after ICD implantation and were therefore, in retrospect, not eligible for ICD implantation.

Conclusion

Our study confirms the benefit of ICD implantation in clinical practice. Nevertheless, certain patients experience less benefit than others. A more patient-tailored risk stratification based on electrophysiological parameters would be lucrative to improve clinical benefit and cost-effectiveness.  相似文献   

7.
A woman who had a deep scar on her left arm as a result of an influenza vaccination was treated with insulin. Monocomponent porcine insulin was injected into each quadrant of the pit. After 82 days'' treatment her arm appeared normal and has remained so over seven months. Using insulin''s ability to promote fat and protein synthesis is a simple and effective way of treating atrophied scars.  相似文献   

8.
Sudden cardiac death (SCD) due to various cardiomyopathies is currently prevented by the implantation of an automated cardioverter/defibrillator (ICD). ICD impalntation in patients who are not survivors of SCD, or have not suffered potentially lethal ventricular arrhythmias, are based on the presence of cardiomyopathy with a reduced left ventricular ejection fraction. The bulk of patients who are considered suitable for an ICD implantation and receive such devices, do not experience device therapy shocks at follow-up ("false positives"), thus creating a climate of uncertainty among patients and physicians about the soundness of our current eligibility criteria for ICDs. In addition the cost of inappropriate ICDs is staggering, and the undue exposure of "false positive" patients to complications, and hardships is disconcerting. T-wave alternans (TWA) has emerged as a possible "risk detection of SCD" technology, but its reproducibility has not been tested. Peripheral edema (extracardiac) or other cardiac mechanisms, unrelated to the degree of SCD risk, alter the amplitude, and other attributes, of the T-waves. Since TWA may be T-wave amplitude-, or other T-wave attributes-dependent (this is still a speculation), a need may be emerging for its correction by the T-wave amplitude (TWA index); such an index may enhance the reproducibility, and evaluate the true sensitivity, specificity and predictive accuracy of the TWA in detecting future victims of SCD.  相似文献   

9.
10.
ABSTRACT: BACKGROUND: Coronary artery disease (CAD) is associated with an increased risk for sudden cardiac death. Randomized controlled trials have shown that implantable cardioverter defibrillators (ICD) improve life expectancy unless they are implanted within the first days after an acute myocardial infarction and guidelines recommend their use. We aimed to validate that these results also apply to patients of a typical community hospital in Germany. METHODS: This was a retrospective analysis of patients undergoing coronary angiography in the Lippe-Detmold Hospital between 2003 and 2006. They had to have significant CAD and an ejection fraction (EF) [less than or equal to] 35% and no acute myocardial infarction within 28 days of implantation and no history of ventricular fibrillation. RESULTS: 213 patients were included; 70 of which received an ICD. Patients with an ICD implantation were younger (64.8+/-9.9 vs. 67.9+/-9.8 years; p=0.034), had single vessel CAD more frequently (22.9 vs. 11.2%; p=0.025) and a lower EF (26.7+/-6.3 vs. 29.1+/-4.6%; p=0.006). Hospital readmissions were comparable between the ICD and the control group (68.6 vs. 72.0%; p=0.602). ICD therapy was associated with a considerable survival benefit compared to conventional therapy (HR 0.52; 95%CI 0.29-0.93; p=0.027) in a Cox-Proportional Hazards Regression analysis. CONCLUSIONS: Appreciating the potential limitations of retrospective studies, we found that ICD use was associated with improved survival in patients with significant CAD and an EF 35%, typical for a large tertiary hospital.  相似文献   

11.
In the last two decades, the focus of implantable cardioverter defibrillator {ICD} trials has mainly been on prophylactic implantation of ICDs in high-risk populations for the prevention of sudden cardiac death. In particular, prophylactic ICDs in high-risk post-MI patients with a depressed left ventricular ejection fraction has resulted in significantly improved survival. These benefits are in addition to those of optimal pharmacological therapy and ICD therapy should be considered the standard of care in these patients.  相似文献   

12.
Background/PurposeTransarterial lead implantation in the left ventricle or aorta is a rare complication. Percutaneous lead removal is associated with significant thromboembolic and bleeding risk. We present two cases of lead removal from the left ventricle via the left subclavian artery with concurrent carotid embolic protection followed by stent graft placement in the subclavian artery.Methods/ResultsPatient 1 underwent prior pacemaker implant with atrial and ventricular active fixation leads positioned in the right coronary cusp and the left ventricle, respectively. Patient 2 had prior ICD implant with a single active fixation lead positioned in the left ventricular apex. Lead removal was performed in a hybrid operating room. Distal embolic filter wires were deployed in the carotid arteries following anticoagulation. Intravascular ultrasound of the left subclavian artery was performed and as the leads were withdrawn, a covered stent was deployed at the removal site. Final angiography demonstrated no evidence of embolic phenomena. Both patients underwent transvenous lead implantation followed by an uneventful postoperative clinical course.ConclusionsTransarterial percutaneous lead removal may be safely performed using embolic filter protection of the cerebral circulation and stent graft placement of the arterial entry site.  相似文献   

13.
Subcutaneous hematoma is a complication of cardiac device implantation. In most cases, it is drained or spontaneously reabsorbed. While cases of chylothorax are rare, and cases of pseudochylothorax even rarer, previous cases of accumulation of chyliform material in the subcutaneous pockets of cardiac devices are anecdotal. We present a case of a 60-year-old man with antiphospholipids antibody syndrome and rheumatoid arthritis, who underwent dual-chamber ICD implantation in December 2020; the procedure was complicated by a pocket hematoma, which required surgical drainage. After 7 months, the man returned owing to heart failure, with evidence of the reappearance of a large swelling in the ICD pocket; this was tolerated for months by the patient and was no longer controlled. We drained 100ml of gold-colored, odorless liquid, and found no evidence of blood material in the pocket. The liquid was not pus, as culture testing proved negative for bacterial growth. Chemical-physical examination revealed elevated cholesterol concentration (704 mg/dl) and low levels of triglycerides (80 mg/dl; plasma cholesterol values were 91mg/dl, and triglycerides 48 mg/dl). Microscopic examination revealed isolated leukocytes and rare erythrocytes immersed in mucoid material; cytological analysis showed a carpet of macrophages filled with cholesterol. This evidence supports the diagnosis of pseudochyle fluid, formed by the degradation of a hematoma left intact in a closed cavity for more than 6 months. This is an extremely rare case of chyliform fluid documented in an ICD pocket.  相似文献   

14.
A 24-year-old male with Wolff-Parkinson-White syndrome developed systolic cardiomyopathy and severe heart failure following membranous ventricular septal defect repair and tricuspid valve replacement. Following successful catheter ablation of a right anterolateral accessory pathway (AP), complete AV block with junctional escape rhythm was noted. Patient subsequently underwent implantation of a biventricular ICD. Heart failure symptoms significantly improved soon after and left ventricular systolic function normalized 3 months post-procedure. In this case, surgically acquired AV block likely explains development of postoperative cardiomyopathy by facilitating ventricular activation solely via the AP and thereby increasing the degree of ventricular dyssynchrony.  相似文献   

15.
At first sight, guidelines for implantation of an implantable cardioverter defibrillator (ICD) for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction seem unambiguous. There are clear cut-off values for ejection fraction, and functional class. However, determination of the ejection fraction itself is not unambiguous, and other risk factors for sudden death that may have a profound effect on risk are not used for decision-making. Furthermore, to obtain a clinically significant impact on survival, expected longevity is important as it can greatly compromise the benefit in elderly patients but underestimate the long-term potential of ICD therapy in younger patients. (Neth Heart J 2009; 17:107–10.)  相似文献   

16.

Background

Fragmented QRS (fQRS) has been shown to be a marker of local myocardial conduction abnormalities and a predictor of cardiac events in selected populations. We hypothesized that the presence of a fQRS might predict arrhythmic events in patients who received an implantable cardioverter-defibrillator (ICD), regardless of the indications for implantation.

Methods and Results

A cohort of 107 consecutive patients (mean age, 53 years; 82% male) who underwent an ICD implantation was studied. We defined fQRS, on a routine 12-lead ECG, as the presence of an additional R wave or notching in the nadir of the S wave in 2 consecutive leads corresponding to a major coronary artery territory. In the presence of bundle branch block, more than 2 notches in the R or S waves in 2 consecutive leads were required to characterize fQRS. Patients were followed for 21.3±23 months for appropriate ICD therapy (antitachycardia pacing and/or shock). ICDs were implanted predominantly in patients with ischemic cardiomyopathy (N=45, 42.1%), followed by Brugada syndrome (N=26, 24.3%). fQRS presented in 42 patients (39.3%). During follow-up, patients with fQRS received more appropriate ICD therapy than those without fQRS (45.2% vs. 10.8%, P<0.0001). After adjustment for covariates, fQRS remained an independent predictor for appropriate ICD therapy (hazard ratio=5.32, 95% confidence interval=2.11-13.37, P<0.0001).

Conclusion

The presence of fQRS appeared to be directly associated with appropriate ICD therapy.  相似文献   

17.
Dextrocardia is a congenital anomaly where the heart is abnormally located in the right hemithorax. In these patients, the implementation of transvenous implantable cardioverter-defibrillator (TV-ICD) can be technically challenging and pose a higher risk of complications than the general population. We present the case of a male patient that was successfully submitted to right-sided implantation of subcutaneous ICD (S-ICD) as an alternative to transvenous ICD (TV-ICD) for primary prevention of sudden cardiac death. This option is not only feasible but may potentially be ideal for these patients, as it circumvents challenges and potential complications of TV-ICD insertion.  相似文献   

18.
Hypertrophic cardiomyopathy’s (HCM) association with sudden cardiac death is well recognised. The risk of sudden cardiac death is known to increase when there is a history of unexplained syncope, abnormal blood pressure response during exercise, severe left ventricular hypertrophy or a family history of unexplained death.Implantable Cardioverter Defibrillator (ICD) implantation has been widely used for primary and secondary prevention of sudden cardiac death (SCD) in people with HCM. Subcutaneous ICD (S-ICD) therapy has been developed to overcome some of the problems associated with the transvenous leads used in conventional ICDs.In this article, we report the use of S-ICD in a patient with HCM and multiple risk factors for sudden cardiac death, this device had to be extracted due to recurrent inappropriate shocks caused by over sensing of atrial flutter and failure to treat a VT episode. We are not aware of any reports of inappropriate shocks caused by atrial flutter in people with a S-ICD.  相似文献   

19.
BackgroundThe wearable cardioverter-defibrillator (WCD) has been approved for patients with poor left ventricular ejection fraction (LVEF) who are at risk of sudden arrhythmic death for a limited period but are not candidates for a definitive implantable cardioverter-defibrillator (ICD). The present study sought to retrospectively analyse our single-centre experience.Methods and resultsAll consecutive WCDs applied between April 2017 and September 2018 in our centre were enrolled. An exercise test was performed in all patients in order to evaluate the absence of false detection of ventricular arrhythmias by the device. A total of 16 patients (57.7 ± 14.8 years old; 75% males) were taken into consideration for the analysis. Mean LVEF was 32 ± 11% at diagnosis and 42 ± 10% at last follow-up (mean, 3.1 ± 1.7 months; median, 3 months). At the end of the “wearing period” 11/16 patients (69%) did not have ICD implant indications and only 5 (31%) underwent ICD implantation. Neither appropriate nor appropriate shocks occurred during the follow up.ConclusionsThe WCD represents a useful tool to bridge a temporarily increased risk for sudden cardiac death. The proportion of patients with an improvement of LVEF> 35% beyond the WCD-application period was considerable.  相似文献   

20.

Introduction

Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this study, we aimed to evaluate the predictive value of MTWA in ICD patients.

Methods and results

This study was a substudy of the Twente ICD Cohort Study (TICS). Patients with ischaemic or non-ischaemic left ventricular dysfunction who received an ICD following current ESC guidelines were eligible for inclusion. Exercise-MTWA was performed and classified as non-negative or negative. The primary endpoint was the composite of mortality and appropriate shock therapy. Analysis was performed in 134 patients (81 % male, mean age 62 years, mean ejection fraction 26.5 %). MTWA was non-negative in 64 %. There was no relation between non-negative MTWA testing and mortality and/or appropriate shock therapy (all p-values >0.15). Due to clinical conditions, 24 % were ineligible for testing. These patients experienced the highest risk for mortality (p < 0.01).

Conclusion

Non-negative MTWA testing did not predict mortality and/or appropriate shock therapy. Furthermore, MTWA testing is not feasible in a large percentage of patients. These ineligible patients experience the highest risk for mortality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号