Introduction

Treatment of femoral neck fractures in young adults may require total hip arthroplasty or hip hemiarthroplasty using a bipolar cup. The latter can, however, result in migration of the femoral head and poor long-term results.

Case presentation

We report a case of femoral head migration after hemiarthroplasty performed for femoral neck fracture that had occurred 22 years earlier, when the patient (a Japanese man) was 20 years old. He experienced peri-prosthetic fracture of the femur, subsequent migration of the prosthesis, and a massive bone defect of the pelvic side acetabular roof. After bone union of the femoral shaft fracture, the patient was referred to our hospital for reconstruction of the acetabular roof. Intra-operatively, we placed two alloimplants of bone from around the transplanted femoral head into the weight-bearing region of the acetabular roof using an impaction bone graft method. We then implanted an acetabular roof reinforcement plate and a cemented polyethylene cup in the position of the original acetabular cup. Eighteen months post-operatively, X-rays showed union of the transplanted bone.

Conclusions

Treatment of femoral neck fractures in young adults is usually accomplished by osteosynthesis, but it may be complicated by femoral head avascular necrosis or by infection or osteomyelitis. In such cases, once an infection has subsided, either hip hemiarthroplasty using a bipolar cup or total hip arthroplasty may be required. However, if the acetabular side articular cartilage is damaged, a bipolar cup should not be used. Total hip arthroplasty should be performed to prevent migration of the implant.  相似文献   

2.
Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.  相似文献   

3.
Prediction of lubricating film thickness in UHMWPE hip joint replacements   总被引:4,自引:0,他引:4  
An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.  相似文献   

4.
A computational model was developed to identify the sites of third body particle embedment in a total hip acetabular component surface that are most problematic in terms of roughening the overpassing regions of the femoral head counterface, leading in turn to most severely accelerated polyethylene wear. The analytical approach used was to calculate loci of acetabular sites that, during the gait cycle, overpass previously documented regions of kinetically most critical femoral head roughening. Instantaneous local contact stress and sliding distance were postulated as factors contributing to the severity of the femoral head scratching/roughening which would be expected, due to otherwise-similar particles embedded along each such acetabular overpass locus. The computational results showed that the location of debris embedment was a potent determinant of the amount of polyethylene wear acceleration expected. The data also showed that the supero-lateral aspect of the acetabular cup is consistently and by far the most problematic area for third body particle embedment.  相似文献   

5.
A new finite element model (FEM) based on an elasto-plastic behavior of ultra high molecular weight polyethylene (UHMWPE) was used to study the wear behavior of UHMWPE acetabular cup, which has a 32 mm diameter femoral head. The model imposed a plastic yield stress of 8 MPa on the UHMWPE so that any stresses beyond this would automatically be redistributed to its neighbor. The FEM model adopted a unique mesh design based on an open cube concept which eliminated the problems of singularities. Wear prediction combined the influences of contact stress, sliding distance and a surface wear coefficient. The new model predicted significantly higher volumetric wear rate (57 mm(3)/yr) well within the average reported clinical values. The model was also used to study the effect of friction and clearance between the acetabular cup and the femoral head. Increase in friction increased the volumetric wear rate but did not appear to affect the linear wear rate, which remained at 0.12 +/- 0.02 mm/yr. The predicted wear was sensitive to clearance. It was found that when the clearance was close to 0 and >0.5mm, severe wear occurred. The best clearance range was between 0.1 and 0.15 mm where the average linear wear rate was 0.1mm/yr and the volumetric wear was 55 mm(3)/yr. The present work indicates the importance of avoiding too tight or too loose a diametrical clearance.  相似文献   

6.
Numerous supporting structures assist in the retention of the femoral head within the acetabulum of the normal hip joint including the capsule, labrum, and ligament of the femoral head (LHF). During total hip arthroplasty (THA), the LHF is often disrupted or degenerative and is surgically removed. In addition, a portion of the remaining supporting structures is transected or resected to facilitate surgical exposure. The present study analyzes the effects of LHF absence and surgical dissection in THA patients. Twenty subjects (5 normal hip joints, 10 nonconstrained THA, and 5 constrained THA) were evaluated using fluoroscopy while performing active hip abduction. All THA subjects were considered clinically successful. Fluoroscopic videos of the normal hips were analyzed using digitization, while those with THA were assessed using a computerized interactive model-fitting technique. The distance between the femoral head and acetabulum was measured to determine if femoral head separation occurred. Error analysis revealed measurements to be accurate within 0.75mm. No separation was observed in normal hips or those subjects implanted with constrained THA, while all 10 (100%) with unconstrained THA demonstrated femoral head separation, averaging 3.3mm (range 1.9-5.2mm). This study has shown that separation of the prosthetic femoral head from the acetabular component can occur. The normal hip joint has surrounding capsuloligamentous structures and a ligament attaching the femoral head to the acetabulum. We hypothesize that these soft tissue supports create a passive, resistant force at the hip, preventing femoral head separation. The absence of these supporting structures after THA may allow increased hip joint forces, which may play a role in premature polyethylene wear or prosthetic loosening.  相似文献   

7.
The range of motion (ROM) of total hip prostheses is influenced by a number of parameters. An insufficient ROM may cause impingement, which may result in subluxation, dislocation or material failure of the prostheses. In a three-dimensional CAD simulation, the position of the centre of rotation and the CCD angle of the stem were investigated. Displacement of the centre of rotation of the femoral head may be due to wear (PE cups) or to the design of the prosthesis (ceramic cups). Stems of widely differing design have been developed and implanted. The results of the present study demonstrate that the ROM is clearly reduced by increasing penetration of the femoral head. At an inclination angle of 45 degrees, a depth of penetration of 2 mm restricts flexion by about 15 degrees, and a depth of penetration of 3 mm by about 30 degrees. At smaller angles of inclination the ROM is reduced and flexion and abduction are associated with an increased risk of impingement. With steeper acetabular cup inclinations, the risk of impingement decreases, but dislocation, the risk of rim fractures (ceramic cups), and wear and penetration rates (PE cups) increase. The CCD angle of the stem should be oriented to the anatomical situation. At high CCD angles (> 135 degrees), flexion is clearly limited, in particular when there is penetration of the femoral head. For modern total hip arthroplasty, prosthetic systems characterised by precise positioning of components, minimum wear, slightly recessed inserts, and appropriate CCD angles should be used.  相似文献   

8.
After total hip replacement (THR) impingement of the implant components causes shear stresses at the acetabular implant-bone interface. In the current study the finite element method (FEM) was applied to analyse the shear stresses at a fully bonded implant-bone interface assuming total ingrowth of the cup. The FE model of a press-fit acetabular component and the proximal part of the femoral component incorporates non-linear material and large sliding contact. The model was loaded with a superior-medial joint load of 435 N simulating a two-legged stance. Starting at initial impingement, the femoral component was medially rotated by 20 degrees . The peak tilting shear stress of -2.6 MPa at the impingement site takes effect towards the pole of the cup. The torsional shear stress at the impingement site is zero. On each side of the impingement site, there are extrema of torsional shear stress reaching -1.8 and 1.8 MPa, respectively. The global peak shear stress during impingement may indicate a possible starting point for cup loosening. The pattern of the torsional shear stresses suggests that besides the symmetric lever-out, an additional asymmetrical tilting of the cup occurs that can be explained by the orientation of the applied joint load.  相似文献   

9.
After total hip arthroplasty, impingement of implant components may occur during every-day patient activities causing increased shear stresses at the acetabular implant-bone interface. In the literature, impingement related lever-out moments were noted for a number of acetabular components. But there is little information about pelvic load transfer. The aim of the current study was to measure the three-dimensional strain distribution at the macrostructured hemispherical interface and in the periphery of a standard acetabular press-fit cup in an experimental implant-bone substitute model. An experimental setup was developed to simulate impingement loading via a lever arm representing the femoral component and the lower limb. In one experimental setup 12 strain gauges were embedded at predefined positions in the periphery of the acetabular cup implant inside a tray, using polyurethane composite resin as a bone substitute material. By incremental rotation of the implant tray in steps of 10 and 30 deg, respectively, the strains were measured at evenly distributed positions. With the described method 288 genuine strain values were measured in the periphery of an embedded acetabular cup implant in one experimental setup. In two additional setups the strains were evaluated at different distances from the implant interface. Both in radial and meridional interface directions strain magnitudes reach their peak near the rim of the cup below the impingement site. Values of equatorial strains vary near zero and reach their peaks near the rim of the cup on either side and in some distance from the impingement site. Interestingly, the maximum of averaged radial strains does not occur, as expected, close to the interface but at an interface offset of 5.6 mm. With the described experimental setup it is now possible to measure and display the three-dimensional strain distribution in the interface and the periphery of an embedded acetabular cup implant. The current study provides the first experimental proof of the high local stresses gradients in the direct vicinity of the impingement site. The results of the current study help for a better understanding of the impingement mechanism and its impact on acetabular cup stability.  相似文献   

10.
The present investigation focuses on total hip replacement using ceramic acetabular components. The relationship between the position of the cup and the range of motion (ROM) was investigated. A limited range of motion may cause impingement, which is defined as contact between the femoral neck and the rim of the acetabular cup. Impingement may result in wear, chipping, fracture or dislocation of the femoral head. Joint movements were simulated in a three-dimensional CAD program. The results obtained underscore the importance of correct positioning and design of the cup for achieving a ROM as close to the physiological situation as possible. With ceramic cups, the inclination angle should not be more than 45 degrees, and the antetorsion angle between 10 and 15 degrees. If the cup is too vertical, the risk of dislocation and fracture of the ceramic increases. If, on the other hand, the angle of inclination is too small, flexion and abduction will be greatly limited. The study shows that acetabular components with non-recessed ceramic inserts should not be used. Slight recession of the insert helps to avoid impingement. The ROM is reduced and the risk of impingement appreciably increased when mushroom-shaped femoral heads (XL heads) or ceramic inserts protected by a polyethylene ring are used.  相似文献   

11.

Background

Evolvements in the design, fixation methods, size, and bearing surface of implants for total hip replacement (THR) have led to a variety of options for healthcare professionals to consider. The need to determine the most optimal combinations of THR implant is warranted. This systematic review evaluated the clinical effectiveness of different types of THR used for the treatment of end stage arthritis of the hip.

Methods

A comprehensive literature search was undertaken in major health databases. Randomised controlled trials (RCTs) and systematic reviews published from 2008 onwards comparing different types of primary THR in patients with end stage arthritis of the hip were included.

Results

Fourteen RCTs and five systematic reviews were included. Patients experienced significant post-THR improvements in Harris Hip scores, but this did not differ between impact types. There was a reduced risk of implant dislocation after receiving a larger femoral head size (36 mm vs. 28 mm; RR = 0.17, 95% CI: 0.04, 0.78) or cemented cup (vs. cementless cup; pooled odds ratio: 0.34, 95% CI: 0.13, 0.89). Recipients of cross-linked vs. conventional polyethylene cup liners experienced reduced femoral head penetration and revision. There was no impact of femoral stem fixation and cup shell design on implant survival rates. Evidence on mortality and complications (aseptic loosening, femoral fracture) was inconclusive.

Conclusions

The majority of evidence was inconclusive due to poor reporting, missing data, or uncertainty in treatment estimates. The findings warrant cautious interpretation given the risk of bias (blinding, attrition), methodological limitations (small sample size, low event counts, short follow-up), and poor reporting. Long-term pragmatic RCTs are needed to allow for more definitive conclusions. Authors are encouraged to specify the minimal clinically important difference and power calculation for their primary outcome(s) as well CONSORT, PRISMA and STROBE guidelines to ensure better reporting and more reliable production and assessment of evidence.  相似文献   

12.
The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35–50° and 10–25°, respectively, and 12 cases with different hip centre heights within a range of 0–15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants.  相似文献   

13.
Retrieved ceramic femoral heads and acetabular cups were investigated. On the basis of the case studies, the reasons for revision are discussed. Wear patterns and wear rates were found to differ from those observed in hip simulating testing. Monolithic ceramic cups showed a high wear rate. Owing to their limited range of motion, ceramic "mushroom heads" are associated with impingement that leads to a high risk of cup loosening, high wear rates and in vivo fractures. The combination of ceramic "mushroom heads" and cups is not recommended. An evaluation of complications shows that some can be explained by patient behaviour--e.g. Japanese sitting position, horse riding. Designers need to develop new concepts offering a larger range of motion, for example, with head diameters of 32 and 36 mm that reduce the risk of impingement, subluxation and dislocation, while increasing the range of motion. The potential of ceramic/ceramic coupling has been known since the 70s, and ceramic concepts for total hip replacement are currently experiencing a renaissance, although further developments are still possible.  相似文献   

14.
A hip joint simulator was developed to analyse the mechanism of loosening of cementless artificial hip cups. The machine induces vibrating motions and asymmetrical tilt shock loadings of the artificial cup. On measuring the primary stability of threaded cups, the simulation tests performed on pelvis substitute models, and animal and human acetabula failed to show any loosening of threaded cups fixed in place with a screw-in torque of more than 10 Nm. Instable cups became loose all the sooner, the lower the preload between the cup and femoral head. This demonstrates the importance of both the screw-in torque of the cup and the training status of the periarticular muscles.  相似文献   

15.
Polyethylene wear after total hip arthroplasty may occur as a result of normal gait and as a result of subluxation and relocation with impact. Relocation of a subluxed hip may impart a moment to the cup creating sliding as well as compression at the cup liner interface. The purpose of the current study is to quantify, by a validated finite element model, the forces generated in a hip arthroplasty as a result of subluxation relocation and compare them to the forces generated during normal gait. The micromotion between the liner and acetabular shell was quantified by computing the sliding track and the deformation at several points of the interface. A finite element analysis of polyethylene liner stress and liner/cup micromotion in total hip arthroplasty was performed under two dynamic profiles. The first profile was a gait loading profile simulating the force vectors developed in the hip arthroplasty during normal gait. The second profile is generated during subluxation and subsequent relocation of the femoral head. The forces generated by subluxation relocation of a total hip arthroplasty can exceed those forces generated during normal gait. The induced micromotion at the cup polyethylene interface as a result of subluxation can exceed micromotion as a result of the normal gait cycle. This may play a significant role in the generation of backsided wear. Minimizing joint subluxation by restoring balance to the hip joint after arthroplasty should be explored as a strategy to minimize backsided wear.  相似文献   

16.
The elastohydrodynamic lubrication analysis was carried out in this study for a typical metal-on-metal hip-resurfacing prosthesis under a simple steady-state rotation. Both the Reynolds equation and the elasticity equation were coupled and solved numerically by the finite difference method. The finite element method was used to determine the elastic deformation of both the femoral and the acetabular components required for the lubrication analysis. The effect of the radial clearance between the femoral head and the acetabular cup on the predicted film thickness and pressure distribution was investigated. The predicted minimum lubricating film thickness was found to compare favourably with the prediction using the Hamrock and Dowson [J. Lubrication Technol. 100 (1978) 236] formula based on the assumption of ball-on-plane semi-infinite solids. This implies that the non-metallic materials such as bone and cement underlying the metallic components have a small effect on the predicted lubrication performance for the particular metal-on-metal hip-resurfacing prosthesis considered in this study. Under realistic physiological walking conditions, a decrease in the radial clearance from 150 to 50 microm resulted in a 137% increase in the predicted minimum film thickness from 19 to 45 nm. Consequently, given a surface roughness of 0.01 microm for both the metallic femoral and acetabular bearing surfaces, the predicted mixed lubrication regime for the larger clearance was changed to a full fluid film lubrication regime for the smaller clearance. This clearly highlighted the importance of the design and manufacturing parameters on the tribological performance of these hard-on-hard hip prostheses.  相似文献   

17.
In this paper an application of the boundary element method for simulating wear in total hip prosthesis is presented. Several examples including different update periods of the worn acetabular cup, various femoral head sizes and various materials for both the femoral head and the acetabular cup are simulated under the same variable loading conditions for up to 20 years of service. Moreover, two different femoral models are considered in order to investigate the influence of the femoral modelling. The analysis demonstrates that due to the boundary only modelling requirement, the computational time and storage remains low, allowing large service periods to be simulated. Generally, the results obtained are in good agreement with other researchers findings. Moreover, ignoring the bending of the femoral neck in the model, results in a small overestimation of the maximum wear depth, while the volumetric wear is slightly underestimated. However, these differences are trivial considering the reduction of the computational effort.  相似文献   

18.
The life span of a total hip prosthesis is one of the main points on which the long-term success of arthroplasties depends. It is, by now, widely recognized that hip arthroplasty failure is mainly due to the aseptic loosening resulting from the presence of wear debris forming at the contact interface between the femoral head and the cup of the acetabulum. The size of these particles varies from a few micrometers to some tens of micrometers or more. The main aim of this study was therefore to investigate the formation of debris in the microscopic size range. For this purpose, a numerical study was carried out on various mechanisms leading to plastic deformations, which can lead to damage and wear in material. Numerical analyses were performed with a laboratory software program LMGC90, on the evolution of the plastic strains involved in various wear mechanisms on the microscopic scale.  相似文献   

19.
Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.  相似文献   

20.
Femoral head size provides important information on body size in extinct species. Although it is well‐known that femoral head size is correlated with acetabular size, the precision with which femoral head size can be estimated from acetabular size has not been quantified. The availability of accurate 3D surface models of fossil acetabular remains opens the possibility of obtaining accurate estimates of femoral head size from even fragmentary fossil remains [Hammond et al.,: Am J Phys Anthropol 150 (2013) 565–578]. Here we evaluate the relationship between spheres fit to surface models of the femoral head and acetabulum of a large sample of extant anthropoid primates. Sphere diameters are tightly correlated and scale isometrically. In spite of significant taxonomic and possibly functional differences in the relationship between femoral head size and acetabulum size, percent prediction errors of estimated femoral head size remain low regardless of the taxonomic composition of the reference sample. We provide estimates of femoral head size for a series of fossil hominins and monkeys. Am J Phys Anthropol 155:469–475, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   