首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Thyrotropin-releasing hormone (TRH) is involved in a wide range of biological responses. It has a central role in the endocrine system and regulates several neurobiological activities. In the present study, a rapid, sensitive and selective liquid chromatography–mass spectrometry method for the identification and quantification of TRH has been developed. The methodology takes advantage of the specificity of the selected-ion monitoring acquisition mode with a limit of detection of 1 fmol. Furthermore, the MS/MS fragmentation pattern of TRH has been investigated to develop a selected reaction monitoring (SRM) method that allows the detection of a specific b2 product ion at m/z 249.1, corresponding to the N-terminus dipeptide pyroglutamic acid–histidine. The method has been tested on rat hypothalami to evaluate its suitability for the detection within very complex biological samples.  相似文献   

2.
YH439 is a potential drug candidate for the treatment of various hepatic disorders. YH439 and its three metabolites have been identified in rat urine by liquid chromatography–mass spectrometry (LC–MS) and by gas chromatography (GC)–MS. Identification of YH439 and its metabolites was established by comparing their GC retention times and mass spectra with those of the synthesized authentic standards. Both electron impact- and positive chemical ionization MS have been evaluated. The metabolism study was performed in the rat using oral administration of the drug. A major metabolite (YH438) was identified as the N-dealkylation product of YH439. Other identified metabolites were caused by the loss of the methyl thiazolyl amine group (metabolite II) from YH439, the isopropyl hydrogen malonate group (metabolite IV) and the decarboxylated product (metabolite III) of metabolite II.  相似文献   

3.
A liquid chromatography–mass spectrometry (LC–MS) method for the analysis of corticosteroids in equine urine was developed. Corticosteroid conjugates were hydrolysed with β-glucuronidase; free and enzyme-released corticosteroids were then extracted from the samples with ethyl acetate followed by a base wash. The isolated corticosteroids were detected by LC–MS and confirmed by LC–MS–MS in the positive atmospheric pressure chemical ionisation mode. Twenty-three corticosteroids (comprising hydrocortisone, deoxycorticosterone and 21 synthetic corticosteroids), each at 5 ng/ml in urine, could easily be analysed in 10 min.  相似文献   

4.
Dried blood spots (DBS), a micro blood sampling technique, has recently gained interest in drug discovery and development due to its inherent advantages over the conventional whole blood, plasma or serum sample collection. Since the regulatory authorities have agreed to the use of blood as an acceptable biological matrix for drug exposure measurements, its applications have been extended not only to therapeutic drug monitoring but also to toxicokinetic and pharmacokinetic studies. The pharmaceutical industry is keen to promote DBS as a prominent tool in bioanalytical applications due to the financial, ethical and organizational issues involved in clinical trials. This could be accomplished due to the latest advances in modern analytical technology, particularly liquid chromatography–mass spectrometry. The present review discusses some of the emerging liquid chromatography–mass spectrometry technologies in improving DBS analysis for its innovative applications in the development of new drugs.  相似文献   

5.
Oxypurinol is the active metabolite of allopurinol which is used to treat hyperuricaemia associated with gout. Both oxypurinol and allopurinol inhibit xanthine oxidase which forms uric acid from xanthine and hypoxanthine. Plasma oxypurinol concentrations vary substantially between individuals and the source of this variability remains unclear. The aim of this study was to develop an HPLC-tandem mass spectrometry method to measure oxypurinol in urine to facilitate the study of the renal elimination of oxypurinol in patients with gout. Urine samples (50 μL) were prepared by dilution with a solution of acetonitrile/methanol/water (95/2/3, v/v; 2 mL) that contained the internal standard (8-methylxanthine; 1.5 mg/L), followed by centrifugation. An aliquot (2 μL) was injected. Chromatography was performed on an Atlantis HILIC Silica column (3 μm, 100 mm × 2.1 mm, Waters) at 30 °C, using a mobile phase comprised of acetonitrile/methanol/50 mM ammonium acetate in 0.2% formic acid (95/2/3, v/v). Using a flow rate of 0.35 mL/min, the analysis time was 6.0 min. Mass spectrometric detection was by selected reactant monitoring (oxypurinol: m/z 150.8 → 108.0; internal standard: m/z 164.9 → 121.8) in negative electrospray ionization mode. Calibration curves were prepared in drug-free urine across the range 10–200 mg/L and fitted using quadratic regression with a weighting factor of 1/x (r2 > 0.997, n = 7). Quality control samples (20, 80, 150 and 300 mg/L) were used to determine intra-day (n = 5) and inter-day (n = 7) accuracy and imprecision. The inter-day accuracy and imprecision was 96.1–104% and <11.2%, respectively. Urinary oxypurinol samples were stable when subjected to 3 freeze–thaw cycles and when stored at room temperature for up to 6 h. Samples collected from 10 patients, not receiving allopurinol therapy, were screened and showed no significant interferences. The method was suitable for the quantification of oxypurinol in the urine of patients (n = 34) participating in a clinical trial to optimize therapy of gout with allopurinol.  相似文献   

6.
A liquid chromatographic–mass spectrometric (LC–MS) assay was developed and validated for the determination of itraconazole (ITZ) in rat heparinized plasma using reversed-phase HPLC combined with positive atmospheric pressure ionization (API) mass spectrometry. After protein precipitation of plasma samples (0.1 ml) with acetonitrile containing nefazodone as an internal standard (I.S.), a 50-μl aliquot of the supernatant was mixed with 100 μl of 10 mM ammonium formate (pH 4.0). An aliquot of 25 μl of the mixture was injected onto a BDS Hypersil C18 column (50×2 mm; 3 μm) at a flow-rate of 0.3 ml/min. The mobile phase comprising of 10 mM ammonium formate (pH 4) and acetonitrile (60:40, v/v) was used in an isocratic condition, and ITZ was detected in single ion monitoring (SIM) mode. Standard curves were linear (r2≥0.994) over the concentration range of 4–1000 ng/ml. The mean predicted concentrations of the quality control (QC) samples deviated by less than 10% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8% relative standard deviation. Both ITZ and I.S. were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of ITZ was 96%. The validated assay was applied to a pharmacokinetic study of ITZ in rats following administration of a single dose of itraconazole (15 mg/kg).  相似文献   

7.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

8.
Pyrrole (Py)–imidazole (Im) polyamides synthesized by combining N-methylpyrrole and N-methylimidazole amino acids have been identified as novel candidates for gene therapy. In this study, a sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) with an electrospray ionization (ESI) source was developed and validated for the determination and quantification of Py–Im polyamide in rat plasma. Py–Im polyamide was extracted from rat plasma by solid-phase extraction (SPE) using a Waters Oasis® HLB cartridge. Separation was achieved on an ACQUITY UPLC HSS T3 (1.8 μm, 2.1 × 50 mm) column by gradient elution using acetonitrile:distilled water:acetic acid (5:95:0.1, v/v/v) and acetonitrile:distilled water:acetic acid (95:5:0.1, v/v/v). The method was validated over the range of 10–1000 ng/mL and the lower limit of quantification (LLOQ) was 10 ng/mL. This method was successfully applied to the investigation of the pharmacokinetics of Py–Im polyamide after intravenous administration.  相似文献   

9.
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498  416 and 430  372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects.  相似文献   

10.
The biodegradation of alkylpolyglucosides (APGs) was studied under the conditions of the OECD Screening Test with activated sludge as an inoculum. An influence of alkyl and sugar chain length on the biodegradation rate and a central scission pathway of the biodegradation were investigated. The liquid chromatography-electrospray mass spectrometry technique was used for alkylpolyglucoside analysis and for identification and semiquantitative determination of metabolites. It was found that APGs with a longer alkyl chain were biodegraded faster than those with a shorter one. However, a longer sugar chain caused slower biodegradation of APGs. The central scission pathway of biodegradation was also confirmed.  相似文献   

11.
We first detected glutathionyl hemoglobin (Hb) β-chain in hemodialysis patients and healthy subjects using electrospray ionization liquid chromatography–mass spectrometry. The ratio of glutathionyl Hb β-chain to total β-chain was markedly increased in the hemodialysis patients as compared with healthy subjects. Glutathionyl Hb will be used as a new clinical marker of oxidative stress.  相似文献   

12.

Background  

Mass Spectrometry coupled to Liquid Chromatography (LC-MS) is commonly used to analyze the protein content of biological samples in large scale studies. The data resulting from an LC-MS experiment is huge, highly complex and noisy. Accordingly, it has sparked new developments in Bioinformatics, especially in the fields of algorithm development, statistics and software engineering. In a quantitative label-free mass spectrometry experiment, crucial steps are the detection of peptide features in the mass spectra and the alignment of samples by correcting for shifts in retention time. At the moment, it is difficult to compare the plethora of algorithms for these tasks. So far, curated benchmark data exists only for peptide identification algorithms but no data that represents a ground truth for the evaluation of feature detection, alignment and filtering algorithms.  相似文献   

13.
The Micromass Platform LCZ mass detector parameters were optimized for simultaneous recording of the protonated (CsA∼H+), sodium adduct (CsA∼Na+) and potassium adduct (CsA∼K+) of cyclosporin A eluted from a Symmetry Shield RP8 column. The optimized procedure allows a precise analysis of CsA in whole blood or serum without removal of salts prior to analysis. The ratio of the three forms of CsA varied depending on the assay condition and the types of specimens being analyzed. The summation of three ionic forms of CsA detected by LC–ESI-MS is a reliable and simple method to assess CsA concentration in the blood.  相似文献   

14.
Light exposure is one of several conditions used to study the degradation pathways of recombinant monoclonal antibodies. Tryptophan is of particular interest among the 20 amino acids because it is the most photosensitive. Tryptophan degradation forms several products, including an even stronger photosensitizer and several reactive oxygen species. The current study reports a specific peptide mapping procedure to monitor tryptophan degradation. Instead of monitoring peptides using UV 214 nm, fluorescence detection with an excitation wavelength of 295 nm and an emission wavelength of 350 nm was used to enable specific detection of tryptophan-containing peptides. Peaks that decreased in area over time are likely to contain susceptible tryptophan residues. This observation can allow further liquid chromatography–mass spectrometry (LC–MS) analysis to focus only on those peaks to confirm tryptophan degradation products. After confirmation of tryptophan degradation, susceptibility of tryptophan residues can be compared based on the peak area decrease.  相似文献   

15.
《Free radical research》2013,47(8):651-656
Abstract

Malondialdehyde (MDA) is considered to be a biomarker for enzymatic degradation and lipid peroxidation of polyunsaturated fatty acids. Usually, MDA determination from different biological materials is performed by reaction with thiobarbituric acid (TBA) followed by high-performance liquid chromatography (HPLC) analysis and fluorometric detection. As this method lacks specificity and sensitivity, we developed a gas chromatography–mass spectrometry (GC–MS) method based on derivatization of MDA with 2,4-dinitrophenylhydrazine. Representative ions in negative ion chemical ionization (NICI) mode were recorded at m/z 204 for MDA and at m/z 206 for the deuterated analogon (MDA-d2) as internal standard. This stable and precise GC–MS method showed good linearity (r2 = 0.999) and higher specificity and sensitivity than the HPLC method and was validated for both total MDA (t-MDA) and free MDA (f-MDA). Within-day precisions were 1.8–5.4%, between-day precisions were 4.8–9.2%; and accuracies were between 99% and 101% for the whole calibration range (0.156–5.0 μmol/L for t-MDA and 0.039–0.625 μmol/L for f-MDA). Although comparison of t-MDA levels from GC–MS and HPLC results using Passing–Bablok regression analysis as well as Bland–Altman plot showed a correlation of the data, a tendency to increased results for the HPLC values was detectable, due to possible formation of unspecific products of the TBA reaction.  相似文献   

16.
1. The metabolism of flavanone in the rat was studied after oral or intraperitoneal administration of the compound. Flavone and flav-3-ene together with five other unidentified minor metabolites were excreted in the urine. 2. The formation of flavanone metabolites was not suppressed by the administration of high doses of the antibacterial compounds aureomycin and phthaloylsulphathiazole. 3. No aromatic acids that could be attributed to ring cleavage of flavanone were detected. 4. Administration of 100 or 200mg of flavanone daily per rat caused some deaths during the 7-14-day period. 5. The application of combined gas-liquid chromatography/mass spectrometry and proton nuclear-magnetic-resonance spectroscopy to the separation and identification of the flavanone metabolites is described. 6. Measurement of the two major flavanone metabolites was carried out by gas-liquid chromatography.  相似文献   

17.
A sensitive and specific method using ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) was developed for the determination of levetiracetam (LEV) in plasma of neonates. A plasma aliquot of 50 μl was deproteinized by addition of 500 μl methanol which contained 5 μg/ml UCB 17025 as an internal standard. After centrifugation, 50 μl of supernatant was diluted with 1000 μl of 0.1% formic acid–10 mM ammonium formate in water (pH 3.5) (mobile phase solution A) and 2 μl was injected onto the UPLC-system. Compounds were separated on a Acquity UPLC BEH C18 2.1 mm × 100 mm column using gradient elution with mobile phase solution A and 0.1% formic acid in methanol (mobile phase solution B) with a flow rate of 0.4 ml/min and a total runtime of 4.0 min. LEV and the internal standard were detected using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay allowed quantification of LEV plasma concentrations in the range from 0.5 μg/ml to 150 μg/ml. Inter-assay inaccuracy was within ±2.7% and inter-assay precision was less than 4.5%. Matrix effects were minor: the recovery of LEV was between 97.7% and 100%. The developed method required minimal sample preparation and less plasma sample volume compared to earlier published LC–MS/MS methods. The method was successfully applied in a clinical pharmacokinetic study in which neonates received intravenous administrations of LEV for the treatment of neonatal seizures.  相似文献   

18.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed to determine the concentration of eptifibatide in human plasma. Following protein precipitation, the analyte was separated on a reversed-phase C18 column. Acetonitrile:5 mM ammonium acetate:acetic acid (30:70:0.1, v/v/v) was used at a flow-rate of 0.5 mL/min with the isocratic mobile phase. An API 4000 tandem mass spectrometer equipped with a Turbo IonSpray ionization source was used as the detector and was operated in the positive ion mode. “Truncated” multiple reaction monitoring using the transition of m/z 832.6  m/z 832.6 and m/z 931.3  m/z 931.3 was performed to quantify eptifibatide and the internal standard (EPM-05), respectively. The method had a lower limit of quantification of 4.61 ng/mL for eptifibatide. The calibration curve was demonstrated to be linear over the concentration range of 4.61 ? 2770 ng/mL. The intra- and inter-day precisions were less than 10.5% for each QC level, and the inter-day relative errors were 2.0%, 5.6%, and 2.8% for 9.22, 184, and 2490 ng/mL, respectively. The validated method was successfully applied to the quantification of eptifibatide concentration in human plasma after intravenous (i.v.) administration of a 270-μg/kg bolus of eptifibatide and i.v. administration of eptifibatide at a constant rate of infusion of 2 μg/(kg min) for 18 h in order to evaluate the pharmacokinetics.  相似文献   

19.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

20.
This paper reviews liquid chromatographic–mass spectrometric (LC–MS) procedures for the identification and/or quantification of drugs of abuse, therapeutic drugs, poisons and/or their metabolites in biosamples (whole blood, plasma, serum, urine, cerebrospinal fluid, vitreous humor, liver or hair) of humans or animals (cattle, dog, horse, mouse, pig or rat). Papers published from 1995 to early 1997, which are relevant to clinical toxicology, forensic toxicology, doping control or drug metabolism and pharmacokinetics, were taken into consideration. They cover the following analytes: amphetamines, cocaine, lysergide (LSD), opiates, anabolics, antihypertensives, benzodiazepines, cardiac glycosides, corticosteroids, immunosuppressants, neuroleptics, non-steroidal anti-inflammatory drugs (NSAID), opioids, quaternary amines, xanthins, biogenic poisons such as aconitines, aflatoxins, amanitins and nicotine, and pesticides. LC–MS interface types, mass spectral detection modes, sample preparation procedures and chromatographic systems applied in the reviewed papers are discussed. Basic information about the biosample assayed, work-up, LC column, mobile phase, interface type, mass spectral detection mode, and validation data of each procedure is summarized in tables. Examples of typical LC–MS applications are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号