We report a reversed-phase high-performance liquid chromatography method which resolves 13 identified carotenoids and nine unknown carotenoids from human plasma. A Nucleosil C18 column and a Vydac C18 column in series are used with an isocratic solvent system of acetonitrile–methanol containing 50 mM acetate ammonium–dichloromethane–water (70:15:10:5, v/v/v/v) as mobile phase at a flow-rate of 2 ml/min. The intra-day (4.5–8.3%) and inter-day (1.3–12.7%) coefficients of variation are suitable for routine clinical determinations.  相似文献   

2.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

3.
For the determination of cisapride from serum samples, an automated microbore high-performance liquid chromatographic method with column switching has been developed. After serum samples (100 μl) were directly injected onto a Capcell Pak MF Ph-1 pre-column (10×4 mm I.D.), the deproteinization and concentration were carried out by acetonitrile–phosphate buffer (20 mM, pH 7.0) (2:8, v/v) at valve position A. At 2.6 min, the valve was switched to position B and the concentrated analytes were transferred from MF Ph-1 pre-column to a C18 intermediate column (35×2 mm I.D.) using washing solvent. By valve switching to position A at 4.3 min, the analytes were separated on a Capcell Pak C18 UG 120 column (250×1.5 mm I.D.) with acetonitrile–phosphate buffer (20 mM, pH 7.0) (5:5, v/v) at a flow-rate of 0.1 ml/min. Total analysis time per sample was 18 min. The linearity of response was good (r=0.999) over the concentration range of 5–200 ng/ml. The within-day and day-to-day precision (CV) and inaccuracy were less than 3.7% and 3.8%, respectively. The mean recovery was 96.5±2.4% with the detection limit of 2 ng/ml.  相似文献   

4.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of a new oral thrombin inhibitor (compound I) in the blood of rats and dogs. The analyte was deproteinized with a 1.5 volume of methanol and a 0.5 volume of 10% zinc sulfate, and the supernatant was injected into a 5-μm Capcell Pak C18 column (150×4.6 mm I.D.). The mobile phase was a mixture of acetonitrile and 0.2% triethylamine of pH 2.3 (31:69, v/v) with a flow-rate of 1.0 ml/min at UV 231 nm. The retention time of compound I was approximately 9.3 min. The calibration curve was linear over the concentration range of 0.05–100 mg/l for rat blood (r2>0.9995, n=6) and dog blood (r2>0.9993, n=6). The limit of quantitation was 0.05 mg/l for both bloods using a 100-μl sample. For the 5 concentrations (0.05, 0.1, 1, 10, and 100 mg/l), the within-day recovery (n=4) and precision (n=4) were 98.1–104.1% and 1.5–6.8% for rat blood and 95.4–105.7% and 1.4–5.3% for dog blood, respectively. The between-day recovery (n=6) and precision (n=6) were 99.8–105.3% and 3.7–12.6% for rat blood and 87.5–107.1% and 2.9–15.3% for dog blood, respectively. The absolute recoveries were 82.4–93.3%. No interferences from endogenous substances were observed. In conclusion, the presented simple, sensitive, and reproducible HPLC method proved and was used successfully for the determination of compound I in the preclinical pharmacokinetics.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of aspirin and salicylic acid in transdermal perfusates. The compounds were separated on a C8 Nucleosil column (5 μm, 250×4.6 mm) using a mobile phase containing a mixture of water–acetonitrile–orthophosphoric acid (650:350:2, v/v/v) and a flow-rate of 1 ml/min. The transdermal samples were in phosphate-buffered saline (PBS) and could be injected directly onto the HPLC system. The method was reproducible with inter-day R.S.D. values of no greater than 3.46 and 2.60% for aspirin and salicylic acid, respectively. The method was linear over the concentration range 0.2–5.0 μg/ml and had a limit of detection of 0.05 μg/ml for both compounds. For certain samples, it was necessary to ensure that no transmembrane leakage of the aspirin prodrugs had occurred. In these cases, a gradient was introduced by increasing the acetonitrile content of the mobile phase after the salicylic acid had eluted. The method has been applied to the determination of aspirin and salicylic acid in PBS following in vitro application of the compounds to mouse skin samples.  相似文献   

6.
A gradient eluent HPLC analysis in human plasma and urine was developed and validated for methylprednisolone (MP), its prodrug methylprednisolone-21-hemisuccinate (MPS) with the metabolites 6β-hydroxy-6α-methylprednisolone (MPA), 20-hydroxymethylprednisolone (MPC), 6β-hydroxy-20α-hydroxymethylprednisolone (MPB), 6β-hydroxy-20β-hydroxymethylprednisolone (MPE), 20-carboxymethylprednisolone (MPD), methylprednisolone-glucuronide (MPF) and 21-carboxymethylprednisolone (MPX). The column was Cp Spherisorb C8 5 μm, 250 mm×4.6 mm I.D. (Chrompack, Bergen op Zoom, The Netherlands) with a guard column 75 mm×2.1 mm, packed with pellicular reversed-phase. The eluent was a mixture of acetonitrile and 0.067 M KH2PO4 buffer, pH 4.5. At t=0, the eluent consisted of 2% acetonitrile and 98% buffer (v/v). Over the following 35 min the eluent changed linearly until it attained a composition of 50% acetonitrile and 50% buffer (v/v). At 37 min (t=37) the eluent was changed over 5 min to the initial composition, followed by equilibration over 3 min. The flow-rate was 1.5 ml/min and UV detection was achieved at 248 nm. Preliminary pharmacokinetic data were obtained from one patient who showed illustrative plasma concentration–time curves and renal excretion-time profiles after a short-lasting infusion (0.5 h) of 1 g of methylprednisolone hemisuccinate. The half-life of prodrug methylprednisolone-21-hemisuccinate (MPS) was 0.3 h, that of metabolite MPX (21-carboxy MP) was 0.4 h and that of the parent drug methylprednisolone (MP) was 1.4 h. The half-lives of the metabolites are almost similar (4 h). The main compounds in the urine are methylprednisolone hemisuccinate (prodrug, 15.0%), methylprednisolone (parent drug, 14.6%), metabolite MPD (20-carboxy, 11.7%), and metabolite MPB (13.2%). The renal clearance values of metabolites MPB, MPC and MPD are approximately 500 ml/min, that of MP is 100 ml/min.  相似文献   

7.
A high-performance liquid chromatographic assay is described as a routine analytical method for the determination of fumagillin in rainbow trout muscle tissue. Muscle tissue samples (1 g) containing fumagillin were deproteinized with 8 ml of an acetonitrile-water mixture (2:6, v/v). The extracts were purified with a Bond Elut Octyl C8 cartridge column, washed with a water-methanol mixture (95:5, v/v; 4 ml) and fumagillin was eluted with acetonitrile (1 ml). Analytical separations were performed by reversed-phase HPLC with UV detection at 351 nm under gradient conditions. The mobile phase was acetonitrile-0.005 M tetrabutyl ammonium phosphate in water (pH 7.8). The assay is specific and reproducible within the fumagillin range of 20–1000 ng/g and recovery at 20 ng/g was 69.2%. Sample preparation involves the use of a robotic sample preparation system. Gravimetric validation of all operations enabled Good Laboratory Practices to be observed.  相似文献   

8.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

9.
An isocratic high-performance liquid chromatographic method with column switching and direct injection has been developed to determine ciprofloxacin in plasma and Mueller–Hinton broth. An on-line dilution of the sample was performed with a loading mobile phase consisting of 173 mM phosphoric acid. The analyte was retained on a LiChrocart 4-4 precolumn filled with a LiChrospher 100 RP18, 5 μm. An electric-actuated system with two six-port valves allowed a clean-up step with a mixture 20 mM phosphate buffer (pH 3.5)–methanol (97: 3, v/v) and the transfer of the analyte by a back-flush mode to a 150×4.6 mm I.D. column packed with a Kromasil C8 5 μm, using a mobile phase of 20 mM phosphate buffer (pH 3.5)–acetonitrile (85:15, v/v). Fluorescence detection allowed a quantification limit of 0.078 μg/ml with a 40-μl sample size. The method was evaluated to determine its usefulness in studying the pharmacokinetic/pharmacodynamic behaviour of ciprofloxacin in an in vitro model.  相似文献   

10.
A method enabling quantification of R-(−)- and S-(+)-mepivacaine in human plasma in the low nanogram per milliliter range is described. The procedure involves extraction from plasma with diethyl ether, centrifugation, back-extraction into an acidified aqueous solution, washing with a mixture of pentane and isoamylalcohol, alkalinisation, followed by extraction with a mixture of n-pentane and isoamylalcohol. After evaporation of the organic phase, the residue is redissolved in the mobile phase used for the HPLC analysis, which consists of a 6.8:93.2 (v/v) isopropanol-sodium hydrogenphosphate buffer solution with the pH adjusted to 6.8 using phosphoric acid. The HPLC method has been described previously. Separation of the enantiomers is achieved with an α1-AGP column and the UV detection wavelength is 210 nm. The minimal detectable concentration is ca. 3 ng/ml and the lower limit of quantification is 5 ng/ml for each enantiomer. For both enantiomers r is >0.9995 over the plasma enantiomeric concentration range of 10.5–1054 ng/ml.  相似文献   

11.
An optimized method for the determination of flecainide in serum is presented. Extraction using a solid-phase C18 column and chromatography on a stabilized fluorocarbon-bonded silica gel column effectively separate flecainide from an internal standard (a positional isomer of flecainide). The HPLC apparatus and conditions were as follows: analytical column, Fluofix 120N; sample solvent, 20 μl; column temperature, 40°C; detector, Shimadzu RF-5000 fluorescence spectrophotometer (excitation wavelength=300 nm, emission wavelength=370 nm); mobile phase, 0.06% phosphoric acid containing 0.1% tetra-n-butyl ammonium bromide–acetonitrile (75:25, v/v); flow-rate, 1.0 ml/min. The standard curves for flecainide were linear in the concentration range examined (10–2000 ng/ml). The regression equation was y=0.08+0.0078x (r=0.9998). The minimum detectable amount of flecainide was approximately 5 ng/ml. In the within-day study, the precision coefficients of variation were 2.66, 2.18, 2.54, 2.72, 2.88, 2.24, and 3.29% for the 10, 50, 100, 200, 500, 1000, and 1500 ng/ml standards, respectively. The absolute recovery rates of flecainide at each concentrations were 94–100%. The method described provides analytical sensitivity, specificity and reproducibility suitable for both biomedical research and therapeutic drug monitoring.  相似文献   

12.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

13.
A double column-switching high-performance liquid chromatographic (HPLC) method for the determination of concentrations for TAK-603 (T) and its metabolites, T-72258 (M-I) and T-72294 (M-III), in human serum was developed. The analytes were extracted with ethyl acetate from human serum samples treated with triethylamine and injected into the HPLC system. Separation of the analytes was performed on the HPLC system with double column-switching technique. The mobile phases A and B for the first column and the mobile phase C for the second column used were a mixture of methanol–10 mM aqueous ammonium acetate solution (1:1, v/v), methanol and a mixture of methanol–10 mM aqueous ammonium acetate solution (11:9, v/v), respectively. The eluate was monitored with a UV detector at a wavelength of 253 nm. The work-up procedure was reproducible and more than 90% of the analytes could be recovered from human serum. The lower limits of quantitation were all 1 ng/ml for the analytes when 0.5 ml of human serum was used. Standard curves were linear with a correlation coefficient (R) of more than 0.999 in the range of 1–500 ng/ml for T, M-I and M-III in human serum. The intra- and inter-day precision of the method for the various analytes were below 4.8%. The accuracy was good with the deviations between spiked and calculated concentrations of the analytes being within 11.0%. The method was successfully applied to analyze serum samples after an oral administration of T to healthy male volunteers.  相似文献   

14.
A coupled column liquid chromatographic (LC–LC) method for high-speed analysis of the urinary ring-opened benzene metabolite, trans,trans-muconic acid (t,t-MA) is described. Efficient on-line clean-up and concentration of t,t-MA from urine samples was obtained using a 3 μm C18 column (50×4.6 mm I.D.) as the first column (C-1) and a 5 μm C18 semi-permeable surface (SPS) column (150×4.6 mm I.D.) as the second column (C-2). The mobile phases applied consisted, respectively, of methanol–0.05% trifluoroacetic acid (TFA) in water (7:93, v/v) on C-1, and of methanol–0.05% TFA in water (8:92, v/v) on C-2. A rinsing mobile phase of methanol–0.05% TFA in water (25:75, v/v) was used for cleaning C-1 in between analysis. Under these conditions t,t-MA eluted 11 min after injection. Using relatively non-specific UV detection at 264 nm, the selectivity of the assay was enhanced remarkably by the use of LC–LC allowing detection of t,t-MA at urinary levels as low as 50 ng/ml (S/N>9). The study indicated that t,t-MA analysis can be performed by this procedure in less than 20 min requiring only pH adjustment and filtration of the sample as pretreatment. Calibration plots of standard additions of t,t-MA to blank urine over a wide concentration range (50–4000 ng/ml) showed excellent linearity (r>0.999). The method was validated using urine samples collected from rats exposed to low concentrations of benzene vapors (0.1 ppm for 6 h) and by repeating most of the analyses of real samples in the course of measurement sequences. Both the repeatability (n=6, levels 64 and 266 ng/ml) and intra-laboratory reproducibility (n=6, levels 679 and 1486 ng/ml) were below 5%.  相似文献   

15.
An isocratic reversed-phase high-performance liquid chromatographic method for the simultaneous determination of denaverine and its N-monodemethyl metabolite (MD 6) in human plasma is described. The assay involves the extraction with an n-heptane–2-propanol mixture (9:1, v/v) followed by back extraction into 12.5% (w/w) phosphoric acid. The analytes of interest and the internal standard were separated on a Superspher RP8 column using a mobile phase of acetonitrile–0.12 M NH4H2PO4–tetrahydrofuran (24:17.2:1, v/v), adjusted to pH 3 with 85% (w/w) phosphoric acid. Ultraviolet detection was used at an operational wavelength of 220 nm. The retention times of MD 6, denaverine and the internal standard were 5.1, 6.3 and 10.2 min, respectively. The assay was validated according to international requirements and was found to be specific, accurate and precise with a linear range of 2.5–150 ng/ml for denaverine and MD 6. Extraction recoveries for denaverine and MD 6 ranged from 44 to 49% and from 42 to 47%, respectively. The stability of denaverine and MD 6 in plasma was demonstrated after 24 h storage at room temperature, after three freeze–thaw cycles and after 7 months frozen storage below −20°C. The stability of processed samples in the autosampler at room temperature was confirmed after 24 h storage. The analytical method has been applied to analyses of plasma samples from a pharmacokinetic study in man.  相似文献   

16.
An isocratic reversed-phase HPLC method was developed to determine cefepime levels in plasma and vitreous fluid. Cefepime and the internal standard cefadroxil were separated on a Shandon Hypersil BDS C18 column by using a mobile phase of 25 mM sodium dihydrogen phosphate monohydrate (pH 3) and methanol (87:13, v/v). Ultraviolet detection was carried out at 270 nm. The retention times were 4.80 min for cefepime and 7.70 min for cefadroxil. This fast procedure which involves an efficient protein precipitation step (addition of HClO4), allows a quantification limit of 2.52 μg ml−1 and a detection limit of 0.83 μg ml−1. Recoveries and absolute recoveries of cefepime from plasma were 96.13–99.44% and 94–102.5% respectively. The intra-day and inter-day reproducibilities were less than 2% for cefepime at 10, 30, 50 μg ml−1 (n=10).The method was proved to be suitable for determining cefepime levels in human plasma and was modified to measure vitreous fluid samples.  相似文献   

17.
A sensitive and stereospecific HPLC method was developed for the analysis of (−)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-β-cyclodextrin (S-β-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)–absolute ethanol (80:20, v/v) containing 10 mM S-β-CD at a flow-rate of 0.7 ml/min. Recoveries of (−)- and (+)-pentazocine were in the range of 91–93%. Linear calibration curves were obtained in the 20–400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9–7.0% and 1.2–6.2%, respectively, for the (−)-enantiomer and 0.8– 7.6% and 1.2–4.6%, respectively, for the (+)-enantiomer (n=3).  相似文献   

18.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

19.
An isocratic high-performance liquid chromatography (HPLC) method with ultraviolet detection for the simultaneous determination of clozapine and its two major metabolites in human plasma is described. Analytes are concentrated from alkaline plasma by liquid–liquid extraction with n-hexane–isoamyl alcohol (75:25, v/v). The organic phase is back-extracted with 150 μl of 0.1 M dibasic phosphate (pH 2.2 with 25% H3PO4). Triprolidine is used as internal standard. For the chromatographic separation the mobile phase consisted of acetonitrile–0.06 M phosphate buffer, pH 2.7 with 25% phosphoric acid (48:52, v/v). Analytes are eluted at a flow-rate of 1.0 ml/min, separated on a 250×4.60 mm I.D. analytical column packed with 5 μm C6 silica particles, and measured by UV absorbance detection at 254 nm. The separation requires 7 min. Calibration curves for the three analytes are linear within the clinical concentration range. Mean recoveries were 92.7% for clozapine, 82.0% for desmethylclozapine and 70.4% for clozapine N-oxide. C.V. values for intra- and inter-day variabilities were ≤13.8% at concentrations between 50 and 1000 ng/ml. Accuracy, expressed as percentage error, ranged from −19.8 to 2.8%. The method was specific and sensitive with quantitation limits of 2 ng/ml for both clozapine and desmethylclozapine and 5 ng/ml for clozapine N-oxide. Among various psychotropic drugs and their metabolites, only 2-hydroxydesipramine caused significant interference. The method is applicable to pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

20.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of LB71350 in the plasma of dogs. The analyte was deproteinized with 1.5 volumes of methanol and 0.5 volumes of 10% zinc sulfate, and the supernatant was injected into a 5-μm Capcell Pak C18 column (150×4.6 mm I.D.). The mobile phase was a stepwise gradient mixture of acetonitrile and 0.2% triethylamine–HCl with a flow-rate of 1 ml/min and detection at UV 245 nm. The proportion of acetonitrile was kept at 52% for the first 6 min, increased to 100% for the next 0.5 min, kept at 100% for the next 2 min, decreased to 52% for the next 0.5 min, and finally kept at 52% for the next 7 min. The retention time of LB71350 was 6.9 min. The calibration was linear over the concentration range of 0.1–100 mg/l for dog plasma (r>0.997) and the limit of quantitation was 0.1 mg/l using 0.1 ml plasma. The quality control samples were reproducible with acceptable accuracy and precision at 0.1, 1, 10 and 100 mg/l concentrations. The within-day recovery (n=5) was 90.2–93.9%, the between-day recovery (n=5) was 89.5–93.5%, and the absolute between-day recovery (n=5) was 77–81%. The within-day precision (n=5) and between-day precision (n=5) were 2.59–5.82% and 3.17–4.55%, respectively. No interferences from endogenous substances were observed. Taken together, the above HPLC assay method by deproteinization and UV detection was suitable for the determination of LB71350 in the preclinical pharmacokinetics.  相似文献   