首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The incomplete understanding of the relation between power-frequency fields and biological responses raises problems in defining an appropriate metric for exposure assessment and epidemiological studies. Based on evidence from biological experiments, one can define alternative metrics or effects functions that embody the relationship between field exposure patterns and hypothetical health effects. In this paper, we explore the application of the “effects function” approach to occupational exposure data. Our analysis provides examples of exposure assessments based on a range of plausible effects functions. An EMDEX time series data set of ELF frequency (40–800 Hz) magnetic field exposure measurements for electric utility workers was analyzed with several statistical measures and effects functions: average field strength, combination of threshold and exposure duration, and field strength changes. Results were compared for eight job categories: electrician, substation operator, machinist, welder, plant operator, lineman/splicer, meter reader, and clerical. Average field strength yields a different ranking for these job categories than the ranks obtained using other biologically plausible effects functions. Whereas the group of electricians has the highest exposure by average field strength, the group of substation operators has the highest ranking for most of the other effects functions. Plant operators rank highest in the total number of field strength changes greater than 1 μT per hour. The clerical group remains at the lowest end for all of these effects functions. Our analysis suggests that, although average field strength could be used as a surrogate of field exposure for simply classifying exposure into “low” and “high,” this summary measure may be misleading in the relative ranking of job categories in which workers are in “high” fields. These results indicate the relevance of metrics other than average field strength in occupational exposure assessment and in the design and analysis of epidemiological studies. Bioelectromagnetics 18:365–375, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
Flux density and spectral measurements were carried out on magnetic fields generated by several types of motor-driven personal appliances used near the body. Among the units tested were several for which the average flux densities, as determined at the surfaces of the appliance, exceeded 0.4 mT. Time-rates-of-change (dB/dt) for several units exceeded 1000 T/s, and several units exhibited high-frequency components in the low-MHz range. Use of such appliances, although normally of short duration, can represent exposure to magnetic fields of relatively high flux density, which may also have high-frequency components. Compared to other household and commercial sources of magnetic fields, those generated by certain motor-driven personal appliances may represent a significant contribution to time-weighted average exposure and may represent an important source of local induced currents in the body. Furthermore, high-frequency transients that represent only a minor contribution to time-weighted average exposure may generate significant instantaneous induced currents. © 1994 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    3.
    Proliferation of SV40-3T3 mouse fibroblasts and human HL-60 promyelocytes was studied after treatment with a sinusoidal 2 mTrms 50 Hz magnetic field. A single exposure of 60 minutes caused quasicyclic changes in the cell number of SV40-3T3 cultures as function of time after treatment, which was interpreted to be due to the induction of chronobiological mechanisms by the field. Moreover, small variations in cell cycle distribution were measured during postexposure incubation for both cell lines. To discriminate between the effect of the magnetic vector and the induced electric field, HL-60 cell exposure was also performed on organ culture dishes. These dishes consist of two coaxially centered, isolated compartments in which different electric field levels are induced in the medium during treatment. Cell growth was affected in the outer compartment only where the induced electric field ranged from 8 to 12 mVpeak/meter at 2 mT, but it was not affected in the inner compartment (field range 0–4 mVpeak/meter). This suggests that the effects on cell growth are due to the induced electric field and are expressed only above a threshold of between 4 and 8 mVpeak/meter. Bioelectromagnetics 18:177–183, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

    4.
    The closing of material loops is a critical challenge in industrial ecology. It relies mainly on the utilization of recovered materials/parts/products in the original and principal production system while their original function is retained at the highest level possible. In this study, advanced loop-closing systems for the recycling of end-of-life vehicles and electric household appliances are first designed in "Hyogo Eco-town." Second, a methodology for evaluating the eco-efficiency of these systems is developed. Finally, the eco-efficiency of the designed advanced loop-closing strategies for the two products is evaluated, based on the results of materials flow analysis and life-cycle assessment.
    The results show that, compared with conventional recycling systems, when an industrial complex and an advanced loop-closing system for end-of-life vehicles are established, the total economic value increases by 114% and the eco-efficiency in terms of the amount of direct material input is improved by 57%. This system permits the utilization of the by-products, wastes, and recovered materials that originate from other industrial sectors as input to production activities. In the case of end-of-life electric household appliances, an advanced loop-closing strategy to lengthen the product life with parts reuse improves the eco-efficiency in terms of carbon dioxide (CO2) emissions by 4% compared with the conventional replacement of the appliance with a new product along with the material recycling option.  相似文献   

    5.
    Much of the research and reviews on extremely low frequency (ELF) electric and magnetic fields (EMFs) have focused on magnetic rather than electric fields. Some have considered such focus to be inappropriate and have argued that electric fields should be part of both epidemiologic and laboratory work. This paper fills the gap by systematically and critically reviewing electric‐fields literature and by comparing overall strength of evidence for electric versus magnetic fields. The review of possible mechanisms does not provide any specific basis for focusing on electric fields. While laboratory studies of electric fields are few, they do not indicate that electric fields should be the exposure of interest. The existing epidemiology on residential electric‐field exposures and appliance use does not support the conclusion of adverse health effects from electric‐field exposure. Workers in close proximity to high‐voltage transmission lines or substation equipment can be exposed to high electric fields. While there are sporadic reports of increase in cancer in some occupational studies, these are inconsistent and fraught with methodologic problems. Overall, there seems little basis to suppose there might be a risk for electric fields, and, in contrast to magnetic fields, and with a possible exception of occupational epidemiology, there seems little basis for continued research into electric fields. Bioelectromagnetics 31:89–101, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

    6.
    Non-perceptible body currents that arise from contacting exposed conductors that are part of household appliances, are considered in the light of past electric shock safety studies. When these appliances are touched, the older, nongrounded appliances exhibited orders of magnitude greater in-tissue electric fields than the newer grounded appliances or other grounded, exposed, household conductors, such as water faucets.  相似文献   

    7.
    During capillary electrophoresis of negatively charged polysaccharides in polymer solutions as sieving media, concentration fluctuations develop due to electrohydrodynamic instabilities caused by polarization of the polyelectrolytic chains. This leads to deviations from electroneutrality far beyond the Debye layer and segregation of the initially homogeneous sample solution into aggregated sample‐rich domains as verified by epifluorescence videomicroscopy imaging. As a result, anomalous and irregular peak profiles are obtained impeding the characterization of such complex sample mixtures. This effect appears at an electric field strength threshold value that depends on the molecular weight of the solute polymer molecules, pH, type and concentration of the polymer solution sieving media, and buffering conditions. The magnitude increases with increasing field strength and amount of sample injected. The aggregation onset, as evaluated by the value of the threshold potential, is affected by the charge density of the sample polymer molecules and Debye screening effects and investigated through variation of pH and ionic strength, respectively. Exchange of a simple base buffer component for small and multiply charged organic bases markedly increases the electric field strength necessary to trigger the electrohydrodynamic instabilities. Ultimately, the threshold value could be increased more than seven times by addition of an oppositely charged aminodextran polymer, thereby decreasing the analysis time. © 1999 John Wiley & Sons, Inc. Biopoly 49: 515–524, 1999  相似文献   

    8.
    Dietmar Prschke 《Biopolymers》1976,15(10):1917-1928
    Single-stranded polynucleotides are used as model systems for the investigation of conformational changes induced by electric fields. It is demonstrated that the single-strand helix–coil transition in poly(A), poly(dA), and poly(C) can be induced by application of high electric fields. The transition is measured by UV absorbance using polarized light at an angle of 54.8° with respect to the vector of the electric field and by electrodichroism. A linear increase of the absorbance, reflecting the helix-to-coil transition, is observed at increasing field strength. When ions are added to the polymer, electric fields do not induce conformation changes, unless a threshold value of the electric field strength E0 is exceeded. At field strengths above this threshold, the degree of transition is a linear function of the increase in field strength. The threshold values E0 show a linear increase with the logarithm of the ion concentration. Bivalent ions cause thresholds at much lower ion concentrations than mo-novalent ions. The shielding efficiency of ions is correlated to the binding affinity of these ions to the polymer. The conformation changes induced by the field and the existence of thresholds can be explained on the basis of dissociation field effects. Similar threshold effects may be expected for other macromolecules as well as for membrane structures and may be important in the regulation of bioelectricity.  相似文献   

    9.
    A recent epidemiologic study reported associations between leukemia risk in children and their personal use of television (TV) sets, hair dryers, and stereo headsets, and the prenatal use by their mothers of sewing machines. To provide exposure data to aid in the interpretation of these findings, extremely and very low frequency (ELF and VLF) magnetic fields produced by a sample of each type of appliance were characterized in a field study of volunteers conducted in Washington DC and its Maryland suburbs. Questionnaire data regarding children's or mothers' patterns of usage of each type of appliance were also collected. ELF magnetic fields measured 10 cm from the nozzles of hair dryers were elevated over the ambient by a mean factor of 17 when these devices were in use. Fields near headsets being used to listen to music were not distinguishable from ambient levels except at frequencies below and well above 60 Hz and, even then, field levels were < 0.01 microT. Home sewing machines produced ELF magnetic fields that were elevated by a factor of 2.8 over ambient levels at the front surfaces of the lower abdomens of mothers. Estimated mean daily times of usage of hair dryers, stereo headsets, and sewing machines were 2.6, 19, and 17 minutes, respectively. These data and previously published data on TV sets, do not provide a consistent picture of increased (or decreased) leukemia risk in relation to increasing peak or time weighted average (TWA) ELF magnetic field exposure. The data could, however, conceivably be compatible with some more complex biophysical model with unknown properties. Overall, the results of this study provide little evidence supporting the hypothesis that peak or TWA ELF magnetic fields produced by appliances are causally related to the risk of childhood leukemia in children.  相似文献   

    10.
    The purpose of this study was to reproduce and extend two earlier studies of the effects of human exposure to 50 Hz magnetic fields (MF). In a recent paper, we described results of two double-blind investigations performed to examine effects of 100 microT(rms) 50 Hz MF exposure on psychological parameters in the same group of healthy human volunteers. In each exposure session, at 1 week intervals, with sham, continuous, and intermittent (15 s ON/OFF cycles) MF conditions, mood ratings, performance measures, and electrophysiological measures were taken. In the first study, significant amplitude changes were observed in the event-related brain potentials (ERP) recorded during a dichotic listening task. In the second study, latency and reaction time (RT) slowing were seen on a visual discrimination task (P(300) paradigm). Although these results were little related to the number of parameters analysed, they indicate that low level 50 Hz MF might have a slight influence on ERP and RT under specific circumstances of sustained attention. Before concluding that moderately strong MF exposure can influence cognitive function, previous results should be replicated, using the same paradigms with another group of healthy volunteers. In the present study, 18 healthy subjects were exposed to three experimental sessions of 30 min each, given at 1 week intervals. The sessions consisted of continuous 100 microT(rms) 50 Hz MF exposure, sham condition, and bright light (5000 lux) exposure. The study was performed double-blind, with the exposure order counter-balanced. The data on mood, ERP, RT, and other performance measures did not show any differences among the sham exposure, light exposure, and MF exposure conditions. The results of this study do not support the hypothesis that extremely low frequency (ELF) MF exposure affects the brain's electrical activity or cognitive function at field strength (100 microT(rms)) similar to that found in very close proximity of some household and industrial electrical appliances and well in excess of the average MF strength (c. 0.1 microT) found in homes. The sensitivity of the experiment was possibly not sufficient to detect an effect at this relatively low MF, and larger sample sizes would be required in further studies.  相似文献   

    11.
    Growth, mitotic index, and growth rate recovery were determined for Vicia faba L. roots exposed to 60-Hz electric fields of 200, 290, and 360 V/m in an aqueous inorganic nutrient medium (conductivity 0.07-0.09 S/m). Root growth rate decreased in proportion to the increasing strength; the electric field threshold for a growth rate effect was about 230 V/m. The induced transmembrane potential at the threshold exposure was about 4-7 mV. The mitotic index was not affected by an electric field exposure sufficient to reduce root growth rate to about 35% of control. Root growth rate recovery from 31-96% of control occurred in 4 days after cessation of the 360 V/m exposure. The results support the postulate that the site of action of the applied electric fields is the cell membrane.  相似文献   

    12.
    An Analysis of Sustainable Consumption by the Waste Input-Output Model   总被引:1,自引:0,他引:1  
    The extension of the waste input-output (WIO) model to analyze households' sustainable consumption patterns is presented in this article. We estimate direct and indirect emission loads induced by household consumption by the WIO model. The WIO model is much more suitable for the analysis of sustainable consumption than the conventional input-output model because it can deal with the disposal stage of consumed goods as well as the purchase and use stages. A simple method for evaluating income rebound effects is also introduced. As indicators of environmental loads, we estimate carbon dioxide (CO2) emissions and landfill consumption induced by household consumption. The model is applied to some typical sustainable consumption scenarios: shifting transportation modes from a private car to public transportation, the longer use of household electric appliances, and eating at restaurants instead of cooking at home. We found that the income rebound effects should be considered to evaluate environmental loads induced by different consumption patterns.  相似文献   

    13.
    Many in vitro experiments on the biological effects of extremely low frequency (ELF) electromagnetic fields utilize a uniform external magnetic flux density (B) to expose biological materials. A significant number of researchers do not measure or estimate the resulting electric field strength (E) or current density (J) in the sample medium. The magnitude and spatial distribution of the induced E field are highly dependent on the sample geometry and its relative orientation with respect to the magnetic field. We have studied the E fields induced in several of the most frequently used laboratory culture dishes and flasks under various exposure conditions. Measurements and calculations of the E field distributions in the aqueous sample volume in the containers were performed, and a set of simple, quantitative tables was developed. These tables allow a biological researcher to determine, in a straightforward fashion, the magnitudes and distributions of the electric fields that are induced in the aqueous sample when it is subjected to a uniform, sinusoidal magnetic field of known strength and frequency. In addition, we present a novel exposure technique based on a standard organ culture dish containing two circular, concentric annular rings. Exposure of the organ culture dish to a uniform magnetic field induces different average electric fields in the liquid medium in the inner and outer rings. Results of experiments with this system, which were reported in a separate paper, have shown the dominant role of the magnetically induced E field in producing specific biological effects on cells, in vitro. These results emphasize the need to report data about the induced E field in ELF in-vitro studies, involving magnetic field exposures. Our data tables on E and J in standard containers provide simple means to enable determination of these parameters.  相似文献   

    14.
    Electric fields induced in a conductive body by the magnetic field of a current-carrying wire were analyzed theoretically and experimentally to assess the dosimetric importance of highly nonuniform, field-exposure conditions. Experimentation revealed that a 60-Hz magnetic field was inversely proportional to the radius of a wire bundle carrying 100 A within a 0.5-m2 test area. A miniaturized electric field probe was used to measure the electric fields induced in 5-cm-deep, saline-filled models. In the theoretical analysis, numerical estimates of induced fields were made by a spreadsheet method. The theoretical calculations and the measured values of induced electric fields were generally in good agreement. The induced fields were in a plane perpendicular to a vertically incident magnetic field; the maximally induced fields were in areas nearest the wire bundle. The strength of the induced field increased with model size: from 96 microV/cm in a 10 x 10 cm model to 176 microV/cm in a 40 x 40 cm model. The strength of the field induced in a 20 x 20 cm model decreased with increasing model-to-wire spacing: from 132 microV/cm for a 1-cm spacing (2-mT maximum, incident field) to 50 microV/cm for a 6-cm spacing (0.33-mT maximum). The results indicate that increases in local values of nonuniformly incident fields produce relatively small increases in induced electric fields. This finding may be important in dosimetric consideration of circumstances, such as use of electric blankets, in which fields of low average strength are accompanied by intense local fields.  相似文献   

    15.
    Myelogenous leukemia and electric blanket use   总被引:2,自引:0,他引:2  
    In a case-control study of adult acute and chronic myelogenous leukemia in Los Angeles County, we tested the hypothesis that excess exposure to electromagnetic fields from electric blankets was associated with risk of leukemia. We did this by studying 116 cases of acute myelogenous leukemia (AML) and 108 cases of chronic myelogenous leukemia (CML) along with matched neighborhood controls. The cases and controls were queried as to electric blanket use and the risks computed. For AML the risk was 0.9 (95% CI 0.5-1.6) and for CML the risk was 0.8 (95% CI 0.4-1.6). Cases did not differ from controls by duration of use, year of first regular use, year since last use, or socioeconomic status. Our best estimates of exposure indicate that electric blanket use increases overall exposure to electric fields by less than 50% and magnetic fields by less than 100%. We conclude that there is no major leukemogenic risk associated with electric blanket use in Los Angeles County.  相似文献   

    16.
    Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

    17.
    Five groups of pregnant Sprague-Dawley rats were irradiated for 10-40 min on gestation day 9 in a 27.12-MHz radiofrequency field at a magnetic field strength of 55 A/m and an electric field strength of 300 V/m. The specific absorption rate was 10.8 +/- 0.3 W/kg. Exposures were terminated after the rat's colonic temperature reached 41.0 degrees C, 41.5 degrees C, 42.0 degrees C, 42.5 degrees C, or 43.0 degrees C. A control group was sham irradiated at 0 A/m and 0 V/m on gestation day 9, whereas a second control group was untreated. The incidence of both birth defects and prenatal death was directly related to maternal body temperature once a temperature threshold was exceeded. The temperature threshold for both types of effects was approximately 41.5 degrees C. A few pregnant rats died after exposure to 43.0 degrees C, and higher temperatures were nearly always lethal.  相似文献   

    18.
    Increased use of radio and microwave frequencies requires investigations of their effects on living organisms. Duckweed (Lemna minor L.) has been commonly used as a model plant for environmental monitoring. In the present study, duckweed growth and peroxidase activity was evaluated after exposure in a Gigahertz Transversal Electromagnetic (GTEM) cell to electric fields of frequencies 400, 900, and 1900 MHz. The growth of plants exposed for 2 h to the 23 V/m electric field of 900 MHz significantly decreased in comparison with the control, while an electric field of the same strength but at 400 MHz did not have such effect. A modulated field at 900 MHz strongly inhibited the growth, while at 400 MHz modulation did not influence the growth significantly. At both frequencies a longer exposure mostly decreased the growth and the highest electric field (390 V/m) strongly inhibited the growth. Exposure of plants to lower field strength (10 V/m) for 14 h caused significant decrease at 400 and 1900 MHz while 900 MHz did not influence the growth. Peroxidase activity in exposed plants varied, depending on the exposure characteristics. Observed changes were mostly small, except in plants exposed for 2 h to 41 V/m at 900 MHz where a significant increase (41%) was found. Our results suggest that investigated electromagnetic fields (EMFs) might influence plant growth and, to some extent, peroxidase activity. However, the effects of EMFs strongly depended on the characteristics of the field exposure.  相似文献   

    19.
    Global increase in patients seeking orthodontic treatment creates a demand for the use of acrylic resins in removable appliances and retainers. Orthodontic removable appliance wearers have a higher risk of oral infections that are caused by the formation of bacterial and fungal biofilms on the appliance surface. Here, we present the synthetic route for an antibacterial and antifungal organically-modified silicate (ORMOSIL) that has multiple methacryloloxy functionalities attached to a siloxane backbone (quaternary ammonium methacryloxy silicate, or QAMS). By dissolving the water-insoluble, rubbery ORMOSIL in methyl methacrylate, QAMS may be copolymerized with polymethyl methacrylate, and covalently incorporated in the pressure-processed acrylic resin. The latter demonstrated a predominantly contact-killing effect on Streptococcus mutans ATCC 36558 and Actinomyces naselundii ATCC 12104 biofilms, while inhibiting adhesion of Candida albicans ATCC 90028 on the acrylic surface. Apart from its favorable antimicrobial activities, QAMS-containing acrylic resins exhibited decreased water wettability and improved toughness, without adversely affecting the flexural strength and modulus, water sorption and solubility, when compared with QAMS-free acrylic resin. The covalently bound, antimicrobial orthodontic acrylic resin with improved toughness represents advancement over other experimental antimicrobial acrylic resin formulations, in its potential to simultaneously prevent oral infections during appliance wear, and improve the fracture resistance of those appliances.  相似文献   

    20.
    Nowadays, due to the wide use of mobile phones, extensive studies have been carried out on the effects of magnetic field (MF) on public health. In this paper, we study the effect of 217 Hz MF similar to that generated by GSM900 mobile phones on cancer and healthy cells treated with electric pulse and cytotoxic drug. The experiments conducted include exposure to (a) electric pulses alone (4000 square-wave electric pulses with low amplitude of 70 V/cm and frequency of 5 kHz), (b) electric pulses following MF exposure, (c) electrochemotherapy (electric pulses and cytotoxic drug) alone and (d) MF exposure with subsequent electrochemotherapy. The results indicate that the percentage of apoptosis decreases significantly (p < 0.05) in treatment groups using electrochemotherapy after MF exposure compared to that in treatment groups using electrochemotherapy alone. We observed that 217 Hz MF similar to that generated by GSM900 mobile phones can incur resistance of the cells in response to electric pulses. Our findings implied the existence of amplitude window effect in alternations induced by extremely low-frequency MF.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏

    Copyright©北京勤云科技发展有限公司  京ICP备09084417号