首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
PurposeThis study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer.MethodsWe used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D95%, and D2% to planning target volume (PTV), mean dose, V50Gy, V70Gy, V75Gy, and V78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity.ResultsRP and CMO values for PTV D95%, PTV D2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V50Gy, and V70Gy to rectum were superior or comparable to CMO values; RP V75Gy and V78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 ± 55 MU and CMO: 580 ± 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 ± 0.02 and CMO: 0.35 ± 0.03 (p < 0.05).ConclusionsRP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner’s skill and knowledge.  相似文献   

2.
3.

The aim of this study was to investigate the effect of a hybrid technique which results from combining intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for the treatment of cervical cancer patients. Plans made with the hybrid technique and pure IMRT and VMAT were retrospectively compared in 20 patients with cervical cancer at different stages. All plans were made using the same contours based on the original computed tomography (CT) scans. Conformity (CI) and homogeneity (HI) indices of the planning target volumes (PTVs) were calculated for each technique in order to evaluate plan quality. All techniques were compared in terms of dose to organs at risk (OARs), number of monitor units (MUs) and treatment time. It turned out that plans made with the hybrid technique had improved dose conformity and homogeneity compared to plans made only with IMRT and VMAT (p < 0.001). Regarding the OARs, the maximum dose (Dmax) delivered to the bladder, rectum and femoral heads was lower for the hybrid plans compared to the IMRT and VMAT plans (p < 0.001). The volumes irradiated to doses of 50 Gy (V50Gy) for rectum, bladder and bowel were lower for the hybrid plans (p < 0.001, p = 0.002). Furthermore, the treatment time and MU values for the hybrid plans were found to be between of the values for the IMRT and VMAT plans. It is concluded that, as compared to IMRT and VMAT plans, the hybrid plan technique allowed a better conformity and homogeneity for the dose distribution in the PTV and a dose reduction to the OARs.

  相似文献   

4.
AimTo evaluate the performance of volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.BackgroundRapidArc is a novel technique that has recently been made available for clinical use. Planning study was done for volumetric arc modulation with RapidArc against conventional IMRT for head and neck cancers.Materials and methodsTen patients with advanced tumors of the nasopharynx, oropharynx, and hypopharynx were selected for the planning comparison study. PTV was delineated for two different dose levels and planning was done by means of simultaneously integrated boost technique. A total dose of 70 Gy was delivered to the boost volume (PTV boost) and 57.7 Gy to the elective PTV (PTV elective) in 35 equal treatment fractions. PTV boost consisted of the gross tumor volume and lymph nodes containing visible macroscopic tumor or biopsy-proven positive lymph nodes, whereas the PTV elective consisted of elective nodal regions. Planning was done for IMRT using 9 fields and RapidArc with single arc, double arc. Beam was equally placed for IMRT plans. Single arc RapidArc plan utilizes full 360° gantry rotation and double arc consists of 2 co-planar arcs of 360° in clockwise and counter clockwise direction. Collimator was rotated from 35 to 45° to cover the entire tumor, which reduced the tongue and groove effect during gantry rotation. All plans were generated with 6 MV X-rays for CLINAC 2100 Linear Accelerator. Calculations were done in the Eclipse treatment planning system (version 8.6) using the AAA algorithm.ResultsDouble arc plans show superior dose homogeneity in PTV compared to a single arc and IMRT 9 field technique. Target coverage was almost similar in all the techniques. The sparing of spinal cord in terms of the maximum dose was better in the double arc technique by 4.5% when compared to the IMRT 9 field and single arc techniques. For healthy tissue, no significant changes were observed between the plans in terms of the mean dose and integral dose. But RapidArc plans showed a reduction in the volume of the healthy tissue irradiated at V15 Gy (5.81% for single arc and 4.69% for double arc) and V20 Gy (7.55% for single arc and 5.89% for double arc) dose levels when compared to the 9-Field IMRT technique. For brain stem, maximum dose was similar in all the techniques. The average MU (±SD) needed to deliver the dose of 200 cGy per fraction was 474 ± 80 MU and 447 ± 45 MU for double arc and single arc as against 948 ± 162 MU for the 9-Field IMRT plan. A considerable reduction in maximum dose to the mandible by 6.05% was observed with double arc plan. Double arc shows a reduction in the parotid mean dose when compared with single arc and IMRT plans.ConclusionRapidArc using double arc provided a significant sparing of OARs and healthy tissue without compromising target coverage compared to IMRT. The main disadvantage with IMRT observed was higher monitor units and longer treatment time.  相似文献   

5.
PurposeStudies using split field IMRT to spare dysphagia/aspiration related structures (DARS) have raised concern regarding dose uncertainty at matchline. This study explores the utility of hybrid VMAT in sparing the DARS and assesses matchline dose uncertainty in postoperative oral cavity cancer patients and compares it with VMAT.Methods & materialsTen postoperative oral cavity cancer patients were planned with h-VMAT and VMAT using the same planning CT dataset. PTV and DARS were contoured using standard delineation guidelines. In h-VMAT 80% of the neck dose was planned using AP/PA technique and then VMAT optimization was done for the total PTV by keeping the corresponding AP/PA plan as the base dose. Planning goal for PTV was V95%  95% and for DARS, adequate sparing. Plans and dose volume histograms were analyzed using dosimetric indices. Absolute point and portal dose measurements were done for h-VMAT plans to verify dose at the matchline.ResultsCoverage in both the techniques was comparable. Significant differences were observed in mean doses to DARS (Larynx: 24.36 ± 2.51 versus 16.88 ± 2.41 Gy; p < 0.0006, Pharyngeal constrictors: 25.16 ± 2.41 versus 21.2 ± 2.1 Gy; p < 0.005, Esophageal inlet: 18.71 ± 2 versus 12.06 ± 0.79 Gy; p < 0.0002) favoring h-VMAT. Total MU in both the techniques was comparable. Average percentage variations in point dose measurements in h-VMAT done at +3.5 and −3.5 positions were (1.47 ± 1.48 and 2.28 ± 1.35%) respectively. Average gamma agreement for portal dose measured was 97.07%.Conclusionh-VMAT achieves better sparing of DARS with no matchline dose uncertainty. Since these patients have swallowing dysfunction post-operatively, attempts should be made to spare these critical structures as much as possible.  相似文献   

6.
PurposeThe log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error.Methods and materialsModified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5 mm in opposite directions and systematic leaf shifts: ±1.0 mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.ResultsFor MLC leaves calibrated within ±0.5 mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32 ± 0.27% and 0.82 ± 0.17 Gy for PTV and spinal cord, respectively, and in prostate plans 1.22 ± 0.36%, 0.95 ± 0.14 Gy, and 0.45 ± 0.08 Gy for PTV, rectum, and bladder, respectively.ConclusionsIn this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.  相似文献   

7.
PurposeWe investigated the feasibility of robust optimization for volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) for liver cancer in comparison with planning target volume (PTV)-based optimized plans. Treatment plan quality, robustness, complexity, and accuracy of dose delivery were assessed.MethodsTen liver cancer patients were selected for this study. PTV-based optimized plans with an 8-mm PTV margin and robust optimized plans with an 8-mm setup uncertainty were generated. Plan perturbed doses were evaluated using a setup error of 8 mm in all directions from the isocenter. The dosimetric comparison parameters were clinical target volume (CTV) doses (D98%, D50%, and D2%), liver doses, and monitor unit (MU). Plan complexity was evaluated using the modulation complexity score for VMAT (MCSv).ResultsThere was no significant difference between the two optimizations with respect to CTV doses and MUs. Robust optimized plans had a higher liver dose than did PTV-based optimized plans. Plan perturbed dose evaluations showed that doses to the CTV for the robust optimized plans had small variations. Robust optimized plans were less complex than PTV-based optimized plans. Robust optimized plans had statistically significant fewer leaf position errors than did PTV-based optimized plans.ConclusionsComparison of treatment plan quality, robustness, and plan complexity of both optimizations showed that robust optimization could be feasibile for VMAT of liver cancer.  相似文献   

8.
PurposeRadiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks.MethodsFor each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency.ResultsPlan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average Dmean −7%) and bowel sparing (Dmean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose (Dmean +42%) in stage 1 and lower rectum dose (Dmean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively.ConclusionMCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal.  相似文献   

9.
ObjectiveTo investigate the potential of Particle Swarm Optimization (PSO) for fully automatic VMAT radiotherapy (RT) treatment planning.Material and MethodsIn PSO a solution space of planning constraints is searched for the best possible RT plan in an iterative, statistical method, optimizing a population of candidate solutions. To identify the best candidate solution and for final evaluation a plan quality score (PQS), based on dose volume histogram (DVH) parameters, was introduced.Automatic PSO-based RT planning was used for N = 10 postoperative prostate cancer cases, retrospectively taken from our clinical database, with a prescribed dose of EUD = 66 Gy in addition to two constraints for rectum and one for bladder. Resulting PSO-based plans were compared dosimetrically to manually generated VMAT plans.ResultsPSO successfully proposed treatment plans comparable to manually optimized ones in 9/10 cases. The median (range) PTV EUD was 65.4 Gy (64.7–66.0) for manual and 65.3 Gy (62.5–65.5) for PSO plans, respectively. However PSO plans achieved significantly lower doses in rectum D2% 67.0 Gy (66.5–67.5) vs. 66.1 Gy (64.7–66.5, p = 0.016). All other evaluated parameters (PTV D98% and D2%, rectum V40Gy and V60Gy, bladder D2% and V60Gy) were comparable in both plans. Manual plans had lower PQS compared to PSO plans with −0.82 (−16.43–1.08) vs. 0.91 (−5.98–6.25).ConclusionPSO allows for fully automatic generation of VMAT plans with plan quality comparable to manually optimized plans. However, before clinical implementation further research is needed concerning further adaptation of PSO-specific parameters and the refinement of the PQS.  相似文献   

10.
AimTo assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction.BackgroundImplementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution.Materials and methodsSeventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed.ResultsIn 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively.ConclusionSufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.  相似文献   

11.
Background and purposeTomoDirect (TD) can only operate in free-breathing. The purpose of this study is to compare TD with breath-hold 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) techniques for left breast treatments, and to determine if the lack of respiratory gating is a handicap for cardiac sparing.Materials and methods15 patients treated for left breast had two computed tomography simulation, in free breathing (FB) and in deep-inspiration breath-hold (DIBH). Four treatments were planned: TD-FB, 3DCRT-FB, 3DCRT-DIBH and IMRT-DIBH. Dose to PTV, heart, lungs, right breast and patient were compared.ResultsA slightly lower cardiac mean dose is found for 3DCRT-DIBH than for TD-FB group (1.99 Gy Vs 2.89 Gy, p = 0.0462), while no statistical difference is found for heart V20. TD-FB plans show the best PTV dose homogeneity (0.053, p < 0.001) and the lowest left lung mean dose (5.16 Gy, p < 0.001). No major differences are found for the other organs.ConclusionsTomoDirect and breath-hold 3DCRT are complementary techniques for left breast treatments: for a minority of patients, respiratory gating is mandatory to lower cardiac dose; for the remaining majority of patients, TomoDirect achieves better PTV homogeneity and reduced left lung dose, with cardiac dose equivalent to 3DCRT-DIBH.  相似文献   

12.
AimThis study aimed to investigate whether IMRT using VMAT is a viable and safe solution in dose escalated RT in these patients.BackgroundAn increasing number of prostate cancer patients are elderly and have hip prostheses. These implants pose challenges in radiotherapy treatment planning. Although intensity modulated radiotherapy (IMRT) is commonly used, there is a lack of clinical studies documenting its efficacy and toxicities in this subgroup of patients.Materials and methodsThe data from 23 patients with hip prostheses and non-metastatic prostate cancer treated with VMAT (volumetric modulated arc therapy) between 2009 and 2011, were retrospectively analyzed. Baseline characteristics, treatment details and outcome data were collected on all patients. The median follow up was 40.9 months. MRI-CT image fusion was performed and the treatment plans were created using RapidArc™ (RA) techniques utilizing 1 or 2 arcs and 10 MV photon beams.Results96% of patients were treated with a dose of 72 Gy/32 fractions over 44 days. 21/23 plans met the PTV targets. The mean homogeneity index was 1.07. 20/23 plans met all OAR constraints (rectum, bladder). Two plans deviated from rectal constraints, four from bladder constraints; all were classed as minor deviations. One patient experienced late grade 3 genitourinary toxicity. Three other patients experienced late grade 2 or lower gastrointestinal toxicity. One patient had biochemical failure and one had a non-prostate cancer related death.ConclusionsVMAT provides an elegant solution to deliver dose escalated RT in patients with unilateral and bilateral hip replacements with minimal acute and late toxicities.  相似文献   

13.
AimTo assess a class solution template for volumetric-modulated arc therapy (VMAT) for prostate cancer using plan analysis software.BackgroundVMAT is a development of intensity-modulated radiotherapy (IMRT) with potential advantages for the delivery of radiotherapy (RT) in prostate cancer. Class solutions are increasingly used for facilitating RT planning. Plan analysis software provides an objective tool for evaluating class solutions.Materials and methodsThe class solution for VMAT was based on the current static field IMRT template. The plans of 77 prostate cancer patients were evaluated using a set of in-house plan quality metrics (scores) (PlanIQ™, Sun Nuclear Corporation). The metrics compared the class solution for VMAT planning with the IMRT template and the delivered clinical plan (CP). Eight metrics were associated with target coverage and ten with organs-at-risk (OAR). Individual metrics were summed and the combined scores were subjected to non-parametric analysis. The low-dose wash for both static IMRT and VMAT plans were evaluated using 40 Gy and 25 Gy isodose volumes.ResultsVMAT plans were of equal or better quality than the IMRT template and CP for target coverage (combined score) and OAR combined score. The 40 Gy isodose volume was marginally higher with VMAT than IMRT (4.9%) but lower than CP (−6.6%)(P = 0.0074). The 25 Gy volume was significantly lower with VMAT than both IMRT (−32.7%) and CP (−34.4%)(P < 0.00001).ConclusionsAutomated VMAT planning for prostate cancer is feasible and the plans are equal to or better than the current IMRT class solution and the delivered clinical plan.  相似文献   

14.
15.
AimTo assess the performance of the monitor unit (MU) Objective tool in Eclipse treatment planning system (TPS) utilizing volumetric modulated arc therapy (VMAT) for rectal cancer.BackgroundEclipse VMAT planning module includes a tool to control the number of MUs delivered: the MU Objective tool. This tool could be utilized to reduce the total number of MUs in rectal cancer treatments.Materials and methods20 rectal cancer patients were retrospectively studied using VMAT and the MU Objective tool. The baseline plan for each patient was selected as the one with no usage of the MU Objective tool. The number of MUs of this plan was set to be the reference number of MUs (MUref). Five plans were re-optimized for each patient only varying the Max MU parameter. The selected values were 30%, 60%, 90%, 120% and 150% of MUref for each patient. Differences with respect to the baseline plan were evaluated regarding MU number and parameters for PTVs coverage evaluation, PTVs homogeneity and OARs doses assessment. A two-tailed, paired-samples t-test was used to quantify these differences.ResultsAverage relative differences in MU number obtained was 10% for Max MU values of 30% and 60% of MUref, respectively (p < 0.03). PTVs coverage and homogeneity were not compromised and discrepancies obtained with respect to baseline plans were not significant. Furthermore, maximum OARs doses deviations were also not significant.ConclusionsA 10% reduction in the MU number could be obtained without an alteration of PTV coverage and OARs doses for rectal cancer.  相似文献   

16.
The impact of a rectal spacer and an increased near maximum target dose in VMAT prostate SBRT is studied.For a group of 11 patients (35 Gy-in-five-fractions VMAT prostate SBRT) a set of 4 plans were generated, namely two VMAT plans, with D2%  37.5 Gy (Hom) and with D2%  40.2 Gy (Het), were created for each of two CT scans taken before (NoSpc) and after (Spc) transperineal spacer insertion. Consequently the methodology for parameter invariant TCP (tumor control probability) plan ranking was applied for comparison of the plans in terms of tumor control. NTCPs (normal tissue complication probabilities) were calculated for rectum and bladder using Lyman’s model.For all 11 patients the TCP plan ranking has shown that the Het plans would perform considerably better in TCP terms than the Hom ones. The plans without rectal spacer were ranked worse compared to those with rectal spacer except for one set of Hom plans. The calculated NTCPs for rectum produced by the Het plans were quite similar to the NTCPs of the Hom ones. The rectal NTCPs of the Hom Spc plans were always lower than the NTCPs of the Hom NoSpc plans. The NTCP values for bladder were extremely low in all cases.The use of rectal spacer leads in general to lower risk of rectal complications, as expected, and even to better tumor control. Plans with increased near maximum target dose (D2%  40.2 Gy) are expected to perform much better in terms of tumor control than those with D2%  37.5 Gy.  相似文献   

17.
PurposeTo investigate different volumetric modulated arc therapy (VMAT) field designs for lymph node positive breast cancer patients when compared to conventional static fields and standard VMAT designs.MethodsNineteen breast cancer patients with lymph node involvement (eleven left and eight right sided) were retrospectively analyzed with different arc designs. Proposed split arc designs with total rotations of 2 × 190° and 2 × 240° were compared to conventional field in field (FinF) and previously published non-split arc techniques with the same amount of total rotations.ResultsAll VMAT plans were superior in dose conformity, when compared to the FinF plans. Split arc design decreased significantly ipsilateral lung dose and heart V5Gy for both left and right sided cases, when compared to non-split VMAT designs. For left sided cases no significant differences were seen in contralateral lung mean dose or V5Gy between different VMAT designs. For right sided cases the contralateral lung dose V5Gy was significantly higher in split VMAT group, when compared to non-split VMAT designs. The contralateral breast dose V5Gy increased significantly for split VMAT plans for both sides, when compared to non-split VMAT designs or FinF plans.ConclusionsThe proposed split VMAT technique was shown to be superior to previously published non-split VMAT and conventional FinF techniques significantly reducing dose to the ipsilateral lung and heart. However, this came with the expense of an increase in the dose to the contralateral breast and for right-sided cases to the contralateral lung.  相似文献   

18.
PurposeTo increase the superficial dose and reduce the brain dose for radiotherapy of scalp angiosarcoma, we propose a novel irradiation technique of tangential irradiation volumetric modulated arc therapy (TI-VMAT).MethodsTI-VMAT and the conventional VMAT treatment plans for thirteen scalp angiosarcoma patients were created with a prescribed dose of 70 Gy. Each treatment was normalized to cover 95% of the planning target volume (PTV) with its prescribed dose. To realize TI-VMAT, an avoidance structure (AS) function was applied. AS was defined as a contour subtracted PTV by a certain space from the brain contour. TI-VMAT treatment plans for six different spaces between PTV and AS were developed and compared with the conventional VMAT treatment plan with respect to the following dosimetric parameters: homogeneity index (HI) and conformity index (CI) of the PTV, mean brain dose, and brain volume irradiated with 20% (V20% [cc]), 40% (V40% [cc]), 60% (V60% [cc]), 80% (V80% [cc]), and 100% (V100% [cc]) of the prescribed dose.ResultsHI and CI were comparable between TI-VMAT and the conventional VMAT, the mean brain dose for TI-VMAT with AS defined by a space of 2.0 cm and jaw tracking was 14.27 Gy, which was significantly lower than that for the conventional VMAT (21.20 Gy). In addition, dosimetric parameters such as V20% [cc] were significantly suppressed compared to those for high doses.ConclusionOur proposed irradiation technique TI-VMAT shows the potential to reduce radiation doses in the brain with maintaining higher dose coverage on the PTV.  相似文献   

19.
20.
IntroductionWe aimed to determine whether the changes in muscle activity (in terms of both gross electromyography (EMG) and motor unit (MU) discharge characteristics) observed during pain are spatially organized with respect to pain location within a muscle which is the main contributor of the task.MethodsSurface and fine-wire EMG was recorded during matched low-force isometric plantarflexion from soleus (from four quadrants with fine-wire EMG and from the medial/lateral sides with surface EMG), both gastrocnemii heads, peroneus longus, and tibialis anterior. Four conditions were tested: two control conditions that each preceded contractions with pain induced in either the lateral (PainL) or medial (PainM) side of soleus.ResultsNeither the presence (p = 0.28) nor location (p = 0.19) of pain significantly altered gross muscle activity of any location (lateral/medial side of soleus, gastrocnemii, peroneus longus and tibialis anterior). Group data from 196 MUs show redistribution of MU activity throughout the four quadrants of soleus, irrespective of pain location. The significant decrease of MU discharge rate during pain (p < 0.0001; PainL: 7.3 ± 0.9–6.9 ± 1.1 Hz, PainM: 7.0 ± 1.1 to 6.6 ± 1.1 Hz) was similar for all quadrants of the soleus (p = 0.43), regardless of the pain location (p = 0.98). There was large inter-participant variation in respect to the characteristics of the altered MU discharge with pain.ConclusionResults from both surface and fine-wire EMG recordings do not support the hypothesis that muscle activity is reorganized in a simple systematic manner with respect to pain location.  相似文献   