首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This in vivo study investigated the mechanical properties of apical scoliotic vertebrae using computed tomography (CT) and finite element (FE) meshing. CT examination was performed on seven scoliotic girls. FE meshing of each vertebral body allowed automatic mapping of the CT scan and the visualisation of the bone density distribution. Centroids and mass centres were compared to analyse the mechanical properties distribution. Compared to the centroid, the mass centre migrated into the concavity of the curvature. The three vertebrae of a same patient had the same body migration behaviour because they were located at the curvature apex. This observation was verified in the coronal plane, but not in the sagittal plane. These results represent new data over few geometrical analyses of scoliotic vertebrae. Same in vivo personalisation of mechanical properties should be performed on intervertebral discs or ligaments to personalise stiffness properties of the spine for the biomechanical modelling of human torso. Moreover, do this mechanical deformation of scoliotic vertebrae, that appears before the vertebral wedging, could be a predictive tool in scoliosis treatment?  相似文献   

2.

Background

Vertebral wedging is associated with spinal deformity progression in adolescent idiopathic scoliosis. Reporting frontal and sagittal wedging separately could be misleading since these are projected values of a single three-dimensional deformation of the vertebral body. The objectives of this study were to determine if three-dimensional vertebral body wedging is present in mild scoliosis and if there are a preferential vertebral level, position and plane of deformation with increasing scoliotic severity.

Methodology

Twenty-seven adolescent idiopathic scoliotic girls with mild to moderate Cobb angles (10° to 50°) participated in this study. All subjects had at least one set of bi-planar radiographs taken with the EOS® X-ray imaging system prior to any treatment. Subjects were divided into two groups, separating the mild (under 20°) from the moderate (20° and over) spinal scoliotic deformities. Wedging was calculated in three different geometric planes with respect to the smallest edge of the vertebral body.

Results

Factorial analyses of variance revealed a main effect for the scoliosis severity but no main effect of vertebral Levels (apex and each of the three vertebrae above and below it) (F = 1.78, p = 0.101). Main effects of vertebral Positions (apex and above or below it) (F = 4.20, p = 0.015) and wedging Planes (F = 34.36, p<0.001) were also noted. Post-hoc analysis demonstrated a greater wedging in the inferior group of vertebrae (3.6°) than the superior group (2.9°, p = 0.019) and a significantly greater wedging (p≤0.03) along the sagittal plane (4.3°).

Conclusions

Vertebral wedging was present in mild scoliosis and increased as the scoliosis progressed. The greater wedging of the inferior group of vertebrae could be important in estimating the most distal vertebral segment to be restrained by bracing or to be fused in surgery. Largest vertebral body wedging values obtained in the sagittal plane support the claim that scoliosis could be initiated through a hypokyphosis.  相似文献   

3.
ObjectivesAccording to the inter-individual variability of bone mechanical properties, subject-specific evaluation of the cancellous bone Young's modulus is needed to build finite-element models predicting vertebral strength with accuracy. Relationships based on the density assessed by quantitative computed tomography were proposed. However, quantitative computed tomography is not always suited for the analysis of the whole spine for patients’ follow-up because of the high radiation dose. Hence, this study aims at evaluating the mechanical properties of the vertebral cancellous bone using a low-dose X-ray device.Material and methodsNineteen vertebrae were considered. Biplanar radiographs were made using the low-dose EOS® system with a dual-energy modality to evaluate antero-posterior and lateral areal bone mineral densities. A cylindrical sample was extracted from each vertebral body and tested until failure to assess the Young's modulus and the ultimate stress of the vertebral cancellous bone.Results and discussionMechanical properties were significantly related to the EOS® areal densities. On one hand, the relationships remained less predictive than those based on quantitative computed tomography, but on the other hand, they better predict mechanical properties than previous studies using dual X-ray absorptiometry (clinical gold standard system for density assessment).ConclusionThe study shows the feasibility to predict the Young's modulus of the vertebral cancellous bone from the whole vertebral areal bone mineral density (BMD). It gives promising prospects to build finite-element models, including both subject-specific geometry and subject-specific mechanical properties by using a low-dose X-ray device for regions where high radiation doses would limit tomography assessment possibilities.  相似文献   

4.
This study was designed to compare the compressive mechanical properties of filler materials, Wood's metal, dental stone, and polymethylmethacrylate (PMMA), which are widely used for performing structural testing of whole vertebrae. The effect of strain rate and specimen size on the mechanical properties of the filler materials was examined using standardized specimens and mechanical testing. Because Wood's metal can be reused after remelting, the effect of remelting on the mechanical properties was tested by comparing them before and after remelting. Finite element (FE) models were built to simulate the effect of filler material size and properties on the stiffness of vertebral body construct in compression. Modulus, yield strain, and yield strength were not different between batches (melt-remelt) of Wood's metal. Strain rate had no effect on the modulus of Wood's metal, however, Young's modulus decreased with increasing strain rate in dental stone whereas increased in PMMA. Both Wood's metal and dental stone were significantly stiffer than PMMA (12.7 +/- 1.8 GPa, 10.4 +/- 3.4 GPa, and 2.9 +/- 0.4 GPa, respectively). PMMA had greater yield strength than Wood's metal (62.9 +/- 8.7 MPa and 26.2 +/- 2.6 MPa). All materials exhibited size-dependent modulus values. The FE results indicated that filler materials, if not accounted for, could cause more than 9% variation in vertebral body stiffness. We conclude that Wood's metal is a superior moldable bonding material for biomechanical testing of whole bones, especially whole vertebrae, compared to the other candidate materials.  相似文献   

5.
Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.  相似文献   

6.
This study validated two different high-resolution peripheral quantitative computer tomography (HR-pQCT)-based finite element (FE) approaches, enhanced homogenised continuum-level (hFE) and micro-finite element (μFE) models, by comparing them with compression test results of vertebral body sections. Thirty-five vertebral body sections were prepared by removing endplates and posterior elements, scanned with HR-pQCT and tested in compression up to failure. Linear hFE and μFE models were created from segmented and grey-level CT images, and apparent model stiffness values were compared with experimental stiffness as well as strength results. Experimental and numerical apparent elastic properties based on grey-level/segmented CT images (N=35) correlated well for μFE (r2=0.748/0.842) and hFE models (r2=0.741/0.864). Vertebral section stiffness values from the linear μFE/hFE models estimated experimental ultimate apparent strength very well (r2=0.920/0.927). Calibrated hFE models were able to predict quantitatively apparent stiffness with the same accuracy as μFE models. However, hFE models needed no back-calculation of a tissue modulus or any kind of fitting and were computationally much cheaper.  相似文献   

7.
目的:探讨椎体静脉稀疏区注入骨水泥对骨质疏松椎体压缩性骨折患者行经皮穿刺椎体成形术(percutaneous vertebroplasty,PVP)术中骨水泥渗漏的影响。方法:选择西安交通大学第二附属医院2014年1月至2018年6月收治的61例骨质疏松椎体压缩性骨折患者,根据骨水泥注入区域的不同,将所有患者分为A组(30例)及B组(31例),A组骨水泥注入区域为椎体静脉密集区(椎体中1/3平面处),B组骨水泥注入区域为椎体静脉稀疏区(椎体上1/3及下1/3平面处),对比两组的骨水泥渗漏率,术前、术后6个月时的视觉模拟评分(Visual analogue scale,VAS),治疗中的骨水泥用量、椎体高度恢复率及cobb角恢复度数。结果:B组的骨水泥渗漏率及骨水泥用量均明显低于A组(P0.05)。两组的VAS评分、椎体高度恢复率、cobb角恢复情况对比差异无统计学意义(P0.05)。结论:与椎体静脉密集区相比,在椎体静脉稀疏区注入骨水泥可显著降低骨质疏松椎体压缩性骨折患者PVP术中骨水泥渗漏率,椎体静脉稀疏区可作为PVP术中骨水泥注射的一个相对安全区域。  相似文献   

8.
Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more compatible with real mechanical behavior of trabecular bone. A new image based MOS (Mechanic of Solids) parameter named minimum sectional strength ((σuA)min) was used for the ultimate compressive strength prediction. Subsequently, the samples were destructively tested under uniaxial compression and their experimental ultimate compressive strengths were obtained. Results indicated that our new implemented FE model can predict ultimate compressive strength of human vertebra with a correlation coefficient (R2 = 0.94) better than usual linear and nonlinear FE models (R2 = 0.83 and 0.85 respectively). The image based parameter introduced in this study ((σuA)min) was also correlated well with the experimental results (R2 = 0.86). Although nonlinear FE method with new implemented material model predicts compressive strength better than the (σuA)min, this parameter is clinically more feasible due to its simplicity and lower computational costs. This can make future applications of the (σuA)min more justified for human vertebral body compressive strength prediction.  相似文献   

9.
Biomechanical analyses of Harrington distraction, Harrington distraction-compression, Cotrel and Luque correction techniques simulated mechanically on a three-dimensional mathematical model of scoliotic spines are developed and relationships between mechanical forces and achievable corrections are derived in terms of Cobb angle, vertebral inclination from the frontal plane, and bi-plane bending stiffness of motion segments. For all four systems, nomograms between Cobb angles and corrective forces with correction factors as parameters are prepared in terms of given bi-plane characteristics of scoliotic spines. Parametric studies to show the influence of the torsion plane bending stiffness of motion segments and vertebral inclinations from the frontal plane on the mechanical effectiveness of the surgical correction techniques are presented. The mechanical effectiveness of each of the four surgical correction techniques determined with the use of this model compares reasonably well with the clinical findings.  相似文献   

10.
Finite element models have been widely employed in an effort to quantify the stress and strain distribution around implanted prostheses and to explore the influence of these distributions on their long-term stability. In order to provide meaningful predictions, such models must contain an appropriate reflection of mechanical properties. Detailed geometrical and density information is now readily available from CT scanning. However, despite the use of phantoms, a method of determining mechanical properties (or elastic constants) from bone density has yet to be made available in a usable form.In this study, a cadaveric bone was CT scanned and its natural frequencies were measured using modal analysis. Using the geometry obtained from the CT scan data, a finite element mesh was created with the distribution of density established by matching the mass of the FE bone model with the mass of the cadaveric bone. The maximum values of the orthotropic elastic constants were then established by matching the predictions from FE modal analyses to the experimental natural frequencies, giving a maximum error of 7.8% over 4 modes of vibration. Finally, the elastic constants of the bone derived from the analyses were compared with those measured using ultrasound techniques. This produced a difference of <1% for both the maximum density and axial Young's Modulus. This study has thereby produced an orthotropic finite element model of a human femur. More importantly, however, is the implication that it is possible to create a valid FE model by simply comparing the FE results with the measured resonant frequency of the CT scanned bone.  相似文献   

11.
In most bony fishes vertebral column strain during locomotion is almost exclusively in the intervertebral joints, and when these joints move there is the potential to store and release strain energy. Since cartilaginous fishes have poorly mineralized vertebral centra, we tested whether the vertebral bodies undergo substantial strain and thus may be sites of energy storage during locomotion. We measured axial strains of the intervertebral joints and vertebrae in vivo and ex vivo to characterize the dynamic behavior of the vertebral column. We used sonomicrometry to directly measure in vivo and in situ strains of intervertebral joints and vertebrae of Squalus acanthias swimming in a flume. For ex vivo measurements, we used a materials testing system to dynamically bend segments of vertebral column at frequencies ranging from 0.25 to 1.00 Hz and a range of physiologically relevant curvatures, which were determined using a kinematic analysis. The vertebral centra of S. acanthias undergo strain during in vivo volitional movements as well as in situ passive movements. Moreover, when isolated segments of vertebral column were tested during mechanical bending, we measured the same magnitudes of strain. These data support our hypothesis that vertebral column strain in lateral bending is not limited to the intervertebral joints. In histological sections, we found that the vertebral column of S. acanthias has an intracentral canal that is open and covered with a velum layer. An open intracentral canal may indicate that the centra are acting as tunics around some sections of a hydrostat, effectively stiffening the vertebral column. These data suggest that the entire vertebral column of sharks, both joints and centra, is mechanically engaged as a dynamic spring during locomotion.  相似文献   

12.
In radiological assessment of scoliosis, some prognostic value is given to vertebral rotation. An improved method for measuring vertebral rotation is introduced. It differs from the known methods by a specific selection of vertebral model parameters describing location of pedicles relative to the vertebral body. Vertebral model parameters have been determined from 150 axial X-rays of vertebral specimens. Application of measured parameters yields accuracy of about +/- 5 degrees in assessing vertebral rotation. Good agreement is found with parameters of six scoliotic vertebrae, investigated by CT-scans. A method for clinical presentation of measurement results is proposed.  相似文献   

13.
Computed tomography (CT) provides both anatomical and density information about tissues. Bone is segmented by raw images and Finite Element Method (FEM) voxel-based meshing technique is achieved by matching each CT voxel to a single finite element (FE). As a consequence of the automated model reconstruction, unstable elements – i.e. elements insufficiently anchored to the whole model and thus potentially involved in partial rigid body motion – can be generated, a crucial problem in obtaining consistent FE models, hindering mechanical analyses. Through the classification of instabilities on topological connections between elements, a numerical procedure is proposed in order to avoid unconstrained models.  相似文献   

14.
There is no generally accepted scientific theory for the causes of adolescent idiopathic scoliosis (AIS). As part of its mission to widen understanding of scoliosis etiology, the International Federated Body on Scoliosis Etiology (IBSE) introduced the electronic focus group (EFG) as a means of increasing debate on knowledge of important topics. This has been designated as an on-line Delphi discussion. The text for this debate was written by Dr Ian A Stokes. It evaluates the hypothesis that in progressive scoliosis vertebral body wedging during adolescent growth results from asymmetric muscular loading in a "vicious cycle" (vicious cycle hypothesis of pathogenesis) by affecting vertebral body growth plates (endplate physes). A frontal plane mathematical simulation tested whether the calculated loading asymmetry created by muscles in a scoliotic spine could explain the observed rate of scoliosis increase by measuring the vertebral growth modulation by altered compression. The model deals only with vertebral (not disc) wedging. It assumes that a pre-existing scoliosis curve initiates the mechanically-modulated alteration of vertebral body growth that in turn causes worsening of the scoliosis, while everything else is anatomically and physiologically 'normal' The results provide quantitative data consistent with the vicious cycle hypothesis. Dr Stokes' biomechanical research engenders controversy. A new speculative concept is proposed of vertebral symphyseal dysplasia with implications for Dr Stokes' research and the etiology of AIS. What is not controversial is the need to test this hypothesis using additional factors in his current model and in three-dimensional quantitative models that incorporate intervertebral discs and simulate thoracic as well as lumbar scoliosis. The growth modulation process in the vertebral body can be viewed as one type of the biologic phenomenon of mechanotransduction. In certain connective tissues this involves the effects of mechanical strain on chondrocytic metabolism a possible target for novel therapeutic intervention.  相似文献   

15.
Considerable differences in spinal morphology have been noted between humans and other hominoids. Although comparative analyses of the external morphology of vertebrae have been performed, much less is known regarding variations in internal morphology (density) and biomechanical performance among humans and closely related non-human primates. In the current study we utilize density calibrated computed tomography images of thoracic vertebral bodies from hominoids (n = 8-15 per species, human specimens 20-40 years of age) to obtain estimates of vertebral bone strength in axial compression and anteroposterior bending and to determine how estimates of strength scale with animal body mass. Our biomechanical analysis suggests that the strength of thoracic vertebral bodies is related to body mass (M) through power law relationships (y ∝ Mb) in which the exponent b is 0.89 (reduced major axis) for prediction of axial compressive strength and is equal to 1.89 (reduced major axis) for prediction of bending strength. No differences in the relationship between body mass and strength were observed among hominoids. However, thoracic vertebrae from humans were found to be disproportionately larger in terms of vertebral length (distance between cranial and caudal endplates) and overall vertebral body volume (p < 0.05). Additionally, vertebral bodies from humans were significantly less dense than in other hominoids (p < 0.05). We suggest that reduced density in human vertebral bodies is a result of a systemic increase in porosity of cancellous bone in humans, while increased vertebral body volume and length are a result of functional adaptation during growth resulting in a vertebral bone structure that is just as strong, relative to body mass, as in other hominoids.  相似文献   

16.
Given the diversity of vertebral morphologies among fishes, it is tempting to propose causal links between axial morphology and body curvature. We propose that shape and size of the vertebrae, intervertebral joints, and the body will more accurately predict differences in body curvature during swimming rather than a single meristic such as total vertebral number alone. We examined the correlation between morphological features and maximum body curvature seen during routine turns in five species of shark: Triakis semifasciata, Heterodontus francisci, Chiloscyllium plagiosum, Chiloscyllium punctatum, and Hemiscyllium ocellatum. We quantified overall body curvature using three different metrics. From a separate group of size‐matched individuals, we measured 16 morphological features from precaudal vertebrae and the body. As predicted, a larger pool of morphological features yielded a more robust prediction of maximal body curvature than vertebral number alone. Stepwise linear regression showed that up to 11 features were significant predictors of the three measures of body curvature, yielding highly significant multiple regressions with r2 values of 0.523, 0.537, and 0.584. The second moment of area of the centrum was always the best predictor, followed by either centrum length or transverse height. Ranking as the fifth most important variable in three different models, the body's total length, fineness ratio, and width were the most important non‐vertebral morphologies. Without considering the effects of muscle activity, these correlations suggest a dominant role for the vertebral column in providing the passive mechanical properties of the body that control, in part, body curvature during swimming. J. Morphol., 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

17.
Every year, 500,000 osteoporotic vertebral compression fractures occur in Europe. Quantitative computed tomography (QCT)-based finite element (FE) voxel models predict ultimate force whether they simulate vertebral bodies embedded in polymethylmethacrylate (PMMA) or vertebral sections with both endplates removed. To assess the effect of endplate removal in those predictions, non-linear FE analyses of QCT-based voxel models of human vertebral bodies were performed. High resolution pQCT images of 11 human lumbar vertebrae without posterior elements were coarsened to clinical resolution and bone volume fraction was used to determine the elastic, plastic and damage behavior of bone tissue. Three model boundary conditions (BCs) were chosen: the endplates were cropped (BC1, BC2) or voxel layers were added on the intact vertebrae to mimic embedding (BC3). For BC1 and BC3, the bottom nodes were fully constrained and the top nodes were constrained transversely while both node sets were freed transversely for BC2. Axial displacement was prescribed to the top nodes. In each model, we compared ultimate force and damage distribution during post-yield loading. The results showed that ultimate forces obtained with BC3 correlated perfectly with those computed with BC1 (R(2)=0.9988) and BC2 (R(2)=0.9987), but were in average 3.4% lower and 6% higher respectively. Moreover, good correlation of damage distribution calculated for BC3 was found with those of BC1 (R(2)=0.92) and BC2 (R(2)=0.73). This study demonstrated that voxel models of vertebral sections provide the same ultimate forces and damage distributions as embedded vertebral bodies, but with less preprocessing and computing time required.  相似文献   

18.
Whole-body stiffness in fishes has important consequences for swimming mode, speed and efficiency, but the contribution of vertebral column stiffness to whole-body stiffness is unclear. In our opinion, this lack of clarity is due in part to the lack of studies that have measured both in vitro mechanical properties of the vertebral column as well as in vivo vertebral kinematics in the same species. Some lack of clarity may also come from real variation in the mechanical role of the vertebral column across species. Previous studies, based on either mechanics or kinematics alone, suggest species-specific variation in vertebral column locomotor function that ranges from highly stiff regimes that contribute greatly to whole-body stiffness, and potentially act as a spring, to highly compliant regimes that only prohibit excessive flexion of the intervertebral joints. We review data collected in combined investigations of both mechanics and kinematics of three species, Myxine glutinosa, Acipenser transmontanus, and Morone saxatilis, to illustrate how mechanical testing within the context of the in vivo kinematics more clearly distinguishes the role of the vertebral column in each species. In addition, we identify species for which kinematic data are available, but mechanical data are lacking. We encourage further investigation of these species to fill these mechanical data gaps. Finally, we hope these future combined analyses will identify certain morphological, mechanical, or kinematic parameters that might be associated with certain vertebral column functional regimes with respect to body stiffness.  相似文献   

19.
Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.  相似文献   

20.
Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird-line archosaurs. Beyond providing a comprehensive view of vertebral pneumaticity in a non-avian coelurosaur, this study demonstrates the utility and need of CT imaging for further clarifying the early evolutionary history of postcranial pneumaticity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号