首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The previous models for predicting the forces acting on a needle during insertion into very soft organs (such as, e.g. brain) relied on oversimplifying assumptions of linear elasticity and specific experimentally derived functions for determining needle-tissue interactions. In this contribution, we propose a more general approach in which the needle forces are determined directly from the equations of continuum mechanics using fully non-linear finite element procedures that account for large deformations (geometric non-linearity) and non-linear stress-strain relationship (material non-linearity) of soft tissues. We applied these procedures to model needle insertion into a swine brain using the constitutive properties determined from the experiments on tissue samples obtained from the same brain (i.e. the subject-specific constitutive properties were used). We focused on the insertion phase preceding puncture of the brain meninges and obtained a very accurate prediction of the needle force. This demonstrates the utility of non-linear finite element procedures in patient-specific modelling of needle insertion into soft organs such as, e.g. brain.  相似文献   

2.
Although the age-related loss of bone quality has been implicated in bone fragility, a mechanistic understanding of the relationship is necessary for developing diagnostic and treatment modalities in the elderly population at risk of fracture. In this study, a finite element based cohesive zone model is developed and applied to human cortical bone in order to capture the experimentally shown rising crack growth behavior and age-related loss of bone toughness. The cohesive model developed here is based on a traction–crack opening displacement relationship representing the fracture processes in the vicinity of a propagating crack. The traction–displacement curve, defining the cohesive model, is composed of ascending and descending branches that incorporate material softening and nonlinearity. The results obtained indicate that, in contrast to initiation toughness, the finite element simulations of crack growth in compact tension (CT) specimens successfully capture the rising R-curve (propagation toughness) behavior and the age-related loss of bone toughness. In close correspondence with the experimentally observed decrease of 14–15% per decade, the finite element simulation results show a decrease of 13% in the R-curve slope per decade. The success of the simulations is a result of the ability of cohesive models to capture and predict the parameters related to bone fracture by representing the physical processes occurring in the vicinity of a propagating crack. These results illustrate that fracture mechanisms in the process zone control bone toughness and any modification to these would cause age-related toughness loss.  相似文献   

3.
Simplified material models are commonly used in computational simulation of biological soft tissue as an approximation of the complicated material response and to minimize computational resources. However, the simulation of complex loadings, such as long-duration tissue swelling, necessitates complex models that are not easy to formulate. This paper strives to offer the updated Lagrangian formulation comprehensive procedure of various non-linear material models for the application of finite element analysis of biological soft tissues including a definition of the Cauchy stress and the spatial tangential stiffness. The relationships between water content, osmotic pressure, ionic concentration and the pore pressure stress of the tissue are discussed with the merits of these models and their applications.  相似文献   

4.
In this study, we investigate the effects of modelling choices for the brain–skull interface (layers of tissues between the brain and skull that determine boundary conditions for the brain) and the constitutive model of brain parenchyma on the brain responses under violent impact as predicted using computational biomechanics model. We used the head/brain model from Total HUman Model for Safety (THUMS)—extensively validated finite element model of the human body that has been applied in numerous injury biomechanics studies. The computations were conducted using a well-established nonlinear explicit dynamics finite element code LS-DYNA. We employed four approaches for modelling the brain–skull interface and four constitutive models for the brain tissue in the numerical simulations of the experiments on post-mortem human subjects exposed to violent impacts reported in the literature. The brain–skull interface models included direct representation of the brain meninges and cerebrospinal fluid, outer brain surface rigidly attached to the skull, frictionless sliding contact between the brain and skull, and a layer of spring-type cohesive elements between the brain and skull. We considered Ogden hyperviscoelastic, Mooney–Rivlin hyperviscoelastic, neo–Hookean hyperviscoelastic and linear viscoelastic constitutive models of the brain tissue. Our study indicates that the predicted deformations within the brain and related brain injury criteria are strongly affected by both the approach of modelling the brain–skull interface and the constitutive model of the brain parenchyma tissues. The results suggest that accurate prediction of deformations within the brain and risk of brain injury due to violent impact using computational biomechanics models may require representation of the meninges and subarachnoidal space with cerebrospinal fluid in the model and application of hyperviscoelastic (preferably Ogden-type) constitutive model for the brain tissue.  相似文献   

5.
The recent studies have shown that long-term bisphosphonate use may result in a number of mechanical alterations in the bone tissue including a reduction in compositional heterogeneity and an increase in microcrack density. There are limited number of experimental and computational studies in the literature that evaluated how these modifications affect crack initiation and propagation in cortical bone. Therefore, in this study, the entire crack growth process including initiation and propagation was simulated at the microscale by using the cohesive extended finite element method. Models with homogeneous and heterogeneous material properties (represented at the microscale capturing the variability in material property values and their distribution) as well as different microcrack density and microstructure were compared. The results showed that initiation fracture resistance was higher in models with homogeneous material properties compared to heterogeneous ones, whereas an opposite trend was observed in propagation fracture resistance. The increase in material heterogeneity level up to 10 different material property sets increased the propagation fracture resistance beyond which a decrease was observed while still remaining higher than the homogeneous material distribution. The simulation results also showed that the total osteonal area influenced crack propagation and the local osteonal area near the initial crack affected the crack initiation behavior. In addition, the initiation fracture resistance was higher in models representing bisphosphonate treated bone (low material heterogeneity, high microcrack density) compared to untreated bone models (high material heterogeneity, low microcrack density), whereas an opposite trend was observed at later stages of crack growth. In summary, the results demonstrated that tissue material heterogeneity, microstructure, and microcrack density influenced crack initiation and propagation differently. The findings also elucidate how possible modifications in material heterogeneity and microcrack density due to bisphosphonate treatment may influence the initiation and propagation fracture resistance of cortical bone.  相似文献   

6.
The mechanical properties of human soft tissue are crucial for impact biomechanics, rehabilitation engineering, and surgical simulation. Validation of these constitutive models using human data remains challenging and often requires the use of non-invasive imaging and inverse finite element (FE) analysis. Post-processing data from imaging methods such as tagged magnetic resonance imaging (MRI) can be challenging. Digital image correlation (DIC), however, is a relatively straightforward imaging method. DIC has been used in the past to study the planar and superficial properties of soft tissue and excised soft tissue layers. However, DIC has not been used to non-invasive study of the bulk properties of human soft tissue in vivo. Thus, the goal of this study was to assess the use of DIC in combination with FE modelling to determine the bulk material properties of human soft tissue. Indentation experiments were performed on a silicone gel soft tissue phantom. A two camera DIC setup was then used to record the 3D surface deformation. The experiment was then simulated using a FE model. The gel was modelled as Neo-Hookean hyperelastic, and the material parameters were determined by minimising the error between the experimental and FE data. The iterative FE analysis determined material parameters (μ=1.80 kPa, K=2999 kPa) that were in close agreement with parameters derived independently from regression to uniaxial compression tests (μ=1.71 kPa, K=2857 kPa). Furthermore the FE model was capable of reproducing the experimental indentor force as well as the surface deformation found (R2=0.81). It was therefore concluded that a two camera DIC configuration combined with FE modelling can be used to determine the bulk mechanical properties of materials that can be represented using hyperelastic Neo-Hookean constitutive laws.  相似文献   

7.
This study describes the development of a constitutive law for the modelling of the periodontal ligament (PDL) and its practical implementation into a commercial finite element code. The constitutive equations encompass the essential mechanical features of this biological soft tissue: non-linear behaviour, large deformations, anisotropy, distinct behaviour in tension and compression and the fibrous characteristics. The approach is based on the theory of continuum fibre-reinforced composites at finite strain where a compressible transversely isotropic hyperelastic strain energy function is defined. This strain energy density function is further split into volumetric and deviatoric contributions separating the bulk and shear responses of the material. Explicit expressions of the stress tensors in the material and spatial configurations are first established followed by original expressions of the elasticity tensors in the material and spatial configurations. As a simple application of the constitutive model, two finite element analyses simulating the mechanical behaviour of the PDL are performed. The results highlight the significance of integrating the fibrous architecture of the PDL as this feature is shown to be responsible for the complex strain distribution observed.  相似文献   

8.
This study describes the development of a constitutive law for the modelling of the periodontal ligament (PDL) and its practical implementation into a commercial finite element code. The constitutive equations encompass the essential mechanical features of this biological soft tissue: non-linear behaviour, large deformations, anisotropy, distinct behaviour in tension and compression and the fibrous characteristics. The approach is based on the theory of continuum fibre-reinforced composites at finite strain where a compressible transversely isotropic hyperelastic strain energy function is defined. This strain energy density function is further split into volumetric and deviatoric contributions separating the bulk and shear responses of the material. Explicit expressions of the stress tensors in the material and spatial configurations are first established followed by original expressions of the elasticity tensors in the material and spatial configurations. As a simple application of the constitutive model, two finite element analyses simulating the mechanical behaviour of the PDL are performed. The results highlight the significance of integrating the fibrous architecture of the PDL as this feature is shown to be responsible for the complex strain distribution observed.  相似文献   

9.
目的:重建OSAHS患者上气道和软腭的流固耦合有限元模型,研究OSAHS患者上气道及软腭气流动力学特征,为进一步探讨OSAHS的的发病机制奠定基础。方法:对一名中度OSAHS患者的上气道及周围组织进行MRI扫描,将以DICOM格式存储的扫描数据导入Mimics15.0软件中进行预处理,得到上气道和软腭的模型;再利用逆向工程软件Geomagic Studio 2013建立了2 mm气道壁;然后在3-D重建软件NX中,生成气道壁和气道以及软腭之间的组合模型;最后将该组合模型导入ANSYS Workbench13.0软件中,通过网格划分、定义材料属性、设定模型的边界条件操作建立了上气道和软腭的流固耦合有限元模型。结果:利用Mimics、Ansys等软件建立了完整的上气道和软腭的流固耦合有限元模型。共得到气道:2806835单元和529281个节点;气道壁:2304348单元和3487609个节点;软腭:131855单元和204784个节点。结论:本研究建立的上气道及软腭的流固耦合有限元模型符合人体的生物力学特点,为下一步的数值模拟实验提供了一个更真实、可靠的模型。  相似文献   

10.
The paper gives a bibliographical review of the finite element modelling and simulations in cardiovascular mechanics and cardiology from the theoretical as well as practical points of views. The bibliography lists references to papers, conference proceedings and theses/dissertations that were published between 1993 and 2004. At the end of this paper, more than 890 references are given dealing with subjects as: Cardiovascular soft tissue modelling; material properties; mechanisms of cardiovascular components; blood flow; artificial components; cardiac diseases examination; surgery; and other topics.  相似文献   

11.
In this work we examined the determination of soft tissue parameters via tissue aspiration experiments and inverse finite element characterisation. An aspiration tube was put against the target tissue. The deformation of the tissue inside the tube caused by weak suction was tracked with a video based system. A strain energy function was employed to model the elastic behaviour of soft tissue and viscoelasticity was accounted for by means of a quasi-linear viscoelastic formulation. Friction between the aspiration tube and the aspirated tissue was included in the model. Based on the assumed material model, an optimal set of material parameters was found, in order to best fit the experimental data obtained from ex-vivo experiments on pig kidney cortex. The inverse method resulted in robust determination of the unknown material parameters.  相似文献   

12.
This paper presents a finite element formulation suitable for large-strain modeling of biological tissues and uses this formulation to implement an accurate finite element model for mitral valve leaflet tissue. First, an experimentally derived strain energy function is obtained from literature. This function is implemented in finite elements using the mixed pressure-displacement formulation. A modification is made to aid in maintaining positive definiteness of the stiffness matrix at low strains. The numerical implementation is shown to be accurate in representing the analytical model of material behavior. The mixed formulation is useful for modeling of soft biological tissues in general, and the model presented here is applicable to finite element simulation of mitral valve mechanics.  相似文献   

13.
The risk of fracture increases with age due to the decline of bone mass and bone quality. One of the age-related changes in bone quality occurs through the formation and accumulation of advanced glycation end-products (AGEs) due to non-enzymatic glycation (NEG). However as a number of other changes including increased porosity occur with age and affect bone fragility, the relative contribution of AGEs on the fracture resistance of aging bone is unknown. Using a high-resolution nonlinear finite element model that incorporate cohesive elements and micro-computed tomography-based 3d meshes, we investigated the contribution of AGEs and cortical porosity on the fracture toughness of human bone. The results show that NEG caused a 52% reduction in propagation fracture toughness (R-curve slope). The combined effects of porosity and AGEs resulted in an 88% reduction in propagation toughness. These findings are consistent with previous experimental results. The model captured the age-related changes in the R-curve toughening by incorporating bone quantity and bone quality changes, and these simulations demonstrate the ability of the cohesive models to account for the irreversible dynamic crack growth processes affected by the changes in post-yield material behavior. By decoupling the matrix-level effects due to NEG and intracortical porosity, we are able to directly determine the effects of NEG on fracture toughness. The outcome of this study suggests that it may be important to include the age-related changes in the material level properties by using finite element analysis towards the prediction of fracture risk.  相似文献   

14.
While including the cement-bone interface of complete cemented hip reconstructions is crucial to correctly capture their response, its modelling is often overly simplified. In this study, the mechanical mixed-mode response of the cement-bone interface is investigated, taking into account the effects of the well-defined microstructure that characterises the interface. Computed tomography-based plain strain finite element analyses models of the cement-bone interface are built and loaded in multiple directions. Periodic boundaries are considered and the failure of the cement and bone fractions by cracking of the bulk components are included. The results compare favourably with experimental observations. Surprisingly, the analyses reveal that under shear loading no failure occurs and considerable normal compression is generated to prevent interface dilation. Reaction forces, crack patterns and stress fields provide more insight into the mixed-mode failure process. Moreover, the cement-bone interface analyses provide details which can serve as a basis for the development of a cohesive law.  相似文献   

15.
We hypothesize that both compression and elongation stress–strain data should be considered for modeling and simulation of soft tissue indentation. Uniaxial stress–strain data were obtained from in vitro loading experiments of porcine liver tissue. An axisymmetric finite element model was used to simulate liver tissue indentation with tissue material represented by hyperelastic models. The material parameters were derived from uniaxial stress–strain data of compressions, elongations, and combined compression and elongation of porcine liver samples. in vitro indentation tests were used to validate the finite element simulation. Stress–strain data from the simulation with material parameters derived from the combined compression and elongation data match the experimental data best. This is due to its better ability in modeling 3D deformation since the behavior of biological soft tissue under indentation is affected by both its compressive and tensile characteristics. The combined logarithmic and polynomial model is somewhat better than the 5-constant Mooney–Rivlin model as the constitutive model for this indentation simulation.  相似文献   

16.
High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element models that account for microcomputed tomography-measured tissue modulus variability more accurately predict the apparent stiffness of cancellous bone than homogeneous models, and to examine the sensitivity of an inhomogeneous model to the degree of tissue property variability. We tested five different material cases in finite element models of ten cancellous cubes in simulated uniaxial compression. Three of these cases were inhomogeneous and two were homogeneous. Four of these cases were unique to each specimen, and the remaining case had the same tissue modulus for all specimens. Results from all simulations were compared with measured elastic moduli from previous experiments. Tissue modulus variability for the most accurate of the three inhomogeneous models was then artificially increased to simulate the effects of non-linear CT-attenuation-modulus relationships. Uniqueness of individual models was more critical for model accuracy than level of inhomogeneity. Both homogeneous and inhomogeneous models that were unique to each specimen had at least 8% greater explanatory power for apparent modulus than models that applied the same material properties to all specimens. The explanatory power for apparent modulus of models with a tissue modulus coefficient of variation (COV) range of 21-31% was 13% greater than homogeneous models (COV=0). The results of this study indicate that inhomogenous finite element models that have tissue moduli unique to each specimen more accurately predict the elastic behavior of cancellous cubic specimens than models that have common tissue moduli between all specimens.  相似文献   

17.
18.
19.
The paper gives a bibliographical review of the finite element modelling and simulations in cardiovascular mechanics and cardiology from the theoretical as well as practical points of views. The bibliography lists references to papers, conference proceedings and theses/dissertations that were published between 1993 and 2004. At the end of this paper, more than 890 references are given dealing with subjects as: Cardiovascular soft tissue modelling; material properties; mechanisms of cardiovascular components; blood flow; artificial components; cardiac diseases examination; surgery; and other topics.  相似文献   

20.
The numerical method of finite elements (FE) is a powerful tool for analysing stresses and strains in the human body. One area of increasing interest is the skeletal musculature. This study evaluated modelling of skeletal muscle tissue using a combination of passive non-linear, viscoelastic solid elements and active Hill-type truss elements, the super-positioned muscle finite element (SMFE). The performance of the combined materials and elements was evaluated for eccentric motions by simulating a tensile experiment from a published study on a stimulated rabbit muscle including three different strain rates. It was also evaluated for isometric and concentric contractions. The resulting stress-strain curves had the same overall pattern as the experiments, with the main limitation being sensitivity to the active force-length relation. It was concluded that the SMFE could model active and passive muscle tissue at constant rate elongations for strains below failure, as well as isometric and concentric contractions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号