首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
The temporomandibular (TM) joint is one of the most used joints in the human body, and any defect in this joint has a significant influence on quality of life. The objective of this study was to create a parametric numerical finite element (FE) analysis to compare the effect of surgical techniques used for total TM joint replacement implantation on loading the TM joint on the other side. Our hypothesis is that for the optimal function of all total TM joint replacements used in clinical practice it is crucial to devise a minimally invasive surgical technique, whereby there is minimum resection of masticatory muscles. This factor is more important than the design of the usually used total TM joint replacements. The extent of muscle resection influences the mechanical loading of the whole system. In the parametric FE analyses, the magnitude of the TM joint loading was compared for four different ranges of muscle resections during bite, using an anatomical model. The results obtained from all FE analyses support our hypothesis that an increasing extent of the muscle resection increased the magnitude of the TM joint overloading on the opposite side. The magnitude of the TM joint overloading increased depending on the muscle resection to 235% for bite on an incisor and up to 491% for bite on molars. Our study leads to a recommendation that muscle resection be minimised during replacement implantation and to a proposal that the attachment of the condylar part of the TM joint replacement be modified.  相似文献   

2.
A two-dimensional, five-muscle model was used to determine the degree of precision required for accurate calculation of temporomandibular joint force magnitude and direction. The sensitivity of the calculations to each variable were assessed by incrementing each variable through its presumed biological range and were expressed as rate of change in the joint force per unit change in each variable. Sensitivity of the calculations to variables depends upon both bite force direction and bite position. The bite force direction with maximum precision for joint force magnitude produced minimal precision for joint force direction. The accuracy needed for each muscle force varied greatly. The effect of error for each muscle parameter depended upon the magnitude, direction, and moment arm length of the muscle force relative to those of the resultant muscle force. If each of the five muscle forces was known to the nearest 1% of total muscle force magnitude, 1 degree of muscle force direction, and 1 mm of moment arm length, temporomandibular joint force magnitude could be calculated to the nearest 4 kg and joint force direction to the nearest 7 degrees. It is not known whether this precision for the muscle forces is possible.  相似文献   

3.
4.
The effect of measurement errors on quantitative calculation of temporomandibular joint reaction force was investigated in a two-dimensional, two-muscle model. A computer program using the model incremented the magnitude of the bite force and muscle forces and the lengths of their moment arms, and calculated the joint reaction force at each increment. Computation of the joint reaction force is most sensitive to the relative lengths of the bite force and muscle forces moment arms. Absolute values for each muscle force are not required and errors in the magnitudes of the muscle forces have only a minor effect on calculation of the total joint reaction force.  相似文献   

5.

Functional heterogeneity is a skeletal muscle’s ability to generate diverse force vectors through localised motor unit (MU) recruitment. Existing 3D macroscopic continuum-mechanical finite element (FE) muscle models neglect MU anatomy and recruit muscle volume simultaneously, making them unsuitable for studying functional heterogeneity. Here, we develop a method to incorporate MU anatomy and information in 3D models. Virtual fibres in the muscle are grouped into MUs via a novel “virtual innervation” technique, which can control the units’ size, shape, position, and overlap. The discrete MU anatomy is then mapped to the FE mesh via statistical averaging, resulting in a volumetric MU distribution. Mesh dependency is investigated using a 2D idealised model and revealed that the amount of MU overlap is inversely proportional to mesh dependency. Simultaneous recruitment of a MU’s volume implies that action potentials (AP) propagate instantaneously. A 3D idealised model is used to verify this assumption, revealing that neglecting AP propagation results in a slightly less-steady force, advanced in time by approximately 20 ms, at the tendons. Lastly, the method is applied to a 3D, anatomically realistic model of the masticatory system to demonstrate the functional heterogeneity of masseter muscles in producing bite force. We found that the MU anatomy significantly affected bite force direction compared to bite force magnitude. MU position was much more efficacious in bringing about bite force changes than MU overlap. These results highlight the relevance of MU anatomy to muscle function and joint force, particularly for muscles with complex neuromuscular architecture.

  相似文献   

6.
In the prediction of bone remodelling processes after total hip replacement (THR), modelling of the subject-specific geometry is now state-of-the-art. In this study, we demonstrate that inclusion of subject-specific loading conditions drastically influences the calculated stress distribution, and hence influences the correlation between calculated stress distributions and changes in bone mineral density (BMD) after THR.For two patients who received cementless THR, personalized finite element (FE) models of the proximal femur were generated representing the pre- and post-operative geometry. FE analyses were performed by imposing subject-specific three-dimensional hip joint contact forces as well as muscle forces calculated based on gait analysis data. Average values of the von Mises stress were calculated for relevant zones of the proximal femur. Subsequently, the load cases were interchanged and the effect on the stress distribution was evaluated. Finally, the subject-specific stress distribution was correlated to the changes in BMD at 3 and 6 months after THR.We found subject-specific differences in the stress distribution induced by specific loading conditions, as interchanging of the loading also interchanged the patterns of the stress distribution. The correlation between the calculated stress distribution and the changes in BMD were affected by the two-dimensional nature of the BMD measurement.Our results confirm the hypothesis that inclusion of subject-specific hip contact forces and muscle forces drastically influences the stress distribution in the proximal femur. In addition to patient-specific geometry, inclusion of patient-specific loading is, therefore, essential to obtain accurate input for the analysis of stress distribution after THR.  相似文献   

7.
Combined finite-element and rigid-body analysis of human jaw joint dynamics   总被引:1,自引:0,他引:1  
The jaw joint plays a crucial role in human mastication. It acts as a guidance for jaw movements and as a fulcrum for force generation. The joint is subjected to loading which causes tensions and deformations in its cartilaginous structures. These are assumed to be a major determinant for development, maintenance and also degeneration of the joint. To analyze the distribution of tensions and deformations in the cartilaginous structures of the jaw joint during jaw movement, a dynamical model of the human masticatory system has been constructed. Its movements are controlled by muscle activation. The articular cartilage layers and articular disc were included as finite-element (FE) models. As this combination of rigid-body and FE modeling had not been applied to musculoskeletal systems yet, its benefits and limitations were assessed by simulating both unloaded and loaded jaw movements. It was demonstrated that joint loads increase with muscle activation, irrespective of the external loads. With increasing joint load, the size of the stressed area of the articular surfaces was enlarged, whereas the peak stresses were much less affected. The results suggest that the articular disc enables distribution of local contact stresses over a much wider area of the very incongruent articular surfaces by transforming compressive principal stress into shear stress.  相似文献   

8.
Sphenodon, a lizard-like reptile, is the only living representative of a group that was once widespread at the time of the dinosaurs. Unique jaw mechanics incorporate crushing and shearing motions to breakdown food, but during this process excessive loading could cause damage to the jaw joints and teeth. In mammals like ourselves, feedback from mechanoreceptors within the periodontal ligament surrounding the teeth is thought to modulate muscle activity and thereby minimise such damage. However, Sphenodon and many other tetrapods lack the periodontal ligament and must rely on alternative control mechanisms during biting. Here we assess whether mechanoreceptors in the jaw joints could provide feedback to control muscle activity levels during biting. We investigate the relationship between joint, bite, and muscle forces using a multibody computer model of the skull and neck of Sphenodon. When feedback from the jaw joints is included in the model, predictions agree well with experimental studies, where the activity of the balancing side muscles reduces to maintain equal and minimal joint forces. When necessary, higher, but asymmetric, joint forces associated with higher bite forces were achievable, but these are likely to occur infrequently during normal food processing. Under maximum bite forces associated with symmetric maximal muscle activation, peak balancing side joint forces were more than double those of the working side. These findings are consistent with the hypothesis that feedback similar to that used in the simulation is present in Sphenodon.  相似文献   

9.
Children who exhibit gait deviations often present a range of bone deformities, particularly at the proximal femur. Altered gait may affect bone growth and lead to deformities by exerting abnormal stresses on the developing bones. The objective of this study was to calculate variations in the hip joint contact forces with different gait patterns. Muscle and hip joint contact forces of four children with different walking characteristics were calculated using an inverse dynamic analysis and a static optimisation algorithm. Kinematic and kinetic analyses were based on a generic musculoskeletal model scaled down to accommodate the dimensions of each child. Results showed that for all the children with altered gaits both the orientation and magnitude of the hip joint contact force deviated from normal. The child with the most severe gait deviations had hip joint contact forces 30% greater than normal, most likely due to the increase in muscle forces required to sustain his crouched stance. Determining how altered gait affects joint loading may help in planning treatment strategies to preserve correct loading on the bone from a young age.  相似文献   

10.
A three-dimensional mathematical model of the human masticatory system, containing 16 muscle forces and two joint reaction forces, is described. The model allows simulation of static bite forces and concomitant joint reaction forces for various bite point locations and mandibular positions. The system parameters for the model were obtained from a cadaver head. Maximum possible bite forces were computed using optimization techniques; the optimization criterion we used was the minimizing of the relative activity of the most active muscle. The model predicts that at each specific bite point, bite forces can be generated in a wide range of directions, and that the magnitude of the maximum bite force depends on its direction. The relationship between bite force direction and its maximum magnitude depends on bite point location and mandibular position. In general, the direction of the largest possible bite force does not coincide with the direction perpendicular to the occlusal plane.  相似文献   

11.
1IntroductionAseptic loosening is a major clinical probleminterfering with long term success of arthroplasty inhumans.When this occurs,the stem will migrate withinthe cortical bone.The migration of the stem after hiparthroplasty is an unavoidable phenomenon and is one ofthe major cause of late aseptic loosening of the hiparthroplasty[1-5].Many factors,such as cement mantle performance,stem type and surface finish,cementing and surgerytechniques affect the subsidence or migration of thefemoral …  相似文献   

12.
The prevalence of musculoskeletal modeling studies investigating hip contact forces and the number of models used to conduct such investigations has increased in recent years. However, the consistency between models remain unknown and differences in model predicted hip contact forces between studies are difficult to distinguish from natural inter-individual differences. The purpose of this study was therefore to evaluate differences in hip joint contact forces during gait between four OpenSim models. These models included the generic models gait2392 and the Arnold Lower Limb Model, as well as the hip specific models hip2372 and London Lower Limb Model. Data from four individuals who have had a total hip replacement with instrumented hip implants performing slow, normal, and fast walking trials were taken from the HIP98 database to evaluate the various models effectiveness at estimating hip loads. Muscle forces were estimated using static optimization and hip contact forces were calculated using the JointReaction analysis in OpenSim. Results indicated that, for gait, the hip specific London Lower Limb Model consistently predicted peak push-off hip joint contact forces with lower magnitude and timing errors compared to the other models. Likewise, root mean square error values were lowest and correlation coefficients were highest for the London Lower Limb Model. These results suggest that the London Lower Limb Model is the most appropriate model for investigations focused on hip joint loading.  相似文献   

13.
The equine metacarpophalangeal (MCP) joint is frequently injured, especially by racehorses in training. Most injuries result from repetitive loading of the subchondral bone and articular cartilage rather than from acute events. The likelihood of injury is multi-factorial but the magnitude of mechanical loading and the number of loading cycles are believed to play an important role. Therefore, an important step in understanding injury is to determine the distribution of load across the articular surface during normal locomotion. A subject-specific finite-element model of the MCP joint was developed (including deformable cartilage, elastic ligaments, muscle forces and rigid representations of bone), evaluated against measurements obtained from cadaver experiments, and then loaded using data from gait experiments. The sensitivity of the model to force inputs, cartilage stiffness, and cartilage geometry was studied. The FE model predicted MCP joint torque and sesamoid bone flexion angles within 5% of experimental measurements. Muscle–tendon forces, joint loads and cartilage stresses all increased as locomotion speed increased from walking to trotting and finally cantering. Perturbations to muscle–tendon forces resulted in small changes in articular cartilage stresses, whereas variations in joint torque, cartilage geometry and stiffness produced much larger effects. Non-subject-specific cartilage geometry changed the magnitude and distribution of pressure and the von Mises stress markedly. The mean and peak cartilage stresses generally increased with an increase in cartilage stiffness. Areas of peak stress correlated qualitatively with sites of common injury, suggesting that further modelling work may elucidate the types of loading that precede joint injury and may assist in the development of techniques for injury mitigation.  相似文献   

14.
In musculoskeletal models of the human temporomandibular joint (TMJ), muscles are typically represented by force vectors that connect approximate muscle origin and insertion centroids (centroid-to-centroid force vectors). This simplification assumes equivalent moment arms and muscle lengths for all fibers within a muscle even with complex geometry and may result in inaccurate estimations of muscle force and joint loading. The objectives of this study were to quantify the three-dimensional (3D) human TMJ muscle attachment morphometry and examine its impact on TMJ mechanics. 3D muscle attachment surfaces of temporalis, masseter, lateral pterygoid, and medial pterygoid muscles of human cadaveric heads were generated by co-registering measured attachment boundaries with underlying skull models created from cone-beam computerized tomography (CBCT) images. A bounding box technique was used to quantify 3D muscle attachment size, shape, location, and orientation. Musculoskeletal models of the mandible were then developed and validated to assess the impact of 3D muscle attachment morphometry on joint loading during jaw maximal open-close. The 3D morphometry revealed that muscle lengths and moment arms of temporalis and masseter muscles varied substantially among muscle fibers. The values calculated from the centroid-to-centroid model were significantly different from those calculated using the ‘Distributed model’, which considered crucial 3D muscle attachment morphometry. Consequently, joint loading was underestimated by more than 50% in the centroid-to-centroid model. Therefore, it is necessary to consider 3D muscle attachment morphometry, especially for muscles with broad attachments, in TMJ musculoskeletal models to precisely quantify the joint mechanical environment critical for understanding TMJ function and mechanobiology.  相似文献   

15.
Hip loading affects the development of hip osteoarthritis, bone remodelling and osseointegration of implants. In this study, we analyzed the effect of subject-specific modelling of hip geometry and hip joint centre (HJC) location on the quantification of hip joint moments, muscle moments and hip contact forces during gait, using musculoskeletal modelling, inverse dynamic analysis and static optimization. For 10 subjects, hip joint moments, muscle moments and hip loading in terms of magnitude and orientation were quantified using three different model types, each including a different amount of subject-specific detail: (1) a generic scaled musculoskeletal model, (2) a generic scaled musculoskeletal model with subject-specific hip geometry (femoral anteversion, neck-length and neck-shaft angle) and (3) a generic scaled musculoskeletal model with subject-specific hip geometry including HJC location. Subject-specific geometry and HJC location were derived from CT. Significant differences were found between the three model types in HJC location, hip flexion–extension moment and inclination angle of the total contact force in the frontal plane. No model agreement was found between the three model types for the calculation of contact forces in terms of magnitude and orientations, and muscle moments. Therefore, we suggest that personalized models with individualized hip joint geometry and HJC location should be used for the quantification of hip loading. For biomechanical analyses aiming to understand modified hip joint loading, and planning hip surgery in patients with osteoarthritis, the amount of subject-specific detail, related to bone geometry and joint centre location in the musculoskeletal models used, needs to be considered.  相似文献   

16.
The weakness of hip abductor muscles is related to lower-limb joint osteoarthritis, and joint overloading may increase the risk for disease progression. The relationship between muscle strength, structural joint deterioration and joint loading makes the latter an important parameter in the study of onset and follow-up of the disease. Since the relationship between hip abductor weakness and joint loading still remains an open question, the purpose of this study was to adopt a probabilistic modeling approach to give insights into how the weakness of hip abductor muscles, in the extent to which normal gait could be unaltered, affects ipsilateral joint contact forces. A generic musculoskeletal model was scaled to each healthy subject included in the study, and the maximum force-generating capacity of each hip abductor muscle in the model was perturbed to evaluate how all physiologically possible configurations of hip abductor weakness affected the joint contact forces during walking. In general, the muscular system was able to compensate for abductor weakness. The reduced force-generating capacity of the abductor muscles affected joint contact forces to a mild extent, with 50th percentile mean differences up to 0.5 BW (maximum 1.7 BW). There were greater increases in the peak knee joint loads than in loads at the hip or ankle. Gluteus medius, particularly the anterior compartment, was the abductor muscle with the most influence on hip and knee loads. Further studies should assess if these increases in joint loading may affect initiation and progression of osteoarthritis.  相似文献   

17.
A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning.  相似文献   

18.
The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions.  相似文献   

19.
Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses.  相似文献   

20.
Rotator cuff tear (RCT) in older adults may cause decreased muscle forces and disrupt the force balance at the glenohumeral joint, compromising joint stability. Our objective was to identify how increased RCT severity affects glenohumeral joint loading and muscle activation patterns using a computational model. Muscle volume measurements were used to scale a nominal upper limb model’s peak isometric muscle forces to represent force-generating characteristics of an average older adult male. Increased RCT severity was represented by systematically decreasing peak isometric muscle forces of supraspinatus, infraspinatus, and subscapularis. Five static postures in both scapular and frontal planes were evaluated. Results revealed that in both scapular and frontal planes, the peak glenohumeral joint contact force magnitude remained relatively consistent across increased RCT severity (average 1.5% and −4.2% change, respectively), and a relative balance of the transverse force couple is maintained even in massive RCT models. Predicted muscle activations of intact muscles, like teres minor, increased (average 5–30% and 4–17% in scapular and frontal planes, respectively) with greater RCT severity. This suggests that the system is prioritizing glenohumeral joint stability, even with severe RCT, and that unaffected muscles play a compensatory role to help stabilize the joint.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号