1.
BACKGROUND: The use of artificial bone analogs in biomechanical testing of orthopaedic fracture fixation devices has increased, particularly due to the recent development of commercially available femurs such as the third generation composite femur that closely reproduce the bulk mechanical behavior of human cadaveric and/or fresh whole bone. The purpose of this investigation was to measure bone screw pullout forces in composite femurs and determine whether results are comparable to cadaver data from previous literature. METHOD OF APPROACH: The pullout strengths of 3.5 and 4.5 mm standard bicortical screws inserted into synthetic third generation composite femurs were measured and compared to existing adult human cadaveric and animal data from the literature. RESULTS: For 3.5 mm screws, the measured extraction shear stress in synthetic femurs (23.70-33.99 MPa) was in the range of adult human femurs and tibias (24.4-38.8 MPa). For 4.5 mm screws, the measured values in synthetic femurs (26.04-34.76 MPa) were also similar to adult human specimens (15.9-38.9 MPa). Synthetic femur results for extraction stress showed no statistically significant site-to-site effect for 3.5 and 4.5 mm screws, with one exception. Overall, the 4.5 mm screws showed statistically higher stress required for extraction than 3.5 mm screws. CONCLUSIONS: The third generation composite femurs provide a satisfactory biomechanical analog to human long-bones at the screw-bone interface. However, it is not known whether these femurs perform similarly to human bone during physiological screw "toggling."  相似文献   

2.

Objective

This biomechanical study compared the torsional strength and stiffness of a locking compression plate with all locking versus nonlocking screws and examined the effect of placing a locking unicortical or nonlocking bicortical screw nearest the fracture gap in a synthetic bone model.

Results

Synthetic bone models simulating a diaphyseal fracture without anatomic reduction were tested using four screw configurations: all bicortical locking (ABL), all bicortical nonlocking (ABN), a hybrid construct with a bicortical nonlocking screw nearest the fracture gap (BN), and a unicortical locking screw placed nearest the fracture gap (UL). Torsional stiffness, rotation and torque at failure were compared via ANOVA and post hoc pairwise comparisons (p < 0.05). ABN and BN had the highest stiffness (p < 0.01) with ABL greater than UL (p < 0.01). Rotation at failure was greatest for ABL (p < 0.01) with UL greater than ABN (p < 0.05). Unicortical locking screws nearest the fracture gap decreased stiffness, without significantly affecting torque or rotation at failure. Construct stiffness was found to exist in a very narrow range of 0.9–1.2 N m/deg with standard deviations of 0.1 N m/deg in all cases. The results of this study support the use of nonlocking screws in a hybrid construct to increase torsional stiffness.
  相似文献   

3.
In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no "gold standard" treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 ± 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 ± 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p ≥ 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 ± 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic "spiral" pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture.  相似文献   

4.

Background

The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures.

Methods

Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed.

Results

Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001). When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P≤0.0207). Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture.

Conclusions

Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.  相似文献   

5.
The choice of an internal fixation system for maxillofacial surgery is made difficult because of lack of information with respect to functional load. This study attempted to clarify some of the controversy with respect to maxillofacial use of these implants. Maximal compressive force to torque values were measured in standardized bone thicknesses of 1, 2, 3, and 4 mm. The screws tested were pretapped AO 1.5-, 2.0-, 2.7-, and 3.5-mm rescue screws and self-tapping Luhr, Champy, and AO 1.5- and 2.0-mm screws. Ten measurements were made for each screw type/bone thickness combination using a piezoelectric washer and torque screwdriver. It was apparent that for 1- and 2-mm bone thicknesses the use of self-tapping screws resulted in the highest compression values. In 3- and 4-mm bone thicknesses, pretapped screws offered the highest compression values. As expected, self-tapping screws had the highest torque values on insertion owing to torque loss in cutting the screw threads. The 2.7-mm screw offered no advantage over the 2.0-mm screws in 1- and 2-mm bone thicknesses but resulted in higher compression values in 3- and 4-mm bone thicknesses.  相似文献   

6.
Concept and development of an orthotropic FE model of the proximal femur   总被引:2,自引:0,他引:2  
PURPOSE: In contrast to many isotropic finite-element (FE) models of the femur in literature, it was the object of our study to develop an orthotropic FE "model femur" to realistically simulate three-dimensional bone remodelling. METHODS: The three-dimensional geometry of the proximal femur was reconstructed by CT scans of a pair of cadaveric femurs at equal distances of 2mm. These three-dimensional CT models were implemented into an FE simulation tool. Well-known "density-determined" bony material properties (Young's modulus; Poisson's ratio; ultimate strength in pressure, tension and torsion; shear modulus) were assigned to each FE of the same "CT-density-characterized" volumetric group.In order to fix the principal directions of stiffness in FE areas with the same "density characterization", the cadaveric femurs were cut in 2mm slices in frontal (left femur) and sagittal plane (right femur). Each femoral slice was scanned into a computer-based image processing system. On these images, the principal directions of stiffness of cancellous and cortical bone were determined manually using the orientation of the trabecular structures and the Haversian system. Finally, these geometric data were matched with the "CT-density characterized" three-dimensional femur model. In addition, the time and density-dependent adaptive behaviour of bone remodelling was taken into account by implementation of Carter's criterion. RESULTS: In the constructed "model femur", each FE is characterized by the principal directions of the stiffness and the "CT-density-determined" material properties of cortical and cancellous bone. Thus, on the basis of anatomic data a three-dimensional FE simulation reference model of the proximal femur was realized considering orthotropic conditions of bone behaviour. CONCLUSIONS: With the orthotropic "model femur", the fundamental basis has been formed to realize realistic simulations of the dynamical processes of bone remodelling under different loading conditions or operative procedures (osteotomies, total hip replacements, etc).  相似文献   

7.
While locking plate fixation is becoming increasingly popular for complex and osteoporotic fractures, for many indications compression plating remains the standard choice. This study compares the mechanical behaviour of the more recent locking compression plate (LCP) device, with the traditional dynamic compression plates (DCPs) in bone of varying quality using finite element modelling. The bone properties considered include orthotropy, inhomogeneity, cortical thinning and periosteal apposition associated with osteoporosis. The effect of preloads induced by compression plating was included in the models. Two different fracture scenarios were modelled: one with complete reduction and one with a fracture gap. The results show that the preload arising in DCPs results in large principal strains in the bone all around the perimeter of the screw hole, whereas for LCPs large principal strains occur primarily on the side of the screw proximal to the load. The strains within the bone produced by the two screw types are similar in healthy bone with a reduced fracture gap; however, the DCP produces much larger strains in osteoporotic bone. In the presence of a fracture gap, the DCP results in a considerably larger region with high tensile strains and a slightly smaller region with high compressive strains. These findings provide a biomechanical basis for the reported improved performance of locking plates in poorer bone quality.  相似文献   

8.
《Journal of biomechanics》2014,47(16):3898-3902
Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males <80 years with good bone quality. Since most hip fractures occur in old women with fragile bones, concern is raised regarding the use of standard 4GCFs in biomechanical experiments. In this study the stability of hip fracture fixations in 4GCFs was compared to human cadaver femurs (HCFs) selected to represent patients with hip fractures.Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements.Median (95% CI) head fragment migration was 0.8 mm (0.4 to 1.1) in the 4GCF group versus 2.2 mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers.To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs.  相似文献   

9.
The mechanical properties of certain bone screws have been examined. The torque developed during insertion of 4 mm (5/32″) non-self-tapping and self-tapping screws and their holding power in bone have been measured. Screws should be inserted into tapped holes using a torque limiting device if failures of screws at insertion are to be prevented. The construction of a surgical torque limiting screwdriver is given.  相似文献   

10.

Objectives

To evaluate the postoperative stability of osteoporotic distal radius fractures fixed with distal locking screws with different length.

Methods

A comminuted extra-articular dorsally unstable distal radius fracture, treated with volar locking plate system, was created. The 18 specimens were randomized into 3 groups based on distal locked screws with different length: Group A had unicortical screws with 50% length to the dorsal cortex. Group B had unicortical screws with 75% length to the dorsal cortex. Group C had bicortical screws. Axial compression and bending loads were imposed on the models before and after cycling testing as well as load to clinical and catastrophic failure.

Results

Minimum change in stiffness was observed before and after fatigue for all groups. The final stiffness to bending forces was statistically similar in all groups, but stiffness to axial compression was statistically significant different: Group A approached significance with respect to groups B and C (P = 0.017, 0.009), whereas stiffness in group B and C was statistically similar (P = 0.93). Load to clinical failure was significantly less for group A (456.54±78.59 N) compared with groups B (580.24±73.85 N) and C (591.07±38.40 N). Load to catastrophic failure was statistically similar between groups, but mean values for Group A were 18% less than means for Group C.

Conclusions

The volar locking plate system fixed with unicortical locking screws with at least 75% length not only produced early stability for osteoporotic distal radius fractures, but also avoided extensor tendon complications due to dorsal screw protrusion.  相似文献   

11.
目的:探讨股骨上端骨折,以动力加压髋螺钉进行骨固定治疗,骨折愈合后,取出动力加压髋螺钉以后的股骨上段与完整的股骨上段的生物力学特性相比较,为临床内固定取出术后功能锻炼的强度提供量化依据。方法:收集8具新鲜尸体股骨标本进行实验应力分析,分别测定完整股骨上段和动力加压髋螺钉取出后股骨上段的力学特性改变。结果:动力加压髋螺钉取出术后股骨上段的力学特性与完整股骨上段的力学特性相比有显著的差异(P<0.01)。结论:股骨上端骨折如果以动力加压髋螺钉为治疗手段,在骨折愈合取出内固定后,功能锻炼只能控制在慢速步行水平,不能进行奔跑、跳跃等活动,以防止再骨折等并发症的发生。  相似文献   

12.

Background

Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP).

Materials and Methods

Nine standard composite femurs were acquired, divided into three groups and fixed with LP (n?=?3), ABP (n?=?3) and DCSP (n?=?3). The fracture was modeled by a 20?mm gap created at the subtrochanteric region to experimentally study the biomechanical response of each implant under both static and dynamic axial loading paradigms. To confirm the experimental findings and to understand the critical interactions at the boundaries, the synthetic femur/implant systems were numerically analyzed by constructing hierarchical finite element models with nonlinear hyperelastic properties. The predictions from the analyses were then compared against the experimental measurements to demonstrate the validity of each numeric model, and to characterize the internal load distribution in the femur and load bearing properties of each implant.

Results

The average measurements indicated that the constructs with ABP, DCPS and LP respectively had overall stiffness values of 70.9, 110.2 and 131.4?N/mm, and exhibited reversible deformations of 12.4, 4.9 and 4.1?mm when the applied dynamic load was 400?N and plastic deformations of 11.3, 2.4 and 1.4?mm when the load was 1000?N. The corresponding peak cyclic loads to failure were 1100, 1167 and 1600?N. The errors between the displacements measured experimentally or predicted by the nonlinear hierarchical hyperelastic model were less than 18?%. In the implanted femur heads, the principal stresses were spatially heterogeneous for ABP and DCSP but more homogenous for LP, meaning LP had lower stress concentrations.

Conclusion

When fixed with the LP implant, the synthetic femur model of the subtrochancteric fracture consistently exceeds in the key biomechanical measures of stability and durability. These capabilities suggest increased resistance to fatigue and failure, which are highly desirable features expected of functional implants and hence make the LP implant potentially a viable alternative to the conventional ABP or DCSP in the treatment of subtrochancteric femur fractures for the betterment of clinical outcome.  相似文献   

13.

Background

Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction.

Methods

Three types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups.

Results

Equipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05).

Conclusions

Our study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs with or without interlocking mechanisms, actual clinical trial deserves to be further investigated in future studies.  相似文献   

14.
Flexible fixation or the so-called ‘biological fixation’ has been shown to encourage the formation of fracture callus, leading to better healing outcomes. However, the nature of the relationship between the degree of mechanical stability provided by a flexible fixation and the optimal healing outcomes has not been fully understood. In this study, we have developed a validated quantitative model to predict how cells in fracture callus might respond to change in their mechanical microenvironment due to different configurations of locking compression plate (LCP) in clinical practice, particularly in the early stage of healing. The model predicts that increasing flexibility of the LCP by changing the bone–plate distance (BPD) or the plate working length (WL) could enhance interfragmentary strain in the presence of a relatively large gap size (>3 mm). Furthermore, conventional LCP normally results in asymmetric tissue development during early stage of callus formation, and the increase of BPD or WL is insufficient to alleviate this problem.  相似文献   

15.
The mechanical behavior of human femurs has been described in the literature with regard to torsion and tension but only as independent measurements. However, in this study, human femurs were subjected to torsion to determine if a simultaneous axial tensile load was generated. Fresh frozen human femurs (n=25) were harvested and stripped of soft tissue. Each femur was mounted rigidly in a specially designed test jig and remained at a fixed axial length during all experiments. Femurs were subjected to external and internal rotation applied at a constant angulation rate of 0.1 deg/s to a maximum torque of 12?N?m. Applied torque and generated axial tension were monitored simultaneously. Outcome measurements were extracted from torsion-versus-tension graphs. There was a strong relationship between applied torsion and the resulting tension for external rotation tests (torsion/tension ratio=551.7±283.8?mm, R(2)=0.83±0.20, n=25), internal rotation tests (torsion/tension ratio=495.3±233.1?mm, R(2)=0.87±0.17, n=24), left femurs (torsion/tension ratio=542.2±262.4?mm, R(2)=0.88±0.13, n=24), and right femurs (torsion/tension ratio=506.7±260.0?mm, R(2)=0.82±0.22, n=25). No statistically significant differences were found for external versus internal rotation groups or for left versus right femurs when comparing torsion/tension ratios (p=0.85) or R(2) values (p=0.54). A strongly coupled linear relationship between torsion and tension for human femurs was exhibited. This suggests an interplay between these two factors during activities of daily living and injury processes.  相似文献   

16.
This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen were selected to evaluate the feasibility for strain acquisition over a range of callus properties. The HS specimen was 147 times stiffer in compression than the LS specimen. ESPI captured continuous strain distributions on both specimens. Peak strain was located adjacent to cortical boundaries in the osteotomy gap. In response to 5N compression, peak compressive strain of 5.8% in the LS specimen was over two orders of magnitude higher than peak compressive strain of 0.013% in the HS specimen. In conclusion, ESPI-based strain acquisition enables reproducible quantification of strain distributions on callus cross-sections. Such measurements may support validation of computational models and evaluation of experimental results in fracture healing research.  相似文献   

17.
目的:探讨不同植入物内固定治疗四肢创伤骨折后骨不连的临床疗效。方法:选择我科2010年2月~2013年2月四肢创伤骨折后骨不连患者38例,按照随机数表法将38例患者随机分为两组,分别为LC-DCP组以及LCP组,每组各19例,观察两组患者的平均手术持续时间、骨折临床愈合时间、X线骨痂评分以及并发症。结果:LC-DCP组平均手术持续时间为(134.73±12.91)min,LCP组为(129.54±14.87)min,两组比较不存在统计学差异(P0.05)。LC-DCP组患者平均骨折临床愈合时间为(3.94±0.83)月,LCP组为(3.81±0.69)月,两组间不存在统计学显著性差异(P0.05)。LC-DCP组患者X线骨痂评价标准平均评分值为(2.73±0.51)分,LCP组为(2.86±0.49)分,两组间差异不存在统计学意义(P0.05)。结论:两种钢板联合植骨治疗四肢创伤骨折后骨不连均能够取得良好的治疗效果,均可以作为治疗四肢创伤骨折后骨不连患者的有效方法。  相似文献   

18.
The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding.  相似文献   

19.
A mutation in LRP5 (low-density lipoprotein receptor-related protein 5) has been shown to increase bone mass and density in humans and animals. Transgenic mice expressing the LRP5 mutation (G171V) demonstrate an increase in bone mass as compared to non-transgenic (NTG) littermates. This study evaluated LRP5 gene and gender-related influences on the structural and biomechanical strength properties of trabecular and cortical bone in femurs and vertebrae (L5) of 17-week-old mice. Micro-computed tomography was used to evaluate the trabecular bone structure of distal femurs and vertebrae ex vivo. Mechanical testing of the trabecular bone in the distal femur was done to determine biomechanical strength. Differences due to genotype and gender were tested using two-way ANOVA at a significance level of p<0.05. Trabecular bone structural parameters (BV/TV, trabecular thickness, number, etc.) at the distal femur, femoral neck, and vertebral body sites were greater in the transgenic as compared to the NTG mice. In addition, vertebral cortical thickness and trabecular strength parameters (ultimate and yield loads, stiffness, ultimate and yield stresses) in the distal femur were greater in the transgenic mice as compared to NTG. The increasing trends of cortical thickness were also noted in the transgenic mice as compared to NTG. Within LRP5 (G171V) mutant mice, there were significant gender-related differences in some of the trabecular bone structural parameters at all the sites (distal femur, femoral neck, and vertebral body). However, unlike trabecular structural parameters, the gender-specific differences were not found in the trabecular strength of LRP5 transgenic mice. In summary, these findings suggest that the LRP5 (G171V) mutation results in greater trabecular bone structure and strength at both the distal femurs and vertebral bodies as compared to NTG. In addition, only the trabecular structure parameters were affected by gender within the LRP5 (G171V) mutation.  相似文献   

20.
目的:评价用锁定加压钢板行微创技术治疗老年性股骨远端骨折的临床疗效。方法:自2012年1月到2015年6月间,我院用锁定加压钢板行微创技术治疗27例60岁以上老年性股骨远端骨折患者(其中1例为双侧),通过观察患者伤口愈合情况、骨折愈合情况及相关并发症,并采用Kolmert评分标准评价其临床效果。结果:本组27例患者均获得随访,其中1例患者(单侧)在术后25 d死亡,其余病例随访6-30月,平均14.7月,术后切口有1例延迟愈合,余均一期愈合,骨折在末次随访均骨性愈合,未见骨折移位、内固定物失效、骨折畸形愈合、骨折不愈合等不良并发症,根据Kolmert评分标准,优10例,良13例,可3例,差1例,优良率为85%。结论:锁定加压钢板行微创技术治疗老年性股骨远端骨折可达到固定牢固、能早期功能练习、术后并发症少、术后效果满意的疗效。  相似文献   