首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Benzyl alcohol is commonly used as an antibacterial agent in a variety of pharmaceutical formulations. Several fatalities in neonates have been linked to benzyl alcohol poisoning. Most methods for measuring benzyl alcohol concentrations in serum utilize direct extraction followed by high-performance liquid chromatography. We describe here a novel derivatization of benzyl alcohol using perfluorooctanoyl chloride after extraction from human serum for analysis by gas chromatography–mass spectrometry (GC–MS). The derivative was eluted at a significantly higher temperature respective to underivatized molecule and the method was free from interferences from more volatile components in serum and hemolyzed specimens. Another advantage of this derivatization technique is the conversion of low-molecular-mass benzyl alcohol (Mr 108) to a high-molecular-mass derivative (Mr 504). The positive identification of benzyl alcohol can be achieved by observing a distinct molecular ion at m/z 504 as well as the base peak at m/z 91. Quantitation of benzyl alcohol in human serum can easily be achieved by using 3,4-dimethylphenol as an internal standard. The within run and between run precisions (using serum standard of benzyl alcohol: 25 mg/l) were 2.7% (mean=24.1, S.D.=0.66 mg/l, n=8) and 4.2% (mean=24.3, S.D.=1.03 mg/l, n=8), respectively. The assay was linear for the serum benzyl alcohol concentrations of 2 mg/l to 200 mg/l and the detection limit was 0.1 mg/l. We observed no carry-over (memory effect) problem in our assay as when 2 μl ethyl acetate was injected into the GC–MS system after analyzing serum specimens containing 200 mg/l of benzyl alcohol, we observed no peak for either benzyl alcohol or the internal standard in the total ion chromatogram.  相似文献   

2.
Urinary phenol is analyzed widely to determine benzene exposure in humans. Most methods utilize direct measurements of phenols after extraction from urine using gas chromatography or high-performance liquid chromatography. We describe a novel derivatization of urinary phenols using 4-carbethoxyhexafluorobutyryl chloride after extraction from urine and subsequent analysis by gas chromatography-mass spectrometry. The derivative elutes at significantly higher temperature than phenol and the method is free from interferences from more volatile components in urine. We also observed excellent chromatographic properties of these derivatives. In addition, we observed strong molecular ions for the 4-carbethoxyhexafluoro butyryl derivative of phenol (m/z 344), p-cresol (m/z 358) and the internal standard 3,4-dimethylphenol (m/z 372) and other characteristic ions in the electron ionization, thus aiding in unambiguous identification of these compounds. The protonated molecular ions (m/z 373 for derivatized phenol, m/z 359 for derivatized p-cresol and m/z 373 for the internal standard) were the base peaks (relative abundance 100%) in the chemical ionization, although other secondary peaks were less abundant. The assay is linear for phenol concentration of 1–100 mg/l. The within-run and between-run precisions were 4.8% ( ) and 8.1% ( ) respectively, and the detection limit was 0.5 mg/l.  相似文献   

3.
A highly sensitive ion monitoring method for the determination of valproic acid in saliva and in serum has been developed based on the gas chromatographic—mass spectrometric analysis of the tert.-butyldimethylsilyl derivatives. Extraction methods are simple and the techniques for derivatization are rapid and convenient. Selected ion monitoring was carried out using electron ionization conditions and a common ion m/z 201 (M+ − 57) present in valproic acid and the internal standard octanoic acid. The lower limit of sensitivity that has acceptable precision for assay purposes is 0.1 mg/l based on a 200-μl sample size. The ion monitoring method (derivatized) was compared to a gas chromatographic method (underivatized) for serum valproate assays and found to be essentially identical.The assay methodology was used in a kinetic study of valproic acid in two normal subjects. Saliva levels of drug were found to give reasonably good correlations with serum total and with serum free concentrations of drug in both individuals.  相似文献   

4.
Lamotrigine (lamictal) is a new anticonvulsant drug recently approved by the FDA for clinical use. Therapeutic monitoring of lamotrigine is useful for patient management (therapeutic range 1–4 μg/ml). Here we describe a gas chromatography–mass spectrometric identification and quantitation of lamotrigine after extraction from human serum and derivatization. Lamotrigine was extracted from alkaline serum with chloroform and derivatized with N-methyl-N-(tert.- butyldimethysilyl) trifluoroacetamide containing 2% tert.-butyldimethylchlorosilane. Oxazepam-d5 was used as an internal standard. The tert.-butyldimethylsilyl derivative of lamotrigine showed distinct molecular ions at m/z 483 and 485 as well as other peaks at m/z 426, 370 and 334 for unambiguous identification. The base peak was observed at m/z 199. Similarly, the tert.-butyldimethysilyl derivative of oxazepam-d5 showed molecular ions at m/z 519 and 521 along with other characteristic peaks at m/z 462, 376 and 318. For the analysis of lamotrigine, the mass spectrometer was operated in the selective ion monitoring mode. The within-run and between-run precisions were 4.3% (mean=3.01, S.D.=0.13 μg/ml) and 5.1% (mean=2.93, S.D.=0.15 μg/ml), respectively at a serum lamotrigine concentration of 3.0 μg/ml. The within-run and between-run precisions were 8.2% (mean=0.49, S.D.=0.04 μg/ml) and 10.6% (mean=0.47, S.D.=0.05 μg/ml), respectively at a serum lamotrigine concentration of 0.5 μg/ml. The assay was linear for serum lamotrigine concentrations of 0.5–20 μg/ml. The detection limit was 0.25 μg/ml. The assay was free from interferences from common tricyclic antidepressants, benzodiazepines, other common anticonvulsants, salicylate and acetaminophen.  相似文献   

5.
Albuterol is a β2-adrenergic agonist commonly used as a bronchdilator for the treatment of patients with asthma. We have developed an assay to determine plasma levels as low as 50 pg/ml of albuterol by gas chromatography-mass spectrometry (GC-MS). This assay utilizes isotopically labeled albuterol ([13C]albuterol) as an internal standard. In this assay albuterol and the internal standard are recovered from 1 ml of plasma using solid-phase extraction. The samples are then derivatized to trimethylsilyl ethers using N,O-bis(trimethylsilyl)trifluoro-acetamide with 1% trimethylchlorosilane. The samples are then analyzed by GC-MS with selected-ion monitoring (SIM) for the ions m/z 369.15 and 370.15. The method has been validated for a concentration range of 50–10000 pg/ml in plasma.  相似文献   

6.
A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC–APCI–MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 μg/l, the absolute recovery was above 80% at concentration level of 10 to 100 μg/l. The method tested linear in the range from 1 to 1000 μg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa™) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).  相似文献   

7.
A rapid and selective assay of morphine and its 3- and 6-glucuronides in serum, based on high-performance liquid chromatography-electrospray mass spectrometry has been developed. The analytes and the internal standard, codeine or naltrexone, were subjected to solid-phase extraction, using ethyl solid-phase extraction columns, prior to chromatography. A reversed-phase column and a gradient mobile phase consisting of water and methanol were used. The mass spectrometer was operated in the selected-ion monitoring mode. The following ions were used: m/z 286 for morphine, m/z 300 for codeine, m/z 342 for naltrexone, and m/z 462 for morphine 3- and 6-glucuronides. The limit of quantitation observed with this method was 10 ng/ml morphine, 50 ng/ml morphine-6-glucuronide and 100 ng/ml morphine-3-glucuronide. The present method proved useful for the determination of serum levels of the parent drug and its metabolites in pain patients, heroin addicts and in morphine-treated mice.  相似文献   

8.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

9.
A rapid and simple method is presented for the determination of vigabatrin enantiomers in human serum by high-performance liquid chromatography. Serum is deproteinized with trichloroacetic acid and aliquots of the supernatant are precolumn derivatized with o-phthaldialdehyde and N-acetyl- -cysteine, resulting in the formation of diastereomeric isoindoles. Separation was achieved on a Spherisorb 3ODS2 column using a gradient solvent program and the column eluent is monitored using fluorescence detection. -Homoarginine was used as an internal standard. Within-day precisions (C.V.; n=8) were 2.8 and 1.1%, respectively, for the (R)-(−)- and (S)-(+)-enantiomer in serum containing 15.4 mg/l (RS)-vigabatrin. The method was linear in the 0–45 mg/l range for both enantiomers and the minimum quantitation limit was 0.20 mg/l for (R)-(−)-vigabatrin and 0.14 mg/l for (S)-(+)-vigabatrin. No interferences were found from commonly co-administered antiepileptic drugs and from endogenous amino acids. The method is suitable for routine therapeutic drug monitoring and for pharmacokinetic studies.  相似文献   

10.
A simple, reliable and sensitive gas chromatographic–mass spectrometric method was devised to determine the level of mannitol in various human brain tissues obtained at autopsy. Mannitol was extracted with 10% trichloroacetic acid solution which effectively precipitated brain tissues. The supernatant was washed with tert.-butyl methyl ether to remove other organic compounds and to neutralize the aqueous solution. Mannitol was then derivatized with 1-butaneboronic acid and subjected to GC–MS. Erythritol was used as an internal standard. For quantitation, selected ion monitoring with m/z 127 and 253 for mannitol and m/z 127 for internal standard were used. Calibration curves were linear in concentration range from 0.2 to 20 μg/0.1 g and correlation coefficients exceeded 0.99. The lower detection limit of mannitol in distilled water was 1 ng/0.1 g. Mannitol was detected in control brain tissues, as a biological compound, at a level of 50 ng/0.1 g. The precision of this method was examined with use of two different concentrations, 2 and 20 μg/0.1 g, and the relative standard deviation ranged from 0.8 to 8.3%. We used this method to determine mannitol in brain tissues from an autopsied individual who had been clinically diagnosed as being brain dead. Cardiac arrest occurred 4 days later.  相似文献   

11.
Enzymatic hydrolysis with β‐glucuronidase/sulfatase was used for the enantioselective determination of N‐hydroxymexiletine glucuronide in plasma for pharmacokinetic studies. N‐Hydroxymexiletine glucuronide was determined as the quantity of mexiletine released by hydrolysis (difference between the enantiomeric concentrations of mexiletine obtained with and without hydrolysis). Plasma samples (100 μl) were treated at pH 5.0 with 10 mg of the enzyme (Limpet Acetone Powder type I) for 16 hr at 37°C and extracted at pH 10.4 with diisopropyl ether. Chiral mexiletine discrimination was obtained by reaction with o‐phthalaldehyde/N‐acetyl‐L ‐cysteine, separation of the resulting diastereomers on a C‐18 reversed‐phase column with a mobile phase of methanol–0.05 N acetate buffer, pH 5.5 (6.5:3.5, v/v), and fluorescence detection (λex 350 nm, λem 455 nm). The performance characteristics for the enantioselective analysis of mexiletine preceded by enzymatic hydrolysis were recovery ∼90%, quantification limit 1 ng/ml, and linearity up to 1000 ng/ml plasma for both enantiomers. The coefficients of variation obtained in the study of intra‐ and inter‐day precision were respectively 5% and 7% for both enantiomers. The assay was shown to be suitable for a pharmacokinetic study performed in a patient with the arrhythmic form of chronic Chagas' heart disease treated with 200 mg t.i.d. of racemic mexiletine hydrochloride. The high sensitivity of the method allows analysis of only 100 μl plasma. Chirality 11:85–90, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

12.
A rapid and economical high-performance liquid chromatographic assay is described for norfloxacin in serum. Samples (100 μl) containing N-ethylnorfloxacin as the internal standard were extracted into 1 ml of chloroform. Chromatography was performed at 30°C on a 40×3.2 mm I.D. C18 guard cartridge (3 μm spherical particles) using a mobile phase of 11% (v/v) acetonitrile in 0.01 M phosphate buffer (pH 2.5) containing 0.001 M triethylamine, and pumped at 1 ml/min. Detection was at 279 nm. The retention times of norfloxacin and internal standard were 1.9 and 2.9 min, respectively. Calibration curves were linear (r>0.999) from 0.1 mg/l to at least 2.0 mg/l. Within-day and between-day precision (C.V.) were 8.6% or less, and accuracy was 5.3% or less. Absolute assay recovery of norfloxacin was over 70%.  相似文献   

13.
A procedure for the high-performance liquid chromatographic determination of tobramycin in serum is described using pre-column derivatisation with 1-fluoro-2,4-dinitrobenzene and subsequent chromatographic analysis on a reversed-phase column with ultraviolet detection. Gentamicin is used as the internal standard. The sensitivity is 0.5 mg/l with 50-μl samples. Precision, expressed as the coefficient of variation, is 3% or better in the concentration range 0.5–16 mg/l. The absolute recovery of tobramycin is 41%.The analyses of serum samples obtained in an in vivo experiment correlated well with the results from a microbiological assay. The influence of variation of derivatisation conditions and the implications for the reliability of the internal standardisation were studied. The 2,4-dinitrophenyl tobramycin derivative was synthesized and its structure was proved to be the fully derivatized tobramycin. Side-products of the derivatisation reaction were isolated.  相似文献   

14.
Employing high-performance liquid chromatography–electrospray mass spectrometry, we describe a new assay for monitoring 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase activity. Incubations were carried out with HMG-CoA reductase (rat liver), HMG-CoA and NADPH, and terminated by the addition of HCl. The reaction product, mevalonolactone, and internal standard, were extracted with ethyl acetate, dissolved in methanol, and analyzed by LC–MS. Using an isocratic mobile phase of 10% acetonitrile and 0.1% formic acid (flow-rate, 0.2 ml/min), the protonated molecules of mevalonolactone at m/z 131 and internal standard, β,β-dimethyl-γ-(hydroxymethyl)-γ-butyrolactone, at m/z 145, were detected using selected ion monitoring. The limit of detection was approximately 6.5 pg, and the limit of quantitation was approximately 16.3 pg. Extraction recovery was >90%. The relative standard deviations for intra- and inter-day assays were approximately 4.1±2.7 and 9.4±3.4%, respectively. Mevalonolactone was examined over a period of 3 days and found to be stable. Using this assay, lovastatin and mevastatin inhibited HMG-CoA reductase activity with IC50 values 0.24±0.02 and 2.16±0.31 μM, respectively. These methods offer some advantages over those reported previously which employ radiolabeled substrate and products, and should be useful in searching for compounds that could lower serum cholesterol or alter cell growth and differentiation.  相似文献   

15.
A method for the determination of dihydroetorphine hydrochloride, a powerful anaesthetic and analgesic drug, in biological fluids by GC-MS with selected-ion monitoring using etorphine as internal standard was established. Dihydroetorphine was extracted from human blood and urine with dichloromethane and then derivatized with N-heptafluorobutyrylimidazole after concentration to dryness. A dihydroetorphine monoheptafluorobutyl derivative was formed which showed good behavior on GC-MS with electronic-impact ionization. The main fragment, m/z 522, which is the base peak, was selected as the ion for quantitation and the corresponding ion, m/z 520, was selected for monitoring the internal standard, etorphine. The recoveries and coefficients of variation of the whole procedure were determined with five controlled dihydroetorphine-free urine and plasma samples spiked with different concentrations of dihydroetorphine. The concentration of dihydroetorphine for quantitation was in the range 1–20 ng/ml for urine and 2.5–250 ng/ml for plasma. The correlation coefficients of the standard curves are sufficient to determine the dihydroetorphine. The accuracy for quantitation of dihydroetorphine in urine and plasma is less than 10.6%.  相似文献   

16.
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans.  相似文献   

17.
An original method based upon high-performance liquid chromatography coupled to electrospray ionization mass spectrometry has been developed for corticosterone (B) quantification in human serum. After extraction by diethyl ether using triamcinolone (T) as an internal standard, solutes are separated on a C18 microbore column (250×1.0 mm, I.D.), using acetonitrile–water–formic acid (40:59.9:0.1, v/v/v) as the mobile phase (flow-rate 40 μl/min). Detection is performed on an API 1 single quadrupole mass spectrometer equipped with a ESI interface and operated in positive ionization mode. Corticosterone quantifications were realized by computing peak area ratios (B/T) of the serum extracts analyzed in SIM mode (m/z 347 and m/z 395 for B and T, respectively), and comparing them with the calibration curve (r=0.998).  相似文献   

18.
A sensitive and selective reversed-phase LC–ESI-MS method to quantitate perifosine in human plasma was developed and validated. Sample preparation utilized simple acetonitrile precipitation without an evaporation step. With a Develosil UG-30 column (10×4 mm I.D.), perifosine and the internal standard hexadecylphosphocholine were baseline separated at retention times of 2.2 and 1.1 min, respectively. The mobile phase consisted of eluent A, 95% 9 mM ammonium formate (pH 8) in acetonitrile–eluent B, 95% acetonitrile in 9 mM ammonium formate (pH 8) (A–B, 40:60, v/v), and the flow-rate was 0.5 ml/min. The detection utilized selected ion monitoring in the positive-mode at m/z 462.4 and 408.4 for the protonated molecular ions of perifosine and the internal standard, respectively. The lower limit of quantitation of perifosine was 4 ng/ml in human plasma, and good linearity was observed in the 4–2000 ng/ml range fitted by linear regression with 1/x weight. The total LC–MS run time was 5 min. The validated LC–MS assay was applied to measure perifosine plasma concentrations from patients enrolled on a phase I clinical trial for pharmacokinetic/pharmacodynamic analyses.  相似文献   

19.
A procedure for the high-performance liquid chromatographic determination of tobramycin in serum is described using pre-column derivatisation with 1-fluoro-2,4-dinitrobenzene and subsequent chromatographic analysis on a reversed-phase column with ultraviolet detection. Gentamicin is used as the internal standard. The sensitivity is 0.5 mg/l with 50-μl samples. Precision, expressed as the coefficient of variation, is 3% or better in the concentration range 0.5–16 mg/l. The absolute recovery of tobramycin is 41%.The analyses of serum samples obtained in an in vivo experiment correlated well with the results from a microbiological assay. The influence of variation of derivatisation conditions and the implications for the reliability of the internal standardisation were studied. The 2,4-dinitrophenyl tobramycin derivative was synthesized and its structure was proved to be the fully derivatized tobramycin. Side-products of the derivatisation reaction were isolated.  相似文献   

20.
A simple procedure based upon capillary column gas chromatography-mass spectrometry (GC—MS) is described for the detection and determination of isatin (indole-2,3-dione) in body fluids and tissues. After addition of 5-methylisatin as internal standard to urine or tissue homogenates, organic extracts are dried and derivatized successively with hydroxylamine hydrochloride and the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). The tert.-butyldimethylsilyl derivatives obtained show good GC—MS properties and allow quantification by selected-ion monitoring of m/z 333 (isatin) and m/z 347 (internal standard). Adult and newborn human urine output values lie in the ranges 0.4–3.2 mg/mmol of creatinine (5–30 mg per 24 h) and 0.002–0.518 mg/mmol of creatinine, respectively. There is a discontinuous regional distribution in rat tissues. The GC—MS properties of a number of derivatives formed by successive reaction of isatin with hydroxylamine hydrochloride (or methoxyaminehydrochloride or ethoxyamine hydrochloride) and MTBSTFA, bis(trimethylsilyl)trifluoroacetamide, pentafluoropropionic anhydride or pentafluorobenzyl bromide are also described.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号