首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
IntroductionThe aim of this work was to assess the role of 3T-MR spectroscopy (MRS) in the multi-parametric MRI evaluation of breast lesions, using a pattern-recognition based classification method.Methods291 patients (301 lesions, median 2.3 cm3) were enrolled in the study (age 18–85 y, mean 54.2 y). T1-TSE (TR/TE = 400/10 ms) and T2-STIR imaging (TR/TE = 5000/60 ms), dynamic-contrast-enhanced MRI (DCE-MRI), apparent diffusion coefficient (ADC) (b = 0–800 s/mm2), and single-voxel MRS (10 × 10 × 10 mm3, PRESS, TR/TE = 3000 ms/135 ms) were performed by means of a 3T scanner. MRS results were accepted if the FWHM of the water peak was ⩽45 Hz. Total choline (tCho) was considered detected if the signal-to-noise ratio (SNR) of the 3.2 ppm peak was ⩾2. A classifier-based analysis (support-vector-machines, SVM) was performed with 4-dimensional vectors including type of margin, DCE-MRI kinetic curve type, ADC mean value, and tCho SNR. A comparison with 3-dimensional vectors (without tCho SNR) was used to assess MRS impact on sensitivity, specificity, and positive-negative predictive values (PPV-NPV) for malignancy.Results228 lesions (180 malignant/48 benign) showed acceptable spectral quality. Comparison of classification results with histopathological examination of surgical specimens showed sensitivity = 93.7%, specificity = 84.9%, PPV = 95.2%, NPV = 81.5% without the inclusion of MRS in the SVM analysis. When MRS was included, the figures increased to 95.1%, 90.7%, 97.2%, and 85.0%, respectively.ConclusionsInclusion of 3T-MRS in the multi-parametric MRI evaluation of breast lesions improved the performance of the SVM-based classifier, showing a possible role of high-field MR spectroscopy in the differential diagnosis between benign and malignant breast lesions. Further research is however needed to confirm this initial evidence.  相似文献   

2.
Metal-on-metal hip resurfacing patients demonstrate hip biomechanics closer to normal in comparison to total hip arthroplasty during gait. However, it is not clear how symmetric is the gait of hip resurfacing patients. Biomechanical data of 12 unilateral metal-on-metal hip resurfacing participants were collected during gait at a mean time of 45 months (SD 24) after surgery. Ankle, knee, hip, pelvis and trunk kinematics and kinetics of both sides were measured with a motion and force-capture system. Principal component analysis and mean hypothesis’ tests were used to compare the operated and healthy sides. The operated side had prolonged ankle eversion angle during late stance and delayed increased ankle inversion angle during early swing (p = 0.008; effect size = 0.70), increased ankle inversion moment during late stance (p = 0.001; effect size = 0.78), increased knee adduction angle during swing (p = 0.044; effect size = 0.57), decreased knee abduction moment during stance (p = 0.05; effect size = 0.40), decreased hip range of motion in the sagittal plane (p = 0.046; effect size = 0.56), decreased range of hip abduction moment during stance (p = 0.02; effect size = 0.63), increased hip range of motion in the transverse plane (p = 0.02; effect size = 0.62), decreased hip internal rotation moment during the transition from loading response to midstance (p = 0.001; effect size = 0.81) and increased trunk ipsilateral lean (p = 0.03; effect size = 0.60). Therefore, hip resurfacing patients have some degree of asymmetry in long term, which may be related to hip weakness and decreased range of motion, to foot misalignments and to strategies implemented to reduce loading on the operated hip. Interventions such as muscle strengthening and stretching, insoles and gait feedback training may help improving symmetry following hip resurfacing.  相似文献   

3.
Current methods for measuring in vivo 3D muscle-tendon moment arms generally rely on the acquisition of magnetic resonance imaging (MRI) scans at multiple joint angles. However, for patients with musculoskeletal pathologies such as fixed contractures, moving a joint through its full range of motion is not always feasible. The purpose of this research was to develop a simple, but reliable in vivo 3D Achilles tendon moment arm (ATMA) technique from a single static MRI scan. To accomplish this, for nine healthy adults (5 males, 4 females), the geometry of a cylinder was fit to the 3D form of the talus dome, which was used to estimate the talocrural flexion/extension axis, and a fifth-order polynomial fit to the line of action of the Achilles tendon. The single static scan in vivo 3D ATMA estimates were compared to estimates obtained from the same subjects at the same ankle joint angles using a previously validated 3D dynamic MRI based in vivo ATMA measurement technique. The ATMA estimates from the single scan in vivo 3D method (52.5 mm ± 5.6) were in excellent agreement (ICC = 0.912) to the validated in vivo 3D method (51.5 mm ± 5.1). These data show reliable in vivo 3D ATMA can be obtained from a single MRI scan for healthy adult populations. The single scan, in vivo 3D ATMA technique provides researchers with a simple, but reliable method for obtaining subject-specific ATMAs for musculoskeletal modelling purposes.  相似文献   

4.
The aim of this work is the development of an improved formulation of the double threshold algorithm for sEMG onset–offset detection presented by Bonato and co-workers. The original formulation, which keeps the threshold fixed, suffers from performance degradation whenever the SNR changes during the analysis. The novel approach is designed to be adaptive to SNR changes in either burst or inter-burst zones of sEMG signals recorded in static and dynamic conditions. The detection parameters (i.e. detection and false alarm probabilities) are updated on the basis of an on-line estimation of the SNR. The proposed formulation has been assessed on both simulated and real sEMG data. For constant SNR the performance of the original formulation is confirmed (for SNR > 8 dB, bias and standard deviation less than 10 and 15 ms, respectively; detection percentage higher than 95%), while the novel implementation performs better with time-varying SNR (for SNR varying in the range 10–25 dB the standard approach detection percentage decreases at 50%). Detection on signals recorded during isometric contractions at different force levels confirms the performance on simulated signals (StD = 134 ms; FP = 22%, and StD = 42 ms; FP = 2%, respectively for standard and novel implementation calculated as average on five experimental trials). The pseudo real-time detection allowed by this formulation can be profitably exploited by biofeedback applications based on myoelectric information.  相似文献   

5.
ObjectiveTo investigate possible alterations in cord blood levels of adipokine nesfatin-1 (secreted by adipose tissue and pancreatic β-cells and implicated in glucose metabolism and insulin resistance), as well as insulin, in large (LGA) and appropriate for gestational age (AGA) pregnancies, granted that these groups differ in body fat mass and metabolic/endocrine mechanisms.Materials and methodsCord blood nesfatin-1 and insulin concentrations were prospectively measured in 40 LGA (9 born from diabetic and 31 from non-diabetic mothers) and 20 AGA singleton full-term infants as well as their mothers.ResultsCord blood nesfatin-1 concentrations were significantly lower in LGA compared to AGA neonates (b = ?0.206, SE 0.07, p = 0.005). However, cord blood nesfatin-1 concentrations were elevated in infants born from mothers with gestational diabetes mellitus (GDM), compared to those born from non-diabetic mothers, after controlling for group (b = 0.190, SE 0.10, p = 0.05). Finally, cord blood nesfatin-1 concentrations were lower in cases of vaginal delivery (b = 0.11, SE 0.05, p = 0.042). Insulin levels were significantly elevated, as customized centiles increased (b = 0.004, SE = 0.002, p = 0.016). No significant correlation was found between insulin and nesfatin-1 in maternal and umbilical cord levels.ConclusionsIn this study nesfatin-1 levels are decreased in LGA compared to AGA fetuses. Fetal nesfatin-1 concentrations are higher in cases of GDM and cord blood nesfatin-1 concentrations are lower in cases of vaginal delivery.  相似文献   

6.
Static, B-mode ultrasound is the most common method of measuring fascicle length in vivo. However, most forearm muscles have fascicles that are longer than the field-of-view of traditional ultrasound (T-US). As such, little work has been done to quantify in vivo forearm muscle architecture. The extended field-of-view ultrasound (EFOV-US) method, which fits together a sequence of B-mode images taken from a continuous ultrasound scan, facilitates direct measurements of longer, curved fascicles. Here, we test the validity and reliability of the EFOV-US method for obtaining fascicle lengths in the extensor carpi ulnaris (ECU). Fascicle lengths from images of the ECU captured in vivo with EFOV-US were compared to lengths from a well-established method, T-US. Images were collected in a joint posture that shortens the ECU such that entire fascicle lengths were captured within a single T-US image. Resulting measurements were not significantly different (p = 0.18); a Bland-Altman test demonstrated their agreement. A novice sonographer implemented EFOV-US in a phantom and in vivo on the ECU. The novice sonographer’s measurements from the ultrasound phantom indicate that the combined imaging and analysis method is valid (average error = 2.2 ± 1.3 mm) and the in vivo fascicle length measurements demonstrate excellent reliability (ICC = 0.97). To our knowledge, this is the first study to quantify in vivo fascicle lengths of the ECU using any method. The ability to define a muscle’s architecture in vivo using EFOV-US could lead to improvements in diagnosis, model development, surgery guidance, and rehabilitation techniques.  相似文献   

7.
Seasonal dynamics in the polyphenolic composition, antioxidant activity, and their relationships during plant development were evaluated for eastern teaberry (Gaultheria procumbens L.) leaves, a traditional herbal medicine of North American natives. With the complementary UHPLC-PDA-ESI-MS3, HPLC-PDA-fingerprint, Folin-Ciocalteau, and n-butanol/HCl assays of methanol-water (75:25, v/v) extracts, the dried leaf samples harvested monthly across the growing season under Polish climate conditions were found rich in structurally diverse polyphenols (149.2–210.7 mg/g DW) including the dominating salicylates (64.6–107.5 mg/g DW), proanthocyanidins (53.0–66.8 mg/g DW), and flavonoids (17.3–25.3 mg/g DW), and the accompanying chlorogenic acid isomers (2.4–4.4 mg/g DW) and simple phenolic acids (0.9–1.1 mg/g DW). Among 28 detected analytes, gaultherin (64.6–107.5 mg/g DW), miquelianin (14.6–21.1 mg/g DW), procyanidin A-type trimer (5.5–9.5 mg/g DW), and (–)-epicatechin (5.8–7.8 mg/g DW) were the most abundant. The phenolic levels and antioxidant activity parameters in the DPPH (EC50, 15.0–18.2 μg DW/mL; 0.95–1.16 mmol Trolox equivalents/g DW) and FRAP (2.3–3.4 mmol Fe 2+/g DW; 0.86–1.26 mmol Trolox equivalents/g DW) assays showed parallel seasonal trends with maxima in September and October. As the subsequent correlation studies confirmed the determinative impact of polyphenols on the leaf antioxidant activity and its seasonal fluctuations, the Fall season could be recommended as optimal for harvesting the plant material for medicinal purposes and cost-effective production of natural health products.  相似文献   

8.
《Cancer epidemiology》2014,38(3):286-290
PurposeThe group of luminal (Her2 negative) is distinguished from other subtypes of breast cancer. We aimed to produce a prognostic index specific for luminal (Her2 negative) subtype breast cancer that could assist clinical treatment.MethodsThe test set comprised 406 consecutive luminal (Her2 negative) breast cancer patients. The relationship of 11 clinicopathologic factors including survivin with the 5-year disease-free survival was analyzed.ResultsIn univariate analysis, TNM stage, surgery, tumor size, lymph node involvement, and survivin expression were prognostic factors. In multivariate analysis, tumor size [HR (95% CI): 1.98 (1.12–3.49), p = 0.019], the number of lymph node metastasis [HR (95% CI): 1.75 (1.33–2.29), p < 0.0001] and the expression of progesterone receptor [HR (95% CI): 0.58 (0.36–0.95), p = 0.029] can independently predict prognosis. Prognostic index (PI) was calculated as 0.68 × tumor size + 0.56 × the number of lymph node metastasis  0.54 × PR. According to the PI, patients were categorized into three groups: low, middle, and high risk group with the 5-year disease-free survival rates of 91.91%, 84.97% and 70.47%, respectively (P < 0.001). In the validation set, the luminal prognostic index (LPI) remained significant.ConclusionThe LPI may be a useful tool for evaluating the outcome of patients with luminal (Her-2 negative) breast cancer.  相似文献   

9.
The aims of this study were to examine group differences in muscle activation onset of the vastus medialis (VM) in relation to the vastus lateralis (VL) and pain level during stair ascent in females with patellofemoral pain (PFP) who maintain high and moderate levels of physical activity; to determine the association between physical activity level and muscle activation onset. Forty-three females with PFP and thirty-eight pain-free females were recruited and divided into four groups based on their level of physical activity: females with PFP (n = 26) and pain-free females (n = 26) who practiced a moderate level of physical activity and females with PFP (n = 17) and pain-free females (n = 12) who practiced an intense amount of physical activity. Participants were asked to ascend a seven-step staircase and the VM and VL activation onset was determined. Females with PFP who practiced high level of physical activity demonstrated delayed onset of VM (4.06 ms) compared to healthy females (−14.4 ms). Conversely, females with PFP who practiced moderate level of physical activity did not present VM delay (−2.48 ms) in comparison to healthy females (−9.89 ms). Furthermore, physical activity significantly correlated to the muscle activation onset difference (p = 0.005; R = 0.60). These findings may explain why controversial results regarding VM and VL muscle activation onset have been found.  相似文献   

10.
Although critical for effective human locomotion and posture, little data exists regarding the segmentation, architecture and contraction time of the human intrinsic foot muscles. To address this issue, the Abductor Hallucis (AH), Abductor Digiti Minimi (ADM), Flexor Digitorum Brevis (FDB) and Extensor Digitorum Brevis (EDB) were investigated utilizing a cadaveric dissection and a non-invasive whole muscle mechanomyographic (wMMG) technique. The segmental structure and architecture of formaldehyde-fixed foot specimens were determined in nine cadavers aged 60–80 years. The wMMG technique was used to determine the contraction time (Tc) of individual muscle segments, within each intrinsic foot muscle, in 12 volunteers of both genders aged between 19 and 24 years.While the pattern of segmentation and segmental –architecture (e.g. fibre length) and –Tc of individual muscle segments within the same muscle were similar, they varied between muscles. Also, the average whole muscle Tc of FDB was significantly (p < 0.05) shorter (faster) (Tc = 58 ms) than in all other foot muscles investigated (ADM Tc = 72 ms, EDB Tc = 72 ms and ABH Tc = 69 ms). The results suggest that the architecture and contraction time of the FDB reflect its unique direct contribution, through toe flexion, to postural stability and the rapid development of ground reaction forces during forceful activities such as running and jumping.  相似文献   

11.
The purpose of the study was to investigate whether boys and men utilise different control strategies whilst hopping. Eleven boys (11–12 yr old) and ten men completed hopping at 1.5 Hz, 3.0 Hz and at their preferred frequency. A footswitch measured contact and flight times, from which leg stiffness was calculated. Simultaneously, surface electromyograms (EMGs) of selected lower limb muscles were recorded and quantified for each 30 ms period during the first 120 ms post-ground contact. At 1.5 Hz there were no differences between the groups in relative stiffness or muscle activity. At 3.0 Hz men had significantly shorter contact times (P = 0.013), longer flight times (P = 0.002), greater relative stiffness (P = 0.01) and significantly greater soleus (P = 0.012) and vastus lateralis (P < 0.001) activity during the initial 30 ms post-ground contact. At the preferred frequency men hopped significantly faster than the boys (P = 0.007), with greater leg stiffness (P < 0.01) and with more extensor activity in most time periods. Boys and men demonstrated similar control strategies when hopping at a slow frequency, but when hopping frequency increased men were able to better increase feedforward and reflex muscle activity to hop with greater relative stiffness.  相似文献   

12.
BackgroundZn-deficiency has been associated with numerous alterations during pregnancy including low birth weight; however, the research relating neonatal zinc status and birth weight has not produced reliable results.ObjectiveTo compare the serum Zn-levels of cord blood in healthy newborns and low birth weight newborns, and to assess a possible relationship between zinc concentration and neonatal birth weight and gestational age.Material and methods123 newborns divided in “study group” (n = 50) with <2500 g birth weight neonates and “control group” (n = 73) with ≥2500 g birth weight neonates were enrolled. Study group was subdivided according to gestational age in preterm (<37 weeks) and full-term (≥37 weeks). Serum cord blood samples were collected and the Zn-levels were analyzed using flame Atomic Absorption Spectrophotometry method and the result was expressed in μmol/L. The Zn-levels were compared between the groups (Mann–Whitney-U test) and the Zn-levels were correlated with the birth weight and gestational age (Spearman's rank correlations).ResultsStatistically significant low positive correlation between Zn-levels and birth weight (ρ = 0.283; p = 0.005) was found. No statistically significant difference between Zn-levels of study and control groups [17.00 ± 0.43 vs. 18.16 ± 0.32 (p = 0.053)] was found. Statistically significant low positive correlation between Zn-levels and gestational age (ρ = 0.351; p = 0.001) was found. No statistically significant difference between Zn-levels of preterm as compare to full-term newborns [16.33 ± 0.42 vs. 18.43 ± 0.93 (p = 0.079)] was found. Zn-level of preterm subgroup was significantly lower compared to control group (p = 0.001).ConclusionsDespite low birth weight preterm neonates had significantly lower serum zinc levels of cord blood than healthy term neonates, the correlation between cord blood zinc levels and birth weight and gestational age was lower. The results are not enough to relate the change in cord blood zinc concentration to the birth weight values or gestational period. In relation to complicated pregnancies, further studies regarding zinc levels in blood in our population are required.  相似文献   

13.
ObjectiveTo analyze the effect of gender on median nerve (MN) and ulnar nerve (UN) sensorial responses over ring finger (RF).Materials and methodsResults of individuals admitted to our ENMG laboratory between June 2011 and March 2012 for nerve conduction studies (NCSs) were retrospectively analyzed. Sensory NCSs were performed by standard antidromic technique.ResultsTotally, 112 normal recordings belong to 100 patients were included. Mean antidromic sensory conduction velocity of MNs (wrist-to-second finger) or UNs (wrist-to-fifth finger) was not different between two genders. Mean sensory nerve action potential (SNAP) amplitude of MN from second finger was also not different between two genders. However, mean SNAP amplitude of UN from fifth finger was higher in females. In RF’s sensorial response studies; mean peak latency of MN was similar between females and males (3.05 ± 0.25 ms vs. 3.14 ± 0.29 ms, p = 0.111), whereas one of UN was shorter in females (2.86 ± 0.22 ms vs. 3.04 ± 0.31 ms, p = 0.001). MN to UN latency difference to RF was greater in females than males (0.19 ± 0.15 ms vs. 0.10 ± 0.16 ms, p = 0.007). Mean SNAP amplitude of MN and UN were both higher in females than males (17.9 ± 7.1 μV vs. 14.1 ± 5.5 μV, p = 0.011 and 18.5 ± 8.0 μV vs. 12.9 ± 6.1 μV, p = 0.0009, respectively). All data of NCSs were re-analyzed after adjustment for age, and obtained findings regarding effect of aging are also included.ConclusionGender has a prominent effect on RF’s sensorial responses. Normative values regarding them should be prepared with adjustment for gender.  相似文献   

14.
AimThe aim of the study was to evaluate computed tomography (CT) artifacts and image recognition of the CyberKnife system. Regarding fiducial markers, VISICOIL of 0.5 mm × 5.0 mm and 0.75 mm × 5.0 mm, ball-shaped Gold Anchor (GA) of 0.28 mm × 10 mm and 0.28 mm × 20 mm, were compared with the standard cylinder marker of 0.9 mm × 3.0 mm (ACCULOC).BackgroundRecently, various kinds of commercial fiducial markers have been available in CyberKnife treatment.Materials and methodsThe CT images of a water equivalent gel with each fiducial marker were acquired for the evaluation of CT artifacts. The evaluation was performed using the standard deviation of Hounsfield Unit (HU) value for a rectangle region near the fiducial marker. Then, to evaluate the image recognition, each fiducial marker was located to overlap in the target locating system (TLS) for the two sites; the vertebral bone and the pubic bone.ResultsFor CT artifacts, the standard deviations of the VISICOIL of 0.5 mm × 5.0 mm was the smallest. The image recognition of four fiducial markers had a value close to the standard cylinder marker and was feasible for common use, but was slightly poorer when using GA of 0.28 mm × 10 mm in the dynamic conditions.ConclusionOur results indicated that VISICOIL 0.5 × 5.0 mm and the GAs can be used nearly always for CyberKnife treatment in spite of their much thinner needles than those of cylinder types.  相似文献   

15.
PurposeWithin the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis.MethodsTest objects were imaged at 38 keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated.ResultsFor a voxel size of (60 μm)3, images without phase retrieval showed higher spatial resolution (6.7 mm−1 at 10% MTF) than corresponding images with phase retrieval (2.5 mm−1). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130 μm could be detected in both types of images.ConclusionsThe investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise.  相似文献   

16.
Activation mapping is required to effectively ablate atrial tachycardia (AT). Conventional tools to assess local activation time (LAT) are based upon the peak of the bipolar electrogram (B-EGM, LATPeak) and the maximal negative slope of the unipolar electrogram (U-EGM, LATSlope). Bipolar electrograms are influenced by wavefront direction, bipole orientation, and inter-electrode spacing causing ambiguity in peak detection, whereas unipolar electrograms are disturbed by the presence of far-field signals. We developed a new algorithm to detect the beginning and end of bipolar electrograms (tbegin and tend). Then, we introduced new LAT methods related to the onset of B-EGMs (LATOnset), the center of mass of B-EGMs (LATCoM), and the slope of U-EGMs within a pre-defined window (LATSlope-hybrid).In total 3752 recordings from 31 AT patients were retrospectively analyzed. The signal-to-noise ratio (SNR) for B-EGMs was calculated to differentiate algorithmically high from low quality electrograms (HQ and LQ). In a subset of 328 B-EGMs, five experts validated the tbegin as determined by the algorithm by visual rating. The newly developed LAT methods were compared to the conventional LAT methods and to one another (Bland–Altman plots) in both HQ (n = 3003) and LQ EGMs (n = 749).The tbegin algorithm was accurate (deviation < ±10 ms) in 96 ± 4% of HQ and 91 ± 8% of LQ B-EGMs. BA plots revealed the following difference (bias) and variation in HQ and LQ EGMs respectively: (1) LATOnset vs. LATPeak: 27 ± 30 ms and 24 ± 62 ms; (2) LATCoM vs. LATPeak: 0 ± 16 ms and 2 ± 38 ms; (3) LATSlope-hybrid vs. LATSlope: 1 ± 32 ms and 15 ± 110 ms; (4) LATOnset vs. LATCoM: 22 ± 24 ms and 18 ± 22 ms; (5) LATOnset vs. LATSlope-hybrid: 16 ± 18 ms and 13 ± 22 ms; and (6) LATCoM vs. LATSlope-hybrid: 5 ± 20 ms and 4 ± 18 ms.In the present study, we introduced three new methods to assess local activation time in AT, based upon an algorithm detecting accurately the beginning and end of the B-EGM complex. BA analysis of the new methods showed similar variation in high and low quality EGMs, suggesting that they introduce less ambiguity than the conventional peak method. LATOnset consistently yielded an earlier activation moment. LATSlope-hybrid – by blanking far-field potentials – seems to be the optimal method for detection of the maximal negative slope in U-EGMs. Interestingly, LATCoM in B-EGMs coincided with the maximal negative slope in U-EGMs, suggesting its physiological sense and future use. The new LAT methods can be implemented in real-time mapping applications.  相似文献   

17.
Low back pain (LBP) is one of the most common symptoms reported in adults. However, the contribution of postural control on the lumbar spine and hips during squatting has not been carefully investigated in individuals with LBP. The aim of this study was to compare three-dimensional kinematic changes of the lumbar spine and hips between subjects with and without idiopathic chronic LBP during squatting activities. In total, 30 subjects enrolled in the study (15 control subjects and 15 subjects with idiopathic chronic LBP). All participants were asked to perform squatting activities five times repeatedly while holding a load of 2 kg in a basket. The outcome measures included the Oswestry Disability Index (ODI) and kinematic angular displacement for the hips and lumbar spine. The LBP group demonstrated increased range of motion (ROM) in flexion of the dominant (T = ?2.14, p = 0.03) and non-dominant (T = ?2.11, p = 0.03) hips during squatting. The lumbar spine flexion ROM significantly decreased (T = 2.20, p = 0.03). The kinematic changes demonstrated interactions with region × group (F = 5.56, p = 0.02), plane × group (F = 4.36, p = 0.04), and region × plane (F = 2292.47, p = 0.001). The ODI level demonstrated significant interaction on combined effects of body region and plane (F = 4.91, p = 0.03). Therefore, the LBP group utilized a compensation strategy to increase hip flexion with a stiffened lumbar spine in the sagittal plane during squatting. This compensatory kinematic strategy could apply to clinical management used to enhance lumbar spine flexibility in subjects with idiopathic chronic LBP.  相似文献   

18.
《Journal of Asia》2014,17(4):737-743
An autonomous robot (Cabbot) was built to control insect pests in a plastic greenhouse and utilized to sample adult whiteflies (Bemisia tabaci) on paprika plants (Capsicum annum var. angulosum). To accomplish this, a sampling device consisting of an air compressor for pest agitation, a sticky trap (100 mm × 150 mm) and an image processing system for pest identification were installed on the Cabbot. The sampling precision of the Cabbot (D = 0.16) was higher than that of the sticky trap (D = 0.19) when sampling of adult white flies was conducted in caged pots. The Cabbot could also collect a substantial number of individuals within a short duration (3 minutes). The collection efficiency (i.e., percent of samples collected at least n (1 in this case) individuals to the total sample number) of insects by the Cabbot was markedly high at low population size, showing approximately 30% when the population size was ≤ 16 individuals per plant. The sampling precision and collection efficiency suggested that the Cabbot is effective in local, short-term sampling and could be used for early warning of pest occurrences.  相似文献   

19.
Protocorm cultures of Dendrobium candidum were established in balloon type bubble bioreactors using Murashige and Skoog (MS) medium with 0.5 mg l−1 α-naphthaleneacetic acid (NAA), 2.5% (w/v) sucrose, 5:25 mM NH4:NO3 and 1% (v/v) banana homogenate for the production of biomass and bioactive compounds. In 3 l bioreactor containing 2 l medium, a maximum protocorm biomass (21.0 g l−1 dry biomass) and also optimum quantities of total polysaccharides (389.3 mg g−1 DW), coumarins (18.0 mg g−1 DW), polyphenolics (11.9 mg g−1 DW), and flavonoids (4.5 mg g−1 DW) were achieved after 7 weeks of culture. Based on these studies, 5 and 10 l bioreactor cultures were established to harvest 80 g and 160 g dry biomass. In 10 l bioreactors, the protocorms grown were accumulated with optimal levels of polysaccharides (424.1 mg g−1 DW), coumarins (15.8 mg g−1 DW), polyphenols (9.03 mg g−1 DW) and flavonoids (4.7 mg g−1 DW). The bioreactor technology developed here will be useful for the production of important bioactive compounds from D. candidum.  相似文献   

20.
Background: Transforming growth factor-β1 (TGF-β1) plays a critical role in human cancer development. Present study aimed to explore the clinical significance of serum TGF-β1 levels in patients with lung cancer and analyze the relationship between TGF-β1 and existing tumor markers for lung cancer. Methods: Serum was collected from 118 patients with lung cancer and 40 healthy volunteers. Serum TGF-β1 levels were measured by enzyme-linked immunosorbent assay (ELISA), and the association with various clinical characteristics was analyzed. The diagnostic value of TGF-β1 was assessed alone and in combination with existing tumor markers for lung cancer. Results: Serum TGF-β1 levels were significantly higher in patients with lung cancer compared to healthy volunteers [0.6 × 105 (0.4 × 105, 0.9 × 105) pg/ml vs 0.5 × 105 (0.3 × 105, 0.7 × 105) pg/ml, P = 0.040]. Although there was a positive correlation between serum TGF-β1 levels and advanced stages, the significant difference was not found between early stages and advanced stages (P = 0.116). The ability of serum TGF-β1 to discriminate lung cancer at a cutoff value of 79,168 pg/ml exhibited sensitivity of 30.6% and specificity of 97.5%. Serum TGF-β1 levels were correlated to cytokeratin fragment 21-1 (CYFRA21-1; R = 0.308, P = 0.020) and neuron-specific enolase (NSE; R = 0.558, P = 0.003). The diagnostic accuracy rates for the existing lung-tumor markers, as SCC, CYFRA21-1, and NSE, were increased from 20.0%, 34.6%, and 45.9% to 48.9%, 51.7%, and 54.5%, respectively by the inclusion of serum TGF-β1 levels. Conclusion: Quantification of serum TGF-β1 levels by ELISA may provide a novel complementary tool for the clinical diagnosis of lung cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号