1.
Traditionally, many cell-based assays that analyze cell populations and functionalities have been performed using flow cytometry. However, flow cytometers remain relatively expensive and require highly trained operators for routine maintenance and data analysis. Recently, an image cytometry system has been developed by Nexcelom Bioscience (Lawrence, MA, USA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Image cytometry is analogous to flow cytometry in that gating operations can be performed on the cell population based on size and fluorescent intensity. In addition, the image cytometer is capable of capturing bright-field and fluorescent images, allowing for the measurement of cellular size and fluorescence intensity data. In this study, we labeled a population of cells with an enzymatic vitality stain (calcein-AM) and a cell viability dye (propidium iodide) and compared the data generated by flow and image cytometry. We report that measuring vitality and viability using the image cytometer is as effective as flow cytometric assays and allows for visual confirmation of the sample to exclude cellular debris. Image cytometry offers a direct method for performing fluorescent cell-based assays but also may be used as a complementary tool to flow cytometers for aiding the analysis of more complex samples.  相似文献   

2.
BACKGROUND: The tools for high throughput flow cytometry have been limited in part because of the requirement that the samples must flow under pressure. We describe a simple system for sampling repetitively from an open vessel. METHODS: Under computer control, the sample is loaded into a sample loop in a reciprocating eight-way valve by the action of a syringe. When the valve position is switched, the plug of sample in the sample loop is transported to the flow cytometer by a pressure-driven fluid line. By coupling the plug-forming capability to a second multi-port valve, samples can be delivered sequentially from separate vessels. RESULTS: The valve is able to deliver samples at rates ranging up to about 9 samples per minute. Each plug of sample has uniform delivery characteristics with a reproducible coefficient of variation (CV). Even at the highest sampling rate, carryover between samples is limited. CONCLUSIONS: Plug-flow flow cytometry has the potential to automate the delivery of small samples from unpressurized sources at rates compatible with many screening and assay applications.  相似文献   

3.
BACKGROUND: The development of inexpensive small flow cytometers is recognized as an important goal for many applications ranging from medical uses in developing countries for disease diagnosis to use as an analytical platform in support of homeland defense. Although hydrodynamic focusing is highly effective at particle positioning, the use of sheath fluid increases assay cost and reduces instrument utility for field and autonomous remote operations. METHODS: This work presents the creation of a novel flow cell that uses ultrasonic acoustic energy to focus small particles to the center of a flowing stream for analysis by flow cytometry. Experiments using this flow cell are described wherein its efficacy is evaluated under flow cytometric conditions with fluorescent microspheres. RESULTS: Preliminary laboratory experiments demonstrate acoustic focusing of flowing 10-microm latex particles into a tight sample stream that is approximately 40 microm in diameter. Prototype flow cytometer measurements using an acoustic-focusing flow chamber demonstrated focusing of a microsphere sample to a central stream approximately 40 microm in diameter, yielding a definite fluorescence peak for the microspheres as compared with a broad distribution for unfocused microspheres. CONCLUSIONS: The flow cell developed here uses acoustic focusing, which inherently concentrates the sample particles to the center of the sample stream. This method could eliminate the need for sheath fluid, and will enable increased interrogation times for enhanced sensitivity, while maintaining high particle-analysis rates. The concentration effect will also enable the analysis of extremely dilute samples on the order of several particles per liter, at analysis rates of a few particles per second. Such features offer the possibility of a truly versatile low-cost portable flow cytometer for field applications.  相似文献   

4.
We propose a method which significantly shortens the time required for both the collection and analysis of data derived from multiple sample, flow cytometric kinetic assays. We have defined the term Time Interval Gating (TIG) to describe this method. TIG effectively allows one flow cytometer to concurrently monitor several samples over the course of a kinetic assay. Data for all samples are stored in a single FCS 2.0 compatible listmode data file which we refer to as the TIG data file. TIG is adaptable to most commerical flow cytometers. Standard listmode analysis software can be used to analyze the TIG data files and correlate any combination of tubes and/or time intervals from the assay. Results for the entire assay can be displayed on a single two parameter plot. This paper describes how TIG is applied to neutrophil oxidative burst measurement using a standard EPICS Elite flow cytometer. In this assay, 11 samples were each monitored for 30 min to identify the extent to which volatile organic chemicals (VOCs) inhibited the oxidation of DCFH in stimulated neutrophils. TIG makes the oxidative burst assay practical for high volume screening by reducing the overall flow cytometer and analysis time required by a factor of ten. In addition, TIG provides an organized approach to managing data acquisition on instruments equipped with automated sampling systems.  相似文献   

5.
Two specially shaped sample injection tubes orient flat-shaped mature sperm heads in a flow cytometer. Orientation allows control of a photometric difficulty experienced with some flow cytometers in the measurement of fluorescent and scattered light from sperm and other flat cells. Both relative DNA-stain content and a measure of cell flatness can now be determined simultaneously for each cell at the high rates possible with flow instruments.  相似文献   

6.
Multistation multiparameter flow cytometry: a critical review and rationale   总被引:6,自引:0,他引:6  
H M Shapiro 《Cytometry》1983,3(4):227-243
The capacity for fluorescence excitation by beams of different wavelengths at separate points along the sample stream, and the capacity for computer analysis of multiparameter data thus obtained, are now available in flow cytometer/sorter systems from commercial producers. It is now readily apparent to most experienced users of flow cytometers that such multiparameter analysis offers the most convenient solution to the problem of characterizing subpopulations of cells within a mixed population. The use of multiple beams facilitates resolution of fluorescence signals from several probes within or upon a single cell and widens the range of analytical alternatives available to experimenters. This critical review discusses the history of the instrumentation, the parameters now measurable and the probes used for their measurement, and the methods for data analysis. Required sensitivity and precision are discussed, leading to the conclusion that many of the advantages of multistation, multiparameter flow cytometry can be made available in less complex and less costly instruments using less powerful sources and less elaborate computer hardware than are presently incorporated in commercial apparatus.  相似文献   

7.
HyperCyt, an automated sample handling system for flow cytometry that uses air bubbles to separate samples sequentially introduced from multiwell plates by an autosampler. In a previously documented HyperCyt configuration, air bubble separated compounds in one sample line and a continuous stream of cells in another are mixed in-line for serial flow cytometric cell response analysis. To expand capabilities for high-throughput bioactive compound screening, the authors investigated using this system configuration in combination with automated cell sorting. Peptide ligands were sampled from a 96-well plate, mixed in-line with fluo-4-loaded, formyl peptide receptor-transfected U937 cells, and screened at a rate of 3 peptide reactions per minute with approximately 10,000 cells analyzed per reaction. Cell Ca(2+) responses were detected to as little as 10(-11) M peptide with no detectable carryover between samples at up to 10(-7) M peptide. After expansion in culture, cells sort-purified from the 10% highest responders exhibited enhanced sensitivity and more sustained responses to peptide. Thus, a highly responsive cell subset was isolated under high-throughput mixing and sorting conditions in which response detection capability spanned a 1000-fold range of peptide concentration. With single-cell readout systems for protein expression libraries, this technology offers the promise of screening millions of discrete compound interactions per day.  相似文献   

8.
Flow cytometers based on optical sensing utilize external light sources and fluorescent dyes to measure one or more specific components or properties of individual cells or subcellular particles in liquid suspension. To provide for independent excitation of two dyes used in double staining experiments we have constructed a high resolution flow cytometer that uses two laser beams to provide two wavelengths of excitation. These beams are separated spatially so that cells flow through them sequentially, with a time separation of about 20 musec. Since the dyes are excited sequentially their emission occurs at different times and their emission spectra may overlap without causing any difficulty in analysis. We have developed new light collection optics that permit up to four measurements to be made on each cell. This approach greatly increases the number of dye combinations that can be used in flow cytometry, thus removing a significant limitation of single illumination instruments.  相似文献   

9.
Advances in electro-optic technology within the past 2 years, notably the development of high-intensity light-emitting diodes and highly efficient charge-coupled device cameras, have made it feasible to produce small, simple, rugged, automated fluorescence image cytometers, with selling prices well below 10,000 US dollars, that can make measurements previously the exclusive domain of flow and scanning cytometers costing many times more. It should be feasible to apply the new cytometric technology in scientific and geographic areas for which a previous generation of instruments was too complex and too expensive, e.g., to problems of diagnosis and management of infectious diseases prevalent at critical levels in resource-poor areas, such as the human immunodeficiency virus, malaria, and tuberculosis.  相似文献   

10.
F L Battye  W Darling  J Beall 《Cytometry》1985,6(5):492-494
A simple device has been developed for delivering samples into a flow cytometer. Designed with economy, simplicity, and flexibility in mind, this device, having only one moving part, can be used for sample volumes as small as 20 microliter, for virtually any form of cell sample container, and for a wide range of cell concentrations. It consists essentially of a lever-operated disc valve that allows the cell sample to be loaded into a loop of tubing and then to be injected into the cytometer nozzle under pressure from a saline source. The sampler has lifted the maximum analytical throughput of a FACS II cell sorter to better than 120 samples per hour.  相似文献   

11.
Flow cytometry specializes in high-content measurements of cells and particles in suspension. Having long excelled in analytical throughput of single cells and particles, only recently with the advent of HyperCyt sampling technology, flow cytometry's multiexperiment throughput has begun to approach the point of practicality for efficiently analyzing hundreds-of-thousands of samples, the realm of high-throughput screening (HTS). To extend performance and automation compatibility, we built a HyperCyt-linked Cluster Cytometer platform, a network of flow cytometers for analyzing samples displayed in high-density, 1,536-well plate format. To assess the performance, we used cell- and microsphere-based HTS assays that had been well characterized in the previous studies. Experiments addressed important technical issues: challenges of small wells (assay volumes 10 μL or less, reagent mixing, cell and particle suspension), detecting and correcting for differences in performance of individual flow cytometers, and the ability to reanalyze a plate in the event of problems encountered during the primary analysis. Boosting sample throughput an additional fourfold, this platform is uniquely positioned to synergize with expanding suspension array and cell barcoding technologies in which as many as 100 experiments are performed in a single well or sample. As high-performance flow cytometers shrink in cost and size, cluster cytometry promises to become a practical, productive approach for HTS, and other large-scale investigations of biological complexity.  相似文献   

12.
Flow cytometry: instrumentation and application in phytoplankton research   总被引:1,自引:0,他引:1  
In flow cytometry, light scattering and fluorescence of individual particles in suspension is measured at high speed. When applied to planktonic particles, the light scattering and (auto-)fluorescence properties of algal cells can be used for cell identification and counting. Analysis of the wide size spectrum of phytoplankton species, generally present in eutrophic inland and coastal waters, requires flow cytometers specially designed for this purpose. This paper compares the performance in phytoplankton research of a commercial flow cytometer to a purpose built instrument. It reports on the identification of phytoplankton and indicates an area where flow cytometry may supersede more conventional techniques: the analysis of morphological and physiological characteristics of subpopulations in phytoplankton samples.  相似文献   

13.
BACKGROUND: Nanophytoplankton (2-20 microm) are less numerous than picophytoplankton (<2 microm) in the oceans but their biomass and production are comparable and sometimes higher. The accuracy of cytometry-based enumeration of phytoplankton ultimately depends on cell abundance and sample flow rate. Commercial flow cytometers in which sheath and core streams are driven by air pressure cannot produce sufficiently high, stable sample flow rate. The present study demonstrates the applicability of a syringe pump for flow cytometric enumeration of oceanic nanophytoplankton on two meridional transects across the Atlantic Ocean. METHODS: Commercially available syringe pumps were used to deliver live phytoplankton samples into a flow cell of standard flow cytometers (FACSort, FACSCalibur, BD) with increased flow rate of > 1.0 ml min(-) (1) compared to the normal air pressure sample delivery of < 0.1 ml min(-) (1). An auxiliary application of syringe pump flow cytometry for calibrating 0.5 microm bead concentration standards is also discussed. RESULTS: The results demonstrated that flow cytometry of samples injected at rates above 0.1 ml min(-) (1) is achievable and worthwhile. Counts of phytoplankton in air and syringe pumped samples agreed closely. Syringe pumping of samples offered a broader range of flow rates up to 0.8-1.0 ml min(-) (1) without detrimental effect on flow cytometric enumeration of cells. The increased number of coincidences at high flow rates led to an approximate 10% decrease of Cyanobacteria counts when the acquisition rate approached 1,000 particles s(-) (1), but seemed to have a lesser effect on counting rarer phytoplankton. The syringe pump flow cytometry allowed enumeration of phytoplankton groups at concentrations of 5-100 cells ml(-) (1), cell concentrations equivalent to those of Cyanobacteria in the twilight deep ocean. CONCLUSION: The proposed syringe pump modification of a FACS instrument represents a significant improvement for accurate enumeration of the less abundant phytoplankton and so gives better estimations of phytoplankton distribution and standing stocks.  相似文献   

14.
BACKGROUND: Although some manufacturers have optimistically described instruments with prices in the 40,000 US dollars range as "personal cytometers", analogy with the personal computer suggests that the target price for a true "personal" cytometer should be under 5,000 US dollars. Since such an apparatus could find a wide range of applications in cytomics in both developing and developed countries, it seemed desirable to consider its technical and economic feasibility. METHODS: Using resolution targets and a variety of fluorescent bead standards immobilized on filters and/or slides, we evaluated high-intensity LEDs as fluorescence excitation sources, relatively inexpensive CCD cameras as detectors, and 35 mm camera lenses and plastic low-power microscope optics for light collection in a simple, inexpensive low-resolution imaging cytometer. RESULTS: The components tested could be combined toproduce an instrument capable of detecting fewer than 10,000 molecules of cell-associated fluorescent label, and thus applicable to a broad range of cytometric tasks. CONCLUSIONS: Given the requirements for light sources, detectors, optics, mechanics, electronics and data analysis hardware and software, and the components presently available, it should be easier to reach the desired 5,000 US dollars price point with an image cytometer than with a flow cytometer.  相似文献   

15.
INTRODUCTION: Violet laser diodes have become common and reliable laser sources for benchtop flow cytometers. While these lasers are very useful for a variety of violet and some ultraviolet-excited fluorochromes (e.g., DAPI), they do not efficiently excite most UV-stimulated probes. In this study, the next generation of InGaN near-UV laser diodes (NUVLDs) emitting in the 370-375-nm range have been evaluated as laser sources for cuvette-based flow cytometers. METHODS: Several NUVLDs, ranging in wavelength from 370 to 374 nm and in power level from 1.5 to 10 mW, were mounted on a BD Biosciences LSR II and evaluated for their ability to excite cells labeled with the UV DNA binding dye DAPI, several UV phenotyping fluorochromes (including Alexa Fluor 350, Marina Blue, and quantum dots), and the fluorescent calcium chelator indo-1. RESULTS: NUVLDs at the 8-10-mW power range gave detection sensitivity levels comparable to more powerful solid-state and ion laser sources, using low-fluorescence microsphere beads as measurement standards. NUVLDs at all tested power levels allowed extremely high-resolution DAPI cell cycle analysis, and sources in the 8-10-mW power range excited Alexa Fluor 350, Marina Blue, and a variety of quantum dots at virtually the same signal-to-noise ratios as more powerful UV sources. CONCLUSIONS: These evaluations indicate that near-UV laser diodes installed on a cuvette-based flow cytometer performed nearly as well as more powerful solid-state UV lasers on the same instrumentation, and comparably to more powerful ion lasers on a jet-in-air system, and. Despite their limited power, integration of these small and inexpensive lasers into benchtop flow cytometers should allow the use of flow cytometric applications requiring UV excitation on a wide variety of instruments.  相似文献   

16.
R C Mann 《Cytometry》1987,8(2):184-189
Increasing numbers of parameters that are accessible to simultaneous measurement in flow cytometric instruments, combined with the extremely large sample sizes common in flow cytometry, make it necessary to examine methods of multivariate statistics for their applicability to problems of visualization and quantitative analysis of flow cytometric data. This article describes some approaches to dimensionality reduction that appear well suited for data sets obtained by flow cytometry.  相似文献   

17.
Flow cytometry and cell sorting   总被引:1,自引:0,他引:1  
M J Fulwyler 《Blood cells》1980,6(2):173-184
Flow cytometry has become an important research tool in cytology, genetics, immunology, and microbiology. The information gained from cytometric instruments is quantitative and of high statistical precision, enabling resolution of cell subpopulations. Although increasing, application to cytology is hindered by inadequate appreciation of the nature of flow cytometry and the information obtained. Many cytologic questions can be reexamined from the perspective of this technology to obtain knowledge not accessible with conventional techniques. A flow cytometer and cell sorter are described. The physical, biochemical, and functional properties measurable by these systems are discussed.  相似文献   

18.
《Autophagy》2013,9(9):1371-1382
Autophagy is an important cellular catabolic process that plays a variety of important roles, including maintenance of the amino acid pool during starvation, recycling of damaged proteins and organelles, and clearance of intracellular microbes. Currently employed autophagy detection methods include fluorescence microscopy, biochemical measurement, SDS-PAGE and western blotting, but they are time consuming, labor intensive, and require much experience for accurate interpretation. More recently, development of novel fluorescent probes have allowed the investigation of autophagy via standard flow cytometry. However, flow cytometers remain relatively expensive and require a considerable amount of maintenance. Previously, image-based cytometry has been shown to perform automated fluorescence-based cellular analysis comparable to flow cytometry. In this study, we developed a novel method using the Cellometer image-based cytometer in combination with Cyto-ID® Green dye for autophagy detection in live cells. The method is compared with flow cytometry by measuring macroautophagy in nutrient-starved Jurkat cells. Results demonstrate similar trends of autophagic response, but different magnitude of fluorescence signal increases, which may arise from different analysis approaches characteristic of the two instrument platforms. The possibility of using this method for drug discovery applications is also demonstrated through the measurement of dose-response kinetics upon induction of autophagy with rapamycin and tamoxifen. The described image-based cytometry/fluorescent dye method should serve as a useful addition to the current arsenal of techniques available in support of autophagy-based drug discovery relating to various pathological disorders.  相似文献   

19.
LL Chan  D Shen  AR Wilkinson  W Patton  N Lai  E Chan  D Kuksin  B Lin  J Qiu 《Autophagy》2012,8(9):1371-1382
Autophagy is an important cellular catabolic process that plays a variety of important roles, including maintenance of the amino acid pool during starvation, recycling of damaged proteins and organelles, and clearance of intracellular microbes. Currently employed autophagy detection methods include fluorescence microscopy, biochemical measurement, SDS-PAGE and western blotting, but they are time consuming, labor intensive, and require much experience for accurate interpretation. More recently, development of novel fluorescent probes have allowed the investigation of autophagy via standard flow cytometry. However, flow cytometers remain relatively expensive and require a considerable amount of maintenance. Previously, image-based cytometry has been shown to perform automated fluorescence-based cellular analysis comparable to flow cytometry. In this study, we developed a novel method using the Cellometer image-based cytometer in combination with Cyto-ID® Green dye for autophagy detection in live cells. The method is compared with flow cytometry by measuring macroautophagy in nutrient-starved Jurkat cells. Results demonstrate similar trends of autophagic response, but different magnitude of fluorescence signal increases, which may arise from different analysis approaches characteristic of the two instrument platforms. The possibility of using this method for drug discovery applications is also demonstrated through the measurement of dose-response kinetics upon induction of autophagy with rapamycin and tamoxifen. The described image-based cytometry/fluorescent dye method should serve as a useful addition to the current arsenal of techniques available in support of autophagy-based drug discovery relating to various pathological disorders.  相似文献   

20.
Fluorescence is a mainstay of bioanalytical methods, offering sensitive and quantitative reporting, often in multiplexed or multiparameter assays. Perhaps the best example of the latter is flow cytometry, where instruments equipped with multiple lasers and detectors allow measurement of 15 or more different fluorophores simultaneously, but increases beyond this number are limited by the relatively broad emission spectra. Surface enhanced Raman scattering (SERS) from metal nanoparticles can produce signal intensities that rival fluorescence, but with narrower spectral features that allow a greater degree of multiplexing. We are developing nanoparticle SERS tags as well as Raman flow cytometers for multiparameter single cell analysis of suspension or adherent cells. SERS tags are based on plasmonically active nanoparticles (gold nanorods) whose plasmon resonance can be tuned to give optimal SERS signals at a desired excitation wavelength. Raman resonant compounds are adsorbed on the nanoparticles to confer a unique spectral fingerprint on each SERS tag, which are then encapsulated in a polymer coating for conjugation to antibodies or other targeting molecules. Raman flow cytometry employs a high resolution spectral flow cytometer capable of measuring the complete SERS spectra, as well as conventional flow cytometry measurements, from thousands of individual cells per minute. Automated spectral unmixing algorithms extract the contributions of each SERS tag from each cell to generate high content, multiparameter single cell population data. SERS-based cytometry is a powerful complement to conventional fluorescence-based cytometry. The narrow spectral features of the SERS signal enables more distinct probes to be measured in a smaller region of the optical spectrum with a single laser and detector, allowing for higher levels of multiplexing and multiparameter analysis.  相似文献   