首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeThis study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer.MethodsWe used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D95%, and D2% to planning target volume (PTV), mean dose, V50Gy, V70Gy, V75Gy, and V78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity.ResultsRP and CMO values for PTV D95%, PTV D2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V50Gy, and V70Gy to rectum were superior or comparable to CMO values; RP V75Gy and V78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 ± 55 MU and CMO: 580 ± 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 ± 0.02 and CMO: 0.35 ± 0.03 (p < 0.05).ConclusionsRP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner’s skill and knowledge.  相似文献   

2.
3.
AimThe primary aim of this study is to provide preliminary indications for safe constraints of rectum and bladder in patients re-irradiated with stereotactic body RT (SBRT).MethodsData from patients treated for prostate cancer (PCa) and intraprostatic relapse, from 1998 to 2016, were retrospectively collected. First RT course was delivered with 3D conformal RT techniques, SBRT or volumetric modulated arc therapy (VMAT). All patients underwent re-irradiation with SBRT with heavy hypofractionated schedules. Cumulative dose-volume values to organs at risk (OARs) were computed and possible correlation with developed toxicities was investigated.ResultsTwenty-six patients were included. Median age at re-irradiation was 75 years, mean interval between the two RT courses was 5.6 years and the median follow-up was 47.7 months (13.4–114.3 months). After re-irradiation, acute and late G ≥ 2 GU toxicity events were reported in 3 (12%) and 10 (38%) patients, respectively, while late G ≥ 2 GI events were reported in 4 (15%) patients. No acute G ≥ 2 GI side effects were registered. Patients receiving an equivalent uniform dose of the two RT treatments < 131 Gy appeared to be at higher risk of progression (4-yr b-PFS: 19% vs 33%, p = 0.145). Cumulative re-irradiation constraints that appear to be safe are D30% < 57.9 Gy for bladder and D30% < 66.0 Gy, D60% < 38.0 Gy and V122.1 Gy < 5% for rectum.ConclusionPreliminary re-irradiation constraints for bladder and rectum have been reported. Our preliminary investigation may serve to clear some grey areas of PCa re-irradiation.  相似文献   

4.
PurposeTo evaluate the planning feasibility of dose-escalated total marrow irradiation (TMI) with simultaneous integrated boost (SIB) to the active bone marrow (ABM) using volumetric modulated arc therapy (VMAT), and to assess the impact of using planning organs at risk (OAR) volumes (PRV) accounting for breathing motion in the optimization.MethodsFive patients underwent whole-body CT and thoraco-abdominal 4DCT. A planning target volume (PTV) including all bones and ABM was contoured on each whole-body CT. PRV of selected OAR (liver, heart, kidneys, lungs, spleen, stomach) were determined with 4DCT. Planning consisted of 9–10 full 6 MV photon VMAT arcs. Four plans were created for each patient with 12 Gy prescribed to the PTV, with or without an additional 4 Gy SIB to the ABM. Planning dose constraints were set on the OAR or on the PRV. Planning objective was a PTV Dmean < 110% of the prescribed dose, a PTV V110% < 50%, and OAR Dmean ≤ 50–60%.ResultsPTV Dmean < 110% was accomplished for most plans (n = 18/20), while all achieved V110%<50%. SIB plans succeeded to optimally cover the boost volume (median ABM Dmean = 16.3 Gy) and resulted in similar OAR sparing compared to plans without SIB (median OAR Dmean = 40–54% of the ABM prescribed dose). No statistically significant differences between plans optimized with constraints on OAR or PRV were found.ConclusionsAdding a 4 Gy SIB to the ABM for TMI is feasible with VMAT technique, and results in OAR sparing similar to plans without SIB. Setting dose constraints on PRV does not impair PTV dosimetric parameters.  相似文献   

5.
PurposeRadiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks.MethodsFor each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency.ResultsPlan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average Dmean −7%) and bowel sparing (Dmean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose (Dmean +42%) in stage 1 and lower rectum dose (Dmean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively.ConclusionMCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal.  相似文献   

6.
PurposeTo demonstrate the strength of an innovative knowledge-based model-building method for radiotherapy planning using hypofractionated, multi-target prostate patients.Material and methodsAn initial RapidPlan model was trained using 48 patients who received 60 Gy to prostate (PTV60) and 44 Gy to pelvic nodes (PTV44) in 20 fractions. To improve the model's goodness-of-fit, an intermediate model was generated using the dose-volume histograms of best-spared organs-at-risk (OARs) of the initial model. Using the intermediate model and manual tweaking, all 48 cases were re-planned. The final model, trained using these re-plans, was validated on 50 additional patients. The validated final model was used to determine any planning advantage of using three arcs instead of two on 16 VMAT cases and tested on 25 additional cases to determine efficacy for single-PTV (PTV60-only) treatment planning.ResultsFor model validation, PTV V95% of 99.9% was obtained by both clinical and knowledge-based planning. D1% was lower for model plans: by 1.23 Gy (PTV60, CI = [1.00, 1.45]), and by 2.44 Gy (PTV44, CI = [1.72, 3.16]). OAR sparing was superior for knowledge-based planning: ΔDmean = 3.70 Gy (bladder, CI = [2.83, 4.57]), and 3.22 Gy (rectum, CI = [2.48, 3.95]); ΔD2% = 1.17 Gy (bowel bag, CI = [0.64, 1.69]), and 4.78 Gy (femoral heads, CI = [3.90, 5.66]). Using three arcs instead of two, improvements in OAR sparing and PTV coverage were statistically significant, but of magnitudes < 1 Gy. The model failed at reliable DVH predictions for single PTV plans.ConclusionsOur knowledge-based model delivers efficient, consistent plans with excellent PTV coverage and improved OAR sparing compared to clinical plans.  相似文献   

7.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

8.
9.
PurposeTo increase the superficial dose and reduce the brain dose for radiotherapy of scalp angiosarcoma, we propose a novel irradiation technique of tangential irradiation volumetric modulated arc therapy (TI-VMAT).MethodsTI-VMAT and the conventional VMAT treatment plans for thirteen scalp angiosarcoma patients were created with a prescribed dose of 70 Gy. Each treatment was normalized to cover 95% of the planning target volume (PTV) with its prescribed dose. To realize TI-VMAT, an avoidance structure (AS) function was applied. AS was defined as a contour subtracted PTV by a certain space from the brain contour. TI-VMAT treatment plans for six different spaces between PTV and AS were developed and compared with the conventional VMAT treatment plan with respect to the following dosimetric parameters: homogeneity index (HI) and conformity index (CI) of the PTV, mean brain dose, and brain volume irradiated with 20% (V20% [cc]), 40% (V40% [cc]), 60% (V60% [cc]), 80% (V80% [cc]), and 100% (V100% [cc]) of the prescribed dose.ResultsHI and CI were comparable between TI-VMAT and the conventional VMAT, the mean brain dose for TI-VMAT with AS defined by a space of 2.0 cm and jaw tracking was 14.27 Gy, which was significantly lower than that for the conventional VMAT (21.20 Gy). In addition, dosimetric parameters such as V20% [cc] were significantly suppressed compared to those for high doses.ConclusionOur proposed irradiation technique TI-VMAT shows the potential to reduce radiation doses in the brain with maintaining higher dose coverage on the PTV.  相似文献   

10.
BackgroundAcuros XB (AXB) may predict better rectal toxicities and treatment outcomes in cervix carcinoma. The aim of the study was to quantify the potential impact of AXB computations on the cervix radiotherapy using the RapidArc (RA ) technique as compared to anisotropic analytical algorithm (AA) computations.Materials and methodsA cohort of 30 patients previously cared for cervix carcinoma (stages II–IIIB) was selected for the present analysis. The RA plans were computed using AA and AXB dose computation engines under identical beam setup and MLC pattern.ResultsThere was no significant (p > 0.05) difference in D95% and D98% to the planning target volume (PTV); moreover, a significant (p < 0.05) rise was noticed for mean dose to the PTV (0.26%), D50% (0.26%), D2% (0.80%) and V110% (44.24%) for AXB computation as compared to AA computations. Further, AXB estimated a significantly (p < 0.05) lower value for maximum and minimum dose to the PTV. Additionally, there was a significant (p < 0.05) reduction observed in mean dose to organs at risk (OARs) for AXB computation as compared to AA, though the reduction in mean dose was non-significant (p > 0.05) for the rectum. The maximum difference observed was 4.78% for the rectum V50Gy, 1.72%, 1.15% in mean dose and 2.22%, 1.48% in D2% of the left femur and right femur, respectively, between AA and AXB dose estimations.ConclusionFor similar target coverage, there were significant differences observed between the AAA and AXB computations. AA underestimates the V50Gy of the rectum and overestimates the mean dose and D2% for femoral heads as compared to AXB. Therefore, the use of AXB in the case of cervix carcinoma may predict better rectal toxicities and treatment outcomes in cervix carcinoma using the RA technique.  相似文献   

11.
PurposeTo implement a knowledge-based (KB) optimization strategy to our adaptive (ART) early-regression guided boosting technique in neo-adjuvant radio-chemotherapy for rectal cancer.Material and methodsThe protocol consists of a first phase delivering 27.6 Gy to tumor/lymph-nodes (2.3 Gy/fr-PTV1), followed by the ART phase concomitantly delivering 18.6 Gy (3.1 Gy/fr) and 13.8 Gy (2.3 Gy/fr) to the residual tumor (PTVART) and to PTV1 respectively. PTVART is obtained by expanding the residual GTV, as visible on MRI at fraction 9. Forty plans were used to generate a KB-model for the first phase using the RapidPlan tool. Instead of building a new model, a robust strategy scaling the KB-model to the ART phase was applied. Both internal and external validation were performed for both phases: all automatic plans (RP) were compared in terms of OARs/PTVs parameters against the original plans (RA).ResultsThe resulting automatic plans were generally better than or equivalent to clinical plans. Of note, V30Gy and V40Gy were significantly improved in RP plans for bladder and bowel; gEUD analysis showed improvement for KB-modality for all OARs, up to 3 Gy for the bowel.ConclusionsThe KB-model generated for the first phase was robust and it was also efficiently adapted to the ART phase. The performance of automatically generated plans were slightly better than the corresponding manual plans for both phases.  相似文献   

12.

The aim of this study was to investigate the effect of a hybrid technique which results from combining intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for the treatment of cervical cancer patients. Plans made with the hybrid technique and pure IMRT and VMAT were retrospectively compared in 20 patients with cervical cancer at different stages. All plans were made using the same contours based on the original computed tomography (CT) scans. Conformity (CI) and homogeneity (HI) indices of the planning target volumes (PTVs) were calculated for each technique in order to evaluate plan quality. All techniques were compared in terms of dose to organs at risk (OARs), number of monitor units (MUs) and treatment time. It turned out that plans made with the hybrid technique had improved dose conformity and homogeneity compared to plans made only with IMRT and VMAT (p < 0.001). Regarding the OARs, the maximum dose (Dmax) delivered to the bladder, rectum and femoral heads was lower for the hybrid plans compared to the IMRT and VMAT plans (p < 0.001). The volumes irradiated to doses of 50 Gy (V50Gy) for rectum, bladder and bowel were lower for the hybrid plans (p < 0.001, p = 0.002). Furthermore, the treatment time and MU values for the hybrid plans were found to be between of the values for the IMRT and VMAT plans. It is concluded that, as compared to IMRT and VMAT plans, the hybrid plan technique allowed a better conformity and homogeneity for the dose distribution in the PTV and a dose reduction to the OARs.

  相似文献   

13.
BackgroundThe aim of this study was to investigate the performance of the RapidPlan (RP ) using models registered pseudostructures, and to determine how many structures are required for automatic optimization of volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer.Materials and methodsPseudo-structures around the PTV were retrospectively contoured for patients who had completed treatment at five institutions. For 22 common patients, plans were generated with a single optimization for models with two (RP_2), four (RP_4), and five (RP_5) registered structures, and the dosimetric parameters of these models were compared with a clinical plan with several optimizations.ResultsMost dosimetric parameters showed no major differences between each RP model. In particular, the rectum Dmax, V50Gy, and V40Gy with RP_2, RP_4, and RP_5 were not significantly different, and were lower than those of the clinical plan. The average proportions of plans achieving acceptable criteria for dosimetric parameters were close to 100% for all models. Using RP_2, the average time for the VMAT planning was reduced by 88 minutes compared with the clinical plan.ConclusionThe RapidPlan model with two registered pseudo-structures could generate clinically acceptable plans while saving time.  相似文献   

14.
PurposeRadiation therapy plans are assessed using dose volume metrics derived from clinical toxicity and outcome data. In this study, plans for patients with locally advanced non-small cell lung cancer (LA-NSCLC) are examined in the context of the implementation of the Acuros XB (AXB) dose calculation algorithm focussing on the impact on common metrics. Methods: Volumetric modulated arc therapy (VMAT) plans were generated for twenty patients, using the Analytical Anisotropic Algorithm (AAA) and recalculated with AXB for both dose to water (Dw) and dose to medium (Dm). Standard dose volume histogram (DVH) metrics for both targets and organs-at-risk (OARs) were extracted, in addition to tumour control probability (TCP) for targets. Results: Mean dose to the planning target volume (PTV) was not clinically different between the algorithms (within ±1.1 Gy) but differences were seen in the minimum dose, D99% and D98% as well as for conformity and homogeneity metrics. A difference in TCP was seen for AXBDm plans versus both AXBDw and AAA plans. No clinically relevant differences were seen in the lung metrics. For point doses to spinal cord and oesophagus, the AXBDm values were lower than AXBDw, by up to 1.0 Gy. Conclusion: Normalisation of plans to the mean/median dose to the target does not need to be adjusted when moving from AAA to AXB. OAR point doses may decrease by up to 1 Gy with AXBDm, which can be accounted for in clinical planning. Other OAR metrics do not need to be adjusted.  相似文献   

15.
PurposeTo propose a “staggered overlap” technique in volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI) and compare the dose distribution and plan robustness with “overlap” technique and “gradient optimization” approach.Methods and Materials6 patients previously treated in our clinic were retrospectively selected. 9 VMAT plans of each patient were optimized with “staggered overlap”, “overlap” and “gradient optimization” in overlapping region of 3 cm, 6 cm, and 9 cm separately. For the “staggered overlap” plan, adjacent field sets were intentionally overlapped by staggering field edges in an appropriate step size to avoid sharp dose gradient. Evaluation metrics including V95%, D2%, D98%, conformity number (CN) and homogeneity index (HI) were employed to evaluate the dose distribution. Moreover, shifts of the upper spinal field isocenter in each direction were performed to simulate junction errors for robustness analysis.ResultsThe CN and HI of VMAT plans with “staggered overlap” were 0.82 (0.811–0.822) and 0.113 (0.112–0.114), while they were 0.778 (0.776–0.782) and 0.131 (0.130–0.131) for plans with “gradient optimization”. In the robustness study, <3% dose deviations were found for 5 mm shifts in lateral and vertical directions with all techniques. In cranial-caudal direction, “overlap” technique created hot spots (D2% > 170%) and cold spots (D98% < 44%) in the junction region with 10 mm shifts. The dose deviations were decreased to 22% for plans with “staggered overlap” and 9 cm overlapping region.Conclusion“Staggered overlap” technique provides better plan quality as compared to “gradient optimization” approach and makes the plan more robust against junction errors as compared to “overlap” technique.  相似文献   

16.
The impact of a rectal spacer and an increased near maximum target dose in VMAT prostate SBRT is studied.For a group of 11 patients (35 Gy-in-five-fractions VMAT prostate SBRT) a set of 4 plans were generated, namely two VMAT plans, with D2%  37.5 Gy (Hom) and with D2%  40.2 Gy (Het), were created for each of two CT scans taken before (NoSpc) and after (Spc) transperineal spacer insertion. Consequently the methodology for parameter invariant TCP (tumor control probability) plan ranking was applied for comparison of the plans in terms of tumor control. NTCPs (normal tissue complication probabilities) were calculated for rectum and bladder using Lyman’s model.For all 11 patients the TCP plan ranking has shown that the Het plans would perform considerably better in TCP terms than the Hom ones. The plans without rectal spacer were ranked worse compared to those with rectal spacer except for one set of Hom plans. The calculated NTCPs for rectum produced by the Het plans were quite similar to the NTCPs of the Hom ones. The rectal NTCPs of the Hom Spc plans were always lower than the NTCPs of the Hom NoSpc plans. The NTCP values for bladder were extremely low in all cases.The use of rectal spacer leads in general to lower risk of rectal complications, as expected, and even to better tumor control. Plans with increased near maximum target dose (D2%  40.2 Gy) are expected to perform much better in terms of tumor control than those with D2%  37.5 Gy.  相似文献   

17.
AimTo assess a class solution template for volumetric-modulated arc therapy (VMAT) for prostate cancer using plan analysis software.BackgroundVMAT is a development of intensity-modulated radiotherapy (IMRT) with potential advantages for the delivery of radiotherapy (RT) in prostate cancer. Class solutions are increasingly used for facilitating RT planning. Plan analysis software provides an objective tool for evaluating class solutions.Materials and methodsThe class solution for VMAT was based on the current static field IMRT template. The plans of 77 prostate cancer patients were evaluated using a set of in-house plan quality metrics (scores) (PlanIQ™, Sun Nuclear Corporation). The metrics compared the class solution for VMAT planning with the IMRT template and the delivered clinical plan (CP). Eight metrics were associated with target coverage and ten with organs-at-risk (OAR). Individual metrics were summed and the combined scores were subjected to non-parametric analysis. The low-dose wash for both static IMRT and VMAT plans were evaluated using 40 Gy and 25 Gy isodose volumes.ResultsVMAT plans were of equal or better quality than the IMRT template and CP for target coverage (combined score) and OAR combined score. The 40 Gy isodose volume was marginally higher with VMAT than IMRT (4.9%) but lower than CP (−6.6%)(P = 0.0074). The 25 Gy volume was significantly lower with VMAT than both IMRT (−32.7%) and CP (−34.4%)(P < 0.00001).ConclusionsAutomated VMAT planning for prostate cancer is feasible and the plans are equal to or better than the current IMRT class solution and the delivered clinical plan.  相似文献   

18.
PurposeWe investigated the feasibility of robust optimization for volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) for liver cancer in comparison with planning target volume (PTV)-based optimized plans. Treatment plan quality, robustness, complexity, and accuracy of dose delivery were assessed.MethodsTen liver cancer patients were selected for this study. PTV-based optimized plans with an 8-mm PTV margin and robust optimized plans with an 8-mm setup uncertainty were generated. Plan perturbed doses were evaluated using a setup error of 8 mm in all directions from the isocenter. The dosimetric comparison parameters were clinical target volume (CTV) doses (D98%, D50%, and D2%), liver doses, and monitor unit (MU). Plan complexity was evaluated using the modulation complexity score for VMAT (MCSv).ResultsThere was no significant difference between the two optimizations with respect to CTV doses and MUs. Robust optimized plans had a higher liver dose than did PTV-based optimized plans. Plan perturbed dose evaluations showed that doses to the CTV for the robust optimized plans had small variations. Robust optimized plans were less complex than PTV-based optimized plans. Robust optimized plans had statistically significant fewer leaf position errors than did PTV-based optimized plans.ConclusionsComparison of treatment plan quality, robustness, and plan complexity of both optimizations showed that robust optimization could be feasibile for VMAT of liver cancer.  相似文献   

19.
PurposeTo implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer.MethodsTen prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively. Second, the planning CT (pCT) was deformably registered to the CBCT to create a synthetic CT (sCT). Both daily and weekly sampling strategies were employed to determine optimal dose accumulation frequency. Doses were recalculated on sCTs for both ± 3 mm/±3% and ± 5 mm/±3% uncertainties and were accumulated back to the pCT. Accumulated doses generated from ± 3 mm/±3% and ± 5 mm/±3% RO-IMPT plans were evaluated using the clinical dose volume constraints for CTV, bladder, and rectum.ResultsDaily accumulated dose based on both ± 3mm/±3% and ±5 mm/±3% uncertainties for RO-IMPT plans resulted in satisfactory CTV coverage (RO-IMPT3mm/3% CTVV95 = 99.01 ± 0.87% vs. RO-IMPT5mm/3% CTVV95 = 99.81 ± 0.2%, P = 0.002). However, the accumulated dose based on ± 3 mm/3% RO-IMPT plans consistently provided greater OAR sparing than ±5 mm/±3% RO-IMPT plans (RO-IMPT3mm/3% rectumV65Gy = 2.93 ± 2.39% vs. RO-IMPT5mm/3% rectumV65Gy = 4.38 ± 3%, P < 0.01; RO-IMPT3mm/3% bladderV65Gy = 5.2 ± 7.12% vs. RO-IMPT5mm/3% bladderV65Gy = 7.12 ± 9.59%, P < 0.01). The gamma analysis showed high dosimetric agreement between weekly and daily accumulated dose distributions.ConclusionsThis study demonstrated that for RO-IMPT optimization, ±3mm/±3% uncertainty is sufficient to create plans that meet desired CTV coverage while achieving superior sparing to OARs when compared with ± 5 mm/±3% uncertainty. Furthermore, weekly dose accumulation can accurately estimate the overall dose delivered to prostate cancer patients.  相似文献   

20.
PurposeAdaptive Stereotactic Body Radiotherapy (SBRT) of prostate cancer (PC) by online 1.5 T MRi-guidance prolongs session-time, due to contouring and planning tasks, thus increasing the risk of prostate motion. Hence, the interest to verify the adequacy of the delivered dose.Material and methodsFor twenty PC patients treated by 35 Gy (Dp) in five fractions, daily pre- and post- delivery MRi scans were respectively used for adapt-to-shape (ATS) optimization, and re-computation of the delivered irradiation (Drec). Two expansion recipes, from Clinical (CTV) to Planning target volume (PTV), which slightly differed in the posterior margin were used for groups I and II, of ten patients each. Plans had to assure D95% ≥ 95%Dp to PTV, and D1cc ≤ Dp to rectum, bladder, penile bulb, and urethral planning-risk-volume (urethral-PRV). The adequacy of the delivered dose was estimated by inter-fraction average (ifa) of dose-volume metrics computed from Drec. A cumulative dose (Dsum) was calculated from the five daily Drec deformed onto the simulation MRi.ResultsFor each patient, CTV coverage resulted in D95% > 95%Dp when estimated as ifa by Drec. No significant difference for D95% and D99% metrics to CTV resulted between groups I and II. D1cc was < Dp for rectum, urethral-PRV, and penile bulb, whereas < 103.5%Dp for the bladder.Significant correlations resulted between metrics computed by Dsum and as ifa by Drec, by both linear-correlation analysis, and Receiver-Operating-Characteristic curve analysis.ConclusionsOur results for PC-SBRT confirm the adequacy of the delivered dose by ATS with 1.5 T MR-linac, and the consistency between dose-volume metrics computed by Drec and Dsum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号